Loading...
HomeMy WebLinkAboutPLANS REDLINED REVISIONS - 20-00648 - Valley Ag Fertilizer Plant - AdditionAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Alan Parkinson Alan.Parkinson@rexburg.org 208-372-2165 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Valley Ag Fertilizer Plant - AdditionAddress : 2003 S Yellowstone HwyApplication Type : Document Filename : PLANS - 20-00648 - Valley Ag Fertilizer Plant - Addition.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments C2 Free text Cody Jones : Building Open 2 Slope grade away from foundation 6" in first 10 '. S1.1 Callout Cody Jones : Building Open 4 Need to identify special inspector S1.1 Callout Cody Jones : Building Open 4 Needs to comply with 1805. S1.2 Callout Cody Jones : Building Open 5 Glazing adjacent to stairways to be considered hazardous.2406.4.6 S1.2 Callout Cody Jones : Building Open 5 Railing on catwalk to be compliant with section 1015. S1.3 Callout Cody Jones : Building Open 6 will need to see Foundation plan with wall specifications forconstruction. S1.3 Free text Cody Jones : Building Open 6 Frost depth of 36" per city ordinance. S3.2 Free text Cody Jones : Building Open 10 Section 718.4.3 Draft stopping should be installed in attics andconcealed roof spaces, such that any horizontal area does notexceed 3000 square feet. S4.4 Free text Cody Jones : Building Open 14 Needs to be 44' min. # 20-00648Madison County - Commercial Addition Report Date: 09-09-2020 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments S4.4 Free text Cody Jones : Building Open 14 Stair riser height shall be 7 inches max 4inches min. Treaddepth of 11 inches minimum. G1 Free text Stan Crittenden : Fire Open 3 Due to the size of the addition and the total square footage ofthe property IFC 2018 AppendixB & C requires that we install 3-4 fire hydrants. G1 Free text Stan Crittenden : Fire Open 3 International Fire code 503.1.1 (IFC 2018) requires that firedepartment requires access to with-in 150' of point of the exterior of the building. Thearea between the building and the Railroad tracks will need to meetrequirements to allow the Fire Trucks to drive in that area. G1 Free text Alan Parkinson : P&Z Open 3 Buffering from Highway 20 is required. Section 3.02.100.F.1.states Parcels directly adjacent to the Highway 20 right-of-waymust have buildings buffered with deciduous two (2”) inchcaliper trees at twenty (20’) feet spacing and two (2) shrubsbetween trees. Report Date: 09-09-2020 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) A C2 S89° 55' 11"W2640.93' S89° 53' 11"W2640.96' EXISTING FINISH FLOOR ELEV. = 2149.50± EXISTING FINISH FLOOR ELEV. = 2149.50± BOTTOM OF SWALE ELEV. = 2147.50 BOTTOM OF SWALE ELEV. = 2146.50 A C2 TOG = 2148.00± MATCH EX. TOG = 2149.00TOG = 2147.50± MATCH EX. TOG = 2147.90± MATCH EX. TOG = 2148.00± MATCH EX. TOG = 2149.00 TOG = 2147.50± MATCH EX. TOG = 2149.00 C2 JOB CLIENT VA L L E Y A G R O N O M I C S FE R T I L I Z E R S T O R A G E A D D I T I O N f o r 20 0 3 S . Y E L L O W S T O N E H W Y , R E X B U R G , I D 8 3 4 4 0 VA L L E Y W I D E C O O P E R A T I V E I n c . 2 1 1 4 N O R T H 2 0 t h S t r e e t NA M P A , I D A H O 8 3 6 8 7 D R A I N A G E & G R A D I N G P L A N C B A D E F 1 C B A D E F 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 11 N W 9 t h S t r e e t On t a r i o , O r e g o n 9 7 9 1 4 N O R T H W E S T , L L CGN I R E E N I G N E Scale: 1"=60' GRADING & DRAINAGE PLAN GRADING & DRAINAGE NOTES UTILITY NOTES Scale: NTS TYPICAL RETENTION SWALEA Slope grade away from foundation 6" in first 10 '. Scale: 1:80 PLOT PLAN SO U T H H I G H W A Y 1 9 1 S O U T H Y E L L O W S T O N E H W Y POLE LINE RD. NO R T H B O U N D SO U T H B O U N D 2020 BE L L C O R N E R R D 20 332 332 333 333 33 33 JOB CLIENT FE R T I L I Z E R S T O R A G E A D D I T I O N f o r 20 0 3 S Y e l l o w s t o n e H w y , R e x b u r g , I d