HomeMy WebLinkAboutFIRE REVIEW - Teton Professional Park - Trejo StT_!'��ih"�t'� o P.O. Box 280 luniv12 North Center Street p Rexburg, Idaho 83440 Phone(208)359-3020 STATE OF IDAHO Fax (208) 359-3022 e-mail rexburg@srv.net REXB URG-JL4DISON COUNTY EMERGENCY SERVICES 26 NORTH CENTER STREET REXB URG, IDAHO 83440 208-359-3010 208-359-3006 FAX 2000 International Fire Code Plan Date: 11-14-03 Plan Review Review Date: 01-05-04 Building Name: TETON PROFESSIONAL PARK Building Address: TREJO STREET AND HIGHWAY 191 Stories: ONE Type of Construction: V -B Occupancy Classification: B Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 5975 SQUARE FEET 1. Required Fire Flow (Appendix B): 2000 GPM/TWO HOURS Comments: FIRE FLOW MAY BE REDUCED IF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IS INSTALLED. 2_ Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: EXISTING ON TREJO AND HIGHWAY 191, ONE PROPOSED Fire Hydrant Flows: EXISTING OKAY, PROPOSED UNKOWN Fire Flow Test Location: N/A Fire Flow Supplied By: N/A �7"fi �A"trk , !'fir Ma+i�YMlrli�v�!�Ilylf lvpr i 74 {� W 7.. .H�'N, !' ni. ruv. rs'fl.w tli" Ntana,:MiW!w wti5S4H'rr r.6!WN7' .,., r. n ��• r •.,; �.�. ,.. .r ��-r�.� , ..,.. ,,, .>"i.t�r. ,�d .: , �..a � , . ,f :.. , �,.u, (*' .fYf�;"1 YW�• 1.�(W t 4!.. � ;� n+m+^�t to 4J i ',Hrn ..werM� 4ri ,um wU~'uw :x. t .aw+rsr to • � ,a' uw ,., .,._.. ,......d . ...:. _.. ..:...� "�9.�p'i,11P'�d�"k3�1,t�"�`��'�,'�„'s��° -�.. _.. �R, g _s,+, hY- x��'7 `�3I�r�,�4 , IK` ��,11''�'�,•���r,�,iil�"`�r��?�t.'..�t�,�'� ,,,sl��ws�!,'�.r.; :::1.:,�24Y�'���5>om!; Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: NO Water Supply Comments: PROPOSED HYDRANT NEEDS TO BE MOVED CLOSER TO THE ENTRANCE, PREFERABLY ON THE WEST SIDE OF THE ENTRANCE. PLEASE PROVIDE ENGINEER'S CALCULATIONS OF WATER FLOW FOR PROPOSED HYDRANT. 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: YES Complete Road Acceptable: YES Comments- NONE Length: YES Surface: YES 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Continents: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required- YES Location shown: NO Type provided acceptable: NOT SHOWN Comments: PROVIDE A MINIMUM OF 2A10BC FIRE EXTINGUISHERS WITHIN TRAVEL DISTANCES FOR EACH OCCUPANCY. 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: Sprinkler system monitoring (Section 907) required: NO Comments: 7. Standpipes (Section 905) required: NO Type required: Comments: f, . 8. Ventilating hood and duct fire extinguisher system (Section 609) required: NO Type being provided: Automatic fuel shut-off required: Portable fire extinguisher shown: Comments: 9. Fire alarm systems (Section 907) required: NO Type of system required: Manual: Automatic: Both: Type of system being provided: Manual: Automatic: Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices:, Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: 10. Other corrections that are required by special occupancy or conditions: Plans as submitted are acceptable: NO Plans checked by: CHRIS HUSKINSON Date: 1-5-04 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X