HomeMy WebLinkAboutBUILDING PERMIT REVIEWS - Andrews Place 29/26/2003 Dean Mortimer 7403 South lst East Idaho Falls, Idaho 83404 Dear Dean, cify 0 ev.11. a 0 l(.// STATE OF IDAHO www.ci.rexburg.id.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the plans for the Comfort Construction Apartments in the Andrews Addition #2 and have identified the following discrepancies, additions or questions: 1. Provide storm pond calculations. 2. Parking turnouts are required at the rear of the parking lots. 3. Identify trash facilities. 4. Provide accessible route to the public way as per the 2000 International Building Code (IBC) section 1104.3. 5. Dimensions are required from buildings to property lines. The building lines identified on the site plan must be that of the eaves. All setbacks are from the eaves. 6. The structural calculations are inconsistent with code requirements. The snow and wind loads of Idaho Falls were used instead of those for Rexburg. Rexburg's design wind speed is 90 mph and the snow load is 50 lb/sq. ft. at ground and 35 lb/sq. ft. on roof. Table 1609.6.2.1 (1) was used for wind analysis. This table is for wind exposure B. Exposure C should be used instead of B as there are no buildings to the West of the project to block the wind. The seismic calculations were figured using 'zone 3" which is a classification from the Uniform Building Code. Seismic calculations must be calculated using IBC procedure. 7. Please identify the exact locations of the HTT16 or PHD2 hold GOVVW. Sheet A03 identifies them with an "A" symbol at specific locations on the floor plan but contradicts these locations in the note below by calling them out at ends of the shear panels. Are there to be 2 hold downs per "A" symbol? 8. Cn the last page of the structural calculations document, the 4'' nail 11 VI1V spacing for the shear panels has been changed to 3". Please make the change to the building plans. Also, it is a common practice for the framing contractor to use staples instead of nails. Please have the engineering firm list a spacing for staples that is equivalent to the nail spacing. 9. Please provide truss details as soon as you can get them from the supplier, but before framing inspection. 10. Please identify special thickened washers for the anchor bolts as per the IBC. 11. Change building design to accommodate the exterior stairway open side requirement as per IBC section 1005.3.6.2. 12. The stair details on page A04 identify an 11" tread or run. The notes entitled "Stair System" identify a 10" tread. Please change this note to read 11 ". 13. All units on the lower level must be constructed as "Type B" units as per the IBC and ICC/ANSI Al 17.1. Identify as such. Please identify grab bar backing, accessible thresholds and all other accessible features. 14. Please identify smoke detectors as per the IBC and 2A-1 OBC fire extinguishers in each apartment unit. 15. Identify that bedroom windows must meet egress as per IBC. 16. Please identify firewall construction, including draftstops if used. Unit separation must be maintained from foundation to roof sheathing. Please provide details. 17. Please identify fire separation at the floors between units. Engineered joists have their own requirements for fire protection and are not listed in the IBC. Please provide this information on the plans. 18. Sinks and other plumbing elements are shown against unit fire separation walls. Show details that identify how the membrane is to be breached. Make sure that the plumbing contractor is aware that if they try to utilize one stack in the party wall and run plastic pipe from the wall to two units, special design is necessary. Using fire collars at the penetrations is one option, but the best option is to keep individual stacks in the plumbing wall of each unit and not in the party wall. 19. Provide energy calculations as per the 2000 International Energy Conservation Code (IECC). 20. I have attached a copy of the Fire Department review to the back of this document. Please resolve any issues identified by them. Please provide me with 2 new copies of any corrected plans. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen. Building Official C.C. John Millar Chris Huskinson P.O. Box 280 cify ��� 11��1%°�% 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 STATE OF IDAHO Fax (208) 359-3022 e-mail rexburg@srv.net REXB UR G -MADISON COUNTY EMERGENCY SERVICES 26 NORTH CENTER STREET REXB URG, IDAHO 83440 208359-3010 208-359-3006 FAX 2000 International Fire Code Plan Date: 7-15-02 Plan Review Review Date: 9-26-03 Building Name: ANDREWS ADDITION, DIVISION 2 Building Address: PORTER ROAD AND EVERETT PLACE Stories: 2 Type of Construction: V -B Occupancy Classification: R-2 Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 3300 SQUARE FEET (EACH BUILDING) I . Required F ire Flow (Appendix B): i, 750 GPi�v TWO HOURS Comments: FIRE FLOW MAY BE REDUCED IF STRUCTURES HAVE AN APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEM INSTALLED. 2. Water Supply (Section 508, Appendix C) Required: YES Fie -'Hydrant Location: OKAY Fire Hydrant Flows: UNKNOWN Fire Flow Test Location: NIA Fire Flow Supplied By: N/A Other Approved Water Source: NONE Water Supply Acceptable: YES, WITH ENGINEER'S CALCULATIONS OF AVAILABLE WATER FLOW PRIOR TO CONSTRUCTION Fire Hydrant Location Acceptable: YES Water Supply Comments: SEE ABOVE 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: OK Length: OH Surface: OK Complete Road Acceptable: YES Comments: NONE 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRION. TO CONSTRUCTION AND MIADE OPERATIONAL., A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: NOT SHOWN Type provided acceptable: NOT SHOWN f'On ni nty: PROV Dr MY—'7ii7-"jM n-1" 2A'OBC EYTy"—T--SC'AER iii EACA TvTIV" NEAR THE KITCHEN AREA IN AN UNOBSTRUCTED AND ACCESSIBLE LOCATION. 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: Sprinkler system monitoring (Section 907) required: NO Comments: NONE 7. Standpipes (Section 905) required: NO Type required: Comments: S. Ventilating hood and duct fire extinguisher system (Section 609) required: NO Type being provided: Automatic fuel shut-off required: Portable fire extinguisher shown: Comments: 9. Fire alarm systems (Section 907) required: YES Type of system required: Manual: Automatic: X Both: Type of system being provided: Manual: Automatic: Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO, PROVIDE SMOKE DETECTORS IN EACH SLEEPING ROOM AND IN THE CORRIDORS LEADING TO SLEEPING ROOMS. 10. Other corrections that are required by special occupancy or conditions: Pluir ani "iubtuitted + �^��' �Tn DT'i I--ri t"Y A DnlrV T,M,rc ar L. accepbQ.Vle: 11 V, 1�.1JL 1.11` 1 111)V V L` 11 IT -Lo Plans checked by: CHRIS HUSKINSON Date: 9-26-03 Please fiurnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X