a 8 3 4 4 0 21 1 4 N O R T H 2 0 t h S T R E E T NA M P A , I D A H O 8 3 6 8 7 C B A D E F 1 C B A D E F 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 G1 B S3 B S3 M 6 S8 EXIT NOTICE TO CONTRACTOR Buffering from Highway 20 is required. Section 3.02.100.F.1. states Parcels directly adjacent to the Highway 20 right-of-way must have buildings buffered with deciduous two (2”) inch caliper trees at twenty (20’) feet spacing and two (2) shrubs between trees. International Fire code 503.1.1 (IFC 2018) requires that fire department requires access to with-in 150' of point of the exterior of the building. The area between the building and the Railroad tracks will need to meet requirements to allow the Fire Trucks to drive in that area. Due to the size of the addition and the total square footage of the property IFC 2018 Appendix B & C requires that we install 3-4 fire hydrants. Scale: 1/16"=1'-0" BULK STORAGE OVER ALL FLOOR PLAN Ç Å Æ È Ç Å Æ È Ç Å Æ È Ç Å Æ È Å Æ Ç Å Æ È Ç Å Æ È Ç Å Æ È Ç Å Æ È Ç Å Æ È Ç Å Æ È Ç Å Æ È Ç Å Æ È Ç Å Æ È Å Æ Ç Å Æ È Ç Å Æ È Å Æ G 16 16 1616 789101112 F A E D B 131415 9 1012131415 0 0 11 C F H H H JOB CLIENT FE R T I L I Z E R S T O R A G E A D D I T I O N f o r 20 0 3 S Y e l l o w s t o n e H w y , R e x b u r g , I d a 8 3 4 4 0 21 1 4 N O R T H 2 0 t h S T R E E T NA M P A , I D A H O 8 3 6 8 7 C B A D E F 1 C B A D E F 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 S1.1 STRUCTURAL NOTES Need to identify special inspector Needs to comply with 1805. Scale: 3/16"=1'-0" PARTIAL CLERESTORY FLOOR FRAMING PLAN 6 1 2345 D C 6 78 9 H G H G F à EXIT JOB CLIENT FE R T I L I Z E R S T O R A G E A D D I T I O N f o r 20 0 3 S Y e l l o w s t o n e H w y , R e x b u r g , I d a 8 3 4 4 0 21 1 4 N O R T H 2 0 t h S T R E E T NA M P A , I D A H O 8 3 6 8 7 C B A D E F 1 C B A D E F 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 S1.2 Scale: 3/16"=1'-0" ENLARGED LOAD-OUT FLOOR PLAN01 Scale: 1/4"=1'-0" OFFICE FLOOR PLAN02Scale: 1/4"=1'-0" OFFICE FLOOR FRAMING PLAN Glazing adjacent to stairways to be considered hazardous. 2406.4.6 Railing on catwalk to be compliant with section 1015. Scale: 3/32"=1'-0" FOUNDATION PLAN 1616 789101112 E D B 131415 78 9 101213141511 C H 16 6 1 A F G H A F JOB CLIENT FE R T I L I Z E R S T O R A G E A D D I T I O N f o r 20 0 3 S Y e l l o w s t o n e H w y , R e x b u r g , I d a 8 3 4 4 0 21 1 4 N O R T H 2 0 t h S T R E E T NA M P A , I D A H O 8 3 6 8 7 C B A D E F 1 C B A D E F 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 S1.3 FOOTING SCHEDULE FTG DETAIL FOOTING DIM'S FOOTING REINFORCEMENT T.O.F. ELV.A.B. SIZEPEDESTAL DIM'S PEDESTAL REINFORCEMENTHAIRPIN REINFORCEMENT Frost depth of 36" per city ordinance. will need to see Foundation plan with wall specifications for construction. Scale: 7/32"=1'-0" BUILDING SECTIONC HGFEDCBA 30 ft. 29 ft. 28 ft. 27 ft. 26 ft. 25 ft. 24 ft. 23 ft. 22 ft. 21 ft. 20 ft. 19 ft. 18 ft. 17 ft. 16 ft. 15 ft. 14 ft. 13 ft. 12 ft. 7/32"=1'-0" BUILDING SECTIOND 8 7 6989 7/32"=1'-0" BUILDING SECTIONE JOB CLIENT FE R T I L I Z E R S T O R A G E A D D I T I O N f o r 20 0 3 S Y e l l o w s t o n e H w y , R e x b u r g , I d a 8 3 4 4 0 21 1 4 N O R T H 2 0 t h S T R E E T NA M P A , I D A H O 8 3 6 8 7 C B A D E F 1 C B A D E F 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 S3.2 Section 718.4.3 Draft stopping should be installed in attics and concealed roof spaces, such that any horizontal area does not exceed 3000 square feet. 6 Gr Gr 1 Gr JOB CLIENT FE R T I L I Z E R S T O R A G E A D D I T I O N f o r 20 0 3 S Y e l l o w s t o n e H w y , R e x b u r g , I d a 8 3 4 4 0 21 1 4 N O R T H 2 0 t h S T R E E T NA M P A , I D A H O 8 3 6 8 7 C B A D E F 1 C B A D E F 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 S4.4 Stair riser height shall be 7 inches max 4inches min. Tread depth of 11 inches minimum. Needs to be 44' min.