PROJECT INFORMATION - 20-00858 - 727 S 2315 W - New SFR
Load Short Form Job:SF2B13 Date:8/5/2020 By:Vince Byram Plan:ATHENS B Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information For:Cody Puzey, Karthcner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information HtgClgInfiltration Outsidedb(°F)-689MethodSimplified Insidedb(°F)7075Construction qualitySemi-tight DesignTD(°F)7614Fireplaces0 Daily range-H Inside humidity (%)5050 Moisture difference (gr/lb)62-31 HEATING EQUIPMENTCOOLING EQUIPMENT MakeLennoxMakeLennox TradeLENNOXTradeLENNOX ModelML195UH070XP36B-*Cond13ACXN018-230A** AHRI ref4805339CoilCH35-30B+EL195UH030XE24B+TDR+TXV AHRI ref10245916 Efficiency95 AFUEEfficiency12.5 EER, 15 SEER Heating input66000BtuhSensible cooling18000Btuh Heating output64000BtuhLatent cooling0Btuh Temperature rise71°FTotal cooling18000Btuh Actual air flow975cfmActual air flow600cfm Air flow factor0.043cfm/BtuhAir flow factor0.058cfm/Btuh Static pressure0.70in H2OStatic pressure0.70in H2O Space thermostatLoad sensible heat ratio1.00 ROOM NAMEAreaHtg loadClg loadHtg AVFClg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room120134742011148116 Room2861021124447 Room3551532137658 Room4103746152329 Room51664098168217597 Room65058572254 Room714617325477432 Room879697035693413328 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 1 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Entire Housed16022289110418975600 Other equip loads8609653 Equip. @0.94RSM10407 Latent cooling0 TOTALS16023149910407975600 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 2 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Building Analysis Job:SF2B13 Date:8/5/2020 By:Vince Byram Plan:ATHENS B Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information For:Cody Puzey, Karthcner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:Indoor:HeatingCooling Idaho Falls, ID, USIndoortemperature(°F)7075 Elevation:4741ftDesignTD(°F)7614 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.5-31.5 Infiltration: Drybulb(°F)-689 Dailyrange(°F)-34(H) MethodSimplified Wetbulb(°F)-60 Construction qualitySemi-tight Wind speed (mph)15.07.5 Fireplaces0 Heating ComponentBtuh/ft²Btuh% of load Walls4.9713822.7 Humidification Walls Glazing22.8355211.3 Doors11.44591.5 Ceilings1.524357.7 Ventilation Floors3.13.1491915.6 Infiltration2.7438813.9 Ducts00 Glazing Piping00 Humidification506516.1 Infiltration Other Ventilation354411.3 Ceilings Adjustments0 Floors Total31499100.0 Cooling ComponentBtuh/ft²Btuh% of load WallsVentilation Walls0.56866.2 Glazing38.0592053.5 InternalGains Doors2.81121.0 Ceilings0.8134512.2 Floors000 Infiltration0.34353.9 Infiltration Ducts00 Ventilation6535.9 Internal gains192017.3 Glazing Ceilings Blower00 Other Adjustments0 Total11071100.0 Latent Cooling Load = 0 Btuh OverallU-value=0.050Btuh/ft²-°F Data entries checked. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 1 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Component Constructions Job:SF2B13 Date:8/5/2020 By:Vince Byram Plan:ATHENS B Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information For:Cody Puzey, Karthcner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:Indoor:HeatingCooling Idaho Falls, ID, USIndoortemperature(°F)7075 Elevation:4741ftDesignTD(°F)7614 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.5-31.5 Infiltration: Drybulb(°F)-689 Dailyrange(°F)-34(H) MethodSimplified