Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION - 08-00140 & 08-00141 - Henry's Fork Plaza - Lot 25
wtrighisaftm Load Short Form Entire House Rocky Mountain Contractors Project M*- For: Lot 25, Henry's Fork Plaza, Suite #1 Rexburg, Id Job: Date: March 2008 By: G M Robertson Henry's Fork Plaza -Lot #25 Design Inf•. Htg Clg Infiltration Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 62 -31 HEATING EQUIPMENT Make Lennox Trade Air -Ease, American Aire, Armstrong Air Model 38HW** *** Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE Area 38000 Btuh 30000 Btuh 41 OF 800 cfm 0.030 cfm/Btuh 0.60 in H2O COOLING EQUIPMENT Make Lennox Trade Elite 11 Cond HS29-012-4P* Coil C33-30*-(F)+LB-85663L Area Efficiency 11.3 SEER Htg AVF Sensible cooling 9170 Btuh Latent cooling 3930 Btuh Total cooling 13100 Btuh Actual air flow 800 cfm Air flow factor 0.069 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 1.00 64 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) M Bath 120 0 0 0 0 Suite #1 1112 24801 11044 742 767 Room1 64 1946 475 58 33 Entire House 1296 26748 11520 800 800 Other equip loads 1456 268 Equip. @ 0.94 RSM 11081 Latent cooling 0 TnTAI C 419na Monne 4en0e nnn nnn Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrig htsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:38:13 �� C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 1.rrp Calc = MJ8 Orientation Page 1 wrightsoft- Building Analysis the r1shtcitu a Entire House Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #1 Rexburg, Id Job: Date: March 2008 By: G M Robertson Heating Component Desiq-n Conditions Walls 5.2 Location: Idaho Falls, ID, US Glazing Indoor: Indoor temperature (°F) Heating 70 Cooling 75 Elevation: 4741 ft Latitude: 44°N 1303 4.6 Design TD (ON 76 14 Outdoor: Heating Cooling Relative humidity (%) Moisture difference (gr/Ib) 50 61.5 50 -31.5 Dry bulb (°F) -6 89 Infiltration: 5826 20.7 Pi In Daily range (°F) - Wet bulb (°F) - 34 ( H) 60 Method Construction quality Simplified Average 0 0.0 Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft2 Btuh % of load Walls 5.2 3313 11.7 Glazing 35.7 4501 16.0 Doors 26.6 1303 4.6 Ceilings 2.0 2561 9.1 Floors 2.9 3782 13.4 Infiltration 6.7 5462 19.4 Ducts 5826 20.7 Pi In 268 2.3 Humidification 0 0.0 Ventilation 1456 5.2 Adjustments 0 Total 28204 1 100.0 Cooiin Component Btuh/ft2 Btuh % of load Walls 0.6 410 3.5 Glazing 32.6 4113 34.9 Doors 6.5 317 2.7 Ceilings 1.1 1415 12.0 Floors 0.5 697 5.9 Infiltration 0.6 514 4.4 Ducts 4053 34.4 Ventilation 268 2.3 Internal gains 0 0.0 Blower 0 0.0 Adjustments 0 Total 11788 100.0 Overall U -value = 0.064 Btuh/ft2-°F Data entries checked. , vvr10 htS.C> t Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:38:13 A--Ck C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 1.rrp Calc = MJ8 Orientation Page 1 wrightsoft- Component Constructions Job: The right Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors * s o For: Lot 25, Henry's Fork Plaza, Suite #1 Rexburg, Id Location: Idaho Falls, ID, US 0.470 Indoor: Heating Cooling Elevation: 4741 ft 1430 Indoor temperature (°F) 70 75 Latitude: 44°N 1286 Design TD (°F) Relative humidity (%) 76 50 14 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: 0.350 0.0 Daily range (°F) - 34 ( H) Method Simplified w 28 Wet bulb (°F) - Wind speed (mph) 15.0 60 7.5 Construction quality Average 6.47 181 all 49 Fireplaces 0 26.6 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain Walls 1.98 ft= Btuh/ft? °F ft� °F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh 12E-Osw: Wood stud frame, siding or stucco, no board insulation, n 294 0.068 19.0 5.17 1519 0.64 188 R-19 cavity insulation a 195 0.068 19.0 5.17 1008 0.64 125 w 152 0.068 19.0 5.17 786 0.64 97 all 641 0.068 19.0 5.17 3313 0.64 410 Partitions (none) Windows 4A1-2ov: Operable, vinyl frame, low -e glass, a=0.20 surface 2, 2 pane Doors 11 NO: Metal door, polystyrene core, no storm Ceilings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation Floors 19A-19cvtp: Tile floor over vented enclosed crawl, No wall insul R-19 blanket n 90 0.470 0.0 35.7 3215 15.9 1430 w 36 0.470 0.0 35.7 1286 52.4 1888 all 126 0.470 0.0 35.7 4501 26.3 3317 e 21 0.350 0.0 26.6 559 6.47 136 w 28 0.350 0.0 26.6 745 6.47 181 all 49 0.350 0.0 26.6 1303 6.47 317 1296 0.026 38.0 1.98 2561 1.09 1415 1296 0.049 19.0 2.92 3782 0.54 697 ,�. wrjg htsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:38:13 ,CCK C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 1.rrp Calc = MJ8 Orientation Page 1 wrightsoft- Project Summary Job: fQfight dmk" Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #1 Rexburg, Id Notes: Weather: Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TD 76 OF Heating Summary H Structure 20921 Btuh Ducts 5826 Btuh Central vent (21 cfm) 1456 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 28204 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Idaho Falls, ID, US Simplified Average 0 He tin r11296 Co 1296 OF 99 10368 10368 0.45 0.23 78 40 Heating Equipment Summary Make Lennox Trade Air -Ease, American Aire, Armstrong Air Model 38HW**-*** Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 38000 Btuh 30000 Btuh 41 °F 800 cfm 0.030 cfm/Btuh 0.60 in H2O Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range Reative humidity H Btuh Moisture difference 50 -31 % gr/Ib Sensible Cooling Equipment Load Sizing Structure 7467 Btuh Ducts 4053 Btuh Central vent (21 cfm) 268 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 11081 Btuh Latent Cooling Equipment Load Sizing Structure -715 Btuh Ducts -94 Btuh Central vent (21 cfm) -373 Btuh Equipment latent load 0 Btuh Equipment total load 11081 Btuh Req. total capacity at 0.70 SHR 1.3 ton Cooling Equipment Summary Make Lennox Trade Elite 11 Cond HS29-012-4P* Coil C33-30*-(F)+LB-85663L Efficiency Sensible cooling 11.3 SEER 9170 Btuh Latent cooling 3930 Btuh Total cooling 13100 Btuh Actual air flow 800 cfm Air flow factor 0.069 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. tn✓r�gl >ttsC>ft Right -Suite Residential 6.0.107 RSR41031 ,4CCK C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 1.rrp Calc = MJ8 Orientation 2008 -Mar -18 08:38:13 Page 1 wrightsoftm AED Assessment Job: the'9kch Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Location: Idaho Falls, ID, US Elevation: 4741 ft Latitude: 44°N Outdoor: Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) Lot 25, Henry's Fork Plaza, Suite #1 Rexburg, Id Heating Cooling -6 89 - 34 ( H - 60 15.0 7.5 Indoor: Heating Indoor temperature (°F) 70 Design TD (°F) 76 Relative humidity (%) 50 Moisture difference (gr/Ib) 61.5 Infiltration: Test for Adequate Exposure Diversity Hourly Glazing Load Hoary Hour of Day A—Qrz .' AEDIirtil Maximum hourly glazing load exceeds average by 55.9%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 796 Btuh (PFG - 1.3*AFG) Cooling 75 14 50 -31.5 ,� wrrg rjtsoft Right -Suite Residential 6.0.107 RBR41031 2008 -Mar -18 08:38:13 ACC:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 1.rrp Calc = MJ8 Orientation Page 1 +wrightsofta Right -J Worksheet Job: Entire House Date: March 2008 Rocky Mountain Contractors By: G M Robertson 1 2 3 4 Room name Exposed wall Ceiling height Room dimensions Entire House 102.0 ft 8.0 ft M Bath 23.0 ft 8.0 ft heat/cool 5 Room area 1296.0 ft2120.0 215.0 x 8.0 ft ft2 15.0 Ty Construction number U -value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IW L -G W r 11 W C F 12E-Osw 4A1-2.,, 12E-Osw 11 NO 12E-Osw 4A1-2ov 11 NO 16B-38ad 19A-19cvtp 0.068 0.470 0.068 0.350 0.068 0.470 0.350 0.026 0.049 n n e e w w w 5.17 35.72 5.17 26.60 5.17 35.72 26.60 1.98 2.92 0.64 384 294 1519 188 15.88 90 0 3215 1430 0.64 216 195 1008 125 6.47 21 21 559 136 0.64 216 152 786 97 52.43 36 0 1286 1888 6.47 28 28 745 181 1.09 1296 1296 2561 1415 0.54 1296 102 3782 697 64 64 331 41 0 0 0 120 120 620 77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 120 237 131 120 23 350 65 6 c) AED excursion 0 796 Envelope loss/gain 15460 6952 1538 313 12 a) Infiltration b) Room ventilation 54620 5140 12359%0 13 Internal gains: Occupants @ 230 Appliances @ 1200 0 O 0 0 0 0 Subtotal (lines 6 to 13) 20921 7467 Less external load 14 15 Less transfer Redistribution Subtotal Duct loads 28% 54% 0 0 0 20921 5826 0 0 0 7467 4053 28%Total room loadAir required (cfm) 26748 11520 Printout certified bV ACCA to meet all requirements of Manual J 8th Ed "` wrrc� htsol t Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:38:13 ACCP, C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 1.rrp Calc = MJ8 Orientation Pagel wrightsoftmRight-J Worksheet Job: 1h.0efickc Entire House Date: March 2008 Rocky Mountain Contractors By: G M Robertson 1 Room name 2 Exposed wall Suite #1 Room1 3 Ceiling height 71.0 ft 8.o ft ft heat/cool 4 Room dimensions 8.0 ft heat cool :64.0 5 Room area 1.0 x 1112.0 ft 8.0 x 8.0 ft 1112.0 ft2 ft� Ty Construction U -value inHTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-°F)(Btuh/ftz or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W L—G 12E-Osw 4A1-2ov 0.0685.17 0.64 320 230 1189 147 0 0 0 W 12E-Osw 0.47035.72 0.068 e 5.17 15.88 0.64 90 0 3215 1430 32 0 0 0 0 0 L -D 11NO 0.350 e 26.60 6.47 32 165 20 64 0 0 0 43 222 27 11 W 12E-Osw 0.068 w 5.17 0.64 0 21 216 152 786 97 21 559 0 136 EG D 4A1-2ov 11NO 0.470 w 35.72 52.43 36 0 1286 1888 0 0 0 0 0 C 1613-38ad 0.350 0.026 w 26.60 1.98 6.47 1.09 28 28 745 181 1112 1112 2197 0 0 0 0 0 F 19A-19cvtp 0.049 2.92 0.54 1214 64 1112 71 3245 598 64 64 126 70 8 187 34 6 c) AED excursion 0 796 Envelope loss/gain 1094 268 12828 6371 12 a) Infiltration 428 400 b) Room ventilation 38020 358 0 0 13 Internal gains: Occupants @ 230 0 Appliances @ 1200 00 0 0 0 p 0 Subtotal (lines 6 to 13) 16629 6729 1522 308 Less external load 0 0 Less transfer O o Redistribution 00 9 0 01 14 Subtotal 277 42 15 Duct loads 28% 54% 19399 5402 7159 3886 28% 54% 522 1424 308 167 Total room load 1946 475 Air required (cfm) 24801 801 11044 767 58 33 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. , Right -Suite Residential 6.0.107 RSR41031 SCP. C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 1.rrp Calc = MJ8 Orientation 2008 -Mar -18 08:38:13 Page ag2 2 - ' wrightsoft. Duct System Summary Job: therdgkx dinkeEntire e