Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
COVER SHEET REDLINED - 19-00604 - America First Credit Union - Remodel
SITE AFCU LEASE SPACE A B C D 1 X AX.X X AX.X 1 1 A1 AX.X X 1 1 SYMBOLS XXX OFFICE INDICATES FINISHED GLAZED MASONRY WALL INDICATES PAGE NO. INDICATES SECTION NO. INDICATES DETAIL NO. INDICATES PAGE NO. INDICATES GRID NUMBER INDICATES ROOM NAME INDICATES ROOM NUMBER KEYNOTE REVISIONS FLOOR TYPE A METAL OR METAL STUDS MASONRY WALL WOOD WALL FINISHED WOOD BLOCKING CONTINUOUS WOOD RIGID INSULATION BATT INSULATION INDICATES WALL TYPE INDICATES OBJECT DOOR NUMBER INDICATES ELEVATION NO. INDICATES PAGE NO. INDICATES ELEVATION WINDOW NUMBER INDICATES GLASS TYPE GYP. BD., CONC. OR DIMENSION TO FACE OF DIMENSION TO CENTER MASONRY LINE OBJECT ELEVATION CONCRETESTONE CL TE L : 8 0 1 . 5 2 1 . 9 1 1 1 F A X : 8 0 1 . 5 2 1 . 9 1 5 8 SA L T L A K E C I T Y , U T A H 8 4 1 0 1 17 1 W E S T P I E R P O N T A V E . SH E E T N O . DA T E : DR A W N B Y : PR O J E C T N O . : TH E S E D O C U M E N T S A R E I N - ST R U M E N T S O F S E R V I C E AN D S H A L L R E M A I N T H E PR O P E R T Y O F T H E AR C H I T E C T . N O U S E O R R E - US E O F T H E S E D O C U M E N T S SH A L L B E P E R M I T T E D U N L E S S AU T H O R I Z E D I N W R I T I N G B Y PR E S C O T T M U I R A R C H I T E C T WI T H A P P R O P R I A T E C O M P E N SA T I O N . C O P Y R I G H T © PR E S C O T T M U I R A R C H I T E C T TI T L E S H E E T + A R C H I T E C T U R A L S I T E A N D F O O R P L A N TI T L E S H E E T + A R C H I T E C T U R A L S I T E A N D F O O R P L A N TI T L E S H E E T + A R C H I T E C T U R A L S I T E A N D F O O R P L A N TI T L E S H E E T + A R C H I T E C T U R A L S I T E A N D F O O R P L A N T1 AMERICA FIRST CREDIT UNION REXBURG BRANCH T.I. 510 NORTH 2ND EAST, SUITE 3 REXBURG, ID 83440 10.04.19 CONSTRUCTION SET MC 10 . 0 4 . 1 9 19 0 8 0 AM E R I C A F I R S T C R E D I T U N I O N AM E R I C A F I R S T C R E D I T U N I O N AM E R I C A F I R S T C R E D I T U N I O N AM E R I C A F I R S T C R E D I T U N I O N 51 0 N O R T H 2 N D E A S T , S U I T E 3 51 0 N O R T H 2 N D E A S T , S U I T E 3 51 0 N O R T H 2 N D E A S T , S U I T E 3 51 0 N O R T H 2 N D E A S T , S U I T E 3 RE X B U R G , I D 8 3 4 4 0 RE X B U R G , I D 8 3 4 4 0 RE X B U R G , I D 8 3 4 4 0 RE X B U R G , I D 8 3 4 4 0 RE X B U R G B R A N C H T . I . RE X B U R G B R A N C H T . I . RE X B U R G B R A N C H T . I . RE X B U R G B R A N C H T . I . 