HomeMy WebLinkAboutPROJECT INFORMATION - 08-00222 - 5536 S 3100 W - MechanicalApr 22 08 10:13a Ubuildit Short Form Entire House 2085426478 p.2 Job: 08-0051 Date: 002012M8 By: Alex Contreras EVOLUTION COMFORT HEATING & AIR CONDI7IONING 447 Voider, IdahD Falls, ID 83401 Phone: (208)528-7410 Fax: (208)52&7414 Email: alextzmtrer Pr 08 00222 .- For Camel Miller Idaho Falls, I D $ 5536 S 3100 W-Snedaker 3401 HEATING EQUIPMENT Make Payne Trade Payne Model PG9MAB036040* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 40000 Btuh 37000 Btuh 40 of 1000 cfm 0.029 cfm/Btuh 0.60 in H2O COOLING EQUIPMENT Make Payne Trade Payne PA13 Cond PA13NR018(G)--A Coil CNRV*2417A**+TXV Design Inf« « Htg CIg Infiltration Outside db (`F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Semi -loose Design TD (°F) 76 14 Fireplaces D Daily range - H Inside humidity (°lo) - 50 Moisture difference (gr/lb) - -31 HEATING EQUIPMENT Make Payne Trade Payne Model PG9MAB036040* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 40000 Btuh 37000 Btuh 40 of 1000 cfm 0.029 cfm/Btuh 0.60 in H2O COOLING EQUIPMENT Make Payne Trade Payne PA13 Cond PA13NR018(G)--A Coil CNRV*2417A**+TXV Area M12) Htg load (Btuh) Efficiency 13 SEER CIg AVF (cfm) Sensible cooling 14080 Btuh Latentcooling 3520 Btuh Total cooling 17600 Btuh Actual air flow 900 cfrn Air flow factor 0.066 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 1.00 2402 ROOM NAME Area M12) Htg load (Btuh) CIg load (Btuh) Htg AVF (cfm) CIg AVF (cfm) M Bath 50 2105 229 61 15 M Closet 57 2402 263 69 17 M Room 204 3923 2366 113 157 Kitchen 120 2402 3157 69 210 Dining 102 3104 564 89 37 Mechanical 18 854 91 25 6 Closet 9 427 45 12 3 Bed 171 4957 1568 143 104 Bath 47 1168 270 34 18 Bed 2 146 4702 1776 135 118 Laundry 20 0 0 0 0 Hallway 1 k';_.. Q..__ 52 0 fru$ 0 0 0 3209 2f49 213 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. %gvnQhtSC)ft Right-SuiteResdentia16.0.51 RSR43361 20Da-Apr-21 17:19:30 XCK C:00cum rds and 5et#r19MA18jandro GW1rera5lDeAbp1Wtl9htW11 HVAGINr F*ress job# 08-0051.rrp Page 1 Apr 22 08 10:13a Ubuildit ., 2085426478 p.3 �-r Entire House d 1298 34702 13538 1000 900 Other equip loads 477 1794 Equip. @ 0.94 RSM 14413 Latent cooling 0 TnTA1 C 47no 4G4'70 4Ae-t* Anna nnn uw UIvv Printout certified by ACCA to meet all requirements of Manual J 8th Ed. "- wvnghtsofit Right -Suite Residential 6.0.51 RSR43351 247013 -Apr -21 t7:19:30 r,:0ocuments and SetingsWejandro CoMreraMDesldoplVYrf9htsofl WACUUr Eavress jots# 08-0051.nrp Page 2 Apr 22 08 10;14a Ubuildit 2485426478 p.4 Building Analysis Job: 08-0051 J" Date: 04!20!2008 Entire Douse By: Alex Caress EVOLUTION COMFORT HEATING & AIR 447 VWhdder, Idaho Falls 1083101 Phho2 ("P8-7Q1YFax%8)528-7410 Emaih alexcbnteras4wMesIxet For. Carries Miller Idaho Falls, ID 83401 Dian Canditic Location: Idaho Falls, 10, US Elevation: 4741 It Latitude: 44 °N $tuh/W Indoor: Indoortemperature (°F) Desiggn iD {`Fl ReUtvne humiddity (° } Heating 70 76 50 Cooling 75 14 50 Outdoor: Heating Dry bulb ('F) -6 Dai 1v range OF) - We bulb (°F} - Wind speed (mph) 15.0 Cooling 89 34 ( H } 60 7.5 Moisture difference (gr/ib) Infiltration: Method Construction quality Fireplaces 61.5 Simplified Semi -loose 0 -31.5 Heating Component $tuh/W Btuh % of load Walls 4-9 6600 18.8 Glazing 25-6 2846 8.1 Doors 29-6 2490 7.1 Ceilings 2.0 2564 7.3 Floors 3.8 4931 14.0 Infiltration 6.5 9999 28-4 Ducts 5273 15.0 Piping 0 0.0 Humidification 0 OA Ventilation 477 1.4 Adjustments -0 Total 35178 100.0 Cooling Component Btuh/W Stuh % of load Walls 0.5 634 4.1 Glazing 39.8 4255 27.8 Doors 7.2 606 4.0 Ceilings 1.6 2092 13.6 Floors 0-1 130 0.8 Infiltration 0.6 947 6.2 Ducts 1566 10.1 Ventilation 88 0.6 Internal gains 3320 21.7 Blower 1707 11-1 Adjustments 0 Total 15333 100.0 Overall U -value = 0.062 Btuhlft2-*F Data entries checked. mih� ,,�-,.. vvr-*g"t:SX>t Righ6SWeResidential0.0.51 RSR43361 2008 -Apr -21 17:19-.30 /1CCK C.10ourrmts and 5etbNeXA1ejandra forAmrastDesktoplMightsoft HVAC%Aw Exprasspba 08.0051.rrp Page 1 Apr 22 08 10:14a Ubuildit 2085426478 p.5 . , Component Constructions Job: 0$-x651 21.0 Entire House Date: 04/20=08 0.47 139 By: Max Contreras 381 EVOLUTION COMFORT HEATING & AIR 21.0 4.94 CONDITIONING 0.47 447 V"fer, t(rato Fal Is, 11)63401 Phone: (208),42&7410 FaX (208)528.7410 Email: a3exC0ntteraz@gwes1.net s 275 0.065 21.0 Project Infarmation 1358 For Carriel Miller W 388 I dah o Fails, I D 83401 21.0 4.94 Design Conditions 0.47 Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature ('F) 70 75 Elevation: 4741 ft o } 634 Latitude: 44 ON RRelatg a humidity (%) 5p 5t0 Outdoor: bleating Cooling Moisture difference (gr/lb) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: s Baily range (°F) - 34 (H) Method Simplified Wet bulb (' ) Wind speed (mph) - 60 Construction quality 15.0 7.5 Fireplaces Semi -loose 0 Construction descr"ons or Ama 1.1 -value Insu! R Htg F(TM toss Cig HTM Gain (nq (etuhM-'F) (m= rauh) (Btuh0r) (etch) (BtuW) (Oita) Wallis 12F-Osw Wood stud frame, siding or stucco, no board insulation, R-21 cavity insulation Partitions (none) Windows 61A: Window U-.35, clear low -e; Mr/o outdoor inset screent, clear low -e Doors 11D0^ Wood door, sofid ooie, no storm Cellings 16A-38ad: Ceiling underunvented atfic, no radiant barrier, dark shingles, R-38 irsul. Floors n 293 0.065 21.0 4.94 1445 0.47 139 e 381 0.065 21.0 4.94 1884 0.47 181 s 275 0.065 21.0 4.94 1358 0.47 130 W 388 0.065 21.0 4.94 1917 0.47 184 all 1336 0.065 21.0 4.94 6600 0.47 634 e 55 0.350 0.0 26.6 1463 40.5 