HomeMy WebLinkAboutINSPECTION CHECKLIST - 08-00165 - 832 W 7th S - New SFRInspection CN Date: 03/31/08 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-49.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 2: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 3: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 4: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 5: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 6: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 7: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 8: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 9: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 10: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 11: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 12: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: 0800165 832 W 7th S -Beck Windows: ❑ Window 1: Vinyl Frame:Double Pane with Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2: Vinyl Frame:Double Pane with Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 3: Vinyl Frame:Double Pane with Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? Yes No Project Title: Mary Ann Beck - New Residence Report date: 03/31/08 Data nienarne: GnProgram RIGMUMAMPESM66k\M Beck 3-07.rck Page 3 of 5 . Comments: ❑ Window 4: Vinyl Frame:Double Pane with Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 5: Vinyl Frame:Double Pane with Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break?. Comments: ❑ Window 6: Vinyl Frame:Double Pane with Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? . Comments: Yes No Yes No ❑ Window 7: Vinyl Frame:Double Pane with Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 8: Vinyl Frame:Double Pane with Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? - Comments: Yes No Note: Up to 15 sq.ft. of glazed fenestration per dwelling is exempt from U -factor and SHGC requirements Doors: ❑ Door 1: Glass, U -factor: 0.350 Comments: ❑ Door 2: Glass, U -factor: 0.350 Comments: ❑ Door 3: Glass, U -factor: 0.350 Comments: ❑ Door 4: Solid, U -factor: 0.150 Comments: Floors: ❑ Floor 1: All -Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. ❑ Floor 2: All -Wood Joist/Truss:Over Outside Air, R-19.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 90 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are either 1) Type IC rated with enclosures sealed/gasketed against leaks to the ceiling, or 2) Type IC rated and ASTM E283 labeled, or 3) installed inside an air -tight assembly with a 0.5" clearance from combustible materials and a 3" clearance from insulation. Vapor Retarder: ❑ Vapor retarder is installed on the warm -in -winter side of all non -vented framed ceilings, walls, and floors; or it has been determined that moisture or its freezing will not damage the materials; or other approved means to avoid condensation are provided. Project Title: Mary Ann Beck - New Residence Report date: 03/31/08 Data filename: C:\Program Files\Check\REScheck\M Beck 3-07.rck Page 4 of 5 Comments: Materials Identification: Lj Materials and equipment are identified so that compliance can be determined. Fi Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R -values, glazing U -factors, and heating equipment efficiency are clearly marked on the building plans or specifications. F -I Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the insulation. Duct Insulation: ❑ Ducts in unconditioned spaces or outside the building are insulated to at least R-8. ❑ Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6. Duct Construction: ❑ Air handlers, filter boxes, and duct connections to flanges of air distribution system equipment or sheet metal fittings are sealed and mechanically fastened. ❑ All joints, seams, and connections are made substantially airtight with tapes, gasketing, mastics (adhesives) or other approved closure systems. Tapes and mastics are rated UL 181A or UL 181 B. ❑ Building framing cavities are not used as supply ducts. F-1 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. ❑ Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International Mechanical Code. Temperature Controls: ❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Heating and Cooling Equipment Sizing: F -I Additional requirements for equipment sizing are included by an inspection for compliance with the International Mechanical Code. Circulating Hot Water Systems: Lj Circulating hot water pipes are insulated to R-2. F-1 Circulating hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-2. Certificate: A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R -values; window U -factors; type and efficiency of space -conditioning and water heating equipment. NOTES TO FIELD: (Building Department Use Only) Project Title: Mary Ann Beck - New Residence Report date: 03/31/08 Data filename: C:\Program Files\Check\REScheck\M Beck 3-07.rck Page 5 of 5 C2006 IECCl-.nergy �J( Efficiency Certificate Ceiling / Roof 49.00 Wall 21.00 Floor/ Foundation 19.00 Ductwork (unconditioned spaces): rte. �� �;.�• Window 0.35 0.31 Door 0.35 0.35 Forced Hot Air Furnace 90 AFUE Water Heater: Name: Comments Date: