HomeMy WebLinkAboutSTRUCTUAL CALCULATIONS - 20-00796 - 1068 Cypress Loop - New SFRFROST Structural Engineering 1020 Lincoln Road Phone: 208.227.8404 Idaho Falls, ID 83401 Fax: 208.227.8405 www.frost-structural.com Project: Coulter Residence Client: TWebb Construction Project No.: IF20-395 Date: Engineer : SEAL: FSE STRUCTURAL CALCULATIONS KBB October 28, 2020 10/28/2020 BASIS FOR DESIGN 1 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence 2 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence 3 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence LATERAL DESIGN 4 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence 5 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence 1 E=2.20 K W=9.30 K 2 E=1.10 K W=4.65 K E=2.20 K W=8.45 K A E=1.00 K W=5.55 K B E=0.25 K W=1.00 K C GARAGE LATERAL KEYPLAN Level =Roof Area =1 Total Seismic Weight = 68.1 Long. Wall Length (ft) =136 105 Area (ft^2) =2000 0 Trans. Wall Length (ft) =64 85 Dead Load (psf) =16 0 Plate Height (ft) =9 9 Live / Snow Load (psf) =35 0 Parapet Height (ft) =0 0 % Live / Snow Load =20% 0% Wall Weight (psf) =15 10 Int. Partition Load (psf) =0 0 Misc. (lbs) =0 0 Misc. (lbs) =0 0 Long. Weight (k) = 9.2 4.7 Weight (k) = 46.0 0.0 Trans. Weight (k) = 4.3 3.8 Transverse Weight (k) =59.9 Longitudinal Weight (k) =54.1 Seismic Weights Walls Roof 6 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence Key Plan Area =1 Risk Category =II Seismic Design Category =D [per ASCE 7-10 tables 11.6-1 and 11.6-2] Importance Factor IE =1.00 Site Class =D Seismic Force Resisting System (Table 12.2-1) = Response Modification Coefficient, R =6.5 Overstrength factor, Ωο =3 Deflection Amplification Factor, Cd =4 Design Spectral Response Accelerations: Ss =43.2%S1 =15.4%[per USGS Earthquake Ground Motion Tool] Fa = 1.45 Fv = 2.18 [per ASCE 7-10 table 11.4-1 & 11.4-2] SMS =0.628g SM1 =0.336g [ASCE 7-10 equation 11.4-1 & 11.4-2] SDS = 0.419g SD1 =0.224g [ASCE 7-10 equation 11.4-3 & 11.4-4] TL =6 CS =0.064 T = 0.160 T0 =0.107 Ct =0.020 Cs-max =0.216 Ta =0.160 TS =0.535 x =0.750 Cs-min =0.018 Tmax =0.224 Sa =0.419 CS (controls)=0.064 CU =1.4 k = 1.00 Main Seismic Force Resisting System: V = CsW =4.4 [per ASCE 7-10 equation 12.8-1] Vertical Distribution of Main Seismic Force Resisting System [per ASCE 7-10 section 12.8.3] Level hx (ft) wx (kip)wx hx k (kip-ft)Cvx Fx (kip) Vx (kip) Roof 16 68.1 1089 1.000 4.4 4.4 Totals: 68 1089 1.0 4.4 Transverse Diaphragm Design Forces [per ASCE 7-10 section 12.10.1.1] Level hx (ft) wpx (kip) ∑wi (kip) ∑Fi (kip) Fpx (min) (kip) Fpx (max) (kip) Fpx (kip) Roof 16 59.9 59.9 3.9 5.0 10.0 5.0 Longitudinal Diaphragm Design Forces [per ASCE 7-10 section 12.10.1.1] Level hx (ft) wpx (kip) ∑wi (kip) ∑Fi (kip) Fpx (min) (kip) Fpx (max) (kip) Fpx (kip) Roof 16 54.1 54.1 3.5 4.5 9.1 4.5 Design Seismic Lateral Loads Equivalent Lateral Force Procedure per Chapters 11 and 12 of ASCE 7-10 [see ASCE 7-10 table 1.5-2] [ASCE 7-10 table 1.5-1] A.Light-frame (wood) walls sheathed with wood structural panels rated for shear resistance 7 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence JOB TITLE JOB NO. SHEET NO. CALCULATED BY DATE CHECKED BY DATE www.struware.com Code Search Code:ASCE 7 - 10 Occupancy: Occupancy Group =R Residential Risk Category & Importance Factors: Risk Category = II Wind factor = 1.00 Snow factor = 1.00 Seismic factor = 1.00 Type of Construction: Fire Rating: Roof = 0.0 hr Floor = 0.0 hr Building Geometry: Roof angle (θ) 7.00 / 12 30.3 deg Building length (L) 68.0 ft Least width (B) 59.8 ft Mean Roof Ht (h) 16.0 ft Parapet ht above grd 0.0 ft Minimum parapet ht 0.0 ft Live Loads: Roof 0 to 200 sf: 17 psf 200 to 600 sf: 20.4 - 0.017Area, but not less than 12 psf over 600 sf: 12 psf Floor: Typical Floor N/A Partitions N/A 8 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence JOB TITLE JOB NO. SHEET NO. CALCULATED BY DATE CHECKED BY DATE Wind Loads :ASCE 7- 10 Ultimate Wind Speed 115 mph Nominal Wind Speed 89.1 mph Risk Category II Exposure Category C Enclosure Classif.Enclosed Building Internal pressure +/-0.18 Directionality (Kd) 0.85 Kh case 1 0.860 Kh case 2 0.860 Type of roof Gable Topographic Factor (Kzt) Topography Flat Hill Height (H) 0.0 ft H< 15ft;exp C Half Hill Length (Lh) 0.0 ft \Kzt=1.0 Actual H/Lh = 0.00 Use H/Lh = 0.00 Modified Lh = 0.0 ft From top of crest: x = 0.0 ft Bldg up/down wind? downwind H/Lh= 0.00 K1 =0.000 x/Lh = 0.00 K2 =0.000 z/Lh = 0.00 K3 =1.000 At Mean Roof Ht: Kzt = (1+K1K2K3)^2 =1.00 Gust Effect Factor Flexible structure if natural frequency < 1 Hz (T > 1 second). h = 16.0 ft However, if building h/B < 4 then probably rigid structure (rule of thumb). B = 59.8 ft h/B = 0.27 Rigid structure /z (0.6h) =15.0 ft G =0.85 Using rigid structure default Rigid Structure Flexible or Dynamically Sensitive Structure ē =0.20 Natural Frequency (η1) =0.0 Hz ℓ = 500 ft Damping ratio (β) = 0zmin =15 ft /b =0.65 c = 0.20 /α = 0.15 gQ, gv =3.4 Vz =97.1 Lz =427.1 ft N1 =0.00 Q =0.91 Rn =0.000 Iz =0.23 Rh =28.282 η =0.000 h =16.0 ft G =0.88 use G = 0.85 RB =28.282 η =0.000 RL =28.282 η =0.000 gR =0.000 R = 0.000 G = 0.000 9 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence JOB TITLE JOB NO. SHEET NO. CALCULATED BY DATE CHECKED BY DATE Enclosure Classification Test for Enclosed Building: A building that does not qualify as open or partially enclosed. Test for Open Building:All walls are at least 80% open. Ao ≥ 0.8Ag Test for Partially Enclosed Building: Input Test Ao 0.0 sf Ao ≥ 1.1Aoi YES Ag 0.0 sf Ao > 4' or 0.01Ag NO Aoi 0.0 sf Aoi / Agi ≤ 0.20 NO Building is NOT Agi 0.0 sf Partially Enclosed Conditions to qualify as Partially Enclosed Building. Must satisfy all of the following: Ao ≥ 1.1Aoi Ao > smaller of 4' or 0.01 Ag Aoi / Agi ≤ 0.20 Where: Ao = the total area of openings in a wall that receives positive external pressure. Ag = the gross area of that wall in which Ao is identified. Aoi = the sum of the areas of openings in the building envelope (walls and roof) not including Ao. Agi = the sum of the gross surface areas of the building envelope (walls and roof) not including Ag. Reduction Factor for large volume partially enclosed buildings (Ri) : If the partially enclosed building contains a single room that is unpartitioned , the internal pressure coefficient may be multiplied by the reduction factor Ri. Total area of all wall & roof openings (Aog):0 sf Unpartitioned internal volume (Vi) :0 cf Ri = 1.00 Altitude adjustment to constant 0.00256 (caution - see code) : Altitude = 0 feet Average Air Density = 0.0765 lbm/ft3 Constant = 0.00256 10 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence JOB TITLE JOB NO. SHEET NO. CALCULATED BY DATE CHECKED BY DATE Wind Loads - MWFRS h£60' (Low-rise Buildings) Enclosed/partially enclosed only Kz = Kh (case 1) =0.86 Edge Strip (a) =6.0 ft Base pressure (qh) =24.8 psf End Zone (2a) =12.0 ft GCpi = +/-0.18 Zone 2 length =29.9 ft Wind Pressure Coefficients CASE A CASE B Surface GCpf w/-GCpi w/+GCpi GCpf w/-GCpi w/+GCpi 1 0.56 0.74 0.38 -0.45 -0.27 -0.63 2 0.21 0.39 0.03 -0.69 -0.51 -0.87 3 -0.43 -0.25 -0.61 -0.37 -0.19 -0.55 4 -0.37 -0.19 -0.55 -0.45 -0.27 -0.63 5 0.40 0.58 0.22 6 -0.29 -0.11 -0.47 1E 0.69 0.87 0.51 -0.48 -0.30 -0.66 2E 0.27 0.45 0.09 -1.07 -0.89 -1.25 3E -0.53 -0.35 -0.71 -0.53 -0.35 -0.71 4E -0.48 -0.30 -0.66 -0.48 -0.30 -0.66 5E 0.61 0.79 0.43 6E -0.43 -0.25 -0.61 Ultimate Wind Surface Pressures (psf) 1 18.3 9.4 -6.7 -15.6 2 9.7 0.7 -12.6 -21.5 3 -6.2 -15.1 -4.7 -13.6 4 -4.7 -13.6 -6.7 -15.6 5 14.4 5.4 6 -2.7 -11.6 1E 21.5 12.6 -7.4 -16.3 2E 11.1 2.2 -22.0 -31.0 3E -8.7 -17.6 -8.7 -17.6 4E -7.4 -16.3 -7.4 -16.3 5E 19.6 10.6 6E -6.2 -15.1 Parapet Windward parapet = 0.0 psf (GCpn = +1.5)Windward roof Leeward parapet = 0.0 psf (GCpn = -1.0)overhangs =17.3 psf (upward) add to windward roof pressure Horizontal MWFRS Simple Diaphragm Pressures (psf) Transverse direction (normal to L) Interior Zone: Wall 23.0 psf Roof 15.8 psf End Zone: Wall 29.0 psf Roof 19.8 psf Longitudinal direction (parallel to L) Interior Zone: Wall 17.1 psf End Zone: Wall 25.8 psf θ = 30.3 deg 11 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence JOB TITLE JOB NO. SHEET NO. CALCULATED BY DATE CHECKED BY DATE Location of MWFRS Wind Pressure Zones NOTE: Torsional loads are 25% of zones 1 - 6. See code for loading diagram. ASCE 7 -99 and ASCE 7-10 (& later) NOTE: Torsional loads are 25% of zones 1 - 4. See code for loading diagram. ASCE 7 -02 and ASCE 7-05 12 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence Key Plan Area =1 Risk Category =II Wind Speed =115 Exposure =C Importance Factor Iw =1.00 Bldg/Area Length, L (ft)=68 Bldg/Area Width, W (ft)=59.75 Edge Strip (a) (ft)=3.45 End Zone (2a) (ft)= 6.9 Transverse Direction (normal to L): Roof Type (receiving wind) =Gable End Use Only End Zone Pressures =N Interior Pressure (psf) =23.0 Roof Interior Pressure (psf) =15.8 End Zone Pressure (psf) =29.0 Roof End Zone Pressure (psf) =19.8 Windward Parapet Pressure (psf) = Leeward Parapet Pressure (psf) = Overall Structure Height,Hx (ft) =21.6 OK Vertical Distribution of Main Wind Force Resisting System Level hi (ft)di (ft)wx-interior (plf)wx-end zone (plf)wx-min (plf)wx-avg (plf)Fx (kip) Roof 9 1 260 328 181 274 18.6 Total: 274 18.6 Longitudinal Direction (parallel to L): Roof Type (receiving wind) =Gable Slope Use Only End Zone Pressures =N Interior Pressure (psf) =23.0 Roof Interior Pressure (psf) =15.8 End Zone Pressure (psf) =29.0 Roof End Zone Pressure (psf) =19.8 Windward Parapet Pressure (psf) = Leeward Parapet Pressure (psf) = Overall Structure Height,Hx (ft) =21.6 OK Vertical Distribution of Main Wind Force Resisting System Level hi (ft)di (ft)wx-interior (plf)wx-end zone (plf)wx-min (plf)wx-avg (plf)Fx (kip) Roof 9 1 310 389 181 328 19.6 Total: 328 19.6 Wind Lateral Load Vertical Distribution for MWFRS <=60' 13 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence Shear Line :1 VSEISMIC =2,200 lbs SDS = 0.419g E = 0.70 x V = 1,540 lbs S.D.C. =D WWIND =9,300 lbs F = 0.60 x W = 5,580 lbs wall segments:1 2 3 4 5 6 Roof DL (psf) =16 length (ft)25.6 Floor DL (psf) =0 height (ft)9.0 Wall DL (psf) =15 roof trib. (ft)18.3 floor trib. (ft)0.0 Distance from HD to End of Wall (in)6 Stud Wall Thickness (in)6 Shearwall Anchored Into:Concrete aspect ratio 0.4 aspect ratio factor 2w/l 1.00 Seismic F (lbs)1540 shear (plf)60 allowable shear (plf)156 suggested shearwall type 4 Mot (ft-lbs)13860 DL factor A =1.06 A x wDL (plf)452 End Post Compression(lbs)1945 DL factor B 0.54 B x wDL (plf)231 End Post Uplift for Anchor Holdowns (lbs)0 End Post Uplift for Straps (lbs)0 Wind F (lbs)5580 shear (plf)218 allowable shear (plf)218 suggested shearwall type 4 Mot (ft-lbs)50220 wDL (plf)427 End Post Compression(lbs)3264 DL factor C 0.60 C x wDL (plf)256 End Post Uplift for Anchor Holdowns (lbs)0 End Post Uplift for Straps (lbs)0 Maximum End Post Compression (lbs)3264 Recommended Minimum End Post for Compression (2) 2x6 Controlling Anchor Holdown Uplift (lbs)0 Recommended Anchor Holdown Anchor at Midwall Anchor at Corner Anchor at Endwall Controlling Strap Holdown Uplift (lbs)0 Recommended Strap Holdown at Midwall Recommended Strap Holdown at Corner Recommended Strap Holdown at Endwall Line 1, Use:SW4 Wood Framing: Douglas-Fir OR Southern Pine Wood Stud Shear Walls 2015 INTERNATIONAL BUILDING CODE (IBC) 14 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence Shear Line :2 VSEISMIC =1,100 lbs SDS = 0.419g E = 0.70 x V = 770 lbs S.D.C. =D WWIND =4,650 lbs F = 0.60 x W = 2,790 lbs wall segments:1 2 3 4 5 6 Roof DL (psf) =16 length (ft)31.1 Floor DL (psf) =0 height (ft)9.0 Wall DL (psf) =15 roof trib. (ft)18.3 floor trib. (ft)0.0 Distance from HD to End of Wall (in)6 Stud Wall Thickness (in)6 Shearwall Anchored Into:Concrete aspect ratio 0.3 aspect ratio factor 2w/l 1.00 Seismic F (lbs)770 shear (plf)25 allowable shear (plf)156 suggested shearwall type 4 Mot (ft-lbs)6930 DL factor A =1.06 A x wDL (plf)452 End Post Compression(lbs)1611 DL factor B 0.54 B x wDL (plf)231 End Post Uplift for Anchor Holdowns (lbs)0 End Post Uplift for Straps (lbs)0 Wind F (lbs)2790 shear (plf)90 allowable shear (plf)218 suggested shearwall type 4 Mot (ft-lbs)25110 wDL (plf)427 End Post Compression(lbs)2100 DL factor C 0.60 C x wDL (plf)256 End Post Uplift for Anchor Holdowns (lbs)0 End Post Uplift for Straps (lbs)0 Maximum End Post Compression (lbs)2100 Recommended Minimum End Post for Compression (2) 2x6 Controlling Anchor Holdown Uplift (lbs)0 Recommended Anchor Holdown Anchor at Midwall Anchor at Corner Anchor at Endwall Controlling Strap Holdown Uplift (lbs)0 Recommended Strap Holdown at Midwall Recommended Strap Holdown at Corner Recommended Strap Holdown at Endwall Line 2, Use:SW4 Wood Stud Shear Walls 2015 INTERNATIONAL BUILDING CODE (IBC) Wood Framing: Douglas-Fir OR Southern Pine 15 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence Shear Line :A VSEISMIC =2,200 lbs SDS = 0.419g E = 0.70 x V = 1,540 lbs S.D.C. =D WWIND =8,450 lbs F = 0.60 x W = 5,070 