2225 s 4 0.350 0.0 26,6 106 22.0 W W 48 0.350 0.0 26.6 1277 40.5 1942 all 107 0.350 0.0 26.6 2846 39.8 4255 e 42 0.390 0.0 29.6 1245 7.22 303 W 42 0.390 0.0 29.6 1245 7.22 303 all 84 0.390 0.0 29.6 2490 7.22 606 1298 0.026 38.0 1.98 2564 1.61 2092 20P -19c: Carpeted floor over open crawltgarage, R-19 blanket 1298 0.050 19.0 3.80 4931 0.10 130 insulation VNnght ooft RightSuiteReadeniia16.0.51 RSR4=1 2068-Apr.21 17:19:30 AGGI4 CA00cuments and SettingsWejandro ContrerasiDesktoplWrighiwn H/AMAIr E)pms job# 0&0051.rrp (age 1 Apr 22 08 10:14a Ubuildit .� Project Summary Entire House EVtOLl�fIIONN��C(OMFORT HEATING & AIR 447 Mittel, Idaho falls, !D 83401 P wr 5Z8 771D -JN 3)529-7410 Emait alexaantretasQgwest.net 2085426478 p.6 11 Job: 08-0051 Date: 0412=008 Alex Coiftwm For. Air Express Idaho Falls, ID 83401 Nates: Some registers are shown further from the wall or windows for clarity. During installation put registers in standard distance from walls or windows. Design Inf• Weather: Idaho Falls, ID, US Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TD 76 OF Heating Summary 0.70 Strutatexe Equi AVF (cif ) 50 DwIs X73 Btuh Central vent (7 cfm) 477 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 35178 Btuh Infitration Method Simplified Construction quality Semi -loose Fireplaces 0 Heating Equipment Summary Summer Design Conditions Outside db 1 9� Cool, Area (ft') 75 OF Volume (ft') 12202 12202 Daily range 0.70 0.3673 Equi AVF (cif ) 50 % Heating Equipment Summary Summer Design Conditions Outside db 89 OF I nide db 75 OF Design TO 14 OF Daily range H Stuh Relativve humidity 50 % Moisture differerce -31 grub Sensible Cooling Equipment Load Sizing Structure 11984 Btuh Ducts 1555 Btuh Central vent (7 cfm) 88 Btuh Blower 1707 Btuh Use manufacturer's data n Rate/swing mufiier 0.94 Equipment sensi a load 14413 Btuh Latent Cooling Equipment Load Sizing Structure -517 Btuh Ducts -225 Btuh Central vent (7 cfm) -122 Btuh Equipment latent load 0 Stuh Equipment total load 14413 Stub Req. total capacity at 0.80 SHR 1.5 ton Cooling Equipment Summary Make Payne Make Payne Trade Paayyne Trade Payne PA13 Model P&ZAB036040* Cond PA13NR018(G)-A Coil CNRV*2417A**+TXV Efficiency 92.1 AFUE Efficiency 13 SEER Heating input 40000 Btuh Sensible cooling 14080 Both Heating output 37000 Btuh Latent cooling 3520 Btuh Temperature rise 40 OF Total cooling 17600 Btuh Actual air f ow 1000 cfm Actual air flow 900 cfm Air flow factor 0.029 cfm/Btuh Air flow factor 0.066 cfmBtuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 1.00 Printout certified by RCCA to meet all requirements of Manual J 8th Ed_ A� Wtr'Iv"tSCYft RlghtSUiteRe9d0ntia16.0A1 RSM351 2008 -Apr -21 17:19:30 C& 0:0=rnents and SetbngslAlejandm Contr ras'd]eskt*ptWright3o t FNACWr EpxessjoW 08-0061.rrp Page 1 Apr 22 08 10:14a Ubuildit 2085426478 p.7 AED Assessment Entire House Job: 08-0051 Date: Oy OM008 By: Atex Contreras Hourly Glazing Load Har of Day Nasty Amor fE06m3 Maximum hourly glazing load exceeds average by 23.7%. House has adequate exposure diversity (AED), based on AED limit of 300A. AED excursion: 0 Stuh .