20 1 9 A1.1 REFERENCE PLAN/ REFLECTED CEILING PLAN A1.1A FLOOR FINISH PLAN/ EQUIPMENT PLAN A3.1 PARTIAL BUILDING SECTIONS/ ELEVATION/ DETAILS A4.1 RESTROOM INTERIOR ELEVATIONS/ ENLARGED RESTROOM PLAN/ DETAILS A4.2 INTERIOR ELEVATIONS A4.3 MILLWORK DETAILS A4.4 MILLWORK DETAILS A6.1 WALL TYPE SCHEDULE A6.2 SCHEDULES A6.3 DETAILS T1 TITLE SHEET+ ARCHITECTURAL SITE AND FOOR PLAN INDEX OF DRAWINGS D1.1 DEMOLITION FLOOR PLAN NO. SHEET TITLE PRESCOTT MUIR ARCHITECT 171 WEST PIERPONT AVENUE SALT LAKE CITY, UT 84101 801.521.9111 FAX 801.521.9158 AMERICA FIRST CREDIT UNION 4646 SOUTH 1500 WEST #100 RIVERDALE, UTAH 84405 801.827.8539 ELECTRICAL ENGINEER MECHANICAL ENGINEER ARCHITECT OWNER ARCHITECTURAL MECHANICAL PLUMBING ELECTRICAL NOT TO SCALEVICINITY MAP M-001 MECHANICAL SCHEDULES MH101 MECHANICAL DEMOLITION AND REMODEL PLAN P-001 PLUMBING SCHEDULES PL101 PLUMBING DEMOLITION AND REMODEL PLAN E0.1 ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND SCHEDULES E0.2 ELECTRICAL DETAILS AND SCHEDULES E1.1 ELECTRICAL CEILING LIGHT PLAN/ FLOOR POWER PLAN HEATH ENGINEERING COMPANY 377 WEST 800 NORTH SALT LAKE CITY, UT 84101 801.322.0487 ECE - ELECTRICAL CONSULTANT ENGINEERS, LLC. 939 SOUTH WEST TEMPLE SALT LAKE CITY, UTAH 84101 801.521.8007 N ABBREVIATIONS F.O.FACE OF M.R. P.C.J. SIM. R.D. N.I.C. SIMILAR ROOF DRAIN PLASTER CONSTRUCTION JOINT NOT IN CONTRACT MOISTURE RESISTANTANCHOR BOLT CONTROL JOINT CATCH BASIN ADJUSTABLE CONCRETE A.B. C.B. ADJ. C.J. A.C. CONC. ASPHALTIC CONCRETE T.W. S. STL. T.O.C. U.N.O. V.C. TYP. T.O.W. T.O.S. UNLESS NOTED OTHERWISE VINYL COMPOSITION TYPICAL TOP OF WALL TOP OF STEEL TOP OF WALK STAINLESS STEEL TOP OF CONCRETE WITHW/ EXPANSION JOINT DIFFUSER EQUAL FINISH FLOOR FLOOR DRAIN EXTERIOR EXISTING ELEVATION DIF. E.J. EQ. F.F. F.D. EXT. EL. EXIST. INTERIOR GYPSUM BOARD FIRE TREATEDF.T. INT. GYP.BD. F.S.R.FLEXIBLE SHEET ROOFING CONTINUOUSCONT. STEELSTL. V.I.F.VERIFY IN FIELD T.O.TOP OF BOTTOM OFB.O. 1. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COMPLY WITH ALL LAWS, RULES AND REGULATIONS OF THE JURISDICTION IN WHICH THE BUILDING WILL BE CONSTRUCTED. 2. THE CONTRACTOR SHALL CAREFULLY EXAMINE ALL PLANS AND SPECIFICATIONS PERTAINING TO THIS WORK; AND SHALL VISIT THE SITE TO FULLY INFORM HIMSELF OF ALL CONDITIONS AND LIMITATIONS APPLYING TO HIS WORK. 3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE BEFORE START OF WORK, AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION. 4. SUBSTITUTIONS: NO SUBSTITUTIONS SHALL BE MADE WITHOUT THE OWNER'S AND/ OR ARCHITECTS' WRITTEN APPROVAL. 5. CHANGES: THE OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, TO, OR DEDUCTING FROM WORK, WITH THE CONTRACT SUM BEING ADJUSTED ACCORDINGLY. 6. THE ARCHITECT'S APPROVAL OF SHOP DRAWINGS SHALL NOT RELIEVE THE GENERAL OR SUBCONTRACTOR FROM RESPONSIBILITY OR DEVIATION FROM THE PLANS AND SPECIFICATIONS. 7. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK AND MATERIALS PROVIDED BY OTHERS, AND SCHEDULE THE TIMING SO AS NOT TO CAUSE DELAYS TO ANY PHASE OF CONSTRUCTION. 8. ALL TRADES SHALL FURNISH ALL LABOR, EQUIPMENT, MATERIAL AND PERFORM ALL WORK NECESSARY TO COMPLETE THEIR SCOPE OF THE WORK. 9. THE OWNER/ CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THAT NO PERMANENT STRUCTURES ARE BUILT OVER ANY EASEMENT. 