HomeMy WebLinkAboutPROJECT INFORMATION - 08-00179 - 3091 N 500 E - MechanicalShort rorm Entire House 1 r Hollist Constuction Project Information For: Dalling Residence Rexburg, ID 83440 • • t ■ • u . Job: Date: Apr 14, 2008 By: Htg Clg Infiltration Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 Moisture difference (gr/Ib) -31 HEATING EQUIPMENT Make AmStd Trade Freedom 90 Model ALIC100C948B` Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE Area (fl') 100000 Btuh 94000 Btuh 79 OF 1281 cfm 0.025 cfm/Btuh 0.80 in H2O COOLING EQUIPMENT Make Am Std Area (fl') Htg load (Btuh) Trade Allegiance 13 Htg AVF (cfm) Cig AVF (cfm) Cond 2A7A3036A1 213 2305 Coil 2TXCB048 AC3HCA 57 34 Efficiency 13 SEER 8 Sensible cooling 25060 Btuh Latent cooling 10740 Stub Total cooling 35800 Stub Actual air flow 1281 cfm Airflow factor 0.054 cfm/Btuh Static pressure 0.80 in H2O Load sensible heat ratio 1.00 113 ROOM NAME Area (fl') Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Cig AVF (cfm) bed 213 2305 633 57 34 clst.2 8 0 0 0 0 bed 2 190 2601 1795 64 97 great room 405 3473 863 86 47 dining 225 4584 I 2218 113 120 family room 374 4635 1407 114 I 76 kitchen 252 3788 3545 93 192 living 164 2953 1516 73 82 clst.1 8 0 0 0 0 stairs 1 48 1 0 0 0 0 entry 56 1780 805 44 44 mas bath 204 1992 551 49 30 bath 2 40 671 246 17 13 den 136 3449 1789 85 97 laundry 48 1025 1266 25 69 hall I 136 0 0 0 0 k.Aq AAQ cna7 n9nA GI JY ILJ IJI Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ghtsoft RightSule ReWenlial6.0.02RSR40615 2008 -Apr -1416:19:14 !t wnXM EAWrlghlsofl 1-1VACITemplateV3ill Hollist(Salem Housetrrp Calc =MJ8 011entatbn=N Page TOTALS 1 3760 I 57974 1 23313 1 1281 1 1281 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. �m„ wrrghtsoft RightSuite ResAten0a16.0.02 RSR40615 200&Apr 1416:19:14 EiWrghtwft HVACITemplatmBill Hdlist(Salem House).rrp Calc =MJ8 OriontaOon=N Paget office 88 3434 2095 85 113 mas cist. 48 0 0 0 0 mas bed 306 6557 1908 162 103 stairs 64 715 0 18 0 hall 36 168 0 4 0 pantry 80 0 0 0 0 bath 1 60 1053 0 26 0 utility 135 1666 254 41 14 hall 68 0 0 0 0 storage/mech 220 0 0 0 0 Entire House d 3760 51916 23685 1281 1281 Other equip loads 6058 1116 Equip. @ 0.94 RSM 23313 Latent cooling 0 TOTALS 1 3760 I 57974 1 23313 1 1281 1 1281 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. �m„ wrrghtsoft RightSuite ResAten0a16.0.02 RSR40615 200&Apr 1416:19:14 EiWrghtwft HVACITemplatmBill Hdlist(Salem House).rrp Calc =MJ8 OriontaOon=N Paget Building Analysis Entire House Hollist Constuction project Information For: Calling Residence Rexburg, ID 83440 Job: Date: Apr 14, 2008 By: Heating Component Wk - Btuh % of load Walls Location: Idaho Falls, ID, US 12720 Indoor: Indoor temperature (°F) Heating 70 Cooling 75 Elevation: 4741 ft 27.5 Design TD (°F) 76 14 Latitude: 440N Ceilings Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry, bulb (°F -6 89 Infiltration: Ducts Wetybulb (e oF) _ 634 ( H ) Method Simplified 0 Wind speed (mph) 15.0 7.5 Construction quality Fireplaces Average 0 0.0 Heating Component Btuh/ft' Btuh % of load Walls 4.4 12720 21.9 Glazing 43.3 15942 27.5 Doors 29.6 2697 4.7 Ceilings 2.0 4507 7.8 Floors 3.9 9003 15.5 Infiltration 3.6 7047 12.2 Ducts 0 0.0 Piping 0 0.0 Humidification 0 0.0 Ventilation 6058 10.4 Adjustments 0 Total 57974 100.0 Coolin Component Btuh/112 Btuh % of load Walls 0.3 761 3.1 Glazing 34.3 12627 50.9 Doors 7.2 657 2.6 Ceilings 1.1 2491 10.0 Floors 0.5 1244 5.0 Infiltration 0.4 695 2.8 Ducts 0 0.0 Ventilation 1116 4.5 Internal gains 5210 21.0 Blower 0 0.0 Adjustments 0 Total 24801 100.0 Overall U -value = 0.093 Btuh/ff' °F Data entries checked. ,� wnghtsoR R1ghtSudeResldenOalB.0.02RSR40815 2008 -Apr -1418:19:14 IC.Cp E1Wrlghtsoft WAMTemplatelBill Hollist(Salem House).rrp CaE=MJ8 Orlentallon=N Page Component Constructions Job: Date: Apr 14, 2008 Entire House By: Hollist Constuction Project Information For: Dalling Residence Rexburg, ID 83440 Construction descriptions Or Area B -value Insul R We HTM Loss Clg HTM Gain (M) aheW-F) (R FiBwh) (eww) (gem) (Bww) (Bath) Walls 12F-Osw: Wood stud frame, siding or stucco, no board insulation, R-21 cavity insulation 15A11-Oocw-10: Basement - open core block, wood stud framing, interior finish, R-11 cavity, no board insulation, 10' Partitions (none) Windows 1D-c2ow: Operable, clear glass, wood frame, 2 pane Doors 11 DO: Wood door, solid core, no storm Callings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation n Design Conditions 21.0 4.94 Location: 0.47 Indoor: Heating Cooling Idaho Falls, ID, US 21.0 Indoor temperature (°F) 70 75 Elevation: 4741 ft se Design TD (°F) 76 14 Latitude: 440N 252 Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: 51 0.065 We Daily b (eFS F) - - 34 60 ( H ) Method Simplified 24 Wind speed (mph) 15.0 7.5 Construction quality Fireplaces Average 0 4.94 Construction descriptions Or Area B -value Insul R We HTM Loss Clg HTM Gain (M) aheW-F) (R FiBwh) (eww) (gem) (Bww) (Bath) Walls 12F-Osw: Wood stud frame, siding or stucco, no board insulation, R-21 cavity insulation 15A11-Oocw-10: Basement - open core block, wood stud framing, interior finish, R-11 cavity, no board insulation, 10' Partitions (none) Windows 1D-c2ow: Operable, clear glass, wood frame, 2 pane Doors 11 DO: Wood door, solid core, no storm Callings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation n 564 0.065 21.0 4.94 2786 0.47 268 e 226 0.065 21.0 4.94 1114 0.47 107 se 51 0.065 21.0 4.94 252 