HomeMy WebLinkAboutCONCRETE TEST 3 - 19-00727 - Spori Annex - Ceramic & Sculpture LabsProject Name:
Client:
Mix Number:
Project Number:
Ticket Number:
Load Amount:
Admixtures:
Tested By:
Date and Time:
Compressive Strength of Concrete Test Specimens
Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511)
Slump (Inches):
Entrained Air (%):
Concrete Temperature:
Ambient Temperature:
Test Results:Minimum:Maximum:
Cylinder #
Lab Test Data: (ASTM C39, C42, C617, and C1231)
Break Age
Cylinder
Diameter (in)
Area
(in² )
Break
Date
Maximum Load
(lbs)
Break
Type
Compressive
Strength (psi)Required 28 day
Strength (psi)
°F
°F
Reviewed By:
Supplier:
Test Location:
Unit Weight (PCF):Set # :
Cylinders Picked Up By: Date and Time:
Hi / Low Temperatures
Remarks:
28-day Average Strength
5,580 PSI
Spori Annex and Parking Lot
BYU - IDAHO
C401P546
20014A
2279623
10 Yards
AE200 POLY1025
L. Steiner
09/22/2020 9:00 AM
7.75
5
63.5
55.6
373A
373E
373C
373B
373D
4
4
4
4
09/29/20
10/20/20
10/20/20
10/20/20
56,410
69,275
70,730
70,435
2 4,0004,487
5,511
5,626
5,603
Digitally signed by Jacob
Christensen
Date: 2020.10.20 12:37:29 -06'00'
12.57
Knife River
Sidewalk on North West Corner of Parking Lot
7
28
28
28
H
12.57
12.57
12.57
Cooler is located just North of the curb on the North
side of the parking lot
1 of 1
J. Christensen Sep 23, 2020 8:00:00 AM
2
2
3