HOUSe Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #1 Rexburg, Id External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.60 in H2O 0.00 in H2O 0.60 in H2O 0.44/0.16 in H2O 0.189 in/100ft 800 cfm 317 ft Cooling 0.60 in H2O 0.00 in H2O 0.60 in H2O 0.44/0.16 in H2O 0.189 in/100ft 800 cfm Name Design Htg Clg Design Diam H X W Duct Actual Ftg.Egv Name Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Suite #1-A C 2761 185 192 0.189 7.0 Ox 0 ShMt 60.0 170.0 st1A Suite #1 c 2761 185 192 0.209 7.0 OX 0 ShMt 48.0 160.0 st1 Suite #1-B C 2761 185 192 0.218 7.0 0x0 ShMt 30.0 170.0 st1 Suite #1-C c 2761 185 192 0.407 7.0 0x0 ShMt 12.0 95.0 Room1 h 1946 58 33 0.292 6.0 Ox 0 ShMt 24.0 125.0 st1 B Name Trunk Htg Clg Design Veloc Diam H x W Duct Stud/Joist Opening (in) Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 B Peak AVF 58 33 0.292 262 3.8 8 x 4 ShtMetl st1A st1A Peak AVF 244 225 0.189 1096 7.1 8 x 4 ShtMetl st1 st1 Peak AVF 615 1 608 1 0.189 782 12.0 0 x 0 RndFbg Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 0x0 800 800 87.0 0.189 573 16.0 Ox 0 ShMt rt1 , wrig htsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:38:14 ACCK C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 1.rrp Calc = MJ8 Orientation Page 1 Z abed uol;e;u9u0 8fW = oleo dirt a;mS SZ 10-1 W=1 s,,Gua 17 8E 80 81-Ie W-800Z H\s;oafoJd\oV/�H Sos;y6uMls;uawn0ot] AW\:O O! L£01421Sa L01'0'91e1;uaplsaa a}mg-;y61a �-OS�.I.,'�L./M z I19INNS ZZ X 8 � unal leiaa;eW (ui) (ui) }0na M X H we!(] (wd}) W 1 (WJO) (WIO) 0019A u6lsaa 610 61H JAd �ead 6� edA_L GweN � unal -- wrightsoft. Load Short Form Job: thR``° Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #2 Rexburg, Id Htg clg Infiltration Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 62 -31 HEATING EQUIPMENT Make Lennox Trade Air -Ease, American Aire, Armstrong Air Model 38HW**-*** Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE Area (ft2) 38000 Btuh 30000 Btuh 41 OF 800 cfm 0.034 cfm/Btuh 0.60 in H2O COOLING EQUIPMENT Make Lennox Trade Elite 11 Cond HS29-012-4P* Coil C33-30*-(F)+LB-85663L Area (ft2) Efficiency 11.3 SEER Htg AVF (cfm) Sensible cooling 9170 Btuh Latent cooling 3930 Btuh Total cooling 13100 Btuh Actual air flow 800 cfm Air flow factor 0.076 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 1.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Stor Suite #2 Lav 126 1180 72 0 20558 2720 0 9863 608 0 707 93 0 754 46 Entire House Other equip loads Equip. @ 0.94 RSM Latent cooling 1378 23278 1549 10471 285 10111 0 800 800 TOTALS 1378 7dR7R 101 11 800 800 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ,c-- wri0htsC3ft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:37:13 CK C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 2.rrp Calc = MJ8 Orientation Page 1 wrightscllft- Building Analysis Job: tire right dwke Entire House Date: March 2008 Rocky Mountain Contractors By: G M Robertson For: Lot 25, Henry's Fork Plaza, Suite #2 Rexburg, Id Location: Idaho Falls, ID, US Elevation: 4741 ft Btuh/ftZ Indoor: Indoor temperature (°F) Latitude: 44°N Walls Glazing Desiggn TD (°F) Relafive humidity Outdoor: Heating Cooling (%) Moisture difference (gr/Ib) Dabulb F lly range ( 6 °F) Infiltration: 34 (H) 5.3 Wet bulb (°F) - Wind speed (mph) 15.0 60 7.5 Method Construction quality 11.0 Floors Fireplaces Component Btuh/ftZ Btuh % of load Walls Glazing 5.2 35.7 2124 1286 8.6 5.2 Doors 26.6 1303 5.3 Ceilings 2.0 2723 11.0 Floors 2.9 4022 16.2 Infiltration 11.7 5807 23.4 Ducts 6013 24.2 Piping 10756 100.0 0 0.0 Humidification 0 0.0 Ventilation 1549 6.2 Adjustments 0 Total 24826 100.0 Component-7/6Btuh/f? Cooling Btuh of load Walls 0.6 263 2.4 Glazing 81.1 2919 27.1 Doors Ceilings 6.5 1.1 317 2.9 1505 14.0 Floors Infiltration 0.5 1.1 741 6.9 547 5.1 Ducts Ventilation 4180 38.9 Internal gains 285 2.7 0 0.0 Blower 0 0.0 Adjustments 0 Total 10756 100.0 Overall U -value = 0.051 Btuh/ftz-°F WARNING: window to floor area ratio = 2.6% - less than 5%. Heating Cooling 70 75 76 14 50 50 61.5 -31.5 Simplified Average 0 wrlg htsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:37:13 ACCA C:1My Documents\Wrightsoft HVACTrojects\Henry's Fork Lot 25 Suite 2.rrp Calc = MJ8 Orientation Page 1 wrightsoft- Component Constructions Job: thertgke Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #2 Rexburg, Id Location: 0.470 0.0 35.7 Idaho Falls, ID, 52.4 Indoor: Heating Cooling Elevation: 47411 ft 0.0 Indoor temperature (°F) 70 75 Latitude: 44°N 136 Design TD (°F) 76 14 Outdoor: Heating Cooling Relative humidity (%) 50 Moisture difference (gr/Ib) 61.5 50 Dry bulb (°F) -6 Daily range (°F) 89 Infiltration: -31.5 - Wet bulb (°F) 34 ( H) 60 Method Simplified 317 Wind speed (mph) 15.0 7 5 Construction quality Average Fireplaces 1.98 2723 1.09 0 1378 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain Walls 741 ft' Btuh/W °F ft' °F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh 12E-Osw: Wood stud frame, siding or stucco, no board R-19 cavity insulation insulation, n 40 0.068 19.0 5.17 207 e 187 0.068 19.0 5.17 966 0.64 26 0.64 120 s 40 0.068 19.0 5.17 207 0.64 26 w 144 0.068 19.0 5.17 744 0.64 92 all 411 0.068 19.0 5.17 2124 0.64 263 Partitions (none) Windows 4A1-2ov: Operable, vinyl frame, low -e glass, a=0.20 surface 2, 2 pane Doors 11 NO: Metal door, polystyrene core, no storm Ceilings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation Floors 19A-19cvtp: Tile floor over vented enclosed crawl, No wall insul, R-19 blanket w 36 0.470 0.0 35.7 1286 52.4 1888 e 21 0.350 0.0 26.6 559 6.47 136 w 28 0.350 0.0 26.6 745 6.47 181 all 49 0.350 0.0 26.6 1303 6.47 317 1378 0.026 38.0 1.98 2723 1.09 1505 1378 0.049 19.0 2.92 4022 0.54 741 wrjghtSC:>ft Right -Suite Residential 6.0.107 RSR41031 C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 2.rrp Calc = MA Orientation 2008 -Mar -18 08:37:14 Page 1 + wrightsoft- Project Summary Job: *0ftk`hQk* Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #2 Rexburg, Id Notes: Weather: Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TD 76 OF Heating Summary H Structure 17265 Btuh Ducts 6013 Btuh Central vent (22 cfm) 1549 Btuh Humidification 0 Btuh Piping p g 0 Btuh Equipment load 24826 Btuh Infiltration Idaho Falls, ID, US Method Simplified Construction quality Average Fireplaces 0 Area (ft2) Heatinglin 1378 Co 1378 Volume (fF) 11024 11024 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 83 42 Heating Equipment Summary Make Lennox Trade Air -Ease, American Aire, Armstrong Air Model 38HW**-*** Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 38000 Btuh 30000 Btuh 41 OF 800 cfm 0.034 cfm/Btuh 0.60 in H2O Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range Relative humidity H Btuh Moisture difference 50 -31 % gr/Ib Sensible Cooling Equipment Load Sizing Structure 6292 Btuh Ducts 4180 Btuh Central vent (22 cfm) 285 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 