HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 08-00158 - 538 Henderson - New SFRf2lGenerated by REScheck-Web Software
Compliance Certificate
Report Date: 03/29/08
Energy Code:
2006 IECC
Location:
Rexburg, Idaho
Construction Type:
Single Family
Conditioned Floor Area:
4118 1`11:2
Glazing Area Percentage:
25%
Heating Degree Days:
8693
Climate Zone:
6
Construction Site: Owner/Agent:
08 001 5C
539 Henderson St -Mounts
Compliance: Passes on UA
Compliance: 34.6% Better Than Code Maximum UA: 456 Your UA: 298
Designer/Contractor:
Ceiling 1: Flat or Scissor Truss
2059
Wall 1: Wood Frame, 16in. o.c.
2059
Window 1: Vinyl Frame, 2 Pane w/ Low -E
403
SHGC: 0.40
Door 1: Solid
20
Door 2: Glass
120
SHGC: 0.40
Basement Wall 1: Solid Concrete or Masonry
2059
Wall height: 9.0'
Depth below grade: 7.0'
Insulation depth: 9.0'
0.0 40.0
23.0 0.0
23.0 0.0
49
83
0.060 24
0.350 7
0.350 42
93
Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in
REScheck-Web and to comply with the mandatory requirements listed in the REScheck inspection Checklist.
Name - Title
Signature
Date
Project Title: Report date: 03/29/08
Data filename: Page 1 of 3
Generated by REScheck-Web Software
Inspection Checklist
Date: 03/29/08
Ceilings:
❑ Ceiling 1: Flat or Scissor Truss, R-40.0 continuous insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1: Solid Concrete or Masonry, 9.0' ht / 7.0' bg / 9.0' insul, R-23.0 cavity insulation
Comments:
Windows:
❑ Window 1: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.060
For windows without labeled U -factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Note_ Up to 15 sq.ft. of glazed fenestration per dwelling is exempt from U -factor and SHGC requirements.
Doors:
❑ Door 1: Solid, U -factor: 0.350
Comments:
❑ Door 2: Glass, U -factor: 0.350
Comments:
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are either 1) Type IC rated with enclosures sealed/gasketed against leaks to the ceiling, or 2) Type 1C rated and ASTM
E283 labeled, or 3) installed inside an air -tight assembly with a 0.5" clearance from combustible materials and a 3" clearance from
insulation.
Vapor Retarder:
❑ Vapor retarder is installed on the warm -in -winter side of all non -vented framed ceilings, walls, and floors; or it has been determined that
moisture or its freezing will not damage the materials; or other approved means to avoid condensation are provided.
Comments:
Materials Identification:
❑ Materials and equipment are identified so that compliance can be determined.
Ll Manufacturer manuals for aft installed heating and cooling equipment and service water heating equipment have been provided.
tnsulabon R-vakies and glazing U -factors are dearly market on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instaK%ons, in substantial contact with the surface being insulated, and in a manner
that achieves the rated R -value without compressing the thsulation.
Duct Insulation:
Ll Ducts in unconditioned spaces or outside the building are insulated to at least R-8.
❑ Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6.
Duct Construction:
Project Title: Report date: 03/29/08
Data filename: Page 2 of 3
Cj Air handlers, filter boxes, and -'connections to flanges of air distribution system equipr"--.or sheet metal fittings are sealed and
mechanically fastened.
LJ 'MI joints, seams, and connections are made substantially airtight with tapes, gasketing, mastics (adhesives) or other approved closure
systems. Tapes and mastics are rated UL 181A or UL 181 B.
L1 Building framing cavities are not used as supply ducts.
Lj Automatic or gravity dampers are installed on all outdoor air intakes and exhausts.
U Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International
Mechanical Code.
Temperature Controls:
L) Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating andlor
cooling input to each zone or floor is provided.
Heating and Cooling Equipment Sizing:
Lj Additional requirements for equipment sizing are included by an inspection for compliance with the International Mechanical Code.
Circulating Hot Water Systems:
L1 Circulating hot water pipes are insulated to R-2.
Lj Circulating hot water systems include an automatic or accessible manual switch to tum off the circulating pump when the system is not
in use.
Heating and Cooling Piping Insulation:
Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-2.
Certificate:
L1 A permanent certificate is provided of or in the electrical distribution panel listing the predominant insulation R -values; window
U -factors; type and efficiency of space -conditioning and water heating equipment.
NOTES TO FIELD: (Building [department Use Only)
Project Title: Report date: 03/29/08
Data filename: Page 3 of 3
0 2006 IECCznergy
S( Efficiency Certificate
Ceiling 1 Roof 40.00
Wall 23.00
Floor / Foundation 23.00
Ductwork (unconditioned spaces):
Glass & Door Rating LI -Factor SHGC
Window 0.06 0.40
Door 0.35 0.40
Water Heater:___,_____
Name
Comments:
Date: