HomeMy WebLinkAboutRESCHECK - 20-00798 - 977 McJon Ln - New SFRREScheck Software Version 4.7.1
Compliance Certificate
Project T. Webb Construction - Mason Res.
Energy Code:2015 IECC
Location:Rexburg, Idaho
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:3,538 ft2
Glazing Area 17%
Climate Zone:6 (8693 HDD)
Permit Date:
Construction Site:Owner/Agent:
T. Webb Construction- Mason
Residence
Designer/Contractor:
Freedom Heating, Inc.
Freedom Heating, Inc.
P.O Box 51966
Idaho Falls, ID 83405
208-339-0344
Freedomheatinginc@yahoo.com
Permit Number:
Compliance: Passes using UA trade-off
5.4% Better Than Code Maximum UA:295 Your UA:279
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Wall 1: Wood Frame, 16" o.c.436 21.0 0.0 0.057 20
Door 1: Solid 42 0.140 6
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 40 0.260 10
Wall 2: Wood Frame, 16" o.c.360 21.0 0.0 0.057 19
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.260 7
Wall 3: Wood Frame, 16" o.c.436 21.0 0.0 0.057 18
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 120 0.260 31
Wall 4: Wood Frame, 16" o.c.360 21.0 0.0 0.057 17
Door 1: Solid 21 0.140 3
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 35 0.260 9
Basement Wall 1: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 6.5'
Insulation depth: 9.0'
484 19.0 0.0 0.048 23
Basement Wall 2: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 6.5'
Insulation depth: 9.0'
380 19.0 0.0 0.048 17
Project Title: T. Webb Construction - Mason Res.
Data filename: C:\Users\Freedom Heating\AppData\Local\Check\REScheck\T. Webb Construction - Mason
Res..rck
Page 1 of 2
10/08/20Report date:
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.260 4
Basement Wall 3: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 6.5'
Insulation depth: 9.0'
484 19.0 0.0 0.048 22
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.260 4
Basement Wall 4: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 6.5'
Insulation depth: 9.0'
380 19.0 0.0 0.048 17
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.260 4
Ceiling 1: Flat Ceiling or Scissor Truss 1,839 50.0 0.0 0.026 48
Freedom Heating,
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.7.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Job Number: T. Webb Construction- Mason Residence
INFORMATION CONTAIN WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE
VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID.
Project Title: T. Webb Construction - Mason Res.
Data filename: C:\Users\Freedom Heating\AppData\Local\Check\REScheck\T. Webb Construction - Mason
Res..rck
Page 2 of 2
10/08/20Report date:
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
21.00Above-Grade Wall
19.00Below-Grade Wall
0.00Floor
50.00Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.26Window
0.14Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name:Date:
Comments