Wetbulb(°F)-60 Construction qualitySemi-tight Wind speed (mph)15.07.5 Fireplaces0 Construction descriptions OrAreaU-valueInsul RHtg HTMLossClg HTMGain ft²Btuh/ft²-°Fft²-°F/BtuhBtuh/ft²BtuhBtuh/ft²Btuh Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum n4650.06521.04.9422970.47221 e2240.06521.04.9411050.47106 board int fnsh, 2"x6" wood frm, 16" o.c. stud s4950.06521.04.9424450.47235 w2610.06521.04.9412900.47124 all14450.06521.04.9471380.47686 Partitions (none) Windows 61C: 61C; NFRC rated (SHGC=0.33); 6.67 ft head htn300.300022.868410.5314 e300.300022.868435.11052 w960.300022.8218435.13361 all1560.300022.8355230.34727 Doors metal: Door, mtl pur core typee400.15010.511.44592.78112 Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 16020.02050.01.5224350.841345 gypsum board int fnsh Floors 22B-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 1820.35510.027.0491900 edge ins, carpet flr fnsh 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 1 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Project Summary Job:SF2B13 Date:8/5/2020 By:Vince Byram Plan:ATHENS B Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information For:Cody Puzey, Karthcner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Weather:Idaho Falls, ID, US Winter Design ConditionsSummer Design Conditions Outside db-6°FOutside db89°F Inside db70°FInside db75°F Design TD76°FDesign TD14°F Daily rangeH Relative humidity50% Moisture difference-31gr/lb Heating SummarySensible Cooling Equipment Load Sizing Structure22891BtuhStructure10418Btuh Ducts0BtuhDucts0Btuh Central vent (50 cfm)3544BtuhCentral vent (50 cfm)653Btuh Outside airOutside air Humidification5065BtuhBlower0Btuh Piping0Btuh Equipment load31499BtuhUse manufacturer's datan Rate/swing multiplier0.94 Infiltration Equipment sensible load10407Btuh Latent Cooling Equipment Load Sizing MethodSimplified Construction qualitySemi-tight Fireplaces0Structure195Btuh Ducts0Btuh Central vent (50 cfm)-907Btuh HeatingCooling Outside air Area(ft²)16021602Equipment latent load0Btuh Volume(ft³)1441614416 Equipment Total Load (Sen+Lat) Air changes/hour0.260.1410407Btuh Equiv. AVF (cfm)6234Req. total capacity at 1.00 SHR0.9ton Heating Equipment SummaryCooling Equipment Summary MakeLennoxMakeLennox TradeLENNOXTradeLENNOX ModelML195UH070XP36B-*Cond13ACXN018-230A** AHRI ref4805339CoilCH35-30B+EL195UH030XE24B+TDR+TXV AHRI ref10245916 Efficiency95 AFUEEfficiency12.5 EER, 15 SEER Heating input66000BtuhSensible cooling18000Btuh Heating output64000BtuhLatent cooling0Btuh Temperature rise71°FTotal cooling18000Btuh Actual air flow975cfmActual air flow600cfm Air flow factor0.043cfm/BtuhAir flow factor0.058cfm/Btuh Static pressure0.70in H2OStatic pressure0.70in H2O Space thermostatLoad sensible heat ratio1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 1 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S AED Assessment Job:SF2B13 Date:8/5/2020 By:Vince Byram Plan:ATHENS B Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information For:Cody Puzey, Karthcner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:Indoor:HeatingCooling Idaho Falls, ID, USIndoortemperature(°F)7075 Elevation:4741ftDesignTD(°F)7614 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.5-31.5 Infiltration: Drybulb(°F)-689 Dailyrange(°F)-34(H) Wetbulb(°F)-60 Wind speed (mph)15.07.5 Test for Adequate Exposure Diversity HourlyGlazingLoad 