I have reviewed the plans for the Continental Park Apartments and have identified
the following discrepancies, additions or questions:
1. Provide storm pond calculations.
2. Get with John Millar and work out a Development Agreement.
3. Identify that setbacks are to eaves.
4. Show right-of-way lines. If they do not exist, please provide
documentation dedicating the area from the back of the sidewalks towards
the street to the City of Rexburg.
5. Identify handicap parking spaces along with signs identifying them and
the accessible routes into the buildings.
6. Identify trash facilities.
7. Sheet DT -4 calls out welded wire fabric. Please change this to 1/2" rebar at
18" o.c. in both directions as per the City of Rexburg specifications. Also
identify the approach and sidewalk at the approach as 6" thick. The curb
and gutter must also be reinforced. Please identify 24 4 rebar in the curb
and gutter section.
8. The architectural drawings and the stair drawings must be stamped by a
licensed professional.
9. All units on the lower level must be constructed as "Type B" units as per
Section 1103.1.9.3 of the 1997 Uniform Building Code (UBC). Please
change bathroom configuration for compliance. Please identify grab bar
backing, accessible thresholds and all other accessible features.
10. For the "Type A" unit please identify grab bar backing, accessible
thresholds and all other accessible features.
11. Please identify smoke detectors as per the UBC and 2A- l OBC fire
extinguishers in each apartment unit.
12. Sheet SL3 identifies 2" washers on the anchor bolts. Are these the 2"
square washers as identified in the UBC?
13. Please identify firewall construction, including draftstops. Unit separation
must be maintained from foundation to roof sheathing.
14. Please identify fire separation at the floors between units. Engineered
joists have their own requirements for fire protection and are not listed in
the UBC. Please provide this information on the plans.
15. Please identify attic ventilation as per the UBC.
16. I have attached a copy of the Fire Department review to the back of this
document. Please resolve any issues identified by them
Please provide me with 2 new copies of any corrected plans. If you have any
questions, please give me a call at 359-3020 ext. 324.
Sincerely,
Val Christensen
Building Official
C.C. John Millar
Chris Huskinson
Lyle Cook
REXBURG MADISON COUNTY FIRE DEPARTMENT
P.O. Box 280
26 North Center
Rexburg, Idaho 83440
(2 08) 359-3010
1997 Uniform Fire Code
Plan Review
Plan Date: 5-02
Review Date: 7-17-02
Building Name: CONTINENTAL PARK APARTMENTS
Building Address: CORNER OF 5' WEST AND 7TH SOUTH
Stories: 2.5 Type of Construction: V -N
Occupancy Classification: R-1 Existing Floor Area: N/A
New Construction Floor Area: APPROXIMATELY 5400 SQUARE
FEET/BUILDING
1).Required Fire Flow (Appendix III -A): 2,000 GPM/TWO HOURS
Comments: FIRE FLOW REQUIREMENTS MAY BE REDUCED BY 75 PERCENT IF
BUILDINGS HAVE AN APPROVED AUTOMATIC SPRINKLER SYSTEM
2).Water Supply (Article 9, Section 903) Required: YES
Fire Hydrant Location: TWO PROPOSED
Fire Hydrant Flows: UNKNOWN
Fire Flow Test Location:
Fire Flow Supplied By:
Other Approved Water Source: NONE
Water Supply Acceptable: YES
Fire Hydrant Location Acceptable: YES
Water Supply Comments: NONE
3.)Fire Apparatus Access Roads (Article 9 Section 902)
Required: YES
Acceptable: Width: YES Length: YES Surface: YES
Turning Radius: Grade: Vehicle Vertical:
Clearance: Turn Arounds:
Complete Road Acceptable: YES
Comments:
4).Access Roads and Water Supply, Including Fire Hydrants Are
Required To Be Installed And Made Serviceable Prior To And During
Time Of Construction (Article 9 Section 901.3): YES
Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION A STOP WORK ORDER
WILL BE ISSUED.
5),Installation Of Portable Fire Extinguisher (Article 10 Section
1002) Required: YES
Location Acceptable: NOT SHOWN
Type Provided Acceptable: NOT SHOWN
Comments: PROVIDE MINIMUM OF ONE FIRE EXTINGUISHER PER UNIT,
MINIMUM SIZE OF 2A10BC EACH
6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003
Required: NO Type Of System Being Installed:
Sprinkler System Monitoring Required (Article 10 Section 1003.3)
Required: NO
Comments:
7).Standpipes (Article 10 Section 1004) Required: NO
Type Required:
Comments:
8).Ventilating Hood And Duct Fire Extinguishing System (Article 10
Section 1006.2) Required: NO
Type Being Provided:
Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4):
Portable Fire Extinguisher Shown (Article 10 section 1006.2.7):
Comments:
9).Fire Alarm Systems (Article 10 Section 1007)Required: YES, SEE
COMMENTS
Type Of System Required: Manual: Automatic: Both:
Type Of System Being Provided: Manual: Automatic: Both:
Components Of System Shown: Smoke Detectors: Heat Detectors:
Manual Pull Station: Sounding Devices: Visual Devices:
Door Holders: Duct Detectors: Flow Alarm:
Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO
Comments: PROVIDE SMOKE DETECTORS IN EACH SLEEPING ROOM AND
ADJACENT HALLWAYS/CORRIDORS.
10).Other Corrections That Are Required By Special Occupancy Or
Conditions:
Plans As Submitted Are Acceptable: WITH ABOVE ITEMS COMPLIED WITH
Plans Checked By: CHRIS HUSKINSON Date: 7-17-02
Please furnish comments back to the plan reviewer in the following
manner: Written Comments: New Plans: