HomeMy WebLinkAboutPLANS REDLINED REVISIONS - 20-00791 - 127 N 4th E Units 1 & 2 - A Greener Door DuplexAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Alan Parkinson Alan.Parkinson@rexburg.org 208-372-2165
Description : 127 N 4th E Units 1 & 2 - A Greener Door DuplexAddress : 127 N 4th E Units 1 & 2Application Type : Document Filename : 0917GreenDoor_PermitDwgs.pdf Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report Revisions Required
Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments
A-1 Free text Larry Beesley : Building Open 2 SD
A-1 Free text Larry Beesley : Building Open 2 SD CO
A-1 Free text Larry Beesley : Building Open 2 SD
A-1 Free text Larry Beesley : Building Open 2 SD
A-1 Free text Larry Beesley : Building Open 2 SD
A-1 Free text Larry Beesley : Building Open 2 SD CO
A-1 Free text Larry Beesley : Building Open 2 SD
A-1 Free text Larry Beesley : Building Open 2 SD
A-1 Free text Larry Beesley : Building Open 2 F
A-1 Free text Larry Beesley : Building Open 2 F
A-1 Free text Larry Beesley : Building Open 2 F
A-1 Free text Larry Beesley : Building Open 2 F
A-1 Free text Larry Beesley : Building Open 2 Attic Access 22"x30" minimum access where attic clear heightexceeds 30" (R807)
# 20-00791Building New Duplex
You will need to provide more details on the footings and foundation, floors,TJIs and or slab on grade with in floor heat. Also pony and bearing walls and footings as needed.
Report Date: 07-10-2020
Approval of plans does not constitute approval of variance from code
Page 1 of 2
Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments
A-1 Free text Larry Beesley : Building Open 2 Attic Access 22"x30" minimum access where attic clear heightexceeds 30" (R807)
A-1 Free text Larry Beesley : Building Open 2 SMOKE DETECTOR REQUIRED
A-2 Free text Larry Beesley : Building Open 3 FOOTING AND FOUNDATION WALL REQUIRED
A-2 Free text Larry Beesley : Building Open 3 YOU NEED TO SHOW BEARING PONE WALL FOOTINGS ANDDETAILS OF THE SIZE OF ALL FOOTINGS AND FOUNDATIONS
A-2 Free text Larry Beesley : Building Open 3 X X
A-2 Free text Larry Beesley : Building Open 3 X X
A-2 Free text Larry Beesley : Building Open 3 X X
A-2 Free text Larry Beesley : Building Open 3 4200LB HOLD DOWNS
A-2 Free text Larry Beesley : Building Open 3 Radon Reduction System IRC Appendix F
A-2 Free text Larry Beesley : Building Open 3 Radon Reduction System IRC Appendix F
A-2 Free text Larry Beesley : Building Open 3 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"
A-3 Free text Larry Beesley : Building Open 4 Roof Trusses (designed according to R802.10.1) 35 # Snow and90 mph winds (Local Conditions)
A-4 Free text Larry Beesley : Building Open 5 Street NumberDisplayed on House
A-5 Free text Larry Beesley : Building Open 6 Ground Surface to Slope away from Foundation a minimum of6" within first 10 ft.
A-5 Free text Larry Beesley : Building Open 6 Roof Ventilation as per R806
A-5 Free text Larry Beesley : Building Open 6 Footing Depth (36" below finished grade and 12" belowundisturbed soil; 18" to top of slab - interior)
A-0 Free text Alan Parkinson : P&Z Open 1 7' Landscape Strip and 5' Sidewalk shall be provided
A-0 Free text Alan Parkinson : P&Z Open 1 Front yard shall not have more than 40% covered by concreteor asphalt in the Low Density Residential 2 (LDR2) Zone. If youpush the house back a little this should help satisfy thisrequirement.
A-0 Free text Alan Parkinson : P&Z Open 1 Public Works requires the Right of Way to encompass 12'behind back of curb. To address this, please contact the PublicWorks Department.
Report Date: 07-10-2020
Approval of plans does not constitute approval of variance from code
Page 2 of 2
Powered by TCPDF (www.tcpdf.org)
4
t
h
E
A
S
T
84
.
