HomeMy WebLinkAboutLAYOUT PLAN REDLINED - 20-00572 - 62 Aries Dr Units 1 & 2 - Duplex ConversionAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Description : 62 Aries Dr - Duplex ConversionAddress : 62 Aries StRecord Type : Duplex ConversionDocument Filename : Screenshot_20200727-154949_STANLEY Floor Plan.jpg
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report Approved
# 20-00572
Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments
Pg 1 Free text Larry Beesley : Building Open 1 SD
Pg 1 Free text Larry Beesley : Building Open 1 SD
Pg 1 Free text Larry Beesley : Building Open 1 SDOO
Pg 1 Free text Larry Beesley : Building Open 1 SMOKE DETECTOR REQUIRED
Duplex Conversion
The ceilings must have 2 layers of 5/8" type X drywall for the fire separation. Smoke detectors must be hard wired with battery backup. Egress windows in the bedrooms. You willneed a 2A10BC Fire extinguisher hanging in the kitchen of both units.
Approval of plans does not constitute approval of variance from code
Powered by TCPDF (www.tcpdf.org)
SD
SD
SD
OO
SMOKE
DETECTOR
REQUIRED