0.47 24 s 492 0.065 21.0 4.94 2428 0.47 233 sw 51 0.065 21.0 4.94 252 0.47 24 w 221 0.065 21.0 4.94 1092 0.47 105 all 1604 0.065 21.0 4.94 7923 0.47 761 n 359 0.048 11.0 3.65 1310 0.00 0 e 236 0.048 11.0 3.65 861 0.00 0 s 459 0.048 11.0 3.65 1674 0.00 0 w 261 0.048 11.0 3.65 952 0.00 0 all 1315 0.048 11.0 3.65 4797 0.00 0 n 94 0.570 0.0 43.3 4072 18.6 1750 in 65 0.570 0.0 43.3 2816 18.6 1210 e 36 0.570 0.0 43.3 1538 60.4 2144 e 25 0.570 0.0 43.3 1083 60.4 1510 s 109 0.570 0.0 43.3 4700 33.2 3599 w 40 0.570 0.0 43.3 1733 60.4 2415 all 368 0.570 0.0 43.3 15942 34.3 12627 n 35 0.390 0.0 29.6 1037 7.21 253 n 35 0.390 0.0 29.6 1037 7.21 253 s 21 0.390 0.0 29.6 622 7.22 152 all 91 0.390 0.0 29.6 2697 7.22 657 2281 0.026 38.0 1.98 4507 1.09 2491 ` Wr1Cj NtS[pf[ RightSuke Resideolial8.0.02RSR40815 2008 -Apr -1418:19:15 /ICCP; E:1Wrghtwft HVACITemplate Bill Hollisl(Salem House).ep Calc=MJ8 Orlentalion=N Pagel Fldors 19A-Obscp: Carpeted floor over tight basement, No wall insul. No insul 21A -32c: Carpeted basement floor. No insulation, 32' wide vv• 11=1 - IC. k4 IC ngnwuse Heslgerlml 6.0.02 RSR40615 /1=-K EAWrlgMsoO HVAMTemplateleill Hollist(Salem House).n, CaIc=MJ8 Orientalbn=N 802 0.295 0.0 8.42 6755 1.55 1244 1479 0.020 0.0 1.52 2248 0.00 0 2008-Ap114 16:19:15 Page 2 Project Summary Entire House Hollist Constuction Project Information For: Dalling Residence Rexburg, ID 83440 Notes: Design Information Job: Date: Apr 14, 2008 By: Printout certified by ACCA to meet all requirements of Manual J 8th Ed. k& rye-, wngF>ttsoft RighlSufte Resdanlia16.0.02RSR40615 2008 -Apr -1416:19:15 E.- Wrlghlsofl 14VAC\Templat"ill Honig (Salem House).rrp Cale = MJ8 Orienlatlen = N Page l Weather: Idaho Falls, ID, US Winter Design Conditions Summer Design Conditions Outside db -6 'F Outside db 89 OF Inside db 70 'F Inside db 75 OF Design TO 76 'F Design TO 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 51916 Btuh Structure 23685 Btuh Ducts 0 cfm Ducts 0 Btuh Central vent (86 cfm) 6058 Btuh Central vent (86 cfm) 1116 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 57974 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 23313 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 433 Btuh Ducts 0 Btuh Heating Cooling Central vent (86 cfm) -1551 Btuh Area (ft') 3760 3760 Equipment latent load 0 Btuh Volume (ft') 21501 21501 Air changes/hour 0.28 0.15 Equipment total load 23313 Btuh Equiv. AVF (cfm) 100 54 Req. total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make AmStd Make AmStd Trade Freedom 90 Trade Allegiance 13 Model AUC100C948W Cond 2A7A3036A1 Coil 2TXCB048 AC3HCA Efficiency 92.1 AFUE Efficiency 13 SEER Heating Input 100000 Btuh Sensible cooling 25060 Btuh Heating output 94000 Stuh Latent cooling 10740 Btuh Temperature rise 79 OF Total cooling 35800 Btuh Actual air flow 1281 cfm Actual air flow 1281 cfm Air flow factor 0.025 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. k& rye-, wngF>ttsoft RighlSufte Resdanlia16.0.02RSR40615 2008 -Apr -1416:19:15 E.- Wrlghlsofl 14VAC\Templat"ill Honig (Salem House).rrp Cale = MJ8 Orienlatlen = N Page l AED Assessment rr Entire House Hollist Constuction Project Information For: Dating Residence Rexburg, ID 83440 Job: Date: Apr 14, 2008 By: Hourly Glazing Load Hour of Day /v Average i Aeoemn Maximum hourly glazing load exceeds average by 26.4%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh wnghtsoft Right-S.h.Residentia16.0A2RSR40615 2008-APr-1416:19:15 ,2/;,('r EAMighlsoft HVACITemplate\bill Hollist(Salem Houw).rrp Cae=MJ8 Orentafon=N Paget Design Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 70 75 Elevation: 4741 ft Design TD (°F) 76 14 Latitude: 44°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: Daily range (°F) - 34 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Hourly Glazing Load Hour of Day /v Average i Aeoemn Maximum hourly glazing load exceeds average by 26.4%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh wnghtsoft Right-S.h.Residentia16.0A2RSR40615 2008-APr-1416:19:15 ,2/;,('r EAMighlsoft HVACITemplate\bill Hollist(Salem Houw).rrp Cae=MJ8 Orentafon=N Paget Right Worksheet Job: Entire House Date: Apr 14, 2008 Hollist Constuction By: I Room name Entire House bed 1 2 Exposed wall 375.2 fl 30.0 ft 3 Ceiling height 9.0 8 d 9.0 8 heat/cool 4 Roomdimensions x 273.0 8 5 Room area 3760.0' 0 21308'1.0 Ty Construction U -value Or HTM Area Area number (BIuhBR°F) (Btuh/82) or perimeter (8) (Bttuuh) ore (8) (Bttuuh) Heat Cod Gross WPB Heat Cool Gross WP/S Heat Cool 6 Vy 12F-0sw 0.065 n 4.94 0.47 693 564 2786 268 0 0 0 0 iDc20w 0.570 n 43.32 18.61 94 0 4072 1750 0 0 0 0 L�_Gp 11D0 0.390 n 29.64 721 35 35 1037 253 0 0 0 0 15A114)ocw-10 0.103 n 3.65 0.48 459 359 1310 0 135 110 401 0 11 1D-c2ow 0.570 n 43.32 18.61 65 0 2816 1210 25 0 1083 465 11D0 0.390 n 29.64 7.21 35 35 1037 253 0 0 0 0 4y 12F-0sw 0.065 a 4.94 0.47 261 226 1114 107 0 0 0 0 �G IDc2ow 0.570 a 43.32 60.38 36 0 1538 2144 0 0 0 0 Vj/ 15All-Oocw-10 0.103 a 3.65 0.48 261 236 861 0 135 135 492 0 -G 1Dc2ow 0.570 a 43.32 60.38 25 0 1083 1510 0 0 0 0 W 12F-0sw 0.065 as 4.94 0.47 51 51 252 24 0 0 0 0 Vp 12F-0sw 0.065 s 4.94 0.47 621 492 2428 233 0 0 0 0 iD-c2ow, 0.570 s 43.32 33.17 109 0 4700 3599 0 0 0 0 11 ----GD 11 DO 0.390 s 29.64 7.21 21 21 622 152 0 0 0 0 W 15A11-Oocw-10 0.103 s 3.65 0.48 459 459 1674 0 0 0 0 0 W 12F-0sw 0.065 sw 4.94 0.47 51 51 252 24 0 0 0 0 Vy 12F 0.065 w 4.94 0.47 261 221 1092 105 0 0 0 0 _G 1D -clow 0.570 w 