HomeMy WebLinkAboutSTRUCTURAL CALCULATIONS - 08-00153 - 236 Jill - New SFRStructural Calculations For: Kartchner Homes Plan #: Davenport C Location: Lot #2, Block #7, Henderson From: York Engineering Inc. 2329 W. Spring Hollow Road Morgan, Utah 84050(801) 876-3501 Design Criteria IRC 2006: Roof Load; Live Load (PSF) 50 Dead Load (PSF) 15 Floor Load; Live Load (PSF) 40 Dead Load (PSF) 10 19 March 2008 8 001-53 '36 Jill- artchner Seismic Zone: E �Fl Wind Speed: 90 mph (110 mph 3 second gust) < Exposure: C �7iIS SGNA7URE APPROVES STRUCNRAL ENgNEERING ONLY Material Properties & Assumptions Concrete PSI (&): 3000 (found.), 3000 (slabs), 4000 (susp. slabs) Concrete Reinforcement: ASTM A615 Grade 60 Site Conditions: Dry & Stable granular based, 1500 PSF Bearing Capacity, Granular Based Backfill (KH=35 pcf, KP=225), Slope not to exceed 20%, Minimum setback from slopes of 25` Dimensional Lumber: Hem or Doug Fir #2 & BTR Steel: ASTM A36 Use Simpson straps and tie downs, and meet nailing, reinforcement and other structural requirements as noted on the drawing and within the pages of this document. These structural calculations are based on conditions and assumptions listed above. If the conditions listed herein are not met or are different it shall be brought to the attention of the engineer. Roof Truss and beam system to be engineered by the supplier. This engineering assumes that the building site is dry and stable, a high water table or adverse soils such as plastic clays, fills etc. could cause future flooding, settlement, site instability, or other adverse conditions. Verification of and liability for the soil bearing pressure, site stability, and all other site conditions, including site engineering as required, is the responsibility of others. These calculations and engineering are for the new building structure only and do not provide any engineering analysis of or liability/warranty for the non-structural portions of the building, or the site itself. William York is the structural engineer only and does not assume the role of "Registered Design Professional" or "Engineer of Record"on this project. The purpose of these calculations and engineering is to help reduce structural damage and loss of life due to seismic activity and/or high wind conditions. The contractor shall verify all conditions, dimensions and structural details of the drawing. Multiple use of these calculations is not permitted. All exterior walls shall be sheathed with 7/16" APA rated structural wood panel. Block all horizontal edges 1 %2" nominal or wider. Sheathing shall extend continuous from floor to top plate and be nailed at least 4" O.C. along sill plate. Nails shall be placed not less than %2" from edge of panel and driven flush but shall not fracture the surface of the sheathing. Extend sheathing over gable end to wall joints & over rim joist between floors @6" O.C. Shear Wall Schedule tie Sheathing Nail Edge Field Anchor Bolts Typical 7/16" one side 8d 6" O.C. 10" O.C. %2" 32" O.C. SW -1 7/16" one side 8d 4" O.C. 10" O.C. %2" 32" O.C. Staples may be used in place of 8d nails at'/2 the spacing The following general requirements shall be followed during construction: 1. Contractor to verify all dimensions, spans, & conditions and notify engineer of any errors, omissions, or discrepancies prior to construction. 