Loading...
HomeMy WebLinkAboutLIGHTING COMPLIANCE - 08-00169 - ECIPDA - Remodel2006 IECC Report Date: 03/14/08 Data filename: C:\Documents and Settings\Sara Azary\Desktop10825-COMPCHECK.cck Section 1: Project Information Project Title: Entrepreneurial Center Renovation at EDIPDA Construction Site: Owner/Agent: Rexburg, ID Designer/Contractor: Bruce Bradley Bradley Engineering 382 Walnut st Idaho Falls, ID 83403 208-523-2862 bec@bradleyengineering.com Section 2: General Information Building Use Description by: Activity Type Project Type: Addition Activity Type(s) Floor Area Office 1700 Section 3: Requirements Checklist Interior Lighting: L] 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 1700 1696 YES Controls, Switching, and Wiring: Lj 2. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. ❑ 3. Master switch at entry to hotel/motel guest room. ❑ 4. Individual dwelling units separately metered. Lj 5. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant sensing device controls the area, The area is a corridor, storeroom, restroom, public lobby or sleeping unit. Areas that use less than 0.6 Watts/sq.ft. ❑ 6. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. F-1 7. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. Project Title: Entrepreneurial Center Renovation at EDIPDA Report date: 03/14/08 Data filename: C:\Documents and Settings\Sara Azary\Desktop\0825-COMPCHECK.cck Page 1 of 3 2006 IECC Report Date: Data filename: C:\Documents and Settings\Sara Azary\Desktop\0825-COMPCHECK.cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts Office 1700 Watts / ft2 (B x C) 1700 1 1700 Total Allowed Watts = 1700 Section 2: Proposed Lighting Power Calculation A Fixture ID : Description / Lamp /Wattage Per Lamp / Ballast B Lamps/ C # of D Fixture E (C X D) Fixture Fixtures Watt. Office (1700 sq,.ft. ) Linear Fluorescent 1: A: 2X4 recessed troffer / 48" T8 32W / Electronic 3 5 93 465 Linear Fluorescent 1 copy 1: Al: 2X4 recessed troffer, batt. pac / 48" T8 32W / 3 7 93 651 Electronic Linear Fluorescent 3: B: Surface 16" wide wrap / 48" T8 32W / Electronic 3 8 62 496 Linear Fluorescent 4: C: 2X4 recessed troffer / 48" T8 32W / Electronic 2 1 62 62 Incandescent 1: E: exittemergency light / Other 1 1 7 Exempt Exemption:Emergency Lighting (Automatic Control) Compact Fluorescent 1: D: ceiling mount/ Quad 2 -pin 22W / Electronic 1 1 22 22 Total Proposed Watts = 1696 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 1700 Total Proposed Watts = 1696 Project Compliance = 4.0 Project Title: Entrepreneurial Center Renovation at EDIPDA Report date: 03/14/08 Data filename: C:\Documents and Settings\Sara Azary\Desktop\0825-COMPCHECK.cck Page 3 of 3 8. Tandem wired one -lamp and '00%4�.-lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2006 IECC requirements in COMcheck Version 3.5.1 and to comply with the m datory requirements in the Requi-relnents Checklist. • /ami!% Name Title S nature Date Project Title: Entrepreneurial Center Renovation at EDIPDA� Report date: 03114/08 Data filename: C:\Documents and Settings\Sara Azary\Desktop10825-COMPCHECK.cck Page 2 of 3