HomeMy WebLinkAboutCONCRETE TEST 10 - 19-00723 - Mountain America Credit Union Office - Call CenterProject Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength 5,804 PSI MACU Call Center MACU 500F 20023 18397 6.5 yds Flyash, MP 322, MA AE 90 D. Aust 10/08/2020 8:00 AM 3 4.5 65 45 418A 418E 418C 418B 418D 4 4 4 4 10/15/20 11/05/20 11/05/20 11/05/20 50,500 72,815 74,435 71,655 2 5,0004,017 5,792 5,921 5,700 Digitally signed by Jacob Christensen Date: 2020.11.05 08:16:43 -07'00' 12.57 Walter's Ready Mix Curbing on the North side of building 7 28 28 28 H 12.57 12.57 12.57 140 1 L. Steiner 10/09/2020 1 1 2