7,000 6,000 5,000 4,000 3,000 2,000 1,000 0 891011121314151617181920 HourofDay HourlyAverageAED limit Maximum hourly glazing load exceeds average by 59.9%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 1193 Btuh (PFG - 1.3*AFG) 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 1 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:SF2B13 Date:8/5/2020 By:Vince Byram Modern Plumbing Heating and Electric Plan:ATHENS B 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1Room nameEntire HouseRoom1 2Exposed wall182.3ft28.5ft 3Room height9.0ftd9.0ftheat/cool 4Room dimensions12.8x15.7ft 5Room area1601.8ft²201.1ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.944.940.470.4749546522972210000 .GG61C61C0.3000.300nn22.8022.8010.4710.473006843140000 .WW12F-0sw12F-0sw0.0650.065ee4.944.940.470.4729422411051060000 .GG61C61C0.3000.300ee22.8022.8035.0835.0830068410520000 11DDmetalmetal0.1500.150ee11.4011.402.782.7840404591120000 WW12F-0sw12F-0sw0.0650.065ss4.944.940.470.47495495244523514114169767 WW12F-0sw12F-0sw0.0650.065ww4.944.940.470.4735726112901241169144743 GG61C61C0.3000.300ww22.8022.8035.0835.0896021843361250570877 CC16B-50ad16B-50ad0.0200.020--1.521.520.840.841602160224351345201201306169 FF22B-10cpm22B-10cpm0.3550.355--26.9826.980.000.00160218249190201297690 6c) AED excursion1193328 Envelope loss/gain18503806327881483 12a)Infiltration438843568668 b)Room ventilation0000 13Internal gains:Occupants @23023049202460 Appliances/other10000 Subtotal (lines 6 to 13)228911041834742011 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal228911041834742011 15Duct loads0%0%00-0%0%00 Total room load228911041834742011 Air required (cfm)Air required (cfm)975600148116 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 1 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:SF2B13 Date:8/5/2020 By:Vince Byram Modern Plumbing Heating and Electric Plan:ATHENS B 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1Room nameRoom2Room3 2Exposed wall9.3ft15.2ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions9.2x9.3ft9.2x6.0ft 5Room area85.6ft²55.0ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.944.940.470.4700000000 .GG61C61C0.3000.300nn22.8022.8010.4710.4700000000 .WW12F-0sw12F-0sw0.0650.065ee4.944.940.470.470000838340839 .GG61C61C0.3000.300ee22.8022.8035.0835.0800000000 11DDmetalmetal0.1500.150ee11.4011.402.782.7800000000 WW12F-0sw12F-0sw0.0650.065ss4.944.940.470.47848441540545426726 WW12F-0sw12F-0sw0.0650.065ww4.944.940.470.4700000000 GG61C61C0.3000.300ww22.8022.8035.0835.0800000000 CC16B-50ad16B-50ad0.0200.020--1.521.520.840.8486861307255558446 FF22B-10cpm22B-10cpm0.3550.355--26.9826.980.000.00869252055154090 6c) AED excursion-10-10 Envelope loss/gain7971021167100 12a)Infiltration2252236536 b)Room ventilation0000 13Internal gains:Occupants @2302300000 Appliances/other00 Subtotal (lines 6 to 13)10211241532137 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal10211241532137 15Duct loads-0%0%00-0%0%00 Total room load10211241532137 Air required (cfm)Air required (cfm)447658 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 2 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:SF2B13 Date:8/5/2020 By:Vince Byram Modern Plumbing Heating and Electric Plan:ATHENS B 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1Room nameRoom4Room5 2Exposed wall4.8ft34.7ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions1.0x102.5ft1.0x165.7ft 