HomeMy WebLinkAboutCOMCHECK - 08-00151 & 08-00152 - Upper Valley Options - AdditionCOMcheck Software V(
Envelope Com 08 001 52
Upper Valley Options Addition
2003 IECC
U -Factor
Report Date: 09/24/07
Exterior Wall 3: Wood Frame, Any Spacing
Data filename: C:\Users\jeff\Pictures\UVOptions.cck
Section 1: Project Information
0.068
Project Title: Upper Valley Option - New Building Addition
Orientation: SOUTH -� '� 45
Construction Site: Owner/Agent:
1120 Stocks Avenue, Rexburg Business Park Scott Birkinbine
Designer/Contractor:
Rexburg , ID
Upper Valley Options
Newell Goldsberry
Sundberg & Assoc., Inc.
1120 Stocks Avenue
Rexburg, ID 83440
111 E. 16th Street
(208)359-3133
Idaho Falls, ID 83401
Section 2: General Information
0.320
Building Location (for weather data): Rexburg, Idaho
Orientation: WEST 38 -' --
Climate Zone: 16
Heating Degree Days (base 65 degrees F): 8693
Cooling Degree Days (base 65 degrees F): 143
PE ANENNT D
+i,a (; � ,r„
Origination Date:
Project Type: Addition
Vertical Glazing / Wall Area Pct.: 8%
g
G'Om pletion Date: Cg_
Building Type Floor Area
Medical and Clinical Care
DO NOT DESTRO i
2738
ATt11� 81tATE
Section 3: Requirements Checklist
41y @ AS"I �tMCHIt/Itri
Climate -Specific Requirements:
Component Name/Description Gross Area Cavity Cont. Proposed Budget
or P '
Orientation: EAST e. meter R -Value R -Value
U -Factor
LI -Factor
Exterior Wall 3: Wood Frame, Any Spacing
480 19.0 0.0
Door 2: Solid
0.068
0.067
Orientation: SOUTH -� '� 45
0.150
0.112
Exterior Wall 2: Wood Frame, Any Spacing
810 19.0 0.0
Window 2: Vinyl Frame:Double Pane with Low -E, Clear, SHGC 0.36
0.068
0.067
44
Door 1: Glass, Clear, SHGC 0.32 ' --
0.320
0.520
Orientation: WEST 38 -' --
0.590
0.520
Exterior Wall 1: Wood Frame, Any Spacing 480 19.0
0.0
Window 1: Vinyl Frame:Double Pane with Low -E, Clear, SHGC 0.36 55
0.068
0.067
Orientation: UNSPECIFIED ORIENTATION --
0.320
0.520
Roof 1: All -Wood Joist/Rafter/Truss
Floor 1: Slab-On-Grade:Unheated 2738 38.0 0.0
0.028
0.047
169
_
(a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements.
N
Air Leakage, Component Certification, and Vapor Retarder Requirements:
LJ 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in
accordance with the manufacturer's installation
instructions.
Upper Valley Option - New Building Addition
Page 1 of 2
2. Windows, doors, and skyligh,_ ed as meeting leakage requirements.
Lj 3. Component R -values & U -factors labeled as certified.
L] 4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R -value without compressing the insulation.
a� 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers.
Lj 6. Cargo doors and loading dock doors are weather sealed.
7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly
with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material.
8. Building entrance doors have a vestibule and equipped with closing devices.
Exceptions:
Building entrances with revolving doors.
Doors that open directly from a space less than 3000 sq. ft. in area.
9. Vapor retarder installed.
W1
Section 4: Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The propos envel a system has been designed to meet the 2003 IECC
requirements in COMcheck Version 3.4.2 and to comply with the mandato rements ig)he}&quirements Checklist.
ii
�V�WPXXZJ VFW
Upper Valley Option - New Building Addition
Page 2 of 2