Loading...
HomeMy WebLinkAboutTRUSS PLANS - 20-00886 - 859 Pine Brook - Faires - New SFRPB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :M7, M8, M9 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL U* 131 /- /- /39 /9 /8 Wind reactions based on MWFRS U Brg Width = 444 Min Req = - Bearing B Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 54 0 B - C 133 -190 C - D 129 -165 D - E 121 -143 E - F 114 -120 F - G 105 -97 G - H 117 -81 H - I 160 -79 I - J 206 -84 J - K 251 -98 K - L 251 -98 Chords Tens. Comp. L - M 206 -84 M - N 160 -79 N - O 117 -81 O - P 73 -82 P - Q 75 -64 Q - R 72 -84 R - S 83 -104 S - T 90 -126 T - U 94 -150 U - V 54 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -AO 177 -136 AO-AN 178 -137 AN-AM 178 -139 AM-AL 178 -140 AL-AK 178 -140 AK-AJ 178 -141 AJ-AI 166 -109 AI-AH 167 -109 AH-AG 167 -109 AG-AF 168 -108 Chords Tens. Comp. AF-AE 168 -108 AE-AD 167 -108 AD-AC 167 -108 AC-AB 167 -108 AB-AA 166 -107 AA- Z 166 -107 Z - Y 165 -106 Y - X 164 -105 X - W 163 -104 W - U 161 -102 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AO 65 -200 D -AN 65 -216 E -AM 62 -216 F -AL 63 -231 G -AK 63 -237 H -AI 62 -242 I -AH 66 -256 J -AG 65 -296 K -AF 0 -219 Gables Tens. Comp. AE- L 65 -296 AD- M 66 -256 AB- N 62 -242 AA- O 63 -238 Z - P 63 -227 Y - R 63 -222 X - S 64 -214 W - T 66 -200 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.002 J 999 240 VERT(CL): 0.004 J 999 180 HORZ(LL): 0.003 N - - HORZ(TL): 0.005 N - - Creep Factor: 2.0 Max TC CSI: 0.101 Max BC CSI: 0.034 Max Web CSI: 0.187 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:A1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259986 / T8 / GABL FROM:DRW: ... / ... 02/04/2020 M7 M8 M9 M8 M7 (a) (a)(a) (a) (a) A B C D E F G H I J K L M N O PQ R S T U V WXYZAAABACADAEAFAGAHAIAJAKALAMANAO 7 12 3X6(B1T) 5X6 3X6 5X6 3X6 3X6(**) 3X6(B1T) 37' 2'6"2'(TYP) 18'6" 18'6" 37' 18'6" 37' 37'1'1' 4-5/16" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :M7, M8, M9 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL U* 131 /- /- /39 /9 /8 Wind reactions based on MWFRS U Brg Width = 444 Min Req = - Bearing B Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 54 0 B - C 133 -190 C - D 129 -165 D - E 121 -143 E - F 114 -120 F - G 105 -97 G - H 117 -81 H - I 160 -79 I - J 206 -84 J - K 251 -98 K - L 251 -98 Chords Tens. Comp. L - M 206 -84 M - N 160 -79 N - O 117 -81 O - P 73 -82 P - Q 75 -64 Q - R 72 -84 R - S 83 -104 S - T 90 -126 T - U 94 -150 U - V 54 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -AO 177 -136 AO-AN 178 -137 AN-AM 178 -139 AM-AL 178 -140 AL-AK 178 -140 AK-AJ 178 -141 AJ-AI 166 -109 AI-AH 167 -109 AH-AG 167 -109 AG-AF 168 -108 Chords Tens. Comp. AF-AE 168 -108 AE-AD 167 -108 AD-AC 167 -108 AC-AB 167 -108 AB-AA 166 -107 AA- Z 166 -107 Z - Y 165 -106 Y - X 164 -105 X - W 163 -104 W - U 161 -102 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AO 65 -200 D -AN 65 -216 E -AM 62 -216 F -AL 63 -231 G -AK 63 -237 H -AI 62 -242 I -AH 66 -256 J -AG 65 -296 K -AF 0 -219 Gables Tens. Comp. AE- L 65 -296 AD- M 66 -256 AB- N 62 -242 AA- O 63 -238 Z - P 63 -227 Y - R 63 -222 X - S 64 -214 W - T 66 -200 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.002 J 999 240 VERT(CL): 0.004 J 999 180 HORZ(LL): 0.003 N - - HORZ(TL): 0.005 N - - Creep Factor: 2.0 Max TC CSI: 0.101 Max BC CSI: 0.034 Max Web CSI: 0.187 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:A1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259986 / T8 / GABL FROM:DRW: ... / ... 02/04/2020 M7 M8 M9 M8 M7 (a) (a)(a) (a) (a) A B C D E F G H I J K L M N O PQ R S T U V WXYZAAABACADAEAFAGAHAIAJAKALAMANAO 7 12 3X6(B1T) 5X6 3X6 5X6 3X6 3X6(**) 3X6(B1T) 37' 2'6"2'(TYP) 18'6" 18'6" 37' 18'6" 37' 37'1'1' 4-5/16" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W3, W4 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2030 /- /- /768 /141 /253 J 2030 /- /- /768 /141 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.2 J Brg Width = 5.5 Min Req = 2.2 Bearings B & J Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 48 0 B - C 447 -3241 C - D 434 -2899 D - E 458 -2819 E - F 393 -2056 Chords Tens. Comp. F - G 394 -2056 G - H 457 -2819 H - I 434 -2899 I - J 447 -3241 J - K 48 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 2688 -292 P - O 2182 -170 O - N 2182 -170 Chords Tens. Comp. N - M 2182 - 171 M - L 2182 - 171 L - J 2688 - 296 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - P 150 -474 P - E 555 -82 E - N 202 -929 F - N 1402 -271 Webs Tens. Comp. N - G 202 -929 G - L 555 -82 L - I 150 -474 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.169 N 999 240 VERT(CL): 0.250 N 999 180 HORZ(LL): 0.075 L - - HORZ(TL): 0.111 L - - Creep Factor: 2.0 Max TC CSI: 0.541 Max BC CSI: 0.572 Max Web CSI: 0.435 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:A2 Ply: 1 Qty: 6 Wgt: 0.0 lbs SEQN: 259959 / T5 / COMN FROM:DRW: ... / ... 02/04/2020 W3 W4 W3 (a)(a) A B C D E F G H I J K LMNOP 7 12 3X12(B3T) 2X4 3X6 3X6 3X6 3X6 5X6 3X12 3X6 3X6 3X6 3X6 2X4 3X12(B3T) 37' 6'5-11/16" 6'5-11/16" 12'5-7/8" 6'0-1/8" 18'6" 6'0-1/8" 24'6-1/8" 6'0-1/8" 30'6-5/16" 6'0-1/8" 37' 6'5-11/16" 9'5-13/16" 9'5-13/16" 18'6" 9'0-3/16" 27'6-3/16" 9'0-3/16" 37' 9'5-13/16"1'1' 4-5/16" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W3, W4 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2030 /- /- /768 /141 /253 J 2030 /- /- /768 /141 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.2 J Brg Width = 5.5 Min Req = 2.2 Bearings B & J Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 48 0 B - C 447 -3241 C - D 434 -2899 D - E 458 -2819 E - F 393 -2056 Chords Tens. Comp. F - G 394 -2056 G - H 457 -2819 H - I 434 -2899 I - J 447 -3241 J - K 48 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 2688 -292 P - O 2182 -170 O - N 2182 -170 Chords Tens. Comp. N - M 2182 - 171 M - L 2182 - 171 L - J 2688 - 296 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - P 150 -474 P - E 555 -82 E - N 202 -929 F - N 1402 -271 Webs Tens. Comp. N - G 202 -929 G - L 555 -82 L - I 150 -474 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.169 N 999 240 VERT(CL): 0.250 N 999 180 HORZ(LL): 0.075 L - - HORZ(TL): 0.111 L - - Creep Factor: 2.0 Max TC CSI: 0.541 Max BC CSI: 0.572 Max Web CSI: 0.435 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:A2 Ply: 1 Qty: 6 Wgt: 0.0 lbs SEQN: 259959 / T5 / COMN FROM:DRW: ... / ... 02/04/2020 W3 W4 W3 (a)(a) A B C D E F G H I J K LMNOP 7 12 3X12(B3T) 2X4 3X6 3X6 3X6 3X6 5X6 3X12 3X6 3X6 3X6 3X6 2X4 3X12(B3T) 37' 6'5-11/16" 6'5-11/16" 12'5-7/8" 6'0-1/8" 18'6" 6'0-1/8" 24'6-1/8" 6'0-1/8" 30'6-5/16" 6'0-1/8" 37' 6'5-11/16" 9'5-13/16" 9'5-13/16" 18'6" 9'0-3/16" 27'6-3/16" 9'0-3/16" 37' 9'5-13/16"1'1' 4-5/16" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W3, W4, W5 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2510 /- /- /877 /179 /291 AD 3448 /- /- /1240 /209 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.7 AD Brg Width = 5.5 Min Req = 3.3 Bearings B & AD Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 54 0 B - C 514 -4057 C - D 543 -3998 D - E 570 -3931 E - F 550 -3676 F - G 580 -3648 G - H 587 -3597 H - I 615 -3582 I - J 467 -2722 J - K 498 -2644 K - L 528 -2581 L - M 469 -2145 M - N 469 -2143 Chords Tens. Comp. N - O 469 -2143 O - P 469 -2144 P - Q 476 -2164 Q - R 443 -2206 R - S 413 -2290 S - T 295 -1062 T - U 268 -1158 U - V 226 -1064 V - W 223 -1179 W - X 876 -283 X - Y 853 -309 Y - Z 785 -327 Z -AA 55 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -AZ 3403 -378 AZ-AY 3397 -376 AY-AX 3395 -375 AX-AW 3389 -374 AW-AV 3389 -374 AV-AU 2865 -246 AU-AT 2865 -246 AT-AS 2861 -245 AS-AR 2861 -245 AR-AQ 2861 -245 AQ-AP 2861 -245 AP-AO 2231 -107 AO-AN 2231 -107 Chords Tens. Comp. AN-AM 1860 -61 AM-AL 1860 -61 AL-AK 1519 -79 AK-AJ 1519 -79 AJ-AI 1519 -79 AI-AH 1519 -79 AH-AG 1522 -79 AG-AF 1522 -79 AF-AE 350 -607 AE-AD 350 -607 AD-AC 356 -667 AC-AB 356 -662 AB- Z 355 -657 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E -BA 102 -364 BA-BB 130 -498 Webs Tens. Comp. AN-BM 763 -117 BN- P 773 -118 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.50 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.246 AS 999 240 VERT(CL): 0.341 AS 999 180 HORZ(LL): 0.083 J - - HORZ(TL): 0.116 J - - Creep Factor: 2.0 Max TC CSI: 0.556 Max BC CSI: 0.821 Max Web CSI: 0.904 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:B1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259932 / T9 / GABL FROM: Page 1 of 2 DRW: ... / ... 02/04/2020 W3 W4 W5 W4 W5 W4 W3 (a) (a)(a)(a) (a) A B C D E F G H I J K LMNOP Q R S T UV W X Y Z AA ABACADAEAFAGAHAIAJAKALAMANAOAPAQARASATAUAVAWAXAYAZ BA BBBC BD BE BF BGBH BIBJ BK BL BM BN BOBP BQBR BS BTBU BVBW 7 12 4X8(B3T) 3X6 3X6 3X6 H0312 2X4(**) 5X8 4X6 4X8 5X8 3X6 3X6 4X6 4X8(R) 3X6 6X10 4X6 3X6(B1T) 39'6' 2'6"2'(TYP) 4'4'4' 4' 6'4-11/16" 6'4-11/16" 6'6" 1-5/16" 12'3-7/8" 5'9-7/8" 18'3" 5'11-1/8" 22'6" 4'3" 26'9" 4'3" 32'8-1/8" 5'11-1/8" 38'9-1/4" 6'1-1/8" 45' 6'2-3/4" 9'4-5/16" 9'4-5/16" 18'3" 8'10-11/16" 22'6" 4'3" 26'9" 4'3" 35'7-11/16" 8'10-11/16" 38'9-1/4" 3'1-9/16" 45' 6'2-3/4"1'1' 4-5/16" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W3, W4, W5 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2510 /- /- /877 /179 /291 AD 3448 /- /- /1240 /209 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.7 AD Brg Width = 5.5 Min Req = 3.3 Bearings B & AD Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 54 0 B - C 514 -4057 C - D 543 -3998 D - E 570 -3931 E - F 550 -3676 F - G 580 -3648 G - H 587 -3597 H - I 615 -3582 I - J 467 -2722 J - K 498 -2644 K - L 528 -2581 L - M 469 -2145 M - N 469 -2143 Chords Tens. Comp. N - O 469 -2143 O - P 469 -2144 P - Q 476 -2164 Q - R 443 -2206 R - S 413 -2290 S - T 295 -1062 T - U 268 -1158 U - V 226 -1064 V - W 223 -1179 W - X 876 -283 X - Y 853 -309 Y - Z 785 -327 Z -AA 55 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -AZ 3403 -378 AZ-AY 3397 -376 AY-AX 3395 -375 AX-AW 3389 -374 AW-AV 3389 -374 AV-AU 2865 -246 AU-AT 2865 -246 AT-AS 2861 -245 AS-AR 2861 -245 AR-AQ 2861 -245 AQ-AP 2861 -245 AP-AO 2231 -107 AO-AN 2231 -107 Chords Tens. Comp. AN-AM 1860 -61 AM-AL 1860 -61 AL-AK 1519 -79 AK-AJ 1519 -79 AJ-AI 1519 -79 AI-AH 1519 -79 AH-AG 1522 -79 AG-AF 1522 -79 AF-AE 350 -607 AE-AD 350 -607 AD-AC 356 -667 AC-AB 356 -662 AB- Z 355 -657 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E -BA 102 -364 BA-BB 130 -498 Webs Tens. Comp. AN-BM 763 -117 BN- P 773 -118 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.50 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.246 AS 999 240 VERT(CL): 0.341 AS 999 180 HORZ(LL): 0.083 J - - HORZ(TL): 0.116 J - - Creep Factor: 2.0 Max TC CSI: 0.556 Max BC CSI: 0.821 Max Web CSI: 0.904 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:B1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259932 / T9 / GABL FROM: Page 1 of 2 DRW: ... / ... 02/04/2020 W3 W4 W5 W4 W5 W4 W3 (a) (a)(a)(a) (a) A B C D E F G H I J K LMNOP Q R S T UV W X Y Z AA ABACADAEAFAGAHAIAJAKALAMANAOAPAQARASATAUAVAWAXAYAZ BA BBBC BD BE BF BGBH BIBJ BK BL BM BN BOBP BQBR BS BTBU BVBW 7 12 4X8(B3T) 3X6 3X6 3X6 H0312 2X4(**) 5X8 4X6 4X8 5X8 3X6 3X6 4X6 4X8(R) 3X6 6X10 4X6 3X6(B1T) 39'6' 2'6"2'(TYP) 4'4'4' 4' 6'4-11/16" 6'4-11/16" 6'6" 1-5/16" 12'3-7/8" 5'9-7/8" 18'3" 5'11-1/8" 22'6" 4'3" 26'9" 4'3" 32'8-1/8" 5'11-1/8" 38'9-1/4" 6'1-1/8" 45' 6'2-3/4" 9'4-5/16" 9'4-5/16" 18'3" 8'10-11/16" 22'6" 4'3" 26'9" 4'3" 35'7-11/16" 8'10-11/16" 38'9-1/4" 3'1-9/16" 45' 6'2-3/4"1'1' 4-5/16" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org BC-AV 129 -521 AV-BD 714 -142 BE- I 733 -145 I -BF 195 -986 BF-BG 215 -1152 BH-BI 219 -1158 BJ-AP 223 -1190 L -AP 1169 -206 L -BK 82 -517 BL-AN 68 -514 N -AN 62 -418 P -AL 228 -142 AL-BO 505 -33 BP-BQ 527 -30 BR-BS 543 -33 BS- S 660 -51 S -BT 252 -1781 BU-AF 256 -1798 AF-BV 2324 -314 BW- W 2305 -305 W -AD 487 -3057 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AZ 49 -103 D -AY 45 -83 AX-BA 187 -37 BB- F 58 -240 AW-BC 50 -208 BD-AU 42 -102 H -BE 43 -122 AT-BF 220 -26 BG- J 53 -118 AS-BH 45 -107 BI- K 45 -147 AQ-BJ 42 -107 BK- M 43 -152 AO-BL 42 -126 Gables Tens. Comp. BM-AM 45 -153 O -BN 45 -168 BO-AK 46 -147 Q -BP 49 -186 BQ-AJ 45 -91 R -BR 53 -107 BS-AH 202 -23 BT- T 40 -91 AG-BU 41 -70 BV-AE 63 -266 U -BW 60 -261 AC- X 51 -169 AB- Y 51 -86 Job Number:PB201526 FAIRES Truss Label:B1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259932 / T9 / GABL FROM: Page 2 of 2 DRW: ... / ... 02/04/2020 PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L #1&Bet. :W1, W2, W6, W7 2x4 DF-L Stud: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2408 /- /- /824 /150 /258 N 3287 /- /- /1174 /169 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.6 N Brg Width = 5.5 Min Req = 3.1 Bearings B & N Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 48 0 B - C 490 -3982 C - D 484 -3623 D - E 501 -3416 E - F 443 -2514 F - G 411 -1813 Chords Tens. Comp. G - H 411 -1813 H - I 397 -2115 I - J 235 -1136 J - K 211 -1251 K - L 866 -294 L - M 49 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - U 3330 -333 U - T 2728 -215 T - S 2728 -215 S - R 1972 -87 R - Q 1631 -47 Chords Tens. Comp. Q - P 1490 - 75 P - O 1490 - 75 O - N 316 -560 N - L 322 -612 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - U 147 -579 U - E 635 -78 E - S 203 -1179 F - S 1030 -124 F - R 66 -524 G - R 79 -622 Webs Tens. Comp. R - H 652 -109 H - Q 114 -225 Q - I 466 -23 I - O 263 -1657 O - K 2094 - 247 K - N 474 -3170 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.50 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.185 E 999 240 VERT(CL): 0.257 E 999 180 HORZ(LL): 0.076 O - - HORZ(TL): 0.105 O - - Creep Factor: 2.0 Max TC CSI: 0.775 Max BC CSI: 0.650 Max Web CSI: 0.938 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:B2 Ply: 1 Qty: 5 Wgt: 0.0 lbs SEQN: 259922 / T11 / COMN FROM:DRW: ... / ... 02/04/2020 W1 W2 W2 W6 W7 (a) (a)(a)(a) (a) A B C D E FGH I J K L M NOPQRSTU 7 12 4X8(B3T) 2X4 3X6 3X6 3X6 H0312 5X8 3X6 2X4 4X8 5X8 3X6 3X6 3X12 4X8(R) 3X6 6X10 4X6 3X6(B1T) 39'6' 6'4-11/16" 6'4-11/16" 12'3-7/8" 5'11-1/8" 18'3" 5'11-1/8" 22'6" 4'3" 26'9" 4'3" 32'8-1/8" 5'11-1/8" 38'9-1/4" 6'1-1/8" 45' 6'2-3/4" 9'4-5/16" 9'4-5/16" 18'3" 8'10-11/16" 22'6" 4'3" 26'9" 4'3" 35'7-11/16" 8'10-11/16" 38'9-1/4" 3'1-9/16" 45' 6'2-3/4"1'1' 4-5/16" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L #1&Bet. :W1, W2, W6, W7 2x4 DF-L Stud: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2408 /- /- /824 /150 /258 N 3287 /- /- /1174 /169 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.6 N Brg Width = 5.5 Min Req = 3.1 Bearings B & N Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 48 0 B - C 490 -3982 C - D 484 -3623 D - E 501 -3416 E - F 443 -2514 F - G 411 -1813 Chords Tens. Comp. G - H 411 -1813 H - I 397 -2115 I - J 235 -1136 J - K 211 -1251 K - L 866 -294 L - M 49 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - U 3330 -333 U - T 2728 -215 T - S 2728 -215 S - R 1972 -87 R - Q 1631 -47 Chords Tens. Comp. Q - P 1490 - 75 P - O 1490 - 75 O - N 316 -560 N - L 322 -612 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - U 147 -579 U - E 635 -78 E - S 203 -1179 F - S 1030 -124 F - R 66 -524 G - R 79 -622 Webs Tens. Comp. R - H 652 -109 H - Q 114 -225 Q - I 466 -23 I - O 263 -1657 O - K 2094 - 247 K - N 474 -3170 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.50 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.185 E 999 240 VERT(CL): 0.257 E 999 180 HORZ(LL): 0.076 O - - HORZ(TL): 0.105 O - - Creep Factor: 2.0 Max TC CSI: 0.775 Max BC CSI: 0.650 Max Web CSI: 0.938 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:B2 Ply: 1 Qty: 5 Wgt: 0.0 lbs SEQN: 259922 / T11 / COMN FROM:DRW: ... / ... 02/04/2020 W1 W2 W2 W6 W7 (a) (a)(a)(a) (a) A B C D E FGH I J K L M NOPQRSTU 7 12 4X8(B3T) 2X4 3X6 3X6 3X6 H0312 5X8 3X6 2X4 4X8 5X8 3X6 3X6 3X12 4X8(R) 3X6 6X10 4X6 3X6(B1T) 39'6' 6'4-11/16" 6'4-11/16" 12'3-7/8" 5'11-1/8" 18'3" 5'11-1/8" 22'6" 4'3" 26'9" 4'3" 32'8-1/8" 5'11-1/8" 38'9-1/4" 6'1-1/8" 45' 6'2-3/4" 9'4-5/16" 9'4-5/16" 18'3" 8'10-11/16" 22'6" 4'3" 26'9" 4'3" 35'7-11/16" 8'10-11/16" 38'9-1/4" 3'1-9/16" 45' 6'2-3/4"1'1' 4-5/16" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T2 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. :B1 2x4 DF-L 2400f-2.0E: Webs 2x4 DF-L #1&Bet. :W1, W3, W4, W9, W10, M1 2x4 DF-L Stud: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2434 /- /- /876 /183 /291 Q* 458 /- /- /165 /27 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.4 Q Brg Width = 101 Min Req = - Bearings B & Q Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 68 0 B - C 874 -5719 C - D 896 -5678 D - E 1083 -6332 E - F 584 -3536 F - G 596 -3336 G - H 470 -2324 Chords Tens. Comp. H - I 412 -1610 I - J 412 -1610 J - K 361 -1513 K - L 1428 - 310 L - M 1172 - 321 M - N 978 -332 N - O 55 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - X 5369 -792 X - W 5364 -789 W - V 3453 -401 V - U 2583 -223 U - T 2583 -223 Chords Tens. Comp. T - S 1855 - 130 S - R 1135 - 135 R - Q 310 -252 Q - P 310 -252 P - N 725 -1354 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - W 381 -1759 W - E 2744 -558 E - V 260 -1140 V - G 1209 -201 G - T 281 -1370 H - T 1205 -201 H - S 115 -807 Webs Tens. Comp. I - S 93 -625 S - J 1284 - 202 J - R 175 -1210 R - K 1475 - 188 K - P 571 -3412 P - M 186 -672 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C - X 55 -104 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.313 E 999 240 VERT(CL): 0.440 E 868 180 HORZ(LL): 0.080 D - - HORZ(TL): 0.111 D - - Creep Factor: 2.0 Max TC CSI: 0.943 Max BC CSI: 0.699 Max Web CSI: 0.936 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:C1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259905 / T2 / GABL FROM:DRW: ... / ... 02/04/2020 T2 B1 W1 W3 W4 W9 W10 M1 (a) (a)(a)(a)(a) (a) A B C D E F G HIJ K L M N O PQRSTUVWX 4 12 7 12 3X12(B6RT) 8X8(R) 5X8 4X12 4X6(R) H0312 4X6 H0312 5X8 4X6 5X8 5X8 4X6 H0312 6X10 5X6(R) 3X6 3X6(B1T) 40'7' 2'6" 2'6" 4'6-9/16" 2'0-9/16"9'9-3/8" 5'2-13/16" 15'0-3/16" 5'2-13/16" 20'3" 5'2-13/16" 24'6" 4'3" 28'9" 4'3" 34'8-1/8" 5'11-1/8" 40'7-5/16" 5'11-1/8" 47' 6'4-11/16" 2'6" 2'6" 4'6-9/16" 2'0-9/16"12'4-3/4" 7'10-1/4" 20'3" 7'10-1/4" 24'6" 4'3" 28'9" 4'3" 37'7-11/16" 8'10-11/16" 47' 9'4-5/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T2 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. :B1 2x4 DF-L 2400f-2.0E: Webs 2x4 DF-L #1&Bet. :W1, W3, W4, W9, W10, M1 2x4 DF-L Stud: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2434 /- /- /876 /183 /291 Q* 458 /- /- /165 /27 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.4 Q Brg Width = 101 Min Req = - Bearings B & Q Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 68 0 B - C 874 -5719 C - D 896 -5678 D - E 1083 -6332 E - F 584 -3536 F - G 596 -3336 G - H 470 -2324 Chords Tens. Comp. H - I 412 -1610 I - J 412 -1610 J - K 361 -1513 K - L 1428 - 310 L - M 1172 - 321 M - N 978 -332 N - O 55 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - X 5369 -792 X - W 5364 -789 W - V 3453 -401 V - U 2583 -223 U - T 2583 -223 Chords Tens. Comp. T - S 1855 - 130 S - R 1135 - 135 R - Q 310 -252 Q - P 310 -252 P - N 725 -1354 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - W 381 -1759 W - E 2744 -558 E - V 260 -1140 V - G 1209 -201 G - T 281 -1370 H - T 1205 -201 H - S 115 -807 Webs Tens. Comp. I - S 93 -625 S - J 1284 - 202 J - R 175 -1210 R - K 1475 - 188 K - P 571 -3412 P - M 186 -672 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C - X 55 -104 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.313 E 999 240 VERT(CL): 0.440 E 868 180 HORZ(LL): 0.080 D - - HORZ(TL): 0.111 D - - Creep Factor: 2.0 Max TC CSI: 0.943 Max BC CSI: 0.699 Max Web CSI: 0.936 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:C1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259905 / T2 / GABL FROM:DRW: ... / ... 02/04/2020 T2 B1 W1 W3 W4 W9 W10 M1 (a) (a)(a)(a)(a) (a) A B C D E F G HIJ K L M N O PQRSTUVWX 4 12 7 12 3X12(B6RT) 8X8(R) 5X8 4X12 4X6(R) H0312 4X6 H0312 5X8 4X6 5X8 5X8 4X6 H0312 6X10 5X6(R) 3X6 3X6(B1T) 40'7' 2'6" 2'6" 4'6-9/16" 2'0-9/16"9'9-3/8" 5'2-13/16" 15'0-3/16" 5'2-13/16" 20'3" 5'2-13/16" 24'6" 4'3" 28'9" 4'3" 34'8-1/8" 5'11-1/8" 40'7-5/16" 5'11-1/8" 47' 6'4-11/16" 2'6" 2'6" 4'6-9/16" 2'0-9/16"12'4-3/4" 7'10-1/4" 20'3" 7'10-1/4" 24'6" 4'3" 28'9" 4'3" 37'7-11/16" 8'10-11/16" 47' 9'4-5/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T2 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W5, W6, W7, W8 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2642 /- /- /881 /166 /258 O 3464 /- /- /1248 /173 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.8 O Brg Width = 5.5 Min Req = 3.3 Bearings B & O Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 68 0 B - C 847 -6337 C - D 1025 -6991 D - E 563 -3801 E - F 573 -3592 F - G 463 -2427 G - H 416 -1734 Chords Tens. Comp. H - I 416 -1734 I - J 390 -1947 J - K 196 -621 K - L 171 -667 L - M 1013 - 319 M - N 49 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - W 5935 -757 W - V 3742 -395 V - U 2744 -236 U - T 2744 -236 T - S 1945 -100 Chords Tens. Comp. S - R 1493 - 42 R - Q 1142 - 104 Q - P 1142 - 104 P - O 343 -643 O - M 348 -691 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - W 370 -1918 W - D 2921 -508 D - V 232 -1179 V - F 1248 -177 F - T 249 -1394 G - T 1236 -174 G - S 70 -671 Webs Tens. Comp. H - S 80 -619 S - I 817 -145 I - R 140 -434 R - J 737 -75 J - P 322 -2046 P - L 2140 - 248 L - O 484 -3295 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, 18SS, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.370 D 999 240 VERT(CL): 0.512 D 928 180 HORZ(LL): 0.097 C - - HORZ(TL): 0.135 C - - Creep Factor: 2.0 Max TC CSI: 0.864 Max BC CSI: 0.975 Max Web CSI: 0.977 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:C2 Ply: 1 Qty: 7 Wgt: 0.0 lbs SEQN: 259912 / T10 / COMN FROM:DRW: ... / ... 02/04/2020 T2 W5 W6 W7 W6 W7 W6 W8 (a) (a)(a)(a) (a) (a) A B C D E F GH I J K L M N OPQRSTUVW 4 12 7 12 4X12(B7RT) SS0514 5X8 6X10(R) 4X6(R) H0312 4X6 H0312 5X8 4X6 2X4 4X8 5X8 3X6 H0312 4X8 4X8(R) 3X6 6X10 4X6 3X6(B1T) 40'7' 4'6-9/16" 4'6-9/16" 9'9-3/8" 5'2-13/16" 15'0-3/16" 5'2-13/16" 20'3" 5'2-13/16" 24'6" 4'3" 28'9" 4'3" 34'8-1/8" 5'11-1/8" 39'9-1/4" 5'1-1/8" 47' 7'2-3/4" 4'6-9/16" 4'6-9/16" 12'4-3/4" 7'10-1/4" 20'3" 7'10-1/4" 24'6" 4'3" 28'9" 4'3" 37'7-11/16" 8'10-11/16" 39'9-1/4" 2'1-9/16" 47' 7'2-3/4"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T2 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W5, W6, W7, W8 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2642 /- /- /881 /166 /258 O 3464 /- /- /1248 /173 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.8 O Brg Width = 5.5 Min Req = 3.3 Bearings B & O Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 68 0 B - C 847 -6337 C - D 1025 -6991 D - E 563 -3801 E - F 573 -3592 F - G 463 -2427 G - H 416 -1734 Chords Tens. Comp. H - I 416 -1734 I - J 390 -1947 J - K 196 -621 K - L 171 -667 L - M 1013 - 319 M - N 49 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - W 5935 -757 W - V 3742 -395 V - U 2744 -236 U - T 2744 -236 T - S 1945 -100 Chords Tens. Comp. S - R 1493 - 42 R - Q 1142 - 104 Q - P 1142 - 104 P - O 343 -643 O - M 348 -691 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - W 370 -1918 W - D 2921 -508 D - V 232 -1179 V - F 1248 -177 F - T 249 -1394 G - T 1236 -174 G - S 70 -671 Webs Tens. Comp. H - S 80 -619 S - I 817 -145 I - R 140 -434 R - J 737 -75 J - P 322 -2046 P - L 2140 - 248 L - O 484 -3295 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, 18SS, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.370 D 999 240 VERT(CL): 0.512 D 928 180 HORZ(LL): 0.097 C - - HORZ(TL): 0.135 C - - Creep Factor: 2.0 Max TC CSI: 0.864 Max BC CSI: 0.975 Max Web CSI: 0.977 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:C2 Ply: 1 Qty: 7 Wgt: 0.0 lbs SEQN: 259912 / T10 / COMN FROM:DRW: ... / ... 02/04/2020 T2 W5 W6 W7 W6 W7 W6 W8 (a) (a)(a)(a) (a) (a) A B C D E F GH I J K L M N OPQRSTUVW 4 12 7 12 4X12(B7RT) SS0514 5X8 6X10(R) 4X6(R) H0312 4X6 H0312 5X8 4X6 2X4 4X8 5X8 3X6 H0312 4X8 4X8(R) 3X6 6X10 4X6 3X6(B1T) 40'7' 4'6-9/16" 4'6-9/16" 9'9-3/8" 5'2-13/16" 15'0-3/16" 5'2-13/16" 20'3" 5'2-13/16" 24'6" 4'3" 28'9" 4'3" 34'8-1/8" 5'11-1/8" 39'9-1/4" 5'1-1/8" 47' 7'2-3/4" 4'6-9/16" 4'6-9/16" 12'4-3/4" 7'10-1/4" 20'3" 7'10-1/4" 24'6" 4'3" 28'9" 4'3" 37'7-11/16" 8'10-11/16" 39'9-1/4" 2'1-9/16" 47' 7'2-3/4"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T6 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. :B3 2x4 DF-L 2400f-2.0E: Webs 2x4 DF-L Stud :W5, W6, W7, W8 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2368 /- /- /814 /152 /259 P 3748 /- /- /1398 /173 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.5 P Brg Width = 5.5 Min Req = 2.8 Bearings B & P Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 68 0 B - C 700 -5539 C - D 865 -6123 D - E 500 -3162 E - F 510 -2953 F - G 404 -1830 G - H 353 -1167 Chords Tens. Comp. H - I 353 -1167 I - J 309 -1090 J - K 1382 - 337 K - L 1323 - 344 L - M 1425 - 400 M - N 841 -350 N - O 49 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - W 5182 -616 W - V 3163 -338 V - U 2209 -189 U - T 2209 -189 T - S 1429 -165 Chords Tens. Comp. S - R 815 -200 R - Q 407 -396 Q - P 407 -396 P - N 358 -606 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - W 339 -1751 W - D 2688 -465 D - V 222 -1125 V - F 1196 -168 F - T 244 -1362 G - T 1207 -168 G - S 122 -892 Webs Tens. Comp. H - S 82 -622 S - I 1066 - 207 I - R 258 -1087 R - J 1527 - 226 J - P 487 -2964 P - L 75 -385 P - M 179 -616 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.327 C 999 240 VERT(CL): 0.453 C 970 180 HORZ(LL): 0.088 C - - HORZ(TL): 0.121 C - - Creep Factor: 2.0 Max TC CSI: 0.896 Max BC CSI: 0.852 Max Web CSI: 0.922 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:C3 Ply: 1 Qty: 3 Wgt: 0.0 lbs SEQN: 259918 / T12 / COMN FROM:DRW: ... / ... 02/04/2020 T6 B3 W5 W6 W7 W6 W7 W6 W8 (a) (a)(a)(a)(a) A B C D E F GH I J K L M N O PQRSTUVW 4 12 7 12 3X12(B1T) 7X14(R) 5X8 6X10(R) 4X6(R) H0312 4X6 H0312 5X8 4X6 2X4 5X8 6X10 4X6 H0312 6X10 H0312 7X14 2X4 2X4 3X6(B1T) 37'10' 4'6-9/16" 4'6-9/16" 9'9-3/8" 5'2-13/16" 15'0-3/16" 5'2-13/16" 20'3" 5'2-13/16" 24'6" 4'3" 28'9" 4'3" 34'8-1/8" 5'11-1/8" 36'9-1/4" 2'1-1/8" 41'6-15/16" 4'9-11/16" 47' 5'5-1/16" 4'6-9/16" 4'6-9/16" 12'4-3/4" 7'10-1/4" 20'3" 7'10-1/4" 24'6" 4'3" 28'9" 4'3" 36'9-1/4" 8'0-1/4" 47' 10'2-3/4"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T6 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. :B3 2x4 DF-L 2400f-2.0E: Webs 2x4 DF-L Stud :W5, W6, W7, W8 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2368 /- /- /814 /152 /259 P 3748 /- /- /1398 /173 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.5 P Brg Width = 5.5 Min Req = 2.8 Bearings B & P Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 68 0 B - C 700 -5539 C - D 865 -6123 D - E 500 -3162 E - F 510 -2953 F - G 404 -1830 G - H 353 -1167 Chords Tens. Comp. H - I 353 -1167 I - J 309 -1090 J - K 1382 - 337 K - L 1323 - 344 L - M 1425 - 400 M - N 841 -350 N - O 49 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - W 5182 -616 W - V 3163 -338 V - U 2209 -189 U - T 2209 -189 T - S 1429 -165 Chords Tens. Comp. S - R 815 -200 R - Q 407 -396 Q - P 407 -396 P - N 358 -606 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - W 339 -1751 W - D 2688 -465 D - V 222 -1125 V - F 1196 -168 F - T 244 -1362 G - T 1207 -168 G - S 122 -892 Webs Tens. Comp. H - S 82 -622 S - I 1066 - 207 I - R 258 -1087 R - J 1527 - 226 J - P 487 -2964 P - L 75 -385 P - M 179 -616 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.327 C 999 240 VERT(CL): 0.453 C 970 180 HORZ(LL): 0.088 C - - HORZ(TL): 0.121 C - - Creep Factor: 2.0 Max TC CSI: 0.896 Max BC CSI: 0.852 Max Web CSI: 0.922 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:C3 Ply: 1 Qty: 3 Wgt: 0.0 lbs SEQN: 259918 / T12 / COMN FROM:DRW: ... / ... 02/04/2020 T6 B3 W5 W6 W7 W6 W7 W6 W8 (a) (a)(a)(a)(a) A B C D E F GH I J K L M N O PQRSTUVW 4 12 7 12 3X12(B1T) 7X14(R) 5X8 6X10(R) 4X6(R) H0312 4X6 H0312 5X8 4X6 2X4 5X8 6X10 4X6 H0312 6X10 H0312 7X14 2X4 2X4 3X6(B1T) 37'10' 4'6-9/16" 4'6-9/16" 9'9-3/8" 5'2-13/16" 15'0-3/16" 5'2-13/16" 20'3" 5'2-13/16" 24'6" 4'3" 28'9" 4'3" 34'8-1/8" 5'11-1/8" 36'9-1/4" 2'1-1/8" 41'6-15/16" 4'9-11/16" 47' 5'5-1/16" 4'6-9/16" 4'6-9/16" 12'4-3/4" 7'10-1/4" 20'3" 7'10-1/4" 24'6" 4'3" 28'9" 4'3" 36'9-1/4" 8'0-1/4" 47' 10'2-3/4"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T2 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. :B1 2x4 DF-L 2400f-2.0E: Webs 2x4 DF-L Stud :W2, W5, W6, W7, W8 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. (**) 2 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2248 /- /- /827 /167 /291 AL* 480 /- /- /171 /29 /- AF /-334 Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.2 AL Brg Width = 101 Min Req = - Bearings B & AL Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 68 0 B - C 778 -5137 C - D 805 -5102 D - E 941 -5642 E - F 985 -5599 F - G 501 -3111 G - H 506 -2999 H - I 540 -2998 I - J 549 -2957 J - K 547 -2831 K - L 368 -1866 L - M 393 -1810 M - N 423 -1744 N - O 346 -1184 Chords Tens. Comp. O - P 346 -1183 P - Q 346 -1183 Q - R 346 -1184 R - S 298 -796 S - T 264 -827 T - U 199 -697 U - V 1335 - 284 V - W 1470 - 332 W - X 1353 - 340 X - Y 1326 - 350 Y - Z 935 -300 Z -AA 859 -312 AA-AB 806 -333 AB-AC 55 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -BB 4818 -703 BB-BA 4812 -699 BA-AZ 3060 -335 AZ-AY 3060 -335 AY-AX 3059 -335 AX-AW 3059 -335 AW-AV 2209 -185 AV-AU 2209 -185 AU-AT 2209 -185 AT-AS 2209 -185 AS-AR 2209 -185 AR-AQ 1502 -159 AQ-AP 1502 -159 Chords Tens. Comp. AP-AO 622 -178 AO-AN 622 -178 AN-AM 398 -628 AM-AL 398 -628 AL-AK 398 -628 AK-AJ 398 -628 AJ-AI 399 -644 AI-AH 399 -644 AH-AG 364 -699 AG-AF 729 -1399 AF-AE 362 -685 AE-AD 362 -683 AD-AB 361 -676 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp.Webs Tens. Comp. Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.327 AZ 999 240 VERT(CL): 0.453 AZ 843 180 HORZ(LL): 0.090 E - - HORZ(TL): 0.123 E - - Creep Factor: 2.0 Max TC CSI: 0.648 Max BC CSI: 0.623 Max Web CSI: 0.902 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:C4 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259899 / T1 / GABL FROM: Page 1 of 2 DRW: ... / ... 02/04/2020 T2 B1 W2 W5 W6 W7 W6 W7 W6 W8 (a) (a)(a)(a) (a) A B C D E F G H I J K L M NOPQR S T U V W X Y Z AA AB AC ADAEAFAGAHAIAJAKALAMANAOAPAQARASATAUAVAWAXAYAZBABB BC BD BE BF BG BH BI BJBK BLBM BN BO BP BQ BRBS BTBU BV BWBX BY BZ CA 4 12 7 12 3X12(B1T) 7X14(R) 4X12 4X8 8X14(R) H0312 4X6 H0312 2X4(**) 5X8 4X6 6X10 5X8 4X8(R)H0312 2X4(**) 4X6 3X6 3X6 3X6(B1T) 40'7' 2'6"4'2'(TYP) 4'4'4' 4'6-9/16" 4'6-9/16" 9'9-3/8" 5'2-13/16" 15'0-3/16" 5'2-13/16" 20'3" 5'2-13/16" 24'6" 4'3" 28'9" 4'3" 34'8-1/8" 5'11-1/8" 40'6" 5'9-7/8" 40'7-5/16" 1-5/16" 47' 6'4-11/16" 4'6-9/16" 4'6-9/16" 12'4-3/4" 7'10-1/4" 20'3" 7'10-1/4" 24'6" 4'3" 28'9" 4'3" 37'7-11/16" 8'10-11/16" 47' 9'4-5/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T2 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. :B1 2x4 DF-L 2400f-2.0E: Webs 2x4 DF-L Stud :W2, W5, W6, W7, W8 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. (**) 2 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2248 /- /- /827 /167 /291 AL* 480 /- /- /171 /29 /- AF /-334 Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.2 AL Brg Width = 101 Min Req = - Bearings B & AL Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 68 0 B - C 778 -5137 C - D 805 -5102 D - E 941 -5642 E - F 985 -5599 F - G 501 -3111 G - H 506 -2999 H - I 540 -2998 I - J 549 -2957 J - K 547 -2831 K - L 368 -1866 L - M 393 -1810 M - N 423 -1744 N - O 346 -1184 Chords Tens. Comp. O - P 346 -1183 P - Q 346 -1183 Q - R 346 -1184 R - S 298 -796 S - T 264 -827 T - U 199 -697 U - V 1335 - 284 V - W 1470 - 332 W - X 1353 - 340 X - Y 1326 - 350 Y - Z 935 -300 Z -AA 859 -312 AA-AB 806 -333 AB-AC 55 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -BB 4818 -703 BB-BA 4812 -699 BA-AZ 3060 -335 AZ-AY 3060 -335 AY-AX 3059 -335 AX-AW 3059 -335 AW-AV 2209 -185 AV-AU 2209 -185 AU-AT 2209 -185 AT-AS 2209 -185 AS-AR 2209 -185 AR-AQ 1502 -159 AQ-AP 1502 -159 Chords Tens. Comp. AP-AO 622 -178 AO-AN 622 -178 AN-AM 398 -628 AM-AL 398 -628 AL-AK 398 -628 AK-AJ 398 -628 AJ-AI 399 -644 AI-AH 399 -644 AH-AG 364 -699 AG-AF 729 -1399 AF-AE 362 -685 AE-AD 362 -683 AD-AB 361 -676 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp.Webs Tens. Comp. Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 4.70 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.327 AZ 999 240 VERT(CL): 0.453 AZ 843 180 HORZ(LL): 0.090 E - - HORZ(TL): 0.123 E - - Creep Factor: 2.0 Max TC CSI: 0.648 Max BC CSI: 0.623 Max Web CSI: 0.902 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:C4 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259899 / T1 / GABL FROM: Page 1 of 2 DRW: ... / ... 02/04/2020 T2 B1 W2 W5 W6 W7 W6 W7 W6 W8 (a) (a)(a)(a) (a) A B C D E F G H I J K L M NOPQR S T U V W X Y Z AA AB AC ADAEAFAGAHAIAJAKALAMANAOAPAQARASATAUAVAWAXAYAZBABB BC BD BE BF BG BH BI BJBK BLBM BN BO BP BQ BRBS BTBU BV BWBX BY BZ CA 4 12 7 12 3X12(B1T) 7X14(R) 4X12 4X8 8X14(R) H0312 4X6 H0312 2X4(**) 5X8 4X6 6X10 5X8 4X8(R)H0312 2X4(**) 4X6 3X6 3X6 3X6(B1T) 40'7' 2'6"4'2'(TYP) 4'4'4' 4'6-9/16" 4'6-9/16" 9'9-3/8" 5'2-13/16" 15'0-3/16" 5'2-13/16" 20'3" 5'2-13/16" 24'6" 4'3" 28'9" 4'3" 34'8-1/8" 5'11-1/8" 40'6" 5'9-7/8" 40'7-5/16" 1-5/16" 47' 6'4-11/16" 4'6-9/16" 4'6-9/16" 12'4-3/4" 7'10-1/4" 20'3" 7'10-1/4" 24'6" 4'3" 28'9" 4'3" 37'7-11/16" 8'10-11/16" 47' 9'4-5/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 0 - 1 / 1 6 " 11 ' 6 - 1 3 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org D -BA 312 -1502 BA-BC 2483 -534 BD-BE 2541 -543 BE- F 2541 -538 F -BF 225 -1119 BG-AW 228 -1136 AW-BH 1162 -232 BI- K 1213 -239 K -BJ 261 -1313 BK-BL 268 -1343 BM-AR 272 -1369 N -AR 1285 -245 N -BN 152 -988 BO-AP 154 -989 P -AP 71 -443 AP-BP 1518 -247 BQ- R 1547 -251 R -AN 181 -1324 AN-BR 1863 -250 BS-BT 1863 -253 BU-BV 1998 -270 BV- U 1230 -170 U -BW 271 -1617 BX-AH 264 -1534 AH-BY 203 -768 BZ-CA 227 -851 CA- Y 170 -523 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -BB 84 -109 BC-AZ 64 -64 E -BD 71 -167 BE-AY 32 -10 BF- G 178 -17 AX-BG 201 -19 AW- H 59 -248 BH-AV 176 -19 J -BI 125 -11 BJ- L 42 -77 AT-BK 48 -39 BL- M 47 -127 AS-BM 42 -103 BN- O 42 -150 AQ-BO 43 -123 Gables Tens. Comp. BP-AO 46 -154 Q -BQ 48 -186 BR-AM 49 -198 S -BS 53 -212 BT-AK 88 -426 T -BU 107 -560 BV-AJ 132 -1017 BW- V 98 -516 AI-BX 110 -594 BY-AG 48 -175 W -BZ 87 -77 CA-AF 436 -95 AE- Z 43 -60 AD-AA 55 -121 Job Number:PB201526 FAIRES Truss Label:C4 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259899 / T1 / GABL FROM: Page 2 of 2 DRW: ... / ... 02/04/2020 PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL A 40 /- /- /35 /29 /52 B* 119 /- /- /43 /41 /- G 40 /- /- /16 /29 /- Wind reactions based on MWFRS A Brg Width = 6.9 Min Req = 1.5 B Brg Width = 81.7 Min Req = - G Brg Width = 6.9 Min Req = 1.5 Bearings A, B, & G are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 64 -63 B - C 31 -53 C - D 65 -98 Chords Tens. Comp. D - E 65 -98 E - F 10 -53 F - G 19 -20 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 42 -13 J - I 50 -11 Chords Tens. Comp. I - H 50 -11 H - F 42 -8 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 99 -252 D - I 3 -160 Webs Tens. Comp. H - E 99 -252 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 2.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 D 999 240 VERT(CL): 0.001 D 999 180 HORZ(LL): 0.000 E - - HORZ(TL): 0.000 E - - Creep Factor: 2.0 Max TC CSI: 0.070 Max BC CSI: 0.010 Max Web CSI: 0.047 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:CAP1 Ply: 1 Qty: 2 Wgt: 0.0 lbs SEQN: 259989 / T13 / DGAB FROM:DRW: ... / ... 02/04/2020 A B C D E F G HIJ 7 12 2X4(A1T) 4X6 2X4(A1T) 10-3/16"6'9-11/16"10-3/16" 10-3/16" 10-3/16" 2'3" 1'4-13/16"4'3" 2' 6'3" 2' 7'7-13/16" 1'4-13/16" 8'6" 10-3/16" 10-3/16" 10-3/16" 2'3" 1'4-13/16"4'3" 2' 6'3" 2' 7'7-13/16" 1'4-13/16" 8'6" 10-3/16" 10-3/16" 6-15/16" 2' 4 - 1 / 8 " 1-5/8" 2' 5 - 3 / 4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL A 40 /- /- /35 /29 /52 B* 119 /- /- /43 /41 /- G 40 /- /- /16 /29 /- Wind reactions based on MWFRS A Brg Width = 6.9 Min Req = 1.5 B Brg Width = 81.7 Min Req = - G Brg Width = 6.9 Min Req = 1.5 Bearings A, B, & G are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 64 -63 B - C 31 -53 C - D 65 -98 Chords Tens. Comp. D - E 65 -98 E - F 10 -53 F - G 19 -20 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 42 -13 J - I 50 -11 Chords Tens. Comp. I - H 50 -11 H - F 42 -8 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 99 -252 D - I 3 -160 Webs Tens. Comp. H - E 99 -252 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 2.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 D 999 240 VERT(CL): 0.001 D 999 180 HORZ(LL): 0.000 E - - HORZ(TL): 0.000 E - - Creep Factor: 2.0 Max TC CSI: 0.070 Max BC CSI: 0.010 Max Web CSI: 0.047 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:CAP1 Ply: 1 Qty: 2 Wgt: 0.0 lbs SEQN: 259989 / T13 / DGAB FROM:DRW: ... / ... 02/04/2020 A B C D E F G HIJ 7 12 2X4(A1T) 4X6 2X4(A1T) 10-3/16"6'9-11/16"10-3/16" 10-3/16" 10-3/16" 2'3" 1'4-13/16"4'3" 2' 6'3" 2' 7'7-13/16" 1'4-13/16" 8'6" 10-3/16" 10-3/16" 10-3/16" 2'3" 1'4-13/16"4'3" 2' 6'3" 2' 7'7-13/16" 1'4-13/16" 8'6" 10-3/16" 10-3/16" 6-15/16" 2' 4 - 1 / 8 " 1-5/8" 2' 5 - 3 / 4 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4(A1T) except as noted. Loading Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL A - /-86 /- /32 /41 /46 B* 123 /- /- /46 /18 /- E - /-86 /- /13 /18 /- Wind reactions based on MWFRS A Brg Width = 6.9 Min Req = 1.5 B Brg Width = 81.7 Min Req = - E Brg Width = 6.9 Min Req = 1.5 Bearings A, B, & E are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 80 -56 B - C 61 -198 Chords Tens. Comp. C - D 61 -198 D - E 80 -12 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 75 -6 Chords Tens. Comp. F - D 75 -6 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 10 -142 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 2.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.002 F 999 240 VERT(CL): 0.003 F 999 180 HORZ(LL): 0.002 F - - HORZ(TL): 0.002 F - - Creep Factor: 2.0 Max TC CSI: 0.165 Max BC CSI: 0.064 Max Web CSI: 0.028 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:CAP2 Ply: 1 Qty: 16 Wgt: 0.0 lbs SEQN: 259992 / T6 / COMN FROM:DRW: ... / ... 02/04/2020 A B C D E F 7 12 4X6 2X4 10-3/16"6'9-11/16"10-3/16" 10-3/16" 10-3/16" 4'3" 3'4-13/16" 7'7-13/16" 3'4-13/16" 8'6" 10-3/16" 10-3/16" 10-3/16" 4'3" 3'4-13/16" 7'7-13/16" 3'4-13/16" 8'6" 10-3/16" 10-3/16"6-15/16" 2' 4 - 1 / 8 " 1-5/8" 2' 5 - 3 / 4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Plating Notes All plates are 2X4(A1T) except as noted. Loading Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL A - /-86 /- /32 /41 /46 B* 123 /- /- /46 /18 /- E - /-86 /- /13 /18 /- Wind reactions based on MWFRS A Brg Width = 6.9 Min Req = 1.5 B Brg Width = 81.7 Min Req = - E Brg Width = 6.9 Min Req = 1.5 Bearings A, B, & E are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 80 -56 B - C 61 -198 Chords Tens. Comp. C - D 61 -198 D - E 80 -12 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 75 -6 Chords Tens. Comp. F - D 75 -6 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 10 -142 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 2.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.002 F 999 240 VERT(CL): 0.003 F 999 180 HORZ(LL): 0.002 F - - HORZ(TL): 0.002 F - - Creep Factor: 2.0 Max TC CSI: 0.165 Max BC CSI: 0.064 Max Web CSI: 0.028 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:CAP2 Ply: 1 Qty: 16 Wgt: 0.0 lbs SEQN: 259992 / T6 / COMN FROM:DRW: ... / ... 02/04/2020 A B C D E F 7 12 4X6 2X4 10-3/16"6'9-11/16"10-3/16" 10-3/16" 10-3/16" 4'3" 3'4-13/16" 7'7-13/16" 3'4-13/16" 8'6" 10-3/16" 10-3/16" 10-3/16" 4'3" 3'4-13/16" 7'7-13/16" 3'4-13/16" 8'6" 10-3/16" 10-3/16"6-15/16" 2' 4 - 1 / 8 " 1-5/8" 2' 5 - 3 / 4 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W5, W6 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1935 /- /- /689 /136 /202 H 1769 /- /- /656 /123 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.1 H Brg Width = 5.5 Min Req = 1.9 Bearings B & H Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 64 0 B - C 719 -4380 C - D 444 -2845 D - E 356 -1906 Chords Tens. Comp. E - F 352 -1844 F - G 323 -1937 G - H 382 -2710 H - I 48 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - N 4094 -636 N - M 4092 -639 M - L 2329 -236 Chords Tens. Comp. L - K 2329 - 236 K - J 2208 - 217 J - H 2210 - 217 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. N - C 149 -14 C - M 412 -1835 M - D 576 -78 D - K 238 -1188 Webs Tens. Comp. E - K 1219 - 223 K - G 192 -917 G - J 281 0 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.20 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.218 M 999 240 VERT(CL): 0.313 M 999 180 HORZ(LL): 0.076 J - - HORZ(TL): 0.113 J - - Creep Factor: 2.0 Max TC CSI: 0.775 Max BC CSI: 0.717 Max Web CSI: 0.484 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:D1 Ply: 1 Qty: 6 Wgt: 0.0 lbs SEQN: 259955 / T4 / COMN FROM:DRW: ... / ... 02/04/2020 W5 W6 (a) (a)(a) A B C D E F G H I JKLMN 4 12 7 12 3X12(B1T) 2X4 5X6 3X12 3X6 3X6 5X6 3X12 3X6 3X6 2X4 3X12(B3T) 32' 4'6-9/16" 4'6-9/16" 10'9-1/4" 6'2-3/4" 17' 6'2-3/4" 24'3-3/16" 7'3-3/16" 32' 7'8-13/16" 4'6-9/16" 4'6-9/16" 10'9-1/4" 6'2-3/4" 17' 6'2-3/4" 24'3-3/16" 7'3-3/16" 32' 7'8-13/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 9' 1 - 5 / 1 6 " 9' 8 - 1 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W5, W6 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1935 /- /- /689 /136 /202 H 1769 /- /- /656 /123 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.1 H Brg Width = 5.5 Min Req = 1.9 Bearings B & H Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 64 0 B - C 719 -4380 C - D 444 -2845 D - E 356 -1906 Chords Tens. Comp. E - F 352 -1844 F - G 323 -1937 G - H 382 -2710 H - I 48 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - N 4094 -636 N - M 4092 -639 M - L 2329 -236 Chords Tens. Comp. L - K 2329 - 236 K - J 2208 - 217 J - H 2210 - 217 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. N - C 149 -14 C - M 412 -1835 M - D 576 -78 D - K 238 -1188 Webs Tens. Comp. E - K 1219 - 223 K - G 192 -917 G - J 281 0 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.20 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.218 M 999 240 VERT(CL): 0.313 M 999 180 HORZ(LL): 0.076 J - - HORZ(TL): 0.113 J - - Creep Factor: 2.0 Max TC CSI: 0.775 Max BC CSI: 0.717 Max Web CSI: 0.484 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:D1 Ply: 1 Qty: 6 Wgt: 0.0 lbs SEQN: 259955 / T4 / COMN FROM:DRW: ... / ... 02/04/2020 W5 W6 (a) (a)(a) A B C D E F G H I JKLMN 4 12 7 12 3X12(B1T) 2X4 5X6 3X12 3X6 3X6 5X6 3X12 3X6 3X6 2X4 3X12(B3T) 32' 4'6-9/16" 4'6-9/16" 10'9-1/4" 6'2-3/4" 17' 6'2-3/4" 24'3-3/16" 7'3-3/16" 32' 7'8-13/16" 4'6-9/16" 4'6-9/16" 10'9-1/4" 6'2-3/4" 17' 6'2-3/4" 24'3-3/16" 7'3-3/16" 32' 7'8-13/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 9' 1 - 5 / 1 6 " 9' 8 - 1 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :M7, M8, M9 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL W* 131 /- /- /40 /9 /7 Wind reactions based on MWFRS W Brg Width = 467 Min Req = - Bearing B Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 65 0 B - C 116 -170 C - D 119 -161 D - E 128 -159 E - F 121 -138 F - G 113 -116 G - H 99 -93 H - I 105 -78 I - J 127 -73 J - K 171 -71 K - L 216 -78 L - M 261 -93 Chords Tens. Comp. M - N 261 -98 N - O 216 -83 O - P 171 -78 P - Q 127 -73 Q - R 83 -46 R - S 78 -74 S - T 80 -83 T - U 89 -106 U - V 97 -128 V - W 101 -152 W - X 54 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -AR 193 -132 AR-AQ 195 -133 AQ-AP 198 -134 AP-AO 199 -136 AO-AN 200 -136 AN-AM 200 -137 AM-AL 201 -138 AL-AK 158 -114 AK-AJ 158 -114 AJ-AI 158 -114 AI-AH 159 -114 Chords Tens. Comp. AH-AG 159 -114 AG-AF 158 -114 AF-AE 158 -113 AE-AD 158 -113 AD-AC 158 -113 AC-AB 157 -112 AB-AA 156 -112 AA- Z 155 -111 Z - Y 154 -109 Y - W 152 -108 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D -AQ 71 -204 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AR 124 -268 E -AP 60 -212 Gables Tens. Comp. AG- N 65 -302 AF- O 66 -268 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.90 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.002 L 999 240 VERT(CL): 0.004 N 999 180 HORZ(LL): 0.003 O - - HORZ(TL): 0.005 O - - Creep Factor: 2.0 Max TC CSI: 0.314 Max BC CSI: 0.060 Max Web CSI: 0.172 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:E1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259951 / T3 / GABL FROM: Page 1 of 2 DRW: ... / ... 02/04/2020 M7 M8 M9 M8 M7 (a) (a) (a) (a) (a) A B C D E F G H I J K L M N O P Q R S T U V W X YZAAABACADAEAFAGAHAIAJAKALAMANAOAPAQAR 4 12 7 12 3X6(A1T) 5X6 3X6 3X6 5X6 3X6 3X6 3X6(B1T) 39' 2'6"4'2'(TYP) 4'6-9/16" 4'6-9/16" 20'6" 15'11-7/16" 39' 18'6" 4'6-9/16" 4'6-9/16" 39' 34'5-7/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :M7, M8, M9 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL W* 131 /- /- /40 /9 /7 Wind reactions based on MWFRS W Brg Width = 467 Min Req = - Bearing B Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 65 0 B - C 116 -170 C - D 119 -161 D - E 128 -159 E - F 121 -138 F - G 113 -116 G - H 99 -93 H - I 105 -78 I - J 127 -73 J - K 171 -71 K - L 216 -78 L - M 261 -93 Chords Tens. Comp. M - N 261 -98 N - O 216 -83 O - P 171 -78 P - Q 127 -73 Q - R 83 -46 R - S 78 -74 S - T 80 -83 T - U 89 -106 U - V 97 -128 V - W 101 -152 W - X 54 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -AR 193 -132 AR-AQ 195 -133 AQ-AP 198 -134 AP-AO 199 -136 AO-AN 200 -136 AN-AM 200 -137 AM-AL 201 -138 AL-AK 158 -114 AK-AJ 158 -114 AJ-AI 158 -114 AI-AH 159 -114 Chords Tens. Comp. AH-AG 159 -114 AG-AF 158 -114 AF-AE 158 -113 AE-AD 158 -113 AD-AC 158 -113 AC-AB 157 -112 AB-AA 156 -112 AA- Z 155 -111 Z - Y 154 -109 Y - W 152 -108 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D -AQ 71 -204 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AR 124 -268 E -AP 60 -212 Gables Tens. Comp. AG- N 65 -302 AF- O 66 -268 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.90 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.002 L 999 240 VERT(CL): 0.004 N 999 180 HORZ(LL): 0.003 O - - HORZ(TL): 0.005 O - - Creep Factor: 2.0 Max TC CSI: 0.314 Max BC CSI: 0.060 Max Web CSI: 0.172 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:E1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259951 / T3 / GABL FROM: Page 1 of 2 DRW: ... / ... 02/04/2020 M7 M8 M9 M8 M7 (a) (a) (a) (a) (a) A B C D E F G H I J K L M N O P Q R S T U V W X YZAAABACADAEAFAGAHAIAJAKALAMANAOAPAQAR 4 12 7 12 3X6(A1T) 5X6 3X6 3X6 5X6 3X6 3X6 3X6(B1T) 39' 2'6"4'2'(TYP) 4'6-9/16" 4'6-9/16" 20'6" 15'11-7/16" 39' 18'6" 4'6-9/16" 4'6-9/16" 39' 34'5-7/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org F -AO 63 -222 G -AN 63 -229 I -AM 63 -237 J -AK 62 -242 K -AJ 66 -256 L -AI 65 -296 M -AH 0 -230 AE- P 62 -242 AC- Q 63 -237 AB- S 63 -229 AA- T 63 -221 Z - U 64 -214 Y - V 65 -200 Job Number:PB201526 FAIRES Truss Label:E1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259951 / T3 / GABL FROM: Page 2 of 2 DRW: ... / ... 02/04/2020 PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W5, W6, W7 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2277 /- /- /895 /192 /285 K 2134 /- /- /851 /176 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.4 K Brg Width = 3.5 Min Req = 2.3 Bearings B & K Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 65 0 B - C 995 -5382 C - D 1199 -5929 D - E 632 -3318 E - F 652 -3222 F - G 503 -2235 Chords Tens. Comp. G - H 500 -2258 H - I 573 -3020 I - J 546 -3100 J - K 560 -3441 K - L 48 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - R 5047 -889 R - Q 3231 -445 Q - P 2437 -241 P - O 2437 -241 Chords Tens. Comp. O - N 2357 - 232 N - M 2357 - 232 M - K 2860 - 374 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - R 426 -1617 R - D 2510 -589 D - Q 268 -927 Q - F 1006 -211 F - O 283 -1184 Webs Tens. Comp. G - O 1627 - 372 O - H 232 -951 H - M 553 -97 M - J 168 -470 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.90 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.328 Q 999 240 VERT(CL): 0.486 Q 955 180 HORZ(LL): 0.097 M - - HORZ(TL): 0.144 M - - Creep Factor: 2.0 Max TC CSI: 0.895 Max BC CSI: 0.838 Max Web CSI: 0.840 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:E2 Ply: 1 Qty: 14 Wgt: 0.0 lbs SEQN: 259936 / T7 / COMN FROM:DRW: ... / ... 02/04/2020 W5 W6 W7 (a)(a) A B C D E F G H I J K L MNOPQR 4 12 7 12 3X12(B1T) 7X14(R) 4X12 5X8(R) 3X6 4X6 3X6 3X6 5X6 4X8 3X6 3X6 3X6 3X6 2X4 4X8(B3T) 39' 4'6-9/16" 4'6-9/16" 9'10-3/8" 5'3-13/16" 15'2-3/16" 5'3-13/16" 20'6" 5'3-13/16" 26'6-1/8" 6'0-1/8" 32'6-5/16" 6'0-1/8" 39' 6'5-11/16" 4'6-9/16" 4'6-9/16" 12'6-1/4" 7'11-3/4" 20'6" 7'11-3/4" 29'6-3/16" 9'0-3/16" 39' 9'5-13/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W5, W6, W7 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2277 /- /- /895 /192 /285 K 2134 /- /- /851 /176 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.4 K Brg Width = 3.5 Min Req = 2.3 Bearings B & K Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 65 0 B - C 995 -5382 C - D 1199 -5929 D - E 632 -3318 E - F 652 -3222 F - G 503 -2235 Chords Tens. Comp. G - H 500 -2258 H - I 573 -3020 I - J 546 -3100 J - K 560 -3441 K - L 48 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - R 5047 -889 R - Q 3231 -445 Q - P 2437 -241 P - O 2437 -241 Chords Tens. Comp. O - N 2357 - 232 N - M 2357 - 232 M - K 2860 - 374 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - R 426 -1617 R - D 2510 -589 D - Q 268 -927 Q - F 1006 -211 F - O 283 -1184 Webs Tens. Comp. G - O 1627 - 372 O - H 232 -951 H - M 553 -97 M - J 168 -470 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.90 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.328 Q 999 240 VERT(CL): 0.486 Q 955 180 HORZ(LL): 0.097 M - - HORZ(TL): 0.144 M - - Creep Factor: 2.0 Max TC CSI: 0.895 Max BC CSI: 0.838 Max Web CSI: 0.840 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:E2 Ply: 1 Qty: 14 Wgt: 0.0 lbs SEQN: 259936 / T7 / COMN FROM:DRW: ... / ... 