Loading...
HomeMy WebLinkAboutREVIEW REPORT - 19-00364 - East Idaho Credit Union - New Building-ON CITY 0 F REXBURG America's Family Community Community development Department 35 North 11t East Rexburg, ID 83440 Permit Technician (208) 372-2341 Inspection Hotline (208) 372-2344 Current Building Review Status: REVISIONS Permit Details Application Number; 19-00$64 East Idaho Credit Union - New Building 310 N 2nd E Permit Review Status Plan Reviews Still in Progress Fire Department Review - Site Plan Fire Sprinkler Review Electrical Review Public Works Review - Site Pian Planning and Zoning Review - Site Plan Building - Commercial Application Received Date: 06/19/2019 Application Approved Date: o7/08/2019 Application Approved Status: ACCEPTED Status Fire Alarm Review of Plajrl Reviews N/A corenleted 07/08/2019 Electrical Review REVISIONS 07/08/2019 Plumbing Review COMPLETED 07/09/2019 HVAC Review COMPLETED 07/09/2019 Public Works Review - Site Plan REVISIONS 07/09/2019 Planning and Zoning Review - Site Plan REVISIONS 07/15/2019 Building Review REVISIONS 07/15/2019 Pian Review Details Building Review Status: REVISIONS Review Date: 07/15/2019 Reviewed By: Quinton Owens quinton.owens@rexburg,org *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! 0 a f O Service Facilities comply with IBC 1109.12 Please identify accessible service Counter space REVISIONS per IBC 1109.12.3 & Al 17.1 sect 904.3 *Revisions Response : All accessible needs for customers are provided by personnel in private offices Ventilation is provided as per IBC Section 1203 i Crawl space ventilation? See also notes on crawl I REVISIONS spaces in flood hazard area. *Revisions Response: See revised plan showing flood/ventilation vents Building Complies with IECC (IBC 1301) i Submitted COMcheck has lighting certificate but I it does not have thermal energy report. I REVISIONS Foundation insulation at interior slab on grade? "Revisions Response: See attache¢ COMcheck See revised A3 302 Building or Structures located in Rood Area have Flood vents are required if crawl space floor is i Flood Certificate per 1612.5 less than 1 foot above base flood elevation, and REVISIONS the crawispace floor cannot be more than 2 feet below lowest adjacent grade (see FEMA TB -11). * Nobe: Building is in Hood zone and will require an elevation certificate. Pians show finished floor elevation at 4870.7 ft. "Revisions Response : See revised plan showing flood vents Approval of plans does not constitute approval of variance from code Page 1 of 2 CITY OF RMURG Ow------ -- America's Family Community Special Inspection Contractor is identified (IBC 1704.2.1) 'Revisions Response Who is the special inspection contractor? Building Review (Continued) REVISIONS Wood Fram. design. by lice. Eng. and meets. N/A — reqs. IBC Chp. 23 or Conv. Li -Frame Concealed spaces are fireblocked/dratistopped Firebiockinr IBC 718 witl be per Section 718 g approved based j COMPLETED on inspection. Special Inspections are required as per IBC With the previous building removed, structural I COMPLETED Chapter ll fill for new building shall also have compaction tests done. Approval of plans does not constitute approval of variance from code Page 2 of 2