43.32 60.38 40 0 1733 2415 0 0 0 0 W 15A11-Oocw-10 0.103 w 3.65 0.48 261 261 952 0 0 0 0 0 C 16B-38ad 0.026 - 1.98 1.09 2281 2281 4507 2491 0 0 0 0 F 19A-0bscp 0.295 - 8.42 1.55 802 85 6755 1244 0 0 0 0 F 21A -32c 0.020 1.52 0.00 1479 160 2248 0 213 30 324 0 6 c) AED excursion 0 -fi3 Envelope loss/gain 44869 17780 2301 403 12 a) Infiltration 7047 695 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 7 1610 1 Appliances Q 1200 3 3600 0 230 0 Less external load 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 57916 23685 4 2305 0 833 15 Dud loads I 0% 0% 0 0 0% 0% 0 0 Total room load 51916 23685 2305 633 Air required (dm) 1281 1281 1 57 34 Printout Certified by ACCA to meet all requirements of Manual J 8th Ed wR'1g�'1t50{C RlghtSURe Resitlentlal6.0.02 RSR40615 200&Apr-1416:19:15 AC A E:1Wrlghtwft HVACITemplate%Bill Hollist(Salem House).rip Cat=W8 Orientation =N Pagel Right Worksheet Job: Entire House Date: Apr 14, 2008 Hollist Constuction By: 1 Room name Gst. 2 bed 2 2 Exposed wall 0.0 fl 29.0 8 3 Ceiling height 9.0 0 heaticool 9.0 it heaticool 4 Room dimensions 2.0 x 4.0 1t 1.0 x 190.0 it 5 Room area 8.0 fl' 1900. 82 Ty Construction U -value Or HTM Area number (Btuhiftz. F) (Btuh/R') or perimeter (9) (Bttuuh) ore perimeter (8) (Bttuuh) Heat Cool Gross TNIPIS Heat Cool Gross N!P(S Heat Cool 6 VP12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 1D-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 1�-GD 11 DO 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 15A11.Ooow-10 0.103 n 3.65 OA8 0 0 0 0 0 0 0 0 11 1Dc2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 1iD0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 12F -Ow 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 15A1140om-10 0.103 a 3.65 0.48 0 0 0 0 126 101 368 0 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 25 0 1083 1510 W 12F-0sw 0.065 m 4.94 0.47 0 0 0 0 0 0 0 0 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 Tj12F-0sw 11)-c2ow 0.570 s 43.32 33.17 0 0 0 0 0 0 0 0 11130 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 W 1SAii-Oom-10 0.103 s 3.65 0.48 0 0 0 0 135 135 492 0 W 12F -Om 0.065 sw 4.94 0.47 0 0 0 0 0 0 0 0 Vy Y_G 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 1Dc20W 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 W 15A11-0ocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 - 1.98 1.09 0 0 0 0 0 0 0 0 F 19A-Obscp 0.295 - 8.42 1.55 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 8 0 12 0 190 29 289 0 6 c)AED excursion 0 55 Envelope lossigain 12 0 2233 1565 12 a) Infiltration 0 0 p b) Room ventilation 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances Q 1200 0 0 0 0 Less external load 0 g 0 0 Less transfer 0 0 0 0 Redistribution n -12 0 368 0 14 Subtotal 0 0 2601 1795 15 Dud loads 0% 0% 0 0 0% 0% 0 0 Total room load 0 0 2601 1785 Air required (dm) 0 0 64 97 Printout certified by ACCA to meet all requirements of Manual J 8th Ed {� wY�4JFlLSOR RlghtSude ResMential S.0.02RSR40615 2008 -Apr -1418:19:15 �K;C,A E:1Wrightso9 HVAC\TemplatsiBill Hollist(Salem House).up Cat=MJB Orientatbn=N Page Right- Worksheet �. I ,:IT Entire House Hollist Constuction Job: Date: Apr 14, 2008 By: 1 Room name great room dining 2 Exposed wall 27.0 it 30.0 it 3 Ceiling height 9.0 0 heathool 9.0 it heagcool 4 Room dimensions 27.0 x 15,0 ft 15.0 x 15.0 it 5 Room area 405.0 8' 225.0 W Ty Construction IT value Or HTM Area (0°) Load Atea (fl') Load number I (BtuNfP--°F) (BtuNfl') or petlmeter (fl) (Bluh) ar perimeter (ft) (Bluh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 135 100 494 47 i Dc2ow, 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 1100 0.390 n 29.64 7.21 0 0 0 0 35 35 1037 253 1� 15A11-0ocw-10 0.103 n 3.65 0.48 243 183 668 0 0 0 0 0 11 I -G 1D -clow 0.570 n 43.32 18.61 25 0 1083 465 0 0 0 0 �LZ 11 DO 0.390 n 29.64 7.21 35 35 1037 253 0 0 0 0 W 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 135 110 543 52 VLG 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 25 0 1083 1510 t 15A11-0ocw-10 0.103 a 365 0.48 0 0 0 0 0 0 0 0 -G 1Dc2ow 0.570 a 43.32 6(L38 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 tj12F-0sw iD-c2ow 0.570 s 43.32 33.17 0 0 0 0 0 0 0 0 11 DO 0.390 a 29.64 7.21 0 0 0 0 0 0 0 0 W 15Ai 1-0ocw-10 0.103 s 3.65 0.48 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 sw 4.94 0.47 0 0 0 0 0 0 0 0 t 121F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 -G ID-c2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 W 15A11-0ocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 1613-38ad 0.026 - 1.98 1.09 0 0 0 0 225 225 445 246 F 19A-Obscp 0.295 - 842 1.55 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 405 27 616 0 0 0 0 0 6 c) AED excursion 85 13 Envelope loss/gain 3404 633 3602 2121 12 a) Infiltration 0 0 b) Room ventilation 98 9 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 Appliances @ 1200 O 00 0 0 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 0 0 14 Subtotal Duct loads 3473 863 4584 2218 15 0% 0% 0 0 0% 0% 0 0 Total room load Air required ad 3473 863 4584 2218 86 47 113 120 Printout certified by ACCA to meet all requirements of Manual J 8th Ed +. Wrrg1-tIC50{t Right-Sude Resgentia16.0.02R5R40615 2008116:19:15 .�;Gl E9Wrghi HVACVemplatelBill Hollist(Salem HouseTop Calc=MJB Orientation=N Page Right Worksheet Job: Entire House Date: Apr 14, 2008 Hollist Constuction By: 1 Room name family mom kitchen 2 Exposed wall 24.0 fl 32.0 fl 3 Calling height 9.0 fl heaVcool 9.0 fl heaVcwI 4 Room dimensions 1.0 x 374.0 fl 18.0 x 14.0 fl 5 Room area 374.0 fl2 252.0 fe Ty Construction U -value Or HTM Area (fl') Load Area number (BfuWfl'--"F) (BtuWli� or perimeter (fl) (Btuh) or perimeter (fl) (Bttuuh) Heat Cool Gross WP/S Heat Cool Gross WPlS Heat Cool 6 12F-0sw 0.065 n 4.94 0.47 216 166 820 79 0 0 0 0 11)c2ow 0.570 n 43.32 18.61 50 0 2166 931 0 0 0 0 11DO 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 15A71-0ocw-10 0.103 n 3.65 0.48 0 0 0 0 0 0 0 0 11 1Dc2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11 DO 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 ly 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 126 116 571 55 t -G 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 11 0 455 634 15All-Oom-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 1Dc2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 w 12F-0sw 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 162 152 748 72 �t�--DDD iD-c2ow 0.570 s 43.32 33.17 0 0 0 0 11 0 455 348 11 DO 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 w 15All-Oom-10 0.103 s 3.65 0.48 0 0 0 0 0 0 0 0 w 12F-0sw 0.085 sw 4.94 0.47 0 0 0 0 0 0 0 0 Vy 12F-Osw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 t1' 1D -clow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 w 15A11-Oocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 1813-38ad 0.026 1.98 1.09 374 374 739 408 252 252 496 275 F 19A-Obscp 0.295 - 8.42 1.55 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -134 -350 Envelope losslgain 3725 1283 2727 1035 12 a) Infiltration 786 78 1047 103 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 2 2400 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 124 47 7 14 Subtotal 4635 1407 3714 88 3545 15 Duct loads 0% 0% 0 0 0% 0%1 0 0 Total room load 4635 1407 3788 3545 Air requlretl (dm) 114 76 93 192 Printout certified by ACCA to meet all requirements of Manual J 8th Ed wnJF' Vt C ft Right -Suite ResidentIaI6.0.02RSR408t5 2008 -Apr -1416:19:15 ACCGP, E:1Wrghtsofl HVACITempleteUlif Hollist(Salem House).rm Cale =MJ8 Orientation = N Page y Right-., Worksheet Entire House Hollist Constuction Job: Date: Apr 14, 2008 By: 1 Room name living clst. 1 2 Exposed wall 15.6 If 0.0 fl 3 Ceiling height 9.0 it heat/cool 9.0 it heat(cool 4 Room dimensions 1.0 x 1640 It 20 x 4.0 0 5 Room area 164.0 W 8.0 W Ty Construction U -value Or HTM Area (ft') Load Area fl Load number (BIUNfl? °F) (Btuh/fl') or perimeter (fl) (Bluh) or perimeter (fl) (Bluh) Heat Cool Gross NIPIS Heat Cool Gross N/PIS Heat Cool 6VLG12F-0sw 0,065 n 4.94 0.47 0 0 0 0 0 0 0 0 1D-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11 DO 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 15A17-Oom-10 0.103 n 3.65 0.48 0 0 0 0 0 0 0 0 11 113-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11 DO 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 y! 1217-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 Y -G 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 15A11-Oocw-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 se 4.94 0.47 25 25 126 12 0 0 0 0 VLi12F-0sw 0.065 s 4.94 0.47 90 60 296 28 0 0 0 0 1D-c2ow 0.570 s 43.32 33.17 30 0 1300 995 0 0 0 0 11 DO 0.390 s 29.64 7211 0 0 0 0 0 0 0 0 w 15A71-Oocw-10 0.103 s 3.65 0.48 0 0 0 0 0 0 0 0 w 12F-0sw 0,065 sw 4.94 0.47 25 25 126 12 0 0 0 0 ly 12F-0sw 0.065 w 4.94 (.47 0 0 0 0 0 0 0 0 -G 1 D-c2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 W 15A11-Oom 10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 - 1.98 1.09 164 164 324 179 8 8 16 9 F 19A-0bsep 0.295 - 8.42 1.55 24 2 202 37 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 172 1 Envelope loss/gain 2374 1436 16 8 12 a) Infiltration 512 51 0 0 b) Room ventilation 0 0 0 0 13 Internal gains'. Occupants Q 230 0 0 0 Appliances Q 1200 0 0 0 0 0 Less external load 0 0 0 Less transfer 0 0 0 0 0 Redistribution 67 29 6 8 14 Subtotal 2953 1516 0 0 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 2953 151fi 0 0 Air required (cm) 73 82 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed wY1Gj F-ttt56ft RightSude Resitlentia16.0.02RSR40615 2008 -Apr -1416:19:15 ,K:CP- E:%Wrightsoft HVAMTemplaUABill Hollist(Salem House).rM Cale =MJB Orientation = N Pages Right Worksheet Joh: Entire House Dale: Apr 14, 2008 t Hollist Constuction By: 1 Room name stairs 1 entry 2 Exposed wall 0.0 It 7.0 8 3 Ceiling height 9.0 It hea0cool 9.0 It heal/cool 4 Room dimensions 12.0 x 4.0 If 7.0 x 8.0 ft 5 Room area 48.0 ft' 56.0 ft' Ty Construction U -value Or HTM Area (ft') Load Area (111 Load number (Btu1VWF) (Btuhlff) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross WP/S Heat Cool Gross WPB Heat Cool 6 121F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 113-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11D0 0.390 n 29.64 721 0 0 0 0 0 0 0 0 15A11-Oo AO 0.103 n 3.65 0.48 0 0 0 0 0 0 0 0 11 ID-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 Yy 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 Y1' ID-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 15A11-Oom-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 1D-c2cw 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 W 12F -Om 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 Vl/ 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 63 28 138 13 II 1D-c2ow 0.570 s 43.32 33.17 0 0 0 0 14 0 606 464 11D0 0.390 s 29.64 7.21 0 0 0 0 21 21 622 152 ---GD W 15A11-0ocw-10 0.103 s 3.65 0.48 0 0 0 0 0 0 0 0 w 