5Room area102.5ft²165.7ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.944.940.470.47000012212260058 .GG61C61C0.3000.300nn22.8022.8010.4710.4700000000 .WW12F-0sw12F-0sw0.0650.065ee4.944.940.470.474424117111178743041 .GG61C61C0.3000.300ee22.8022.8035.0835.0800003006841052 11DDmetalmetal0.1500.150ee11.4011.402.782.782020226550000 WW12F-0sw12F-0sw0.0650.065ss4.944.940.470.470000747436335 WW12F-0sw12F-0sw0.0650.065ww4.944.940.470.4700000000 GG61C61C0.3000.300ww22.8022.8035.0835.0800000000 CC16B-50ad16B-50ad0.0200.020--1.521.520.840.8410310315686166166252139 FF22B-10cpm22B-10cpm0.3550.355--26.9826.980.000.0010351300166359350 6c) AED excursion-1244 Envelope loss/gain62914132641369 12a)Infiltration1161283483 b)Room ventilation0000 13Internal gains:Occupants @230230001230 Appliances/other00 Subtotal (lines 6 to 13)74615240981682 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal74615240981682 15Duct loads-0%0%00-0%0%00 Total room load74615240981682 Air required (cfm)Air required (cfm)32917597 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 3 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:SF2B13 Date:8/5/2020 By:Vince Byram Modern Plumbing Heating and Electric Plan:ATHENS B 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1Room nameRoom6Room7 2Exposed wall5.3ft13.0ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions9.3x5.3ft1.0x146.2ft 5Room area49.8ft²146.2ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.944.940.470.4748482372311710250448 .GG61C61C0.3000.300nn22.8022.8010.4710.470000150342157 .WW12F-0sw12F-0sw0.0650.065ee4.944.940.470.4700000000 .GG61C61C0.3000.300ee22.8022.8035.0835.0800000000 11DDmetalmetal0.1500.150ee11.4011.402.782.7800000000 WW12F-0sw12F-0sw0.0650.065ss4.944.940.470.4700000000 WW12F-0sw12F-0sw0.0650.065ww4.944.940.470.4700000000 GG61C61C0.3000.300ww22.8022.8035.0835.0800000000 CC16B-50ad16B-50ad0.0200.020--1.521.520.840.8450507642146146222123 FF22B-10cpm22B-10cpm0.3550.355--26.9826.980.000.005051440146133510 6c) AED excursion-6-42 Envelope loss/gain457591419286 12a)Infiltration1281331331 b)Room ventilation0000 13Internal gains:Occupants @230230001230 Appliances/other00 Subtotal (lines 6 to 13)585721732547 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal585721732547 15Duct loads-0%0%00-0%0%00 Total room load585721732547 Air required (cfm)Air required (cfm)2547432 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 4 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:SF2B13 Date:8/5/2020 By:Vince Byram Modern Plumbing Heating and Electric Plan:ATHENS B 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com 1Room nameRoom8 2Exposed wall71.5ft 3Room height9.0ftheat/cool 4Room dimensions1.0x796.0ft 5Room area796.0ft² TyConstructionU-valueOrHTMArea(ft²)LoadAreaLoad number(Btuh/ft²-°F)(Btuh/ft²)orperimeter(ft)(Btuh)orperimeter HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6W12F-0sw0.065n4.940.4720919495692 .G61C0.300n22.8010.47150342157 .W12F-0sw0.065e4.940.47513115115 .G61C0.300e22.8035.080000 11Dmetal0.150e11.402.78202023357 W12F-0sw0.065s4.940.4714314370468 W12F-0sw0.065w4.940.4724217184381 G61C0.300w22.8035.0871016142484 C16B-50ad0.020-1.520.847967961210669 F22B-10cpm0.355-26.980.007967219290 6c) AED excursion901 Envelope loss/gain79824522 12a)Infiltration1721171 b)Room ventilation00 13Internal gains:Occupants @23000 Appliances/other1000 Subtotal (lines 6 to 