9
'
189'
2016
09/17/20
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
4T
H
E
A
S
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
Gr
e
e
n
D
o
o
r
DATE:
PROJECT:
REVISION
DATES:
T
W
I
N
H
O
U
S
E
A-0
SI
T
E
L
A
Y
O
U
T
4th East, Rexburg Idaho 83440
Green Door Duplex
7' Landscape Strip
and 5' Sidewalk shall
be provided
Front yard shall not have more than 40%
covered by concrete or asphalt in the Low
Density Residential 2 (LDR2) Zone. If you
push the house back a little this should
help satisfy this requirement.
Public Works requires the
Right of Way to encompass 12'
behind back of curb. To
address this, please contact
the Public Works Department.
MASTER
14'0" X 12'5"
#3/OFFICE
BEDROOM #2
14'0" X 11'1"
11'8" X 12'9"
LIVING
16'6" X 15'8"
KITCH/DIN.
16'6" X 17'9"
REF
WIC
COV. PATIO
16'7" X 8'0"
LDY.
6'7" X 9'0"
DW
MW
2-CAR GARAGE
23'1" x 23'8"
WINDOW SCHEDULE
SYM.SIZE
DOOR SCHEDULE
SYM.SIZE NOTESTYPE
TYPE NOTESQTY
HARDWARE
PTY.
3'9" X 6'8"
MASTER
14'0" X 12'5"
#3/OFFICE
BEDROOM #2
14'0" X 11'1"
11'8" X 12'9"
LIVING
16'6" X 15'8"
KITCH/DIN.
16'6" X 17'9"
REF
WIC
COV. PATIO
16'7" X 8'0"
LDY.
6'7" X 9'0"
MW
2-CAR GARAGE
23'1" x 23'8"
COVERED PATIO
14'9" X 6'0"
PTY.
3'9" X 6'8"
2016
09/17/20
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
4T
H
E
A
S
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
Gr
e
e
n
D
o
o
r
DATE:
PROJECT:
REVISION
DATES:
T
W
I
N
H
O
U
S
E
FL
O
O
R
P
L
A
N
A-1
SD
SD CO
SD
SD SD
SD CO
SD
SD
F
F
F
F
Attic Access 22"x30" minimum
access where attic clear height
exceeds 30" (R807)
Attic Access 22"x30" minimum
access where attic clear height
exceeds 30" (R807)
SMOKE DETECTOR
REQUIRED
GARAGE SLAB GARAGE SLAB
HOUSE SLAB
2016
09/17/20
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
4T
H
E
A
S
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
Gr
e
e
n
D
o
o
r
DATE:
PROJECT:
REVISION
DATES:
T
W
I
N
H
O
U
S
E
FO
U
N
D
A
T
I
O
N
A-2
FOOTING AND FOUNDATION
WALL REQUIRED
YOU NEED TO SHOW BEARING PONE WALL FOOTINGS AND
DETAILS OF THE SIZE OF ALL FOOTINGS AND FOUNDATIONS
X X X X X X
4200LB HOLD DOWNS
Radon Reduction System
IRC Appendix F Radon Reduction System
IRC Appendix F
Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in
Top 12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in
Top 6"
2016
09/17/20
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
4T
H
E
A
S
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
Gr
e
e
n
D
o
o
r
DATE:
PROJECT:
REVISION
DATES:
T
W
I
N
H
O
U
S
E
RO
O
F
L
A
Y
O
U
T
A-3
Roof Trusses (designed according to R802.10.1)
35 # Snow and 90 mph winds (Local Conditions)
EAST ELEVATION
SOUTH SIDE ELEVATION 2016
09/17/20
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
4T
H
E
A
S
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
Gr
e
e
n
D
o
o
r
DATE:
PROJECT:
REVISION
DATES:
T
W
I
N
H
O
U
S
E
A-4
EX
T
E
R
I
O
R
EL
E
V
A
T
I
O
N
S
Street Number
Displayed on House
WEST ELEVATION
NORTH SIDE ELEVATION
2016
09/17/20
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
4T
H
E
A
S
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
Gr
e
e
n
D
o
o
r
DATE:
PROJECT:
REVISION
DATES:
T
W
I
N
H
O
U
S
E
A-5
EX
T
E
R
I
O
R
EL
E
V
A
T
I
O
N
S
Ground Surface to Slope away from Foundation a minimum of 6" within first 10
ft.
Roof Ventilation as per
R806
Footing Depth (36" below finished grade and 12"
below undisturbed soil; 18" to top of slab - interior)