12F -Ow 0.065 sw 4.94 0.47 0 0 0 0 0 0 0 0 12F-0sw 0.065 w 4.94 OA7 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 W 15A71 -Dom -10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 168-38ad 0.026 - 1.98 1.09 48 48 95 52 56 56 111 fit F 19A-0bscp 0.295 - 8.42 1.55 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -5 71 Envelope loss/gain 95 48 1478 762 12 a Infiltration 0 0 229 23 b Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances Q 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 95 -08 73 21 14 Subtotal 0 0 780 805 15 Duct loads 0% 0%1 01 of 0% 0% 01 0 Total room load 00 1780 805 Air required (cfm) 0 0 44 44 Printout Certified by ACCA to meet all requirements of Manual J 8th Ed w Pig Fttsoft RightSufte R"Idenflale.0.02RSR40615 2008 -Apr -1416:19:15 "k E:1Wrighlso6 WAMTemplatelBill HOW (Salem House).rrp Calc =We Orientation = N Page Right Worksheet Job: Entire House Date: Apr 14, 2008 Hollist Constuction By: 1 Room name mars bath bath 2 2 Exposed wall 12.0 ft 5.0 ft 3 Ceiling height 9.0 0 heat/cool 9.0 ft heaVcool 4 Roam dimensions 12.0 x 17.0 ft 5.0 x 8.0 ft 5 Room area 204.0 ft' 40.0 t' Ty Construction U -value Or HTM Area (ft') Load Area (ft') Load number (BIUMftMF) (Bluh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh Heat Cool Gross WPB Heal Cool Gross WP/S Heat Cool 6 1[:t 121F-0sw 0.065 n 4.94 0.47 108 94 464 45 0 0 0 0 11)-c2ow 0.570 n 43.32 18.61 14 0 606 261 0 0 0 0 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 15A1 1 -0ocw-1 0 0.103 n 3.65 0.48 0 0 0 0 0 0 0 0 11 iD-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 4y 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 L -G MD tow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 t_6 15A71-Oocw-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 1Dc2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 w 12F-0sw 0.065 as 4.94 0.47 0 0 0 0 0 0 0 0 ly 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 45 41 203 19 IL -GD 1 D-c2ow 0.570 s 43.32 33.17 0 0 0 0 4 0 173 133 11D0 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 W 15A11-Oocw-10 0.103 s 3.65 0.48 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 sw 4.94 0.47 0 0 0 0 0 0 0 0 y/ 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 Y_G 1D-c2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 W 15A71-0ocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 1613-38ad 0.026 - 1.98 1.09 204 204 403 223 40 40 79 44 F 19A-0bscp 0.295 - 8.42 1.55 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -51 20 Envelope losslgaln 1474 477 455 215 12 a) Infiltration 393 39 164 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances aQ 1200 0 0 0 0 Less external load 0 g 0 0 Less transfer 0 0 0 0 Redistribution 126 36 52 15 14 Subtotal 1992 551 671 246 15 Duct loads 0% 0%1 0 0 0% 0% 01 0 Total room load1992 551 671 248 Air required (dm) 49 30 17 13 Printout certified by ACCA to meet all requirements of Manual J 8th Ed wr-egF-tlt5oft RightSu4e Residenda16.0.02RSR40615 2008 -Apr -1415:19:15 AC^G`A E. Wrightsoft HVACITemplate1Bl11 Hollist(Salem House).rrp Calc =MJB Orientatbn=N Pagel Right JVorksheet Job: Entire House Date: Apr 14, 2008 Hollist Constuction By: 1 Room name den laundry 2 Exposed wall 15.6 fl 6.0 fl 3 Ceiling height 9.0 0 heal/coal 9.0 A heat/cool 4 Roomdimensions 1.0 x 136.0 it 6.0 x 8.0 fl 5 Room area 136.0 W 48.0 fl' Ty Construction U -value Or HTM Area (fl') Lead Area (fl') Load number (Btuwnk,F) (BtuIVR j or perimeter (fl) (Btuh) or perimeter (fl) (Btuh) Heat Cod Gross N/P!S Heat Cool Gross N/P!S Heat Cool 6 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 1D-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 15AMO-0 -10 0.103 n 3.65 0.48 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 t 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 -G 1Dc2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 15A11-0ocw-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 7 D-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 se 4.94 0.47 25 25 126 12 0 0 0 0 12F-0sw 0.065 s 4.94 0.47 90 60 296 28 54 54 267 26 1Dc2ow 0.570 s 43.32 33.17 30 0 1300 995 0 0 0 0 11D0 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 W 15Ai1-Oocw-10 0.103 s 3.65 0.48 0 0 0 0 0 0 0 0 W 12F -Om 0.065 sw 4.94 0.47 25 25 126 12 0 0 0 0 t-0 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 1Dc2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 w 15A11-0ocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 1.98 1.09 136 136 269 149 48 48 95 52 F 19A-0bscp 0.295 - 8.42 1.55 80 9 674 124 48 6 404 74 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 146 -123 Envelope loss(galn 2790 1467 766 29 12 a) Infiltration 512 51 196 19 6 Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 1 230 0 0 Appliances@ 1200 0 0 1 1200 Less external load 0 0 0 0 Less transfer 6 0 0 0 Redistribution 48 42 63 18 14 Subtotal 3449 1789 1025 1266 15 Duct loads 0% 0% 0 0 0°0 0% 0 0 Total room load 3449 1789 1025 1266 Air required (dm) 85 97 25 69 to meet all iiC&�n/r�gi"1t5oft RlghtSude Residential6.0.02RSR40615 1` E:1WrigMeo6 HVAMTempletelBill Hollist(Salem Houw).fM Cak=Mill Orientation=N 8th Ed. 200&Apr-1416:19:15 Page a Right Worksheet Job: Entire House Date: Apr 14, 2008 Hollist Constuction By; 1 Room name hall bed 3 2 Exposed wall 0.0 ft 25.0 ft 3 Ceiling height 9.0 It heaeocol 9.0 ft heatIcool 4 Room dimensions 34.0 x 4.0 ft 1.0 x 148.0 ft 5 Room area 136.0 ft' 148.0 ft' Ty Construction U -value