10. WARRANTIES: EACH CONTRACTOR SHALL WARRANT ALL WORK PERFORMED BY HIM EQUIPMENT AND LABOR. 11. A SEPARATE PERMIT IS REQUIRED FOR: A. FIRE SPRINKLERS B. SIGNS C. MECHANICAL WORK D. PLUMBING WORK E. ELECTRICAL WORK 12. ALL EXIT DOORS MUST BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. SEE EXCEPTION FOR ALLOWING KEY-LOCKING FLUSH OR SURFACE BOLTS ARE PROHIBITED. AUTOMATIC FLUSH BOLTS ARE ALLOWED ON PAIRS MOUNTED HARDWARE AND THE UNLATCHING OF ANY LEAF REQUIRES ONLY A SINGLE OPERATION. (1003.1.8) 13. EXIT SIGN, ILLUMINATION OF EXIT PATH AND EMERGENCY LIGHTING SHALL BE PROVIDED. 14. MODIFY EXISTING FIRE SPRINKLER SYSTEM AS REQUIRED IN ALL AREAS WHERE REMODELING OCCURS, TO COMPLY WITH CODE. REFER TO THE REFLECTED CEILING PLAN FOR AREAS WHERE CEILINGS ARE TO BE MODIFIED. COORDINATE MODIFICATION OF FIRE SPRINKLING SYSTEM WITH AUTHORITY HAVING JURISDICTION. GENERAL NOTES BUILDING INFORMATION PROJECT: AMERICA FIRST CREDIT UNION REXBURG BRANCH TENANT IMPROVEMENT PROJECT ADDRESS: 510 NORTH 2ND EAST, SUITE 3 REXBURG, ID 83440 APPLICABLE CODES/ GUIDELINES: INTERNATIONAL BUILDING CODE: 2015 UNIFORM MECHANICAL CODE: 2015 IDAHO PLUMBING CODE:2015 INTERNATIONAL FIRE CODE: 2015 INTERNATIONAL EMERGENCY CONSERVATION CODE: 2015 NATIONAL ELECTRICAL CODE: 2017 ADA ACCESSIBILITY CODE: ICC/ ANSI A117.1-2009 PROJECT DESCRIPTION:TENANT IMPROVEMENT 1. OCCUPANCY CLASSIFICATION B - BUSINESS (IBC SECTION 304) 2. MIXED USE OCCUPANCY NO 3. CONSTRUCTION TYPE - IBC TABLE 5.3/ SECTION 602.2: TYPE V-B WALMART ORIGINAL CONSTRUCITON TYPE (UBC 1991) TYPE V-N 4. TENANT IMPROVEMENT (AREA): 1,353 SQ. FT. 5. FIRE - RESISTANCE RATING REQUIREMENTS: NA 6. FIRE SPRINKLERS - IBC SECTION 903: YES OCCUPANCY:ACCESSIBLE OCCUPANCY 7. DESIGN OCCUPANT LOAD - IBC TABLE 1004.1.2: LOAD FACTOR - BUSINESS AREA: 100 S.F. (GROSS) GROSS AREA: 1,353 S.F. PER 1,353 S.F./ 100 S.F. PR OCCUPANT TOTAL: 14 OCCUPANTS NUMBER OF STORIES:TENANT IMPROVEMENT IS LIMITED TO THE MAIN FLOOR ONLY. 8. EGRESS WIDTH AND NUMBER OF EXITS: A. NUMBER OF EXITS REQUIRED IBC TABLE 1006.2.1 1 EXIT B. NUMBER OF EXITS PROVIDED: 1 EXIT C. EXIT WIDTH REQUIRED IBC 1010.1: 32" D. EXIT WIDTH PROVIDED: 36" 9. COMMON PATH OF EGRESS TRAVEL - IBC TABLE 1006.2.1: A. ALLOWED MAXIMUM COMMON PATH OF EGRESS TRAVEL: 100 FEET B. ACTUAL MAXIMUM COMMON PATH OF EGRESS TRAVEL: 28 FEET 10. EXIT TRAVEL DISTANCE - IBC TABLE 1017.2: A. ALLOWED MAXIMUM EXIT ACCESS TRAVEL 300 FEET DISTANCE, OCCUPANCY B B. ACTUAL MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 73 FEET 11. MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - IBC 2902.1 REQUIRED: PROVIDED: A. WATER CLOSETS: M/F - 1 M/F - 1 B. URINALS: - - C. LAVATORIES: M/F - 1 M/F - 1 D. DRINKING FOUNTAIN: - - E. SERVICE SINK: - - N AFCU LEASE SPACE/ SITE VIEW NOT TO SCALE L1.1 LIFE SAFETY PLAN MH501 MECHANICAL DETAILS MH502 MECHANICAL DETAILS 10 . 1 6 . 1 9 1 1 10.04.19 PERMIT SET