� Wr1Ql' tSC:>'fit Right- u#eReadertUa16.0.51 RSR43351 2408 -Apr -21 171330 ACCii c:lDawmaMa end Set*VslA1ej8nrh0 C0ntrer8aDeS1opMrigttfsofl HVACNAk Express job# O"D51.rrp Page 1 EVOLUTION COMFORT HEATING & AIR CONDITIONING 447 Whitler, Idab F811% ID 83401 Phene: (208)528-7410 Fax (208)628-7410 Emall: alecoonterasQgwest_net 0M a! f For. Carriel Miller Idaho Falls, ID 83401 Design Conditions Location: Idaho Falls, ID, US Indoor: Indoor temperature (OF) Heating 70 Cooling 75 Elevation: 4741 ft Design TD (°F) 76 14 Latitude., 44 ON Relative humidity 50 50 Outdoor: Dry bulb Heating Cooling Moisture difference(gr/1b) 61.5 -31.5 (°F) -6 89 Infiltration: DailWetybu b range (OF) 630 (R) Method Construction quality Simplified Semi -loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Test for• -•Exposure Diversitr Hourly Glazing Load Har of Day Nasty Amor fE06m3 Maximum hourly glazing load exceeds average by 23.7%. House has adequate exposure diversity (AED), based on AED limit of 300A. AED excursion: 0 Stuh .� Wr1Ql' tSC:>'fit Right- u#eReadertUa16.0.51 RSR43351 2408 -Apr -21 171330 ACCii c:lDawmaMa end Set*VslA1ej8nrh0 C0ntrer8aDeS1opMrigttfsofl HVACNAk Express job# O"D51.rrp Page 1 V`Seuuag pue s;uawnaoa�: aau-panab scjmjuooxeje 60=ZZ=L4 IZ jd`d`SwZ OGVL-9Z9(902) XeA OWL-9ZO306 -auoyd 1.SESV2iSa G9'0'9 IOVCS 01 `SIIsl slept jBquapsaU al!nS-ig0i21 iei;v4M Lttb 6aried �6 : 6 .a!eog "° !DNIIV3H 1l10JWUO NOlinl®A3 luaurases IOKR OI'sNe=l 04ePi -*;In IOWED :jo; sejaq.uoO xaIa Aq paw.IoJJad X900-90 :# qor 8'd 8Lb9ztG90Z I!PI!ngn etre:06 80 ZZ AV Wbutias We s;uawrx 60-ZZ:L16Z-AVt gOUZ 6 S B£1 les21 L9,019 IeyuaplsiW gms-14618 Za6ed 66: 6 :OIE% }au IsarAb@sejaquoaxale OCtr2--9Z9(90Z) :xeJ OWL-8ZS{8021 :auNd WK9 01 `stied alepi J04INAA L" "' JNIIV3H IHOJWOO Nalln-IOA3 604£8 CII `Sled o4ePl .eImN! Iapeo :joj selaquoo x9jV Aq PawaaPGd LsOO-so # qar 6'd 81ta9Ztl980Z t!pl!ngn eq6:06 80 ZZ AV Apr 22 08 10:15a Ubuildit .. Duct System Summary Entire House EVOLUTION COMFORT HEATING & AIR CONDITIONING 447 Whiner, Idaho FaIY, ID 53401 Phone: (208)528-7410 Fax (208)528-7410 Email: alexcontrarasQgwest. net 7 - Project Information For. Carriel Miller Idaho Falls, ID 83401 2085426478 p.10 -^a Job: 08-0051 Date: 0412a12008 By: Alex Cordreras Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.27 in H2O 0.27 in H2O Available static pressure 0.33 in H2O 0.33 in H2O Supply/ return available pressure 