Or HTM Area(ft') a Lead number (BtuWW--°F) (BtuKW) or perimeter er (ft) (Bttuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WWS Heat Cool 6% 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 1D-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 L�_.Gp 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 15A114Oocw-10 0.103 n 3.65 0.48 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 ly Y 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 1Dr20w 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 -G 15A11 -Dom -10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 1Dc2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 w 12F -0&w 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 117 97 479 46 1D-c2ow 0.570 s 43.32 33.17 0 0 0 0 20 0 866 663 1100 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 w 15Aii-0ocw-10 0.103 s 3.65 OAS 0 0 0 0 0 0 0 0 w 12F-0sw 0.065 sw 4.94 0.47 0 0 0 0 0 0 0 0 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 108 88 435 42 1Dc2ow 0.570 w 43.32 60.38 0 0 0 0 20 0 866 1208 w 15A11-Oocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 - 1.98 1.09 136 136 269 149 148 148 292 162 F 19A-0bscp 0.295 - 8.42 1.55 60 0 505 93 148 25 1247 230 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -22 116 Envelope Iossrgam 774 220 4186 2466 12 aInfiftmtion 0 0 818 81 b Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances Q 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -774 -220 63 18 14 Subtotal 0 0 5067 2794 15 Duct loads 070 0% 01 0 0% 0% 0 0 Total room load 0 0 5067 2794 Air required term) I 1 0 0 1251 151 Printout K/r19 �'1Z50' RlghtSude ResUentla18.0.02 RSR40815 AC ESWrlghtsoft HVACITemplateMill Hollist(Salem Houx).rM Cab=MJ8 Orientation=N of 200&Apr-1416:19:15 Page 9 Right-. Worksheet Jobi Entire House Date: Apr 14, 2008 By: Hollist Constuction 1 Room name Office mas clst. 2 Exposed wall 11.0 ft 14.0 ft 3 Ceiling height 9.0 ft heal) ool 9.0 ft heaVcool 4 Room dimensions 8.0 x 11.0 ft 8.0 x 6.0 ft 5 Room area 88.0 ft' 48.0 ft' Ty Construction Jl value Or HTM (ft') Areaft') Load Area ( Load number Btutdftk*F ( ) (BtuNfN) or pedmeter (fl) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 0.065 n 4.94 0.47 0 a 0 0 72 72 356 34 VP12F-0sw iOc2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11D0 0.390 n 29.64 721 0 0 0 0 0 0 0 0 VLZ Mil.Oocw-10 0.103 n 3.65 0.48 0 0 0 0 0 0 0 0 11 ID-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11 DO 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 Vy 12F-0sw, 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 I -G ID -clow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 t 15A11-0ocw-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 -C 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 W 121F-0sw 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 1D-c2ow 0.570 s 43.32 33.17 0 0 0 0 0 0 0 0 "Ll121F-0sw 11DO 0.390 a 29.64 7.21 0 0 0 0 0 0 0 0 W 15A71-Oom-10 0.103 s 3.65 0.48 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 sw 4.94 OA7 0 0 0 0 0 0 0 0 yl 12F-0sw 0.065 w 4.94 0.47 99 79 390 37 54 54 267 26 LC iD,c2ow 0.570 w 43.32 60.38 20 0 886 1208 0 0 0 0 W 15A11-0ocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 1613-389d 0.026 1.98 1.09 88 88 174 96 48 48 95 52 F 19A-0bscp 0.295 - 8.42 1.55 68 11 741 137 48 14 404 74 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 461 -21 Envelope loss/gain 2172 1939 1122 166 12 a) Infiltration 360 36 458 45 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances Q 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 903 121-1580 -211 14 Subtotal 3434 2095 0 0 15 Dud loads 0% 0% 0 0 0% 0% 0 0 Total room load 3434 2095 0 0 Air required (cm) 85 113 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrr JFltsoft RightSufe Residenfa16.0.02RS1140615 2008 -Apr -1418:19:15 .Y k E:1Wrightsoft WACITemplatelBill HOW (Salem Houss).m, Cale =MJ8 Orleranuen=N Peg. 10 MAI Righter . /orksheet Entire House Hollist Constuction Job: Date: Apr 14, 2008 By: 1 Room name area bed stairs 2 Exposed wall ISO ft 0.0 ft 3 Ceiling height 9.0 ft hea9ccol 9.0 ft heaVcool 4 Room dimensions 18.0 x 17.0 ft 16.0 x 4.0 0 5 Room area 306.0 ft' 64.0 ft' Ty Construction U -value Or HTM Area (ft') Load Area (0') Load number (BtulJft2--°F) (BtuMt') or perimeter (ft) (Btuh) or perimeter (e) (etuh) Heat Cool Gross NARIS Heat Cool Gross N/P/S Heat Cool 6LD 12F-0sw 0.065 n 4.94 0.47 162 132 652 63 0 0 0 0 1D-c2ow 0.570 in 43.32 18.61 30 0 1300 558 0 0 0 0 11 DO 0.390 in 29.64 7.21 0 0 0 0 0 0 0 0 15A11-0 ocw-10 0.103 n 3.65 0.48 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 in 43.32 18.61 0 0 0 0 0 0 0 0 11 D0 0.390 in 29,64 7.21 0 0 0 0 0 0 0 0 W, 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 L -G 113r2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 15A11-0ocw-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 113c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 VJ 12F Om 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 �L(D- 1D-c2ow (.570 s 43.32 33.17 0 0 0 0 0 0 0 0 11 DO 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 W 15A11 010.103 s 3.65 0.48 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 sw 4.94 0.47 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 T -G 1D-c2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 W 15A11-0ocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 1613-38ad 0.026 - 1.98 1.09 306 306 605 334 0 0 0 0 F 19A-Obscp 0 295 - 8.42 