FIRE ALARM INSPECTION AND TESTING REPORT
Testing performed in accordance with applicable NFPA 72 Standards / By NICET Certified Technicians
Building occupied as
Address of Building.
5 3
Owner /Manager: Name & Number
Name of Tester Cy //* *� Date of Inspection 16 Z
Type of Inspection A tjt,1 I&A i-- Notification of Testing G 5
Control Panel Manufacturer & ModelG��
# of Zones: �� SLC Loops: NAC's - FACP: _� FCPS:_ Total NAC's:
System should be tested on Standby (battery power) for 30 min. prior to Battery Test.
Battery Inspection
RADIO
FACP
FCPS1 FCPS2 FCPS3
Location 601%j7,5
N/A
g273 06M { r`avL-.••"""""
Battery Voltage
17
7 12 12
Amp Hour 2„
Operating Instructions at Panel X
Newest Record posted at Panel X
Date on Battery 1
/0 -2-01
Q -- ZQ1JV „ 2.0. 10 --IQ - ci /Q - Q
FACP Inspection
Yes No N/A
# of Units Satisfactory: Satisfactory:
Tested Yes No
Yes
No
N/A
Key to Panel Available
All circuits checked for
electrical supervision
Dialer Communicator
Operating Instructions at Panel X
Newest Record posted at Panel X
All functions and buttons
properly
_.
7-
Smoke Detectors
circuit Breaker marked Redwork
circuit Breaker Panel: #
Does Alarm system meet
audibility standards
}(
Duct Detectors
Trouble Signal with AC Power off
System operates satisfactory on
standby power at max load
Control Panel checks made per
manufacturer's instruction
X
Flow Switches
All signals operate on AC power
All interfaced equipment operates
(Elevators, Fans, Dampers)
Tamper Switches
All LED's Illuminate X
Name of Monitoring Company: AV Mt' 6 A k R 6 Account # A LO ( Z J
Communication Verified: N/A
Equipment Tested
Type of Equipment
# of Units Satisfactory: Satisfactory:
Tested Yes No
N/A # of Units
in Bldg.
FCPS Power Booster
%'
Annunciators
Dialer Communicator
Horns, Strobes, Bells,
Chimes, Speakers, Etc.
_.
7-
Smoke Detectors
1 �r
Heat Detectors
}(
Duct Detectors
Pull Stations
Flow Switches
Tamper Switches
Low/High Air Switches
1*X
Antifreeze Tamper
Ansul System
Temp Sensor
Problems Found:
Corrections Made:
Interfaced # of Units Satisfactory: Satisfactory: N/A # of Units
Equipment Tested Yes No in Bldg.
Ventilation Controls
Elev. Recall Prim %
Elev. Recall Sec {
Elev. Recall Shunt
Access Control Door t`
Release Failsafe
Auto Release
Door Holders
Halon System
Smoke Control
PIV Valve i
Beam Detector
CO Detector
This is to certify that this Fire Alarm has been properly Tested and Inspected for liability to cover the items listed in this report, according to
Manufacturers Recommendation. _
Signature of Fire Marshal: }=-� t_ \�' Date: 10 ,:y ' z -o
Signature of Owner or representative: Date:
Signature of Certified Tester: .-rf "� � Date: 0<1-2f-2000
Agency: Omni Security Systems, Inc. - P. O. Box 309 - Rigby, ID 83442 - Office 208-745-1020 - Fax: 208-745-1564