lbs wall segments:1 2 3 4 5 6 Roof DL (psf) =16 length (ft)5.0 4.9 Floor DL (psf) =0 height (ft)9.0 9.0 Wall DL (psf) =15 roof trib. (ft)2.0 2.0 floor trib. (ft)0.0 0.0 Distance from HD to End of Wall (in)6 6 Stud Wall Thickness (in)6 6 Shearwall Anchored Into:Concrete Concrete aspect ratio 1.8 1.8 aspect ratio factor 2w/l 1.00 1.00 Seismic F (lbs)778 762 shear (plf)156 156 allowable shear (plf)156 156 suggested shearwall type 4 4 Mot (ft-lbs)7000 6860 DL factor A =1.06 1.06 A x wDL (plf)177 177 End Post Compression(lbs)2105 2101 DL factor B 0.54 0.54 B x wDL (plf)90 90 End Post Uplift for Anchor Holdowns (lbs)1355 1364 End Post Uplift for Straps (lbs)1248 1254 Wind F (lbs)2561 2509 shear (plf)512 512 allowable shear (plf)532 532 suggested shearwall type 6 6 Mot (ft-lbs)23045 22585 wDL (plf)167 167 End Post Compression(lbs)5200 5195 DL factor C 0.60 0.60 C x wDL (plf)100 100 End Post Uplift for Anchor Holdowns (lbs)4996 5016 End Post Uplift for Straps (lbs)4601 4611 Maximum End Post Compression (lbs)5200 5195 Recommended Minimum End Post for Compression (2) 2x6 (2) 2x6 Controlling Anchor Holdown Uplift (lbs)4996 5016 Recommended Anchor Holdown HTT5 HTT5 Anchor at Midwall SSTB20 SSTB20 Anchor at Corner SSTB24 SSTB24 Anchor at Endwall SSTB24 SSTB24 Controlling Strap Holdown Uplift (lbs)4601 4611 Recommended Strap Holdown at Midwall STHD14 STHD14 Recommended Strap Holdown at Corner STHD14 STHD14 Recommended Strap Holdown at Endwall -- -- Line A SW6 SW6 Wood Stud Shear Walls 2015 INTERNATIONAL BUILDING CODE (IBC) Wood Framing: Douglas-Fir OR Southern Pine 16 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence Shear Line :C VSEISMIC =250 lbs SDS = 0.419g E = 0.70 x V = 175 lbs S.D.C. =D WWIND =1,000 lbs F = 0.60 x W = 600 lbs wall segments:1 2 3 4 5 6 Roof DL (psf) =16 length (ft)3.0 3.0 Floor DL (psf) =0 height (ft)9.0 9.0 Wall DL (psf) =15 roof trib. (ft)2.0 2.0 floor trib. (ft)0.0 0.0 Distance from HD to End of Wall (in)6 6 Stud Wall Thickness (in)6 6 Shearwall Anchored Into:Concrete Concrete aspect ratio 3.0 3.0 aspect ratio factor 2w/l 0.67 0.67 Seismic F (lbs)88 88 shear (plf)29 29 allowable shear (plf)173 173 suggested shearwall type 5 5 Mot (ft-lbs)788 788 DL factor A =1.06 1.06 A x wDL (plf)177 177 End Post Compression(lbs)667 667 DL factor B 0.54 0.54 B x wDL (plf)90 90 End Post Uplift for Anchor Holdowns (lbs)neglect neglect End Post Uplift for Straps (lbs)neglect neglect Wind F (lbs)300 300 shear (plf)100 100 allowable shear (plf)243 243 suggested shearwall type 5 5 Mot (ft-lbs)2700 2700 wDL (plf)167 167 End Post Compression(lbs)1218 1218 DL factor C 0.60 0.60 C x wDL (plf)100 100 End Post Uplift for Anchor Holdowns (lbs)963 963 End Post Uplift for Straps (lbs)832 832 Maximum End Post Compression (lbs)1218 1218 Recommended Minimum End Post for Compression (2) 2x6 (2) 2x6 Controlling Anchor Holdown Uplift (lbs)963 963 Recommended Anchor Holdown LTT20B LTT20B Anchor at Midwall 1/2" Anchor 1/2" Anchor Anchor at Corner 1/2" Anchor 1/2" Anchor Anchor at Endwall 1/2" Anchor 1/2" Anchor Controlling Strap Holdown Uplift (lbs)832 832 Recommended Strap Holdown at Midwall LSTHD8 LSTHD8 Recommended Strap Holdown at Corner LSTHD8 LSTHD8 Recommended Strap Holdown at Endwall LSTHD8 LSTHD8 Line C SW5 