2. Use Simpson A35 ties each cantilevered joist to sill or top plate. 3. Use Simpson Hl or equiv. ties each end of each truss. 5. Foundation reinforcement as per plan. 6. Use 2: #4 bars continuous for all footings 2: # 4 bars each side of openings & 2 # 4 bars top & bottom extend 36" beyond opening 8. Use %2" x 10" J bolts 32" O.C. all foundation walls 9. If discrepancies are found, the more stringent specification shall be followed. 10. All multiple beams and headers to be nailed using 16d two rows 12" O.C. 11. Contractor shall assure that all materials are used per manufactures recommendations. 12. Site engineering and liability shall be provided by the owner/builder as required. 13. Connect beams & headers over 6 ft., to trimmers with appropriate connectors/hangers. 14. Contractor shall assure that footings are properly drained and that soil is dry and that footings rest on undisturbed native soil 30" below finished grade and that building horizontal clearance from footings to adjacent slopes be a minimum of 25 feet and that the intent of IRC section R403.1.7.2 is met. If set back requirements of R403.1.7.2 can not be met then contact engineer for further design requirements. 15. The contractor shall conform with all building codes and practices as per the 2006 IRC. 16. Use balloon framing method when connecting floors in split level designs. 17. Nail all whear walls to floor joist using 2: 16d 16" O.C. Add additional floor joist as regd. 18. Provide joist and rafter hangers as per manufacturers specifications. 19. Foundation steps shall not exceed 4 feet or %2 the horizontal distance between steps. Horz. rebar shall be 12" O.C. through step downs and extend 48" either side of step 20.If garage return walls are less than 32" wide then extend headers across return walls with 2 king studs on either end extending from the top of the header to the bottom plate or install (2) MST 36 straps each end of header extend across wing walls. 21. Use a minimum of 2-9 1/2" LVLs for all headers carrying girder loads. 22. Allow foundation 14 days to cure prior to backfill 23. Use 1 1/8" wide timberstrand or equiv. for all rim joist 24. Provide solid blocking through structure down to footing for all load paths. 25. Builder shall follow all recommendations found in all applicable Geotechnical reports. 26. Stacking of two sill plates is permitted with 5/8" J -bolts through both plates. Stacking more than two plates is not permitted without special engineering boo Plan: Davenport C 1 1 1 Date: 21 March 2008 4 10 5 Location: Lot #2, Block #7, Henderson 1278 1626 Sawn Lumber FB -1 FB -2 FB -2 RB -4 Load Parameters Max Moment FtLb 1359 3194 2033 Floor Live Load(psf) 40 40 40 40 Floor Total Load(psf) 50 50 50 50 Floor 1 Span(ft) 27 10 16 0 Total Floor Load(plf) 675 250 400 0 Wall Height (ft) 0 0 9 0 Wall Weight (psf) 20 20 20 20 Wall Load(plf) 0 0 180 0 Roof LL (psf) 50 50 50 50 Total Roof Load(psf) 65 65 65 65 Roof Span(ft) 0 0 2 47 Total Roof Load(plf) 0 0 65 1528 Beam Weight (plf) 4.4 5.6 5.6 5.6 Live Load (plf) 540 200 370 1175 Total Load (plf) 679 256 651 1533 Reactions & Moment Duration Increase 1 1 1 1 Beam Span(ft) 4 10 5 4 Reaction 1 (lb) 1359 1278 1626 3066 Reaction 2 (lb) 1359 1278 1626 3066 Max Moment FtLb 1359 3194 2033 3066 Max Shear Lb 1359 1278 1626 3066 Determine Beam Size Depth Estimate (in) 7.25 9.25 9.25 9.25 Width Estimate (in) 3 3 3 CF = 1.20 1.10 1.10 3 1.10 Area = 21.75 27.75 27.75 27.75 Momemt of Inertia 1 = 95 198 198 198 Maximum Bend Stress = 620 896 570 860 Allowable bend Stress 1020 935 935 935 Factor Of Safety = 1.64 1.04 1.64 1.09 Allowable Sheer Stress 180 165 165 165 Max Shear Cap (Ibs) = 2610 3053 3053 3053 Factor Of Safety = 1.92 2.39 1.88 1.00 Bearing Required = 1.12 1.05 1.34 2.52 E(psi) Deflection LL (in) 1300000 0.03 1300000 1300000 1300000 0.17 0.02 0.03 LLoad Def. Limit L/ 360 360 360 360 Allowable Deflection (in) 0.13 0.33 0.17 0.13 LL Deflection FIS 5.31 1.91 8.24 5.07 Deflection TL (in) 0.03 0.22 0.04 0.03 TLoad Def. Limit L/ 240 240 240 240 Allowable Deflection (in) 0.2 0.5 0.25 0.2 TL Deflection FIS 6.33 2.24 7.03 5.83 Selection 2: 2 x 8 2: 2 x 10 2: 2 x 10 2: 2 x 10 lim Plan: Davenport C Date: 21 March 2008 Location: Lot #2, Block #7, Henderson Exterior Footing Calculations back front left right Concrete Specs Density (pcf) 150 150 150 150 Strength (psi) 3000 3000 3000 3000 Clear Cover Thickness (in) 3 3 3 3 Foundation Overall Height (ft) 4.67 4.67 4.67 4.67 Height (in) 56 56 56 56 Wall Thickness (ft) 0.67 0.67 0.67 0.67 Thickness (in) 8 8 8 8 Weight (kips/ift) 0.47 0.47 0.47 0.47 Footing Specs Width (ft) 1.67 1.67 1.67 1.67 Width (in) 20 20 20 20 Height (ft) 0.83 0.83 0.83 0.83 Height (in) 10 10 10 10 Weight (kips/Ift) 0.21 0.21 0.21 0.21 Area per Ift 1.67 1.67 1.67 1.67 Soil Specs Density (pcf) 125 125 125 125 Soil Pressure (psf) 1500 1500 1500 1500 Weight (kips/Ift) 0.29 0.29 0.29 0.29 Building Loads Roof span 46 46 2 2 Roof (kips/Ift) 1.24 1.24 0.05 0.05 Wall Height (ft) 16 16 16 12 Wall Load (kips/Ift) 0.32 0.32 0.32 0.24 Floor span 2 2 19 14 Floor Loads (kips/Ift) 0.05 0.05 0.48 0.35 Total (kips.lft) 1.61 1.61 0.85 0.64 Calculations Total Weight on Soil (kips) 2.29 2.29 1.52 1.32 Soil Load (ksf) 1.37 1.37 0.91 0.79 Required Footing Width (in) 20 20 20 20 Required Footing Depth (in) 10 10 10 10 Note: Interior footing sizes are noted on plan LVL Beam Load Parameters Floor LL (psf) Total Floor Load(psf) Floor Span (ft) Total Floor Load (plo Wall Height (ft) Wall Weight (psf) Wall Load (plf) Roof LL (psf) Total Roof Load (psf) Roof Span (ft) Roof Load (plf) Beam Weight (plf) Live Load (plf) Total Load (plf) Plan: Davenport C Date: 21 March 2008 Location: Lot #2, Block #7, Henderson RB -1 RB -2 RB -3 Reactions & Moment Duration Increase Beam Span(ft) Reaction 1 (lb) Reaction 2 (lb) Max Moment FtLb Max Shear Lb Max Shear Stress (psi) Determine Size Depth Estimate (in) Width Estimate (in) Cross Area (in ^2) Allowable Bending Stress = Allowable Moment = Momemt of Inertia I = Factor Of Safety = Allowable Sheer Stress (psi)= Allowable Sheer Force (lb)= Factor Of Safety = Bearing Required = E (psi) Deflection LL (in) LLoad Def. Limit U Allowable Deflection (in) LL Deflection F/S Deflection TL (in) TLoad Def. Limit U Allowable Deflection (in) TL Deflection FIS Selection RB -5 RB -5 OPT40 40 40 40 40 50 50 50 50 50 0 0 0 0 0 0 0 0 0 0 7 0 0 0 0 35 20 20 20 20 245 0 0 0 0 30 50 50 50 50 45 65 65 65 65 2 8 22 40 40 45 260 715 1300 1300 12.1 10 10 18 14 30 200 550 1000 1000 302 270 725 1318 1314 1.15 1 1 1 1 16 12 6 12 12 2416 1618 2174 7909 7885 2416 1618 2174 7909 7885 9666 4854 3261 23726 23656 2416 1618 2174 7909 7885 58 49 65 127 161 11.88 9.50 9.50 11.88 14.00 3.5 3.5 3.5 5.3 3.5 42 33 33 62 49 2994 2684 2684 2604 2546 20542 11775 11775 26793 24258 489 250 250 734 800 2.13 2.43 3.61 1.13 1.03 328 285 285 285 285 9085 6318 6318 11850 9310 3.76 3.90 2.91 1.50 1,18 0.92 0.62 0.83 2.01 3.00 1900000 1900000 1900000 1900000 1900000 0.05 0.20 0.03 0.33 0.31 360 360 360 360 360 0.53 0.40 0.20 0.40 0.40 11.20 2.04 5.93 1.19 1.30 0.48 0.26 0.04 0.44 0.40 240 240 240 240 240 0.80 0.60 0.30 0.60 0.60 1.67 2.27 6.75 1.36 1.49 2: 11 7/8" 2:9 %z" 2: 9 %2" 3: 11 7/8" 2: 14" Plan: DavenportC Date: 21 March 2008 Location: Lot #2, Block #7. Henderson Seismic Calculations Loading Summary Floor Dead Load (psf) 10 Seismic Zone E Floor Live Lcad(psf) 40 Walls (Ext)(psf) 20 Roof LL(psf) 50 Walls (Int)(psf) 10 Roof Dead Load(psf) 15 Roof Slope 6/12 Exterior combination Snow Load Reduction Seismic Paramaters Slope 26.56 V=CS'W/1.4 Snow 50.00 Fa= 1 Pitch over 20 R= Rs 6 table 1617.6 Ss= Reduction Sms= 1.772 1.77 eq. 16-16 L.L- Reduction 50.00 Sds= 1.18 eq 16-18 Total Load 65.00 Cs= 0.236 per eq. 165-49 Adj. Factor 1.4 Cs= 0.1686 Roof Length W(psf) Lblft Width W(lb) 41 25 1025 roof wall 50 51250 7280 Total Mass Tributary to Roof Levels = 58530 Shear (V)(lbs) Roof Levels = 9868 Floor Length W(psf) Ib/ft Width W(lb) 41 10 410 50 0 wall height 0 7280 Total Mass Tributary to Floor 2= 0 Shear (V)(lbs) Floor Levels = 0 Floor 1 Length W(psf) Ib/ft Width W(lb) 41 10 410 50 14000 wall height 8 14560 Total Mass Tributary to Floor 1= 28560 Shear M(lbs) Floor Levels = 4815 Floor Lateral Force 4815 Floor 2 Lateral Force 0 Roof Lateral Force 9868 Total Seismic Mass = 87090 Total Lateral Force= 14683 Seismic Force Distribution - Roof Sections"` H(x) W(x) kip W(x)H(x) Roof , % Force Total Sheer Force (Kip) W1046 Floor 1 4.0 29 90.16% 13.2373543 114 Floor 2 0.0 0 9'84% "'*"""' "• 0 Totals 87 1160 0.00% 13.2373543 V/sum(Wi'Hi) = 0.01265 Total Shear (Ibs) = 1 14683 Basement Sheer Wall F(total) Length Total Load (kips) 14.7 Shear Wall Load (plf) right side 7.3 24 306 left side 7.3 24 306 front 7.3 32 229 back 7.3 28 262 Floor 1 Sheer Wall F(total) Length Total Load (kips) 13.2 Shear Wall Load (plf) right side 6.6 37 179 left side 6.6 43 154 front 6.6 25 265 back 6.6 35 189 Floor 2 Sheer Wall F(total) Length Total Load (kips) 13.2 Shear Wall Load (plt) right side 6.6 10 left side Not Applicable 6.6 10 front 6.6 10 Not Applicable back 6.6 10 Not Applicable Not Applicable Shear Wall Critical Lengths Wall DL Floor DL Roof DL Front DL (plf) critical I (ft) 320 50 1242 Back 320 50 1242 1074 4 1074 3 Right 240 475 54 Left 512 6 320 350 54 482 6 Calculate Uplift, Force Req'd to Prevent OT (lbs) Panel Length (ft) 2 3 4 6 8 Front 2618 1545 471 Back 1257 183 10 -1676 -3823 -5970 12 -8118 -890 Right 2196 1683 1171 -3038 -5185 -7332 147 -9479 Left 1806 1324 842 -877 1902 -122 -1087 -2051 2926 -3016 'N. Plan: Davenport C Date: 21 March 2008 Location: Lot #2, Block #7, Henderson Wind Loading Calculations using Main Windforce-Resisting System (MWFRS) Longitudinal Direction Wind Design coefficients P --wind load*exp coeff*lw P=Design Pressure Horizontal Wind Load (from table 1609.6.2.1(1) Wall Load (psf)= end zone (A) 16.1 interior zone (C) 11.7 Roof Load (psf)= end zone (B) 2.6 interior zone (D) 2,7 Vertical Wind Load (from table 1609.6.2.1(1) Roof Load (psi)= end zone windward (E) -7,2 end zone leeward (F) -9.8 interior zone Windward (G) -5.2 interior zone leeward (H) -5.2 Exposure Coefficient (from table 1609.6.2.1(4) 1.21 Iw=Importance Factor (from table 1604.5) 1.0 Wind speed = 90 Roof Height 11.75 Exposure C Wall Height 12 Truss Span 47 Roof Slope = 16377 6/12 Roof Angle(deg)= 26-56 Sine=D.4472 P --wind load*exp cceff Iw 4058 Minimum Pressure Adjusted horizontal wall interior 14.16 14.16 horizontal wall end zone 19.48 19.48 horizontal roof interior 3.27 10.00 horizontal roof end zone 3.15 10.00 vertical end zone windward -8.71 0.00 vertical end zone leeward -11.86 0.00 vertical interior zone windward -6.29 0.00 vertical interior zone leeward -6.29 0.00 .4*Hmean 18.45 0.00 7.15 .1*base 4.1 End Zone Width (ft) Not Applicable 4.1 Interior Zone Width (ft) 41.8 Gable Roof Load Hip Roof Load Wall Load Vertical Force End Interior End Interior End Interior Width 4.1 41.8 Area 587.5 148.39 Width 4.1 41.8 Width end zone windward 4 leeward 4 interior zone windward 42 leeward 42 Floor 2 Diaphragm Shear Total Shear (Ibs) 7359 Front Wall Length 10 Back Wall Length 10 Flood Diaphragm Shear Total Shear (lbs) 13371 Front Wall Length 25 Hack Wall Length 3s basement Diaphragm Shear Total Shear (lbs) 16377 Front Wall Length 32 Back Wall Length 28 Critical Wall Length (ft)= 4058 Front Wall Dead Load (plf)= 1074 Front Wall Critical Length (ft)= 2 Back Wall Dead Load (plf)= 1074 Back Wall Critical Length (ft)= 2 Calculate Uplift, Force Req'd to Prevent OT (Ibs) Panel Length (ft) 2 3 Front Back 605 105 147 -353 2nd storyEnd Zone Width (ft) 2nd Storylnterior Zone Width (ft) Height Wind Load Force (Ibs) 2.0 19.48 157 4.89 14.16 4058 Sum = 4215.507 Wind Load Force (Ibs) 10.00 5875 10.00 1484 Total 7359 Height Wind Load Force (Ib/ft) 1.0 19.48 160 1. GO 14.16 592 Sum = 751.5068 length Wind Load Force (Ibs) 18.45 0.00 0 18.45 0.00 0 18.45 0.00 0 18.45 0.00 0 Shear Wall Loads (plf) Not Applicable Not Applicable Shear Wall Loads (plf) 267 191 Shear Wall Loads (plf) 256 292 Total 13471 Total (plf) 74 4.1 41.8 2nd Story Force (Ibfit) 159.74 591.76 751.51 4 6 8 10 12 -395 -1394 -2394 -3393 -4393 -853 -1853 -2852 -3852 -4851 1041,111 Plan: Davenport C Date: 21 March 2008 Location: Henderson Wind Loading Calculations using Main NI ndfore-Re isting System (MWFRS) Transverse Direction Wind Design Coefficients P=wind load`exp coeff fw P=Design Pressure Horizontal Wind Load (from table 1609.6.2.1(1) Wall Load (psf)= end zone (A) 16.1 interior zone (C) 11.7 Roof Load (psi)= end zone (B) 2.6 interior zone (D) 2.7 Vertical Wind Load (from table 1609.6.2.1(1) Roof Load (psf)= end zone windward (E) -7.2 end zone leeward (F) -9.8 interior zone windward (G) -5.2 interior zone leeward (H) -5.2 Exposure Coefficient (from table 1609.621(4) 121 Iw=Importance Factor (from table 1604.5) 1.0 Wind speed= 90 Roof Height 11.75 Exposure C Wall Height 12 Truss Span 47 Roof Slope = 6/12 10975 Left Wall Length 43 Roof Angle (deg)= 26.56 Sine= 0.4472 Total Shear (Ibs) 13471 Left Wall Length 24 Minimum Pressure 24 Critical Wail Length (ft)= P --wind load`exp coeff Iw 482 Adjusted 3 Right Wall Dead Load (plf)= 512 horizontal wall interior 14.16 14.16 Prevent OT (Ibs) Panel Length (ft) 2 3 horizontal wall end zone 19.48 19.48 horizontal roof interior 3.27 10.00 horizontal roof end zone 3.15 10.00 vertical end zone windward -8.71 0.00 vertical end zone leeward -11.86 0.00 vertical interior zone windward -6.29 0.00 vertical interior zone leeward -6.29 0.00 End Zone Width (ft) 4.1 2nd storyEnd Zone Width (ft) 4.1 Interior Zone Width (ft) 32.8 2nd Storylnterior Zone Width (ft) 32.8 Gable Roof Load Width Height Wind Load Force (lbs) End 4.1 20 19.48 157 Interior 32.8 4.89 14.16 3185 Sum = 3341.68 Area Hip Roof Load End 481.75 10.00 4818 Interior 116.44 10.00 1164 Total 5982 Wall Load Width Height Wind Load Force (lbs) 2nd Story End 4.1 1.0 19.48 160 159.744 Interior 32.8 1.00 14.16 464 464.35 Sum = 624.0938 624.094 Vertical Force Width length Wind Load Force (lbs) end zone windward 4 42.95 0.00 0 leeward 4 42.95 0.00 0 interior zone windward 33 42.95 0.00 0 leeward 33 42.95 0.00 0 Floor 2 Diaphragm Shear Total Shear(Ibs) 5982 Left Wall Length 10 Right Wall Length 10 Floor 1 Diaphragm Shear Total Shear Obs) 10975 Left Wall Length 43 Right Wall Length 37 basement Diaphragm Shear Total Shear (Ibs) 13471 Left Wall Length 24 Right Wall Length 24 Critical Wail Length (ft)= Left Wall Dead Load (plf)= 482 Left Wall Critical Length (ft)= 3 Right Wall Dead Load (plf)= 512 RightWall Critical Length (ft)= 3 Calculate Uplift, Force Req'd to Prevent OT (Ibs) Panel Length (ft) 2 3 Front Back 364 163 458 242 Shear Wall Loads (plf) Not Applicable Not Applicable Shear Wall Loads (plf) 128 148 Shear Wall Loads (pif) 281 281 Total 16377 Total (plf) 80 4 6 8 10 12 -38 -439 -841 -1243 -1645 26 -405 -837 -1269 -1700 Plan: Davenport C Date: 21 March 2008 Location: Lot #2, Block #7, Henderson BCI JOISTS 6000 1.7E Span (ft) 12 Depth 11.88 Load Parameters Floor Dead Load 10 Floor Live Load 40 Total Floor Load 50 Simple Span Joist Duration Increase Joist Span(ft) Joist Spacing Joist Weight (plf) Joist Loading (plf) Max Reaction (Ibs) Max Moment (FtLb/If) Max Shear Lb Determine Joist Size Depth = Max Moment 100% (ft-Ibs) _ F. S. for moment = Max Shear 100% (Ibs) _ F. S. for shear = Bearing Required (in.)