HomeMy WebLinkAboutRESCHECK - 08-00207 - 1125 & 1127 S 2nd E - New SFRNjr4lGenerated by REScheck '� Compliance CE Project Title: Valley View Townhomes Report Date: 05/08/07 Energy Code: Location: 20031ECC Construction Type: Rexburg, Idaho Multifamily Glazing Area Percentage: 15% Heating Degree Days: 8693 Construction Site: Owmer/Agent 1100 South 2nd East Rexburg, Id 83440 Bart Stevens Stevens Construction Company 210 Nez Peroe Ave. Rexburg, Id 83440 208-709-7312 0800207 1125 & 1127 S 2nd E -Stevens Designer/Contractor: Stevens Construction Company 859 South Yellowstone Hyw. Suite #101 Rexburg, Id 83440 208-709-7312 Basement: 21.0 0.0 Wall height: 8.0' 19.0 Depth below grade. 5.0' Insulation depth: 8.0' Window: Door. 0.350 Floor: 0.350 Furnace: 92 AFUE 19.0 Air Conditioner: 10 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The Proposed building has been designed to meet the 2003 IECC requirements in the REScheck Package Generator and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date MAY - g 2007 IL CITY OF REXBURG Valley View Townhomes Page 1 of 4 Generated by REScheck Package Generator Inspection Checklist Date: 05/08/07 Ceilings: ❑ Ceiling: R-49.0 cavity insulation Comments: Note. The ceiling R -values do not assume a raised or oversized truss construction. If the insulation achieves the full insulation thickness over the plate lines of exterior walls, R-30 insulation may be substituted for R-38 insulation and R-38 insulation may be substituted for R-49 insulation. Ceiling R -values represent the sum of cavity insulation plus insulating sheathing (if used). Alcove -Grade Walls: ❑ Wall: R-21.0 cavity insulation Comments: Note: Wall requirements apply to wood -frame wall constructions. Metal -frame wall or mass (concrete, masonry, log) wall equivalent R -values can be found in the Help User's Guide. Basement Walls: ❑ Basement: 8.0' ht / 5.0' bg / 8.0' insul, R-19.0 cavity insulation Comments: Note: Walls of conditioned basements below uninsulated floors must be insulated from the top of the basement wall to a depth of 10 feet below ground level or to the level of the basement floor, whichever is less. The entire opaque portion of any individual basement wall with an average depth less than 50% below grade must meet the same R -value requirement as above -grade walls. Basement doors must meet the door -U -factor requirement. Windows: ❑ Window: U factor 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Note: Up to 1 % of the total allowed glazing area may be excluded from the U -value requirement. For example, 3 ft2 of decorative glass may be excluded from a building design with 300 ft2 of glazing area. Doors: ❑ Door. U -factor. 0.350 Comments: Front door exempt Note: Door U values must be tested and documented by the manufacturer in accordance with the NFRC test procedure or taken from the door U factor table in the Help Users Guide. If a door contains glass and an aggregate U -factor rating for that door is not available, include the glass area of the door with your windows and use the opaque door U -factor to determine compliance for the door. One door may be excluded from this requirement (i.e., may hav a U -factor greater than 0.35). Floors: ❑ Floor: R-19.0 cavity insulation Comments: Note: The floor requirements apply to floors over unconditioned spaces (such as unconditioned crawlspaces, basements or garages). Floors over outside air must meet the ceiling requirements. Note: Add an additional R-2 for heated slabs. The insulation must extend 1) down from the top of the slab, or 2) down from the top of the slab to the bottom of the slab and then horizontally underneath the slab, or 3) down from the top of the slab to the bottom of the slab and then horizontally away from the slab, with pavement or at least 10 inches of soil covering the horizontal insulation. Heating and Cooling Equipment: ❑ Furnace:: 92 AFUE or higher Valley View Townhomes Page 2 of 4 Make and Model Number. ❑ Air Conditioner, : 10 SEER or higher Make and Model Number. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -fight assembly with a 0.5" clearance from combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: ❑ Installed on the warm -in -winter side of all non -vented framed ceilings, walls, and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R -values, glazing U -factors, and heating equipment efficiency are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the insulation. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building are insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building are insulated to R-6. ❑ Supply ducts in unconditioned spaces are insulated to R-11. ❑ Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements. 0 Where exterior walls are used as plenums, the wall is insulated to R-11. Duct Construction: ❑ Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened. ❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181B. Exceptions: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Thermostats exist for each dwelling unit (non -dwelling areas must have one thermostat for each system or zone). A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each room is provided. Electric Systems: ❑ Separate electric meters exist for each dwelling unit. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. 0 Cifrulatina hot water pipes are insulated t. tha 10—IQ in Table 1. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: ❑ Al heated swimming pools have an onloff heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Valley View Townhomes Page 3 of 4 f Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating ---m- s Circulating Mains and Runouts Temperature ('F) U Rto 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 140-169 0.5 0.5 1.0 1.5 2.0 100-139 0.5 0.5 0.5 1.0 1.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes NOTES TO FIELD: (Building Department Use Only) Valley View Townhomes Page 4 of 4 Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 - Steam Condensate (for feed water) Any 1.0 1.0 1.5 Cooling Systems 2.0 Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Valley View Townhomes Page 4 of 4