HomeMy WebLinkAboutCONCRETE TEST 9 - 19-00727 - Spori Annex - Ceramic & Sculpture LabsProject Name:
Client:
Mix Number:
Project Number:
Ticket Number:
Load Amount:
Admixtures:
Tested By:
Date and Time:
Compressive Strength of Concrete Test Specimens
Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511)
Slump (Inches):
Entrained Air (%):
Concrete Temperature:
Ambient Temperature:
Test Results:Minimum:Maximum:
Cylinder #
Lab Test Data: (ASTM C39, C42, C617, and C1231)
Break Age
Cylinder
Diameter (in)
Area
(in² )
Break
Date
Maximum Load
(lbs)
Break
Type
Compressive
Strength (psi)Required 28 day
Strength (psi)
°F
°F
Reviewed By:
Supplier:
Test Location:
Unit Weight (PCF):Set # :
Cylinders Picked Up By: Date and Time:
Hi / Low Temperatures
Remarks:
28-day Average Strength
5,369 PSI
Spori Annex and Parking Lot
BYU - IDAHO
C401P546
20014A
64294
9 Yds
AE200, POLY 1025
N. Steiner
09/03/2020 10:00AM
6.5
4.6
72.1
68.7
8
4.5 7.5
300A
300E
300C
300B
300D
4
4
4
4
09/10/20
10/01/20
10/01/20
10/01/20
52,005
69,910
64,425
68,135
2 4,0004,137
5,561
5,125
5,420
Digitally signed by Jacob
Christensen
Date: 2020.10.01 10:08:55 -06'00'
12.57
Knife River
Directly in front of spori building front doors
7
28
28
28
H
12.57
12.57
12.57
cylinders are on concrete in light blue cooler
1 of 1
D. Aust 09/04/2020
5
5
2