02/04/2020 W5 W6 W7 (a)(a) A B C D E F G H I J K L MNOPQR 4 12 7 12 3X12(B1T) 7X14(R) 4X12 5X8(R) 3X6 4X6 3X6 3X6 5X6 4X8 3X6 3X6 3X6 3X6 2X4 4X8(B3T) 39' 4'6-9/16" 4'6-9/16" 9'10-3/8" 5'3-13/16" 15'2-3/16" 5'3-13/16" 20'6" 5'3-13/16" 26'6-1/8" 6'0-1/8" 32'6-5/16" 6'0-1/8" 39' 6'5-11/16" 4'6-9/16" 4'6-9/16" 12'6-1/4" 7'11-3/4" 20'6" 7'11-3/4" 29'6-3/16" 9'0-3/16" 39' 9'5-13/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T2 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. :B1 2x4 DF-L 2400f-2.0E: Webs 2x4 DF-L Stud :W2, W5, W6, W7 2x4 DF-L #1&Bet.: :Rt Wedge 2x4 DF-L Stud: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. (**) 4 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2577 /- /- /895 /192 /285 X 2538 /- /- /851 /176 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.6 X Brg Width = 3.5 Min Req = 2.7 Bearings B & X Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 65 0 B - C 983 -6235 C - D 1009 -6200 D - E 1163 -6816 E - F 1209 -6789 F - G 624 -4061 G - H 625 -3938 H - I 628 -3850 I - J 670 -3936 J - K 673 -3783 K - L 465 -2738 L - M 489 -2688 Chords Tens. Comp. M - N 519 -2614 N - O 518 -2610 O - P 489 -2689 P - Q 455 -2736 Q - R 611 -3641 R - S 577 -3683 S - T 541 -3607 T - U 540 -3710 U - V 566 -3988 V - W 536 -4047 W - X 508 -4108 X - Y 54 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -AT 5850 -896 AT-AS 5846 -892 AS-AR 3917 -440 AR-AQ 3917 -440 AQ-AP 3916 -440 AP-AO 3916 -440 AO-AN 2982 -236 AN-AM 2982 -236 AM-AL 2982 -236 AL-AK 2982 -236 AK-AJ 2982 -236 Chords Tens. Comp. AJ-AI 2896 -226 AI-AH 2896 -226 AH-AG 2896 -226 AG-AF 2894 -225 AF-AE 2894 -225 AE-AD 2894 -225 AD-AC 3443 -365 AC-AB 3443 -365 AB-AA 3438 -364 AA- Z 3441 -365 Z - X 3446 - 367 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D -AS 355 -1650 AS-AU 2508 -591 AV-AW 2586 -603 AW- F 2571 -597 F -AX 242 -1108 Webs Tens. Comp. BE-AJ 272 -1267 N -AJ 2077 - 431 AJ-BF 222 -1009 BG-BH 220 -1003 BI- Q 212 -963 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.90 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.380 AR 999 240 VERT(CL): 0.590 AR 787 180 HORZ(LL): 0.107 Z - - HORZ(TL): 0.166 Z - - Creep Factor: 2.0 Max TC CSI: 0.752 Max BC CSI: 0.831 Max Web CSI: 0.692 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:E3 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259947 / T14 / GABL FROM: Page 1 of 2 DRW: ... / ... 02/04/2020 T2 B1 W2 W5 W6 W7 (a)(a) A B C D E F G H I J K L M N O P Q R ST U V W X Y ZAAABACADAEAFAGAHAIAJAKALAMANAOAPAQARASAT AU AV AW AXAY AZ BA BBBC BDBE BFBG BH BI BJ BK BL BM 4 12 7 12 4X12(B7RT) 8X8(R) 4X12 4X8 3X6 7X14(R)H0312 2X4(**) 4X6 5X6 5X8 7X14(R) H0312 2X4(**) 3X6 3X6(**) 4X6(**) 5X8(B7RT) 39' 2'6"4'2'(TYP) 4' 4'6-9/16" 4'6-9/16" 9'10-3/8" 5'3-13/16" 15'2-3/16" 5'3-13/16" 20'6" 5'3-13/16" 26'6-1/8" 6'0-1/8" 32'6" 5'11-7/8" 32'6-5/16" 0-5/16" 39' 6'5-11/16" 4'6-9/16" 4'6-9/16" 12'6-1/4" 7'11-3/4" 20'6" 7'11-3/4" 29'6-3/16" 9'0-3/16" 39' 9'5-13/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. :T2 2x4 DF-L 2400f-2.0E: Bot chord 2x4 DF-L #1&Bet. :B1 2x4 DF-L 2400f-2.0E: Webs 2x4 DF-L Stud :W2, W5, W6, W7 2x4 DF-L #1&Bet.: :Rt Wedge 2x4 DF-L Stud: Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. (**) 4 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWGS A11515ENC101014, GBLLETIN0118, & GABRST101014 for gable wind bracing and other requirements. Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2577 /- /- /895 /192 /285 X 2538 /- /- /851 /176 /- Wind reactions based on MWFRS B Brg Width = 5.5 Min Req = 2.6 X Brg Width = 3.5 Min Req = 2.7 Bearings B & X Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 65 0 B - C 983 -6235 C - D 1009 -6200 D - E 1163 -6816 E - F 1209 -6789 F - G 624 -4061 G - H 625 -3938 H - I 628 -3850 I - J 670 -3936 J - K 673 -3783 K - L 465 -2738 L - M 489 -2688 Chords Tens. Comp. M - N 519 -2614 N - O 518 -2610 O - P 489 -2689 P - Q 455 -2736 Q - R 611 -3641 R - S 577 -3683 S - T 541 -3607 T - U 540 -3710 U - V 566 -3988 V - W 536 -4047 W - X 508 -4108 X - Y 54 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B -AT 5850 -896 AT-AS 5846 -892 AS-AR 3917 -440 AR-AQ 3917 -440 AQ-AP 3916 -440 AP-AO 3916 -440 AO-AN 2982 -236 AN-AM 2982 -236 AM-AL 2982 -236 AL-AK 2982 -236 AK-AJ 2982 -236 Chords Tens. Comp. AJ-AI 2896 -226 AI-AH 2896 -226 AH-AG 2896 -226 AG-AF 2894 -225 AF-AE 2894 -225 AE-AD 2894 -225 AD-AC 3443 -365 AC-AB 3443 -365 AB-AA 3438 -364 AA- Z 3441 -365 Z - X 3446 - 367 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D -AS 355 -1650 AS-AU 2508 -591 AV-AW 2586 -603 AW- F 2571 -597 F -AX 242 -1108 Webs Tens. Comp. BE-AJ 272 -1267 N -AJ 2077 - 431 AJ-BF 222 -1009 BG-BH 220 -1003 BI- Q 212 -963 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.90 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.380 AR 999 240 VERT(CL): 0.590 AR 787 180 HORZ(LL): 0.107 Z - - HORZ(TL): 0.166 Z - - Creep Factor: 2.0 Max TC CSI: 0.752 Max BC CSI: 0.831 Max Web CSI: 0.692 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:E3 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259947 / T14 / GABL FROM: Page 1 of 2 DRW: ... / ... 02/04/2020 T2 B1 W2 W5 W6 W7 (a)(a) A B C D E F G H I J K L M N O P Q R ST U V W X Y ZAAABACADAEAFAGAHAIAJAKALAMANAOAPAQARASAT AU AV AW AXAY AZ BA BBBC BDBE BFBG BH BI BJ BK BL BM 4 12 7 12 4X12(B7RT) 8X8(R) 4X12 4X8 3X6 7X14(R)H0312 2X4(**) 4X6 5X6 5X8 7X14(R) H0312 2X4(**) 3X6 3X6(**) 4X6(**) 5X8(B7RT) 39' 2'6"4'2'(TYP) 4' 4'6-9/16" 4'6-9/16" 9'10-3/8" 5'3-13/16" 15'2-3/16" 5'3-13/16" 20'6" 5'3-13/16" 26'6-1/8" 6'0-1/8" 32'6" 5'11-7/8" 32'6-5/16" 0-5/16" 39' 6'5-11/16" 4'6-9/16" 4'6-9/16" 12'6-1/4" 7'11-3/4" 20'6" 7'11-3/4" 29'6-3/16" 9'0-3/16" 39' 9'5-13/16"1'9"1' 3-15/16"4-5/16" 1'10-1/8" 11 ' 1 - 1 3 / 1 6 " 11 ' 8 - 9 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org AY-AO 242 -1113 AO-AZ 1135 -248 BA- K 1175 -254 K -BB 263 -1223 BC-BD 272 -1269 Q -BJ 631 -146 BK-AD 621 -144 AD-BL 137 -517 BM- U 132 -479 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. C -AT 84 -103 AU-AR 64 -34 E -AV 73 -170 AW-AQ 24 -25 AX- G 185 -23 AP-AY 196 -23 I -AO 61 -236 AZ-AM 161 -11 J -BA 126 -4 BB- L 41 -69 AL-BC 57 -14 BD- M 47 -138 AK-BE 46 -113 Gables Tens. Comp. BF-AI 44 -98 O -BG 46 -133 BH-AH 46 -112 P -BI 52 -162 AG- Q 262 -34 BJ- R 50 -156 AE-BK 49 -144 BL-AC 49 -136 S -BM 54 -181 AB- U 203 -41 AA- V 46 -102 Z - W 48 -97 Job Number:PB201526 FAIRES Truss Label:E3 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259947 / T14 / GABL FROM: Page 2 of 2 DRW: ... / ... 02/04/2020 PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W8 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWG VAL160101014 for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL S* 122 /- /- /37 /8 /6 Wind reactions based on MWFRS S Brg Width = 386 Min Req = - Bearing A Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 109 -147 B - C 109 -140 C - D 102 -116 D - E 90 -94 E - F 95 -79 F - G 88 -78 G - H 115 -83 H - I 160 -94 I - J 206 -113 Chords Tens. Comp. J - K 206 -113 K - L 160 -94 L - M 115 -83 M - N 71 -78 N - O 65 -49 O - P 60 -82 P - Q 72 -86 Q - R 78 -109 R - S 80 -117 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A -AH 135 -92 AH-AG 135 -95 AG-AF 135 -96 AF-AE 135 -97 AE-AD 135 -98 AD-AC 111 -73 AC-AB 111 -73 AB-AA 112 -73 Chords Tens. Comp. AA- Z 112 -73 Z - Y 111 -73 Y - X 111 -72 X - W 110 -72 W - V 109 -71 V - U 109 -70 U - T 108 -69 T - S 109 -66 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B -AH 48 -193 C -AG 65 -210 D -AF 62 -218 F -AE 63 -225 G -AD 63 -248 H -AC 64 -318 I -AB 67 -376 J -AA 0 -209 Webs Tens. Comp. Z - K 67 -376 Y - L 64 -318 X - M 63 -248 W - N 63 -225 V - P 62 -218 U - Q 65 -210 T - R 48 -193 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.22 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.003 K 999 240 VERT(CL): 0.005 K 999 180 HORZ(LL): 0.002 L - - HORZ(TL): 0.003 L - - Creep Factor: 2.0 Max TC CSI: 0.085 Max BC CSI: 0.035 Max Web CSI: 0.431 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:V1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259967 / T15 / VAL FROM:DRW: ... / ... 02/04/2020 W8 (a) A B C D E F G H I J K L M N O P Q R S TUVWXYZAAABACADAEAFAGAH 7 12 3X6(D1)2X4 2X4 2X4 2X4 2X4 2X4 3X6 2X4 2X4 2X4 5X6 2X4 2X4 2X4 2X4 4X6(R) 2X4 2X4 2X4 2X4 2X4 5X6 2X4 2X4 2X43X6 2X4 2X4 2X4 2X4 2X4 2X4 3X6(D1) 32'2-3/8" 2'1-3/16" 2'1-3/16" 4'1-3/16" 2'6'1-3/16" 2' 8'1-3/16" 2'10'1-3/16" 2' 12'1-3/16" 2'14'1-3/16" 2' 16'1-3/16" 2'18'1-3/16" 2' 20'1-3/16" 2'22'1-3/16" 2' 24'1-3/16" 2'26'1-3/16" 2' 28'1-3/16" 2'30'1-3/16" 2' 32'2-3/8" 2'1-3/16" 2'1-3/16" 2'1-3/16" 4'1-3/16" 2'6'1-3/16" 2' 8'1-3/16" 2'10'1-3/16" 2' 12'1-3/16" 2'14'1-3/16" 2' 16'1-3/16" 2'18'1-3/16" 2' 20'1-3/16" 2'22'1-3/16" 2' 24'1-3/16" 2'26'1-3/16" 2' 28'1-3/16" 2'30'1-3/16" 2' 32'2-3/8" 2'1-3/16" 0-1/4" 9' 4 - 1 5 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud :W8 2x4 DF-L #1&Bet.: Bracing (a) Continuous lateral restraint equally spaced on member. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWG VAL160101014 for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL S* 122 /- /- /37 /8 /6 Wind reactions based on MWFRS S Brg Width = 386 Min Req = - Bearing A Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 109 -147 B - C 109 -140 C - D 102 -116 D - E 90 -94 E - F 95 -79 F - G 88 -78 G - H 115 -83 H - I 160 -94 I - J 206 -113 Chords Tens. Comp. J - K 206 -113 K - L 160 -94 L - M 115 -83 M - N 71 -78 N - O 65 -49 O - P 60 -82 P - Q 72 -86 Q - R 78 -109 R - S 80 -117 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A -AH 135 -92 AH-AG 135 -95 AG-AF 135 -96 AF-AE 135 -97 AE-AD 135 -98 AD-AC 111 -73 AC-AB 111 -73 AB-AA 112 -73 Chords Tens. Comp. AA- Z 112 -73 Z - Y 111 -73 Y - X 111 -72 X - W 110 -72 W - V 109 -71 V - U 109 -70 U - T 108 -69 T - S 109 -66 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B -AH 48 -193 C -AG 65 -210 D -AF 62 -218 F -AE 63 -225 G -AD 63 -248 H -AC 64 -318 I -AB 67 -376 J -AA 0 -209 Webs Tens. Comp. Z - K 67 -376 Y - L 64 -318 X - M 63 -248 W - N 63 -225 V - P 62 -218 U - Q 65 -210 T - R 48 -193 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.22 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.003 K 999 240 VERT(CL): 0.005 K 999 180 HORZ(LL): 0.002 L - - HORZ(TL): 0.003 L - - Creep Factor: 2.0 Max TC CSI: 0.085 Max BC CSI: 0.035 Max Web CSI: 0.431 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:V1 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259967 / T15 / VAL FROM:DRW: ... / ... 02/04/2020 W8 (a) A B C D E F G H I J K L M N O P Q R S TUVWXYZAAABACADAEAFAGAH 7 12 3X6(D1)2X4 2X4 2X4 2X4 2X4 2X4 3X6 2X4 2X4 2X4 5X6 2X4 2X4 2X4 2X4 4X6(R) 2X4 2X4 2X4 2X4 2X4 5X6 2X4 2X4 2X43X6 2X4 2X4 2X4 2X4 2X4 2X4 3X6(D1) 32'2-3/8" 2'1-3/16" 2'1-3/16" 4'1-3/16" 2'6'1-3/16" 2' 8'1-3/16" 2'10'1-3/16" 2' 12'1-3/16" 2'14'1-3/16" 2' 16'1-3/16" 2'18'1-3/16" 2' 20'1-3/16" 2'22'1-3/16" 2' 24'1-3/16" 2'26'1-3/16" 2' 28'1-3/16" 2'30'1-3/16" 2' 32'2-3/8" 2'1-3/16" 2'1-3/16" 2'1-3/16" 4'1-3/16" 2'6'1-3/16" 2' 8'1-3/16" 2'10'1-3/16" 2' 12'1-3/16" 2'14'1-3/16" 2' 16'1-3/16" 2'18'1-3/16" 2' 20'1-3/16" 2'22'1-3/16" 2' 24'1-3/16" 2'26'1-3/16" 2' 28'1-3/16" 2'30'1-3/16" 2' 32'2-3/8" 2'1-3/16" 0-1/4" 9' 4 - 1 5 / 1 6 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWG VAL160101014 for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL M* 120 /- /- /37 /8 /6 Wind reactions based on MWFRS M Brg Width = 336 Min Req = - Bearing A Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 118 -101 B - C 86 -71 C - D 99 -50 D - E 102 -41 E - F 130 -50 F - G 176 -69 Chords Tens. Comp. G - H 176 -69 H - I 130 -50 I - J 102 -41 J - K 99 -50 K - L 86 -71 L - M 118 -101 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - X 102 -82 X - W 105 -85 W - V 107 -86 V - U 108 -87 U - T 109 -88 T - S 109 -89 Chords Tens. Comp. S - R 109 -89 R - Q 109 -88 Q - P 108 -87 P - O 107 -86 O - N 105 -85 N - M 102 -82 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - X 91 -333 C - W 55 -175 D - V 64 -248 E - U 64 -307 F - T 68 -370 G - S 0 -258 Webs Tens. Comp. R - H 68 -370 Q - I 64 -307 P - J 64 -248 O - K 55 -175 N - L 91 -333 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.009 N 999 240 VERT(CL): 0.014 N 999 180 HORZ(LL): -0.003 N - - HORZ(TL): 0.005 N - - Creep Factor: 2.0 Max TC CSI: 0.167 Max BC CSI: 0.121 Max Web CSI: 0.307 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:V2 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259971 / T16 / VAL FROM:DRW: ... / ... 02/04/2020 A B C D E F G H I J K L M NOPQRSTUVWX 7 12 2X4(D8R) 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 4X6 5X6 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4(D8R) 28'0-7/16" 4'0-3/16" 4'0-3/16" 6'0-3/16" 2' 8'0-3/16" 2'10'0-3/16" 2' 12'0-3/16" 2'14'0-3/16" 2' 16'0-3/16" 2'18'0-3/16" 2' 20'0-3/16" 2'22'0-3/16" 2' 24'0-3/16" 2'28'0-7/16" 4'0-3/16" 4'0-3/16" 4'0-3/16" 6'0-3/16" 2' 8'0-3/16" 2'10'0-3/16" 2' 12'0-3/16" 2'14'0-3/16" 2' 16'0-3/16" 2'18'0-3/16" 2' 20'0-3/16" 2'22'0-3/16" 2' 24'0-3/16" 2'28'0-7/16" 4'0-3/16" 0-1/4" 8' 2 - 3 / 8 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 3.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Additional Notes See DWG VAL160101014 for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL M* 120 /- /- /37 /8 /6 Wind reactions based on MWFRS M Brg Width = 336 Min Req = - Bearing A Fcperp = 625psi. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 118 -101 B - C 86 -71 C - D 99 -50 D - E 102 -41 E - F 130 -50 F - G 176 -69 Chords Tens. Comp. G - H 176 -69 H - I 130 -50 I - J 102 -41 J - K 99 -50 K - L 86 -71 L - M 118 -101 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - X 102 -82 X - W 105 -85 W - V 107 -86 V - U 108 -87 U - T 109 -88 T - S 109 -89 Chords Tens. Comp. S - R 109 -89 R - Q 109 -88 Q - P 108 -87 P - O 107 -86 O - N 105 -85 N - M 102 -82 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - X 91 -333 C - W 55 -175 D - V 64 -248 E - U 64 -307 F - T 68 -370 G - S 0 -258 Webs Tens. Comp. R - H 68 -370 Q - I 64 -307 P - J 64 -248 O - K 55 -175 N - L 91 -333 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.009 N 999 240 VERT(CL): 0.014 N 999 180 HORZ(LL): -0.003 N - - HORZ(TL): 0.005 N - - Creep Factor: 2.0 Max TC CSI: 0.167 Max BC CSI: 0.121 Max Web CSI: 0.307 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:V2 Ply: 1 Qty: 1 Wgt: 0.0 lbs SEQN: 259971 / T16 / VAL FROM:DRW: ... / ... 02/04/2020 A B C D E F G H I J K L M NOPQRSTUVWX 7 12 2X4(D8R) 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 4X6 5X6 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4(D8R) 28'0-7/16" 4'0-3/16" 4'0-3/16" 6'0-3/16" 2' 8'0-3/16" 2'10'0-3/16" 2' 12'0-3/16" 2'14'0-3/16" 2' 16'0-3/16" 2'18'0-3/16" 2' 20'0-3/16" 2'22'0-3/16" 2' 24'0-3/16" 2'28'0-7/16" 4'0-3/16" 4'0-3/16" 4'0-3/16" 6'0-3/16" 2' 8'0-3/16" 2'10'0-3/16" 2' 12'0-3/16" 2'14'0-3/16" 2' 16'0-3/16" 2'18'0-3/16" 2' 20'0-3/16" 2'22'0-3/16" 2' 24'0-3/16" 2'28'0-7/16" 4'0-3/16" 0-1/4" 8' 2 - 3 / 8 " PB201526PC207467 FAIRES-SCOTT STOKER **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 407 /- /- /131 /26 /42 D 410 /- /- /106 /26 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 3.5 Min Req = 1.5 Bearings B & D are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 61 0 B - C 62 -232 Chords Tens. Comp. C - D 63 -231 D - E 61 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 178 -22 Chords Tens. Comp. F - D 178 -22 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 57 0 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.001 F 999 240 VERT(CL): 0.002 F 999 180 HORZ(LL): 0.001 F - - HORZ(TL): 0.001 F - - Creep Factor: 2.0 Max TC CSI: 0.127 Max BC CSI: 0.047 Max Web CSI: 0.018 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:DORM Ply: 1 Qty: 6 Wgt: 0.0 lbs SEQN: 259983 / T28 / COMN FROM:DRW: ... / ... 02/04/2020 A B C D E F 6 12 2X4(A1T) 4X6 2X4 2X4(A1T) 3'10"2" 2' 2' 4' 2' 2' 2' 4' 2'1'1' 4-5/16"1' 4 - 5 / 1 6 " 1' 9 - 1 5 / 1 6 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Lumber Top chord 2x4 DF-L #1&Bet. Bot chord 2x4 DF-L #1&Bet. Webs 2x4 DF-L Stud Loading Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied per IRC-15 section 301.5. Truss designed for unbalanced snow loads. Wind Member design based on both MWFRS and C&C. Right cantilever is exposed to wind Additional Notes Top Chord overhang(s) may be field trimmed. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 407 /- /- /131 /26 /42 D 410 /- /- /106 /26 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 3.5 Min Req = 1.5 Bearings B & D are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 61 0 B - C 62 -232 Chords Tens. Comp. C - D 63 -231 D - E 61 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 178 -22 Chords Tens. Comp. F - D 178 -22 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 57 0 Loading Criteria (psf) TCLL: 35.00 TCDL: 8.00 BCLL: 0.00 BCDL: 8.00 Des Ld: 51.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.8 psf BCDL: 4.8 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: 35.0 Ct: - CAT: - Pf: 35.0 Ce: - Lu: - Cs: - Snow Duration: - Code / Misc Criteria Bldg Code: IRC 2015 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.001 F 999 240 VERT(CL): 0.002 F 999 180 HORZ(LL): 0.001 F - - HORZ(TL): 0.001 F - - Creep Factor: 2.0 Max TC CSI: 0.127 Max BC CSI: 0.047 Max Web CSI: 0.018 Mfg Specified Camber: VIEW Ver: 18.02.01.0118.17 Job Number:PB201526 FAIRES Truss Label:DORM Ply: 1 Qty: 6 Wgt: 0.0 lbs SEQN: 259983 / T28 / COMN FROM:DRW: ... / ... 02/04/2020 A B C D E F 6 12 2X4(A1T) 4X6 2X4 2X4(A1T) 3'10"2" 2' 2' 4' 2' 2' 2' 4' 2'1'1' 4-5/16"1' 4 - 5 / 1 6 " 1' 9 - 1 5 / 1 6 "