Compliance Certificate
Project Title: The Meadows Townhomes
Report Date: 03/28/07
Data filename: C:1Documents and Settings\Chds Jaussi\My Documents\PROJECTS\REXBURG MEADOWS\New Townhome Res
Check. rck
Energy Code:
2000 IECC
Location:
Rexburg, Idaho
Construction Type:
Multifamily
Glazing Area Percentage:
13%
Heating Degree Days:
8693
Construction Site:
Owner/Agent:
Countryside Avenue
Chris Jaussi
Rexburg, ID 83440
Timberhawk Inc.
P.O. Box 665 "
Vernal, UT 84078
(435) 790-8194
chrisj@timberhawk.com
Designer/Contractor:
Tim Jessop
jessop design group, inc.
P.O. Box 65711
Salt Lake City, UT 84078
(801) 598-1050
The Meadows Townhomes
Page 1 of 4
4
Duct Insulation:
❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0.
Duct Construction:
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each dwelling unit (non -dwelling areas must have one thermostat for each system or zone). A
manual or automatic means to partially restrict or shut off the heating and/or cooling input to each room shall be provided.
Electric Systems:
❑ Separate electric meters are required for each dwelling unit.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑' Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
The Meadows Townhomes
Page 3 of 4
RESIDENTIAL PLAN CHECKLIST
(2003 International Residential Code)
Date: " ( —O'z Building Permit Number: & 7 –C7e,p T,3
Project: n'taQ(.
_ Job Address:
Zoning: Number of Stories: Basement: YesiN / 2
y Fug--i�rt?rii. Fixtures 7
(Note unfinished basements as special condition on permit)
aloorArea (sf): "'ZN finished, unfinished, "-garage Mechanical Fee:
The following comments based on the 2003 edition of the International Residential Code should be resolved
before a building permit is issued. This correction list is not a building permit. The approval of plans and
specifications does. notpermit the violation of any section ofthe International Residential Code or any federal,
state or local reguations.
PLAN CHECK
rans
/ScaleZLible
� Plot Plan Y / N Flood Plain
Floor / Foundation Plan
Z�e-tion showing construction details
.1All Building Elevations
�D�esign Criteria (shall be identified on plans as Wind - 85 m.p.h., Snow - 35 lb. Per sq ft.)
S 1truss Calculation Sheetsloor Joist Details
M chanical Design
TAnergy Calculations (R320 & Ch 11)
B. Zoning (circle one –new zoning designations adopted in 2005)
LDRI 12,000 sfmin. (width 80 ft. min)
LDR2 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P.
RR2 21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P.
Other (Verify zoning requirements)
C. e
Single Family _Duplex (LDRI only -�Cer
p
Conditional use n2iM
D. Set Backs (taken from eaves) 0 cA9! . p2 'Z Oji -GF. Itxn,�
"'Front set back (32 ft. from curb) I ..! Note: 60% min of front yard green
—Rear set back (LDRI 25 ft. & LDR2 20 ft.)
SiSides set backs (6" for every ft. of building height with LDR - 7.5' min., & LDRI - 6' min.)
.✓ Building -Height (maximum 30 ft.)
E. Footings
roper Size (as per Table 403. 1, use 1500 psf unless soil type is known, Table 401.4:1 for soil bearing)
Rebar (244 continuous)
Footing Depth (36below finished grade and 12" below undisturbed soil; 18" to top of slab –interior)
F. /Foundation
! Foundation walls w/ rebar (city ordinance)_
"'�'1/2" Anchor Bolts with 2"x 2"x 3/16" square washers (incl. interior bearing walls) R403.1.6.1
Foundation Drainage (foundations on sift soil shall be designed per R405)
amp proofing/Waterproofing to finish grade. R406.1(fnd. extends 6" min above grade X404.1.6)
/Crawl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.4)
-Crawl Space Ventilation/Insulation =1 sf vent per 150 sf, iwith moisture barrier 1 sf per 1500 sq ft.) and
within 3' of each corner (insulate walls vent to inside of home) R408.2
_Grading slope away from house. R401.3
iaG. F me
smic Hold Downs and Braced Wall Panels (8602.10)
Floors joists sized as per R502.3, Wood 1 -joists sized per manufr.
Joists Under Load Bearing Partitions shall be doubled. R502.4
Girders sized.per 8502.5 or per manufr. Tables for engineered products
Cant
ilevers (comply with R502.3.3 or manufr instruction)