1.55 306 18 2577 475 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 64 0 97 0 6 c)AED excursion 175 0 Envelope loss/gain 5134 1255 97 0 12 a) Infiltration 589 58 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 Appliances @ 1200 0 0 0 g 0 Less external load 0 0 Less transfer 0 0 0 0 Redistribution 834 135 0 618 0 0 14 Subtotal 6557 1908 715 0 15 Duct loads 0% 0% 0 0 0% o% 0 0 Total room load 6557 1908 715 0 Air required (dm) 162 103 18 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed �_ W rig F-,CSOTi Right-SUite Resitlential6.0.02 RSR40615 200&Apr-1416:19:15 .f XIP. E:1Wryhlsoft HVACITemplate%Bill Hollist(Salem House).rip Cab=MJB Orientatbn=N Page 11 Righty Worksheet „I 1 Entire House Hollist Constuction Job: Date: Apr 14, 2008 By: 1 Room name hall 2 pantry 2 Exposed wall 0.0 0 8.0 0 3 Ceiling height 9.0 0 heml000l 9.0 O heaV000l 4 Room dimensions 10 x 36,0 0 8.0 x 10.0 8 5 Room area 360 ft' 80,0 W Ty Construction U -value Or HTM Area (0') Load Area (0') Load number (BtuNB'-°F) (BlulVO') or perimeter (8) (BWh) or perimeter (0) (BWh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W, 12F-Osw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 �L--0G 1Dc2ow, 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11130 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 15A11 OOM-10 0.103 In 3.65 0.48 0 0 0 0 0 0 0 0 11 1D-c2ow 0570 n 43.32 18.61 0 0 0 0 0 0 0 0 11 DO (I n 29.64 7.21 0 0 0 0 0 0 0 0 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 iD-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 Vj/ 15A71-OOCN-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 t -C 1Dc2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 W 121F-0sw 0.065 se 494 0.47 0 0 0 0 0 0 0 0 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 1D-c2ow 0.570 s 43.32 33.17 0 0 0 0 0 0 0 0 11 DO 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 W 15A11-010 0.103 s 3.65 0.48 0 0 0 0 72 72 263 0 W 12F-Osw 0.065 sw 4.94 0.47 0 0 0 0 0 0 0 0 t 12F-Osw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 -C 1D-c2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 W 15Ai1-Oocw-10 0.103 w 3.65 0.48 0 0 0 0 0 0 0 0 C 1613-38ad 0.026 - 1.98 1.09 0 0 0 0 0 0 0 0 F 191 0295 - 8.42 1.55 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 36 0 55 0 80 8 122 0 6 c) AED excursion 0 0 Envelope losstgain 55 0 384 0 12 a) Infiltration 00 0 0 b) Roomventilation 0 0 0 0 13 Internal gains'. Occupants @ 230 0 0 0 Appliances @ 1200 0 0 0 0 0 Less external load 0 0 0 Less transfer 0 0 0 0 0 Redistribution 113 0 -384 0 14 Subtotal 168 0 0 0 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load ad 168 0 O 0 Air required 4 0 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed +_ v�/rrgf'itSOft Right-Sufte Residential6.0.02RSR40615 2008 -Apr -1416:19:15 lees:[ N E:1Wrightsoft HVACUemplate\Bill Hollist (Salem House).rrp Cab= Mi Orientation = N Page 12 Right-,) Worksheet Job. Entire House Date: Apr 14, 2008 Hollist Constuction By: I Room name bath 1 utlliry 2 Exposed wall 16.0 It 24.0 fl 3 Ceiling height 9.0 8 hea0cool 9.0 8 heaticool 4 Room dimensions 6.0 x 10.0 8 90 x 15.0 9 5 Room area 60.0 W 135.0 92 Ty Construction U -value Or HTM Area (112) Load Area (82) Load number I (Btuh/82-°F) (Btuhltt2) or perimeter (8) (Btuh) or perimeter (9) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WPB Heal Cool 6 yl 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 iDc2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 L�_Gp 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 'Ejo15A11-0ocw-10 0.103 n 3.65 0.48 0 0 0 0 81 66 241 0 11 1Dr20w 0.570 n 43.32 18.61 0 0 0 0 15 0 650 279 11 DO 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 ly 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 Y -C 1Dt2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 t15A11-0ocw-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 -.0 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 Lj iD-c2ow 0.570 s 43.32 33.17 0 0 0 0 0 0 0 0 11D0 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 W 15A11-Oocw-10 0.103 s 3.65 g.48 54 54 197 0 0 0 0 0 W 12F-0sw 0.065 sw 4.94 0.47 0 0 0 0 0 0 0 0 yl Y_G 12F-0sw 0.005 w 4.94 0.47 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 W 15All-0om-10 0.103 w 3.65 0.48 90 90 328 0 135 135 492 0 C 16B-38ad 0.026 1.98 1.09 0 0 0 0 0 0 0 0 F 19A-0bscp 0.295 - BA2 1.55 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 60 16 91 0 135 24 205 0 6 c) AED excursion 0 -25 Envelope loss/gain 617 0 1588 254 12 e) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 436 0 78 0 14 Subtotal1053 0 1666 254 15 Dud loads 0% 0% 0 01 0% 0%1 0 0 Total room load 1053 0 1666 254 Air required (dm) 28 0 41 14 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. M�w rlg!'t1C5ofC RlghlSURe Residen0al6.0.02 RSR40615 2008 -Apr -14 16:19:15 A E.Wrghlso6 HVAC\TemplaWBill Hollist(Salem House).rrp Calc =MJB Orientation =N Page 13 Right -i Worksheet Job: Entire House Date : Apr 14, 2008 By: Hollist Constuction 1 Room name hall 1 storage/mech 2 Exposed wall 4.0 fl 22.0 0 3 Ceiling height 9.0 fl heat/cool 9.0 0 heaVcool 4 Room dimensions 17.0 x 4.0 0 22.0 x 10.0 It 5 Room area 68.0 0' 220.0 0' Ty Construction U -value Or HTM Area (0') Load Area M Load number (Btuh4R°F) (BtutVO') or perimeter (6) (Btuh) or perimeter (0) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6yl 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 iDc2ow 0.670 n 43.32 18.61 0 0 0 0 0 0 