13)97035693 Less external load00 Less transfer00 Redistribution00 14Subtotal97035693 15Duct loads-0%0%00 Total room load97035693 Air required (cfm)413328 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-26 13:05:19 Right-Suite®Universal201919.0.13RSU20477 Page 5 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S N main 74 cfm 74 cfm103 cfm 103 cfm Sppn2 295 cfm 6 " 6 "6 " 6 " Sppn9 44 cfm Sppn3 103 cfm 2-14x3.25 32 cfm 6 " 6 " Sppn5 6 " 12 " 12 " 12 " 9 " 12 " Sppn4 12 "12 " 6 " Sppn: 6 " 200 cfm Sppn8 65 cfm 15 " 2-14x3.25 74 cfm 6 " 280 cfm 6 " 6 " 14x3.25 Sppn7 6 " 25 cfm 87 cfm 103 cfm 199 cfm Sppn6 87 cfm Job #: SF2B13 Scale: 1 : 80 Modern Plumbing Heating and Electric Performed by Vince Byram for: Page 1 Cody Puzey 3939 E 240 NRight-Suite®Universal2019 3758 Yellowstones Hwy Rigby, Id 8344219.0.13 RSU20477 Idaho Falls, Id 83401 Phone: 208-529-2116 Phone: 208-745-7021 Fax: 208-745-73292020-Oct-26 13:05:30 Vince@modernphe.com...try\\Wrightsoft\\SF2B13 athens.rup Duct System Summary Job:SF2B13 Date:8/5/2020 By:Vince Byram Plan:ATHENS B Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modernphe.com Project Information For:Cody Puzey, Karthcner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 HeatingCooling External static pressure0.70in H2O0.70in H2O Pressure losses0.34in H2O0.34in H2O Available static pressure0.36in H2O0.36in H2O Supply / return available pressure0.186 / 0.174in H2O0.186 / 0.174in H2O Lowest friction rate0.078in/100ft0.078in/100ft Actual air flow975cfm600cfm Total effective length (TEL)464ft Supply Branch Detail Table DesignHtgClgDesignDiamH x WDuctActualFtg.Eqv Name(Btuh)(cfm)(cfm)FR(in)(in)MatlLn (ft)Ln (ft)Trunk Room1 h173774580.1116.00x0ShMt38.2130.0st2 Room1-A h173774580.1106.00x0ShMt29.8140.0st2 Room2 h10214470.1076.00x0ShMt23.5150.0st2B Room3 h15326580.1216.00x0ShMt14.5140.0st2A Room4 h7463290.1096.00x0ShMt10.3160.0st1 Room5 h204987480.0916.00x0ShMt44.7160.0st1A Room5-A h204987480.1096.00x0ShMt31.0140.0st1 Room6 h5852540.0926.00x0ShMt32.2170.0st1A Room7 h173274320.0786.00x0ShMt25.2215.0st1B Room8 h2426103820.1086.00x0ShMt42.7130.0st1 Room8-A h2426103820.0966.00x0ShMt28.0165.0st1 Room8-B h2426103820.1076.00x0ShMt24.7150.0st1 Room8-C h2426103820.0796.00x0ShMt29.8205.0st1A Supply Trunk Detail Table TrunkHtgClgDesignVelocDiamH x WDuct NameType(cfm)(cfm)FR(fpm)(in)(in)MaterialTrunk st1Peak AVF7184690.07891512.00x0ShtMetl st1BPeak AVF74320.0789412.00x0ShtMetlst1A st1APeak AVF2891660.07836812.00x0ShtMetlst1 st2Peak AVF2571310.10732712.00x0ShtMetl st2APeak AVF109150.10713812.00x0ShtMetlst2 st2BPeak AVF4470.1075512.00x0ShtMetlst2A 2020-Oct-26 13:05:20 Right-Suite®Universal201919.0.13RSU20477 Page 1 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S Return Branch Detail Table GrilleHtgClgTELDesignVelocDiamH x WStud/JoistDuct NameSize (in)(cfm)(cfm)(ft)FR(fpm)(in)(in)Opening (in)MatlTrunk rb10x029520597.20.1794667.82-3.25x142-10x18SJSprt1 rb20x0199101113.50.1536316.93.25x1410x9SJSprt1 rb30x0280195224.20.0784449.02-3.25x142-10x18SJSprt1A rb40x0200990063403.25x1410x9SJSp Return Trunk Detail Table TrunkHtgClgDesignVelocDiamH x WDuct NameType(cfm)(cfm)FR(fpm)(in)(in)MaterialTrunk rt1APeak AVF2801950.0784449.02-3.25x14SdJstSprt1 rt1Peak AVF7755010.07863115.00x0ShtMetl 2020-Oct-26 13:05:20 Right-Suite®Universal201919.0.13RSU20477 Page 2 S:\\High Country\\Wrightsoft\\SF2B13 athens.rup Calc = MJ8 Front Door faces: S