0.21/0.12 in H2O 0.21 10.12 in H2O Lowest friction rate 0.068 in/100ft 0.068 in/100ft Actual air flow 1000 cfm 900 cfm Total effective length (TEL) 483 ft Supply Branch Detail Table Name Design (Stuh) Htg (cfm) Cig (cfm) Design FR Diarn (in) Rent Size (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk MRoom•A c 1183 57 79 0.079 6 0x0 ShMt 19.5 245.0 st2 M Room c 1183 57 79 0.081 6 Ox 0 ShMt 18.0 240.0 st3 M Closet h 2402 69 17 0.087 6 Ox 0 ShMt 11.0 230.0 st3 KAchen c 3157 69 210 0.078 6 Ox 0 ShMt 27.0 240.0 s12 M Bath h 2105 61 15 0.098 6 Ox 0 ShMt 14.5 200.0 st3A LivingRaomq h 4329 125 107 0.079 6 Oxo SUR 34.5 230.0 st2 LivingRoom h 4329 125 107 0.074 6 OXO ShMt 43,0 240.0 st2A Dining h 3104 89 37 0.069 6 Ox 0 ShMt 38.0 265.0 st2A Balt, h 1168 34 18 0.070 6 Ox 0 ShMt 37.5 250.0 st2A Medhanical h 91 25 6 0.000 0 Ox 0 ShMt 0.0 0.0 closet h 45 12 3 0.000 0 Ox 0 ShMt 0.0 0.0 Bed 2 h 4702 135 118 0.069 6 Ox 0 ShMt 53.0 250.0 st2A Had 1 h 4957 143 104 0.068 6 Ox 0 ShMt 46.5 260.0 s1213 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Cig (cfm) Design FR Veloc (fpm) Diam (in) Rect Duct Size (in) Duct Material Trunk st2 PeakAVF 777 780 0.068 638 14 8 x 22 ShtMetl st1 st2A PeakAVF 526 384 0.068 592 12 8 x 16 ShtMetl at2 st213 PeakAVF 143 104 0.068 429 7 8 x 6 ShtMetl s12A st3 PeakAVF 186 111 0.081 559 8 8 x 6 ShtMetl st1 st3A PeakAVF 61 15 0.098 273 6 8 x 4 ShtMetl st3 stl PeakAVF 963 891 1 0.968 722 15 6 x 24 Shtme t BddljrakcWass have been manually o>nerrfddon ^.t VVn40htSOft Righ"UleResklentia16.0.51 RSR43351 2008•Apr--21 17:18:30 ,4C4:k CADocvmants and Setlings%A*aadro CbntreraslDescroplWdgt tsaR HVACL4k Expma jot* 084051.rrp Page 1 Apr 22 08 10:15a Ubuildit 2085426478 p.11 Return Trunk Detail Table Grill Htg Clg TEL Design Veloc Diann ReatSize Stud/Joist Duct Type Name Size (in) (cfm) (cfsn) (ft) FR (fpm) (in) (in) Opening (in) Mail Trunk rb1 Ox 0 243 190 97.0 0.124 384 8 2-14x3.25 2-10x9 SJSp rtl rb3 Ox 0 135 118 176.5 0.068 429 7 14x3.25 i 10x5 i SJSp rt18 rb4 0x0 479 48$ 125.5 0.096 514 12 3-14x3.25 3-10x14 SJSp 111 rk12 0x0 143 104 '146.5 0.082 452 7 14x3.25 10x5 SJSp rt1A Return Trunk Detail Table AE, vvrightgp't Right-8LAteResidential6.p.51 RSR43351 2008 -Apr -21 17:19:30 ACK C:1D0armenls and Set6ngsWeWdro CwitreraM00*tuplWrthtsW WACSAW ExpressiobN 08-0OSt.rrp Page 2 Trunk Hig C19 Design Veloc Diam Rect Duct Duct Name Type (cfm) (cfm) FR (fpm) (in) Size (in) Material Trunk rt1 Peak AVF 1000 900 0.068 474 18 8 x 38 ShtMetl rt1A Peak AVF 278 222 0.068 501 9 8 x 10 ShtMetl rti rt18 Peak AVF 135 1 118 0.068 1 406 7 8 x 6 ShtMeti rt1A AE, vvrightgp't Right-8LAteResidential6.p.51 RSR43351 2008 -Apr -21 17:19:30 ACK C:1D0armenls and Set6ngsWeWdro CwitreraM00*tuplWrthtsW WACSAW ExpressiobN 08-0OSt.rrp Page 2