0 0 I�-GD 1100 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 vLt 15A11-0ocw-10 0.103 n 3.65 BAB 0 0 0 0 0 0 0 0 11 ID-c2ow 0.570 n 43.32 18.61 0 0 0 0 0 0 0 0 11D0 0.390 n 29.64 7.21 0 0 0 0 0 0 0 0 t 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 -C 1D-c2ow 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 Vj/ 15A71-Oom-10 0.103 a 3.65 0.48 0 0 0 0 0 0 0 0 -G iDr20w 0.570 a 43.32 60.38 0 0 0 0 0 0 0 0 w 12F -Om 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 try 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 L�(D- ID-c2ow 0.570 s 43.32 33.17 0 0 0 0 0 0 0 0 11 DO 0.390 s 29.64 7.21 0 0 0 0 0 0 0 0 W 15A11-0ocw-10 0.103 s 3.65 0.48 0 0 0 0 198 198 722 0 w 12F-0sw 0.065 sw 4.94 OA7 0 0 0 0 0 0 0 0 t 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 43.32 60.38 0 0 0 0 0 0 0 0 w 15A11 -Gam -10 0.103 w 3.65 GAB 36 36 131 0 0 0 0 0 C 168-38ad 0.026 - 1.98 1.09 0 0 0 0 0 0 0 0 F 19A-0bscp 0.295 - 8.42 1.55 0 0 0 0 0 0 0 0 F 21A -32c 0.020 1.52 0.00 68 4 103 0 220 22 334 0 6 c)AED excursion 0 0 Envelope loss/gain 235 0 1057 0 12 a) Infifiration 0 0 0 0 b) Roomventilation 0 0 0 0 13 Internet gains: Occupants Q 230 0 0 0 0 Appliances Q 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -235 0 -1057 0 14 Subtotal 0 0 0 0 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 0 00 0 Air required (dm) 0 0 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnJF-Itsof(t MghtSuite Rwidendal6.0.02RSR40615 200&Apr-1416:19:15 AC A E1Wrgh1 HVAMTemplete0it Hollkd(Salem Houw).np Cato =MJ6 Orientation =N Page 14 Level 2 Job M Performed by for: Dalling Residence Rexburg, ID 83440 Hollist Constuction Scale: 1:132 Page 1 Right -Suite Residential 6.0.02 RSR40615 2008 -Apr -14 16:20:21 :1Wrightsoft HVAC\Template\Bill Duct System Summary Entire House Hollist Constuction Project Information For: Dalling Residence Rexburg, ID 83440 Job: Date: Apr 14, 2008 6y: Supply Branch Detail Table Name Heating Cooling External static pressure 0.80 in H2O 0.80 in H2O Pressurelosses 0.34 in H2O 0.34 in H2O Available static pressure 0.46 in H2O 0.46 in H2O Supply / return available pressure 0.22/0.24 in H2O 0.22/0.24 in H2O Lowest friction rate 0.067 in/100ft 0.067 in/100ft Actual air flow 1281 cfm 1281 cfm Total effective length (TEL) h 1737 431 685 ft 0.071 Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) Rect Size (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk bed 1 h 2305 57 34 0.077 6 OX 0 VIFx 32.0 255.0 st3 bed c 1795 64 97 0.0801 6 OX0 VIFX 30.0 245.0 st3 great room h 1737 431 23 0.071 1 6 OX 0 VIFX 22.0 1 290.0 1 st3 � greatmom-A It 1737 431 23 1 0.0671 6 1 Ox 0 VIFX 34.0 1 295.0 1 st2A dining c 11091 571 60 1 0.0761 6 1 Ox 0 VIFx 40.0 1 250.0 1 st3A dining -A I c 11091 571 60 0.0731 6 j OXO VIFX 29.0 1 275.0 1 St3 family room I h 23181 571 38 0.0801 6 Ox 0 VIFx 32.0 1 245.0 1 st2 family mom -A I h 23181 571 38 1 0.071 1 6 OX 0 VIFX 21.0 1 290.0 1 St3 kitchan I c 35451 931 192 1 0.078 1 6 1 OXO I VIFX 35.0 1 250.0 1 st3A Wing I c 15161 731 82 0.0781 6 OXO VIFX 18.0 265.0 1 st2 entry I h 17801 441 44 0.079 6 I Ox 0 VIFX 24.0 I 255.0 st2 mas bath I h 19921 491 30 0.0721 6 1 Oxo VIFx 25.0 280.0 st2A bath 2I h 671 17 13 I 0.071 1 6 1 OXO VIFX 26.0 285.0 st2A den c 1789 85 97 0.0751 6 1 OXO VIFx 43.0 250.0 St2A laundry I c 12661 251 69 0.0701 6 1 OXO I VIFX 49.0 265.0 St2A bad 3 c 27941 125 I 151 I 0.069I 6 OXO VIFx 62.0 260.0 st2B Office c 2095 85 113 0.081 6 OX 0 I VIFX 53.0 I 220.0 st2C mas bad h 3278 81 52 1 0.0701 6 1 OXO I VIFX 1 62.0 1 255.0 1 St2A mas bed -A I h 3278 81 52 0.068 6 Ox 0 VIFx 50.0 275.0 WA ataint hang I h 715 h 1681 18 41 0 0 1 0.076 0.0781 6 6 1 Ox 0 I Ox 0 1 VIFx VIFX 1 10.0 17.0 1 280.0 265.0 (st3 1 st3 bath 1 1 h 10531 261 0 1 0.0731 61 OXO I VIFX 1 32.0 1 270.0 1 st2A utility I t h 16661 411 14 I 0.0731 6 I OXO I VIFx I 44.0 I 260.0 I st2A Name Trunk Type Htg (cfm) Cig (cfm) Design FR Veloc (fpm) Diam (in) Rect Duct Size (in) Duct Material Trunk st2 Peak AVF 832 777 0.067 832 12 8 x 18 ShtMetl st1 st3 Peak AVF 1 450 505 0.071 1 757 1 10 1 8 x 12 1 ShtMetl st1 st3A Peak AVF 1 150 252 0.076 1133 1 7 1 8 x 4 ShtMetl st3 st1 Peak AVF 1 1281 1 1281 1 0.067 1 961 1 18 1 8 x 24 ShtMetl I Ox 0 st2A Peak AVF 1 658 613 0.067 1 846 1 10 8 x 14 1 ShtMetl st2 st2B Peak AVF 1 210 1 265 0.069 1 1190 1 7 1 8 x 4 1 ShtMetl st2A i st2C Peak AVF I 85 I 113 1 0.081 1020 6 I 8 x 2 ShtMetl st26 Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Valor: (fpm) Diam (in) RectSize (in) Stud/Joist I Opening (in) Duct Matl Trunk rb3 I 0x0 151 1 140 356.0 0.067 1358 6 8x 2 Type ShMt rt3 I rb1 I 0x0 1 1171 58 201.0 0.119 I 372 61 14x3.25 1 10x5 SJSp rt2A Irb2 I 0x0 1 2231 3341 191.0 1 0.1251 5281 101 2-14x3.25 1 2-10x9 ISJSp Irt3 I I rb4 I Ox 0 1 1581 142 1 216.0 1 0.111 1 4991 61 140.25 1 10x5 I SJSp I rt3 I Irb5 I 0x0 1 2081 2581 246.0 1 0.0971 4081 91 2-140.25 1 2-10x9 ISJSp Irb3 I Irb6 I 0x0 1 2471 2171 266.0 1 0.0901 3901 91 2-140.25 1 2-10x9 ISJSp I I I rb7 I 0x0 1 681 971 201.0 1 0.1191 3071 6114x3.25 1 10x5 I SJSp I rt2A I rb8 I 0x0 I 1101 371 174.0 I 0.1371 3481 61 14x3.25 1 10x5 I SJSp I rt3 Return Trunk Detail Trunk Htg Cig Design Veloc Diam Rect Duct Duct Name Type (cfm) (cfm) FR (fpm) (in) Size (in) Material Trunk rt2A Peak AVF 186 155 0.119 418 6 8 x 8 ShtMetl rt1 rt3 1 Peak AVF 642 1 652 1 0.067 734 1 14 8 x 16 ShtMetl rt1 rt1 Peak AVF 827 807 0.067 1 745 1 16 1 8 x 20 ShtMetl rb3 Peak AVF I 454 I 474 0.090 I 711 1 12 1 8 x 12 ShtMetl