HomeMy WebLinkAboutCOMCHECK - 08-00224 & 08-00225 - Rod Jones Real Estate Office (2)2006 IECC
08 00224 & 08 00225
COMcheck Software Versit Rod Jones BuildingRevisions 5/23/08
Envelope Compliaill Ill c GI LII IVQ LV
Report Date: 05/19/06
Data f lename: S:\Drawings1366-Rod JoneskRodJones.cck
Section 1: Project Information
Project Type: New Construction
Project Title : Rod Jones Facility - Idaho's Realtor
Construction Site:
Rexburg, ID 83440
Owner/Agent:
Rod Jones
Section 2: General Information
Building Location (for weather data):
Rexburg, Idaho
Climate Zone:
6b
Heating Degree Days (base 65 degrees F):
8693
Cooling Degree Days (base 50 degrees F):
1446
Vertical Glazing / Wall Area Pct.:
18
Activity Type(s)
Office
Section 3: Requirements Checklist
Envelope PASSES: Design 3% better than code.
Climate -Specific Requirements:
Floor Area
5512
Designer/Contractor:
Johnny Watson
JRWA
1152 Bond Ave
Rexburg, ID 83440
359-2309
jwatson@jma.com
p EC EE INE
D
MAY 2 3 2008
CITY OF REXE3G
Component NamelDescription
Gross Area
Cavity
Cont.
Proposed
Budget
or Perimeter
R -Value
R -Value
U -Factor
U -Factor
Roof 1: Attic Roof with Wood Joists
4165
38.0
0.0
0.027
0.034
Exterior Wall 1: Wood -Framed, 16" o.c.
3000
19.0
0.0
0.067
0.089
Window 1: Vinyl Frame:Double Pane with Low -E, Clear, SHGC 0.70
519
--
--
0.550
0.350
Door 1: Glass, Entrance Door, SHGC 0.40
42
--
--
0.350
0.800
Door 2: Insulated Metal, Swinging
42
--
--
0.600
0.700
Basement Wall 1: Solid Concrete:10" Thickness, Medium Density,
972
11.0
0.0
0.092
0.323
Furring: Wood, Wall Ht 9.0, Depth B.G. 8.0
Floor 1: Wood-Fmmed
4165
19.0
0.0
0.051
0.034
(a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements.
Air Leakage, Component Certification, and Vapor Retarder Requirements
1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance
with the manufacturer's installation Instructions.
❑ 2. Windows, doors, and skylights certified as meeting leakage requirements.
3. Component R -values & U -factors labeled as certified.
4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that
achieves the rated R -value without compressing the insulation.
Project Title: Rod Jones Facility - Idaho's Realtor
Data filename: S:\Drawings\366-Rod Jones\RodJones.cck
Report date: 05/19/08
Page 1 of 4
5. No roof insulation is installed on a suspended ceiling with removable ceiling panels.
6. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized
dampers.
7. Cargo doors and loading dock doors are weather sealed.
8. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly with a
0.5 inch clearance from combustible materials and with 3 inches clearance from Insulation material.
9. Building entrance doors have a vestibule and equipped with closing devices.
Exceptions:
Building entrances with revolving doors.
Doors that open directly from a space less than 3000 sq. R. in area.
10.Vapor retarder Installed.
Section & C.om Dllance Statement ,.
;mpliance State e . The pro s envelope d n represented in this document is consistent with the building plans, specifications
and other calcullidicyle submitt w' this permi lication. The proposed envelope system has been designed to meet the 20061ECC
requirement Mcheck er n3. an co y with the mandatory requirements in the Requirements Checklis .
_W5071 -
Title Signature Da
Project Title: Rod Jones Facility - Idaho's Realtor Report date: 05/19/08
Data filename: SADrawings\366-Rod Jones\RodJones.cck Page 2 of 4