= Live Load (L/360) _ Total Load (L/240) _ EI x 10^6 (Ib-in^2) K x 10^6 (Ibs) Live Load Deflection (in) Total Load Deflection (in) Live Load F of S Total Load F of S 1 12 19.2 2.5 83 495 1485 495 11 7/8" 3670 2.47 1675 3.38 2.00 0.40 0.60 305 6 0.12 0.15 3.44 4.00 6000 1.7E 19 11.88 10 40 50 1 19 16 2.5 69 657 3121 657 11 7/8" 3670 1.18 1675 2.55 2.00 0.63 0.95 305 6 0.55 0.71 1.15 1.33 Selection 11718" 60001.7E @ 19.2" 11718" 60001.7E @ 16" Sheer wall lines (three shear wall lines) Dimensions D1= 15 ft D2 = 28 ft Length = 43 ft Total Shear per foot Ib Seismic 12626 lb Wind 13371 Ib Shear Wall line loads Hem Fir Reduction 0.95 Wind Increase 1.4 Line T1 Tributalry Area Seismic Vseismic = Resistence Sheer Wall SW -1 SW -1 SW -1 SW -5 Portal Frame Wind Vwind = Resistence Sheer Wall SW -1 SW -1 SW -1 SW -5 Portal Frame 0.17 Total Area 2202 Ib Length per Height per Resistence length Total annel ft annel ft per foot Ib ft Resistence Ib 3 8 271 6 1625 2.5 8 226 5 1128 3 8 271 0 0 4 8 466 0 0 Length per Height per Resistence number Total annel ft annel ftper pannel Ib of pannels Resistence Ib 2 8 1615 0 0 Sum = 2753 Factor of Safety 1.25 2332 Ib Length per Height per Resistence length Total annel ft annel ft er foot Ib ft Resistence Ib 3 8 505 6 3032 2.5 8 505 5 2527 3 8 505 0 0 4 8 652 0 0 Length per Height per Resistence number Total annel ft annel per pannel Ib of pannels Resistence Ib 2 8 1615 0 0 Sum = 5559 Factor of Safety 238 E:j Line T2 Tributalry Area 0.50 Total Area Seismic Vseismic = 6313 Ib Resistence Sheer Wall Length per Height per Resistence length Total SW -1 annel ft annel ft per foot Ib ft Resistence Ib SW -1 4 4 8 361 8 20 7220 SW -1 4 361 8 361 0 0 0 SW -5 4 8 466 0 0 0 Length per Height per Resistence number Total Portal Frame annel ft annel ftper pannel Ib of pannels Resistence Ib 1.3 10 570 0 0 Sum = 7220 Factor of Safety 1.14 Wind Vwind = 6686 Ib Resistence Sheer Wall Length per Height per Resistence length Total SW -1 annel ft annel ft per foot Ib ft Resistence Ib) SW -1 4 4 8 505 8 20 10108 SW -1 4 505 8 505 0 0 0 S W-5 4 8 652 0 0 0 Length per Height per Resistence number Total Portal Frame annel ft annel ft er annel Ib of pannels Resistence ON 1.3 10 570 0 0 Sum = 10108 Factor of Safety 1.51 Line T3 Tributalry Area 0.33 Total Area Seismic Vseismic = 4111 Ib Resistence Sheer Wall Length per Height per Resistence length Total SW -1 annel ft annel ft per foot Ib ft Resistence Ib SW -1 4 8 3.5 8 361 22 7942 SW -1 4 8 316 361 0 0 SW -5 � 8 466 0 0 0 Length per Height per Resistence number Total 0 Portal Frame annel ftannel ft er annel Ib of pannels Resistence Ib 1.3 10 570 0 0 Sum = 7942 Factor of Safety 1.93 Wind Vwind = 4353 Ib Resistence Sheer Wall Length per Height per Resistence length Total SW -1 annel ftannel ft er foot Ib ft Resistence Ib SW -1 4 8 34 505 22 11119 SW -1 8 505 505 0 0 SW -5 4 8 652 0 0 0 Length per Height per Resistence number 0 Total Portal Frame annel ft annel ft per pannel Ib of pannels Resistence Ib 1.3 10 570 0 0 Sum = 11119 Factor of Safety 2.55