HomeMy WebLinkAboutRESCHECK - 20-00794 - 1111 Castle PInes - New SFRREScheck Software Version 4.7.1 Compliance Certificate Project T. Webb Construction - Lexington Res. Energy Code:2015 IECC Location:Rexburg, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:3,814 ft2 Glazing Area 14% Climate Zone:6 (8693 HDD) Permit Date: Construction Site:Owner/Agent: T. Webb Construction- Lexington Residence Designer/Contractor: Freedom Heating, Inc. Freedom Heating, Inc. P.O Box 51966 Idaho Falls, ID 83405 208-339-0344 Freedomheatinginc@yahoo.com Permit Number: Compliance: Passes using UA trade-off 3.4% Better Than Code Maximum UA:328 Your UA:317 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.497 21.0 0.0 0.057 22 Door 1: Solid 42 0.140 6 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 69 0.260 18 Wall 2: Wood Frame, 16" o.c.466 21.0 0.0 0.057 26 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.260 4 Wall 3: Wood Frame, 16" o.c.497 21.0 0.0 0.057 22 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 112 0.260 29 Wall 4: Wood Frame, 16" o.c.466 21.0 0.0 0.057 24 Door 1: Solid 21 0.140 3 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 31 0.260 8 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 6.5' Insulation depth: 9.0' 495 19.0 0.0 0.048 24 Basement Wall 2: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 6.5' Insulation depth: 9.0' 459 19.0 0.0 0.048 21 Project Title: T. Webb Construction - Lexington Res. Data filename: C:\Users\Freedom Heating\AppData\Local\Check\REScheck\T. Webb Construction - Lexington Res..rck Page 1 of 2 10/08/20Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.260 4 Basement Wall 3: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 6.5' Insulation depth: 9.0' 495 19.0 0.0 0.048 22 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.260 8 Basement Wall 4: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 6.5' Insulation depth: 9.0' 459 19.0 0.0 0.048 22 Ceiling 1: Flat Ceiling or Scissor Truss 2,077 50.0 0.0 0.026 54 Freedom Heating, Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.7.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: T. Webb Construction- Lexington Residence INFORMATION CONTAIN WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: T. Webb Construction - Lexington Res. Data filename: C:\Users\Freedom Heating\AppData\Local\Check\REScheck\T. Webb Construction - Lexington Res..rck Page 2 of 2 10/08/20Report date: 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 21.00Above-Grade Wall 19.00Below-Grade Wall 0.00Floor 50.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.26Window 0.14Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments