Loading...
HomeMy WebLinkAboutSUBDIVISION APPLICATION - 03-00050 - Teton River Village Building #1 - 8 UnitsPlanning and Zoning Subdivision Application Application for Approval of Preliminary Subdivision Plat The attached Subdivision plan has been prepared in accordance with the Subdivision Regulations of the City of Rexburg, and the following items are shown on the plan or plans, or explanations given with respect thereto. Requirements for Preliminary Plats: All Preliminary plats shall be 24" x 36" foldable, drawn to scale, North point, dated. The following Shall be shown on the Preliminary Plat or shall be submitted separately: 1. The name of the proposed subdivision: Teton River village 2. The location Ser_. 19. M. a40E. -Acreage-1-2 - 25 Number of Lots 5 3. The names, addresses and telephone numbers of the subdivider or subdividers and the engineer or surveyor who prepared the plat: Name Address Phone Numbers See Attached Engineer See Attached Survevor See Attached 4. The name and address of all property owners within 300 feet of the external boundaries of the subdivision whether or not bisected by a public right-of-way as shown on record in the County Assessor's office. - Place on Preliminary Plat. 5. The legal description of the subdivision. - Place on Preliminary Plat. 6. A statement of the intended use of the proposed subdivision, such as: Residential - (single family, two family and multiple housing); Commercial, Industrial, Recreational or Agricultural. Show sites proposed for parks, playgrounds, schools, churches or other public areas. Multi -family and Commercial T ntc cily ®f do X in b"? F.O. Box 280 12 North Center Street cT Rexburg, Idaho 83440 4 Phone (208) 359-3020 �� 1$ 9BLISHEQ STATE OF IDAHO Fax (208) 359-3022 Planning and Zoning Subdivision Application Application for Approval of Preliminary Subdivision Plat The attached Subdivision plan has been prepared in accordance with the Subdivision Regulations of the City of Rexburg, and the following items are shown on the plan or plans, or explanations given with respect thereto. Requirements for Preliminary Plats: All Preliminary plats shall be 24" x 36" foldable, drawn to scale, North point, dated. The following Shall be shown on the Preliminary Plat or shall be submitted separately: 1. The name of the proposed subdivision: Teton River village 2. The location Ser_. 19. M. a40E. -Acreage-1-2 - 25 Number of Lots 5 3. The names, addresses and telephone numbers of the subdivider or subdividers and the engineer or surveyor who prepared the plat: Name Address Phone Numbers See Attached Engineer See Attached Survevor See Attached 4. The name and address of all property owners within 300 feet of the external boundaries of the subdivision whether or not bisected by a public right-of-way as shown on record in the County Assessor's office. - Place on Preliminary Plat. 5. The legal description of the subdivision. - Place on Preliminary Plat. 6. A statement of the intended use of the proposed subdivision, such as: Residential - (single family, two family and multiple housing); Commercial, Industrial, Recreational or Agricultural. Show sites proposed for parks, playgrounds, schools, churches or other public areas. Multi -family and Commercial T ntc 7. A map of the entire area scheduled for development if the proposed subdivision is a portion of a larger holding intended for subsequent development. See Preliminary Plat. 8. A vicinity map showing the relationship of the proposed plat to the surrounding area (Y2 mile of minimum radius, scale optional). See Preliminary Plar. 9. The land use and existing zoning of the proposed subdivision and the adjacent land. Existing zoning is HBD and LI. 10. Does subdivision conform to present zoning? Will conform after proposed zone change. 11. Requested zoning HBD (Not part of this application) 12. Variance Requested. Yes. 13. Requesting annexation to City?. No x of yes, attach written request) N/A 14. Streets, street names, rights-of-way, and roadway widths, including adjoining streets or roadways, curbs and sidewalks See Prel i mi nar)z P1 at _ 15. Lot lines and blocks showing the dimensions and numbers of each. See Pre 1 i m i n a ry Plat. 16. Contour lines, shown at five (5) feet intervals where land slope is greater than ten percent (10%) and at two (2) feet intervals where land slope is ten percent (10%) or less, referenced to an established bench mark, including location and elevation. See Preliminary Plat 17. A site report as required by the appropriate health district where individual wells or septic tanks are proposed, this shall be in the form of a letter. 18. Any proposed or existing utilities, including, but not limited to, storm and sanitary sewers, irrigation laterals, ditches, drains, bridges, culverts, water mains, fire hydrants, power, gas, street lights and their respective profiles and easements. 19. Public services and other departments. approval: (signatures necessary) a. water f. City Engineer b. sewer g. Planning Commission c. fire and police h. City Council d. electric and/or gas e. street and traffic_ 20. A copy of any proposed restrictive covenants and/or deed restrictions. (To be attached or submitted with final plat) OWNER / DEVELOPER ELLSWORTH-PAULSEN CONSTRUCTION SERVICES CAMERON GUNTER - CONTACT 195 EAST 600 SOUTH AMERICAN FORK, UTAH 84003 (801) 756-0404 SURVEY AND ENGINEERING HARPER - LEAVITT ENGINEERING KIM LEAVITT - SURVEYOR JEFF FREIBERG - ENGINEER oKly-0r.'" IDAHO FALLS, IDAHO 83402 (208) 524-0212