HomeMy WebLinkAboutRESCHECK - 08-00200 - The Meadows - Phase 3 - Bldg 13, 4 UnitsProject Title: The Meadows Townhomes
Report Date: 03/28/07
Data filename: C:\Documents and Settings\Chris Jaussi\My Documents\PROJECTS\REXBURG MEADOWS\New Townhome Res
Check. rck
Energy Code:
2000 IECC
Location:
Rexburg, Idaho
Construction Type:
Multifamily
Glazing Area Percentage:
13%
Heating Degree Days:
8693
Construction Site:
Owner/Agent:
Designer/Contractor:
Countryside Avenue
Chris Jaussi
Tim Jessop
Rexburg, ID 83440
Timberhawk Inc.
jessop design group, inc.
P.O. Box 665
P.O. Box 65711
Vernal„ UT 84078
Salt Lake City, UT 84078
(435) 790-8194
(801) 598-1050
chrisj@timberhawk.com
Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Company Name Date
The Meadows Townhomes
Page 1 of 4
1
Duct Insulation:
❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0.
Duct Construction:
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181 A or UL 1818.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each dwelling unit (non -dwelling areas must have one thermostat for each system or zone). A
manual or automatic means to partially restrict or shut off the heating and/or cooling input to each room shall be provided.
Electric Systems:
❑ Separate electric meters are required for each dwelling unit.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2
The Meadows Townhomes Page 3 of 4
RESIDENTIAL PLAN CHECKLIST
CJ e
(2003 International Residential Code)
Single Family Duplex (LDRI only -.Conditional use permit?)
t��.�,
D. Set Backs (taken from eaves)' -f� F'? 2 S� bG ��^^ -
Date: 5 Z- "y Z Building Permit Number: a' 7 -'e)o0 `73
'—Front set back (32 ft. from curb) e-- Note: 60%o min of front yard green
Y,
Project: '�A Cn 77S Job Address:
Rear set back (LDR1 25 ft. & LDR2 20 ft.)
Zoning: Number of Stories: Basement: YeSO/Fisq- n, Fixtures:
_Sides set backs (6" for every ft. of building height with LDR - 7.5' min., & LDRI - 6' min.)
(Note unfinished basements as special condition on permit)
*
,/Building -Height (maximum 30 ft.) ,
loon Area (sf): •7t4finished, unfinished, garage Mechanical Fee:
-
E. Footings
Zp-roper Size (as per Table 403. 1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing)
The following comments based on the 2003 edition of the International Residential Code should be resolved
before a building permit is issued. This correction list is not a building permit. The approval of plans and
Rebar (244 continuous)
specifications does not permit the violation of any section of the International Residential Code or any federal,
state or local regulations.Footing
Depth (3'6" below finished grade and 12" below undisturbed soil; 18" to top of slab - interior)
PLAN CHECI{
F. Foundation
"Foundation walls w/ rebar (city ordinance)
A. ans
Scale Legible
-""l/2" Anchor Bolts with 2"x 2"x 3/16" square washers (incl. interior bearing walls) R403.1.6.1
,/
Foundation Drainage (foundations on sift soil shall be designed per R405)
/Plot Plan YY / NN Flood Plain
Damp proofing/Waterproofing to finish grade. R406.1 (Ind. extends 6" min above grade R404.1.6)
Floor /Foundation Plan
/Crawl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.4)
zs-.tion showing construction details
Crawl Space Ventilation/Insulation =1 sf vent per 150 s£ (with moisture barrier 1 sf. per 1500 sq ft.) and
� All Building Elevations
within T of each corner (insulate walls vent to inside of home l R408.2
Design Criteria (shall be identified on plans as Wind - 85 m.p.h., Snow - 35 lb. Per sq ft.)
from house. R401.3
door
_Grading slope away
Qruss Calculation Sheets Joist Details
G. F ame
Hold Downs and Braced Wall Panels (8602;10)
iM chanical Designeismic
Floors joists sized as per 8502.3, Wood I jrists sized per manufr.
ergy Calculations (R320 & Ch 11)
�ists Under Load Bearing Partitions shall be doubled. R502.4
B. Zoning (circle one -new zoning designations adopted in 2005)
LDRI 12,OOd sf min. (width 80 ft. min)
sized per R502.5 or per manufr. Tables for engineered products
LDR2 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft, min. with C.U.P.
RR2 21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P.
_/Girders
/
/Cantilevers
Other (Verify zoning requirements)
— (comply with R502.3.3 or manufr instruction)