SW5 Wood Stud Shear Walls 2015 INTERNATIONAL BUILDING CODE (IBC) Wood Framing: Douglas-Fir OR Southern Pine 17 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence Shear Line :B VSEISMIC =1,000 lbs E = 0.70 x V = 700 lbs WWIND =5,550 lbs F = 0.60 x W = 3,330 lbs Consider Drift Limits? :Yes C&C Wall Wind Pressure, p =35 psf p(ASD) =0.6 x p = 21.0 psf length(in)20 20 opening height(ft)7.3 7.3 plate height(ft)9 9 Opening width (ft)10 10 Wall Thickness(in)6 6 header depth (in)11.875 11.875 Seisimic Allowable Shear (lb)1,201 1,201 Wind Allowable Shear (lb)1,681 1,681 Vertical Strap Load (lb)1,636 1,636 Vertical Strap MSTC40 MSTC40 Vertical Strap Capacity (lb)3,080 3,080 OK OK System Totals Seisimic Allowable Shear (lb) = 2,401 OK Wind Allowable Shear (lb) = 3,362 OK Portal Frame with Hold Downs 2015 IBC and APA TT-100F Wood Framing: Douglas-Fir or Souhern Pine portal frame wall segments 18 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence 19 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence HTT5 HTT5 HTT5 HTT5 6 6 5 5 5 5 PF PF STHD14STHD14 STHD14STHD14 3" x 11 1/4" MIN. HEADER SIZE. EXTEND HEADER OVER THE TOP OF EACH PORTAL FRAME PIER, SEE DETAIL. 716" APA RATED SHEATHING SEE PORTAL FRAME DETAIL SEE PORTAL FRAME DETAIL (1) 58"Ø MIN W/ 14"x3"x3" PLATE WASHERSPF 716" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 58"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 716" APA RATEDSHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 58"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 5 6. SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT PLANWORK 20 of 20 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : KBB FSE10/28/20IF20-395Coulter Residence T3 5 PO R T A L - F R A M E TD 3 5 NO S C A L E KE Y N O T E S : 1. 7 16 " A P A R A T E D S H E A T H I N G 2. D B L 2 x T O P P L A T E 3. 8d N A I L I N G A T 3 " G R I D O N B E A M A S SH O W N 4. WO O D H E A D E R P E R P L A N ( M I N 3" x 1 1 1 4 ") 5. ST R A P T R I M M E R T O J A C K - S T U D WIT H M S T C 4 0 ( O P P O S I T E SH E A T H I N G ) 6. 2x W O O D F R A M I N G 7. MIN 2 " x 4 " F R A M I N G W / M I N 3 8 " W O O D SH E A T H I N G W / 8 d N A I L S A T 3 " O . C . AL L F R A M I N G 8. 2x B L O C K I N G A T P A N E L S P L I C E S WIT H I N M I D D L E 2 4 " O F P O R T A L HE I G H T . 1 R O W O F 8 d N A I L S A T 3 " O.C . E A C H P A N E L E D G E 9. TR I M M E R ( S ) A N D K I N G S T U D ( S ) P E R PL A N 10 . HO L D O W N ( E M B E D D E D I N CO N C R E T E A N D N A I L E D T O FR A M I N G ) 11 . (2 ) 2 x S O L E P L A T E W / ( 1 ) 5 8"Ø AN C H O R B O L T 12 . 2 R O W S O F 1 6 d N A I L S A T 3 " O . C . 13 . CO N C R E T E W A L L 14 . FL O O R F R A M I N G , S E E P L A N 15 . CO N T 2 x P T S O L E P L A T E 7 2 5 5 5 2 1 11 1 8 10 13 8 11 5 9 3 6 4 3 12 10 10 10 10 8 10 3 14 2' T O 1 8 ' R O U G H W I D T H O F O P E N I N G F O R S I N G L E O R D O U B L E P O R T A L 1 2 ' M A X T O T A L W A L L H E I G H T 1 0 ' M A X H E I G H T P O N Y W A L L H E I G H T EX T E N T O F H E A D E R W / D O U B L E P O R T A L F R A M E S ( 2 B R A C E D W A L L P A N E L S ) EX T E N T O F H E A D E R W / S I N G L E P O R T A L F R A M E ( 1 B R A C E D W A L L P A N E L S ) 15