10111 Btuh Latent Cooling Equipment Load Sizing Structure -760 Btuh Ducts -96 Btuh Central vent (22 cfm) -397 Btuh Equipment latent load 0 Btuh Equipment total load 10111 Btuh Req. total capacity at 0.70 SHR 1.2 ton Cooling Equipment Summary Make Lennox Trade Elite 11 Cond HS29-012-4P* Coil C33-30*-(F)+LB-85663L Efficiency 11.3 SEER Sensible cooling 9170 Btuh Latent cooling 3930 Btuh Total cooling Actual air flow 13100 800 Btuh cfm Air flow factor 0.076 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrlightsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:37:14 ACrA C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 2.rrp Calc = MJ8 Orientation Page 1 wrightsoft- AED Assessment Job: twe'djIMAaw Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #2 Rexburg, Id Location: Idaho Falls, ID, US Indoor: Indoor temperature (°F) Heating 70 Cooling 75 Elevation: 4741 ft Latitude: 44°N Design TD (°F) 76 14 Heating Outdobulb Coo89 g Relative humidity (%) Moisture difference (gr/Ib) 50 61.5 50 -31.5 (F) DryDaily range (°F) - 34 H ( ) Infiltration: Wet bulb (°F) - 60 Wind speed (mph) 15.0 7.5 Hourly Glazing Load Hour of Da ; Homy Y Avenge / AEDlirtvt Maximum hourly glazing load exceeds average by 98.7%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 1032 Btuh (PFG - 1.3*AFG) wrig htsaft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:37:14 to C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 2.rrp Calc = MJ8 Orientation Page 1 �` wrightsoft" Right -J Worksheet Job: Entire House Date: March 2008 Rocky Mountain Contractors By: G M Robertson 1 2 3 4 Room name Exposed wall Ceiling height Room dimensions Entire House 62.0 ft 8.0 ft Stor 15.0 ft 8.0 ft heat/cool 5 Room area 1378.0 ft2126.0 ft 214.0 x 9.0 ft Ty Construction number U -value (Btuh/ft2-°F) Or HTM (Btuh Area (ft2) or perimeter (ft) Load (Btuh) Area(T) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W W �—D W 11 W L—G.64 D C F 12E-Osw 12E-Osw 11 NO 12E-Osw 12E-Osw 4A1-2ov 11 NO 16B-38ad 19A-19cvtp 0.068 0.068 0.350 0.068 0.068 0.470 0.350 0.026 0.049 n e e s w w w 5.17 5.17 26.60 5.17 5.17 35.72 26.60 1.98 2.92 0.64 40 40 0.64 208 187 6.47 21 21 0.64 40 40 0208 144 52.43 36 0 6.47 28 28 1.09 1378 1378 0.54 1378 62 207 26 8 g 41 5 966 120 112 112 579 72 559 136 0 0 207 26 O O 0 0 744 92 0 0 0 0 1286 1888 0 0 0 0 745 181 0 0 O 0 2723 1505 126 126 249 138 4022 741 126 15 368 68 6 c) AED excursion 1032 Envelope loss/gain 11458 5745 0 1237 12 a) Infiltration 282 14050 1320 b) Room ventilation 58007 5470 13 Internal gains: Occupants @ 230 Appliances @ 1200 0 0 0 0 0 0 0 0 l (lines 6 to 13) 17265 6292 2642 414 ternal load ansfer ibution l ads r 35% 66% 0 0 0 17265 6013 0 0 0 6292 4180 35% 66% 0 0 -2642 0 0 0 0 -414 0 0 om load ired (cfm) 23278 800 10471 800 0 01 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. A& wnis-11cJ htsofi't Right -Suite Residential 6.0.107 RSR41031 C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 2.rrp Calc = MJ8 Orientation 2008 -Mar -18 08:37:14 Pagel 1 1 1 1 rihts ft- 'k Ylghta4t Right -J Worksheet Entire House Rocky Mountain Contractors Job: Date: March 2008 By: G M Robertson Printout certified by ACCA to meet all requirements of Manual J 8th Ed. NA i itscrtFt Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:37:14 SCP C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 2.rrp Calc = MJ8 Orientation Page 2 wryg htsoft- Duct System Summary Jab: tke tight choke Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #2 Rexburg, Id External static pressure Heating 0.60 in H2O j, NII Cooling Pressure losses 0.00 in H2O 0.60 0.00 in H2O in H2O Available static pressure Supply / return available pressure 0.60 in H2O 0.60 in H2O Lowest friction rate 0.43/0.17 in H2O 0.43/0.17 in H2O Actual air flow 0.192 in/100ft 0.192 in/100ft Total effective length (TEL) 800 cfm 800 cfm c 2466 177 188 313 ft 7.0 Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Suite #2-A c 2466 177 188 0.192 7.0 Ox 0 ShMt 66.0 Suite #2 c 2466 177 188 0.195 7.0 Oxo ShMt 52.0 Suite #2-B c 2466 177 188 0.263 7.0 0x0 ShMt 50.0 Suite #2-C c 2466 177 188 0.358 7.0 Ox 0 ShMt 26.0 Lav h 2720 93 46 0.212 6.0 OX 0 ShMt 24.0 HxW (in) 8 x 6 0 x 0 Ftg. Eqv Trunk Htg Clg Design Veloc Diam Name Type (cfm) (cfm) FR (fpm) (in) st1A Peak AVF 270 235 0.212 810 7.3 st1 Peak AVF 623 612 0.192 794 12.0 HxW (in) 8 x 6 0 x 0 Ftg. Eqv Grill Size (in) Ln (ft) Trunk 160.0 st1 170.0 st1 115.0 st1A 95.0 Duct Matl 180.0 st1A Name Grill Size (in) Duct Clg (cfm) Material Trunk ShtMetl st1 RndFbg Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 0x0 800 800 87.0 0.192 573 16.0 Ox 0 ShMt rt1 WI'IghtSOft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:37:15 CK CAMy Documents\Wrightsoft HVACTrojects\Henry's Fork Lot 25 Suite 2.rrp Calc = MA Orientation Page 1 Z abed uoi;e;uau0 SfW =ole dna a SL:LB 80 86-JeW-800Z Z p in S SZ;ol �aod s,AjugRs;oafoad\OVAH gos;y6uM\s;u9wnooa (W`:p NOOV lEOlbbSb LOl'0'9 lei;uapisaa aunS-i46ia �-OS�.L.�61_IM ^'';'r I19INNS ZZ x 8 � unjl leua}eIN (ui) (ui) lona M x H wela 999 1 Z66'0 1 008 1 008 (Wd})I (W10) I (wid0) 0018n ubisa4 610 61H dnd plead 6 adAi GweN �unal wrightsoft- Load Short Form Job: the Aght Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #3 Rexburg, Id Htg Clg Infiltration Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 62 -31 HEATING EQUIPMENT Make Lennox Trade Air -Ease, American Aire, Armstrong Air Model 38HW**-*** Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE Area 38000 Btuh 30000 Btuh 41 OF 800 cfm 0.030 cfm/Btuh 0.60 in H2O COOLING EQUIPMENT Make Lennox Trade Elite 11 Cond HS29-012-4P* Coil C33-30*-(F)+LB-85663L Area Efficiency 11.3 SEER Htg AVF Sensible cooling 9170 Btuh Latent cooling 3930 Btuh Total cooling 13100 Btuh Actual air flow 800 cfm Air flow factor 0.064 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 1.00 64 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Storage 112 0 0 0 0 Suite #3 Lav 1120 25377 12189 759 782 64 1371 275 41 18 Entire House Other equip loads 1296 26748 12464 800 800 Equip. @ 0.94 RSM 1456 268 11969 Latent cooling 0 TOTALS 1 A7nn 4 -1ncr, -- uw ovu Printout certified by ACCA to meet all requirements of Manual J 8th Ed wrightsc)ft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:41:16 (`,K CAMy Documents\Wrightsoft HVAMProjects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation Page 1 wrightso . Building Analysis Job: the fight choke Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #3 Rexburg, Id Heating Component Btuh/ft2 Btuh % of load Walls 5.2 3313 Location: Idaho Falls, ID, US Glazing Indoor: Indoor temperature (°F) Heating 70 Cooling 75 Elevation: 4741 ft Latitude: 440N 4.6 Design TD (°F 76 14 Outdoor:bulb (F) Heating DryDaily Cooling Relative humidity (%) Moisture difference (gr/Ib) 50 61.5 50 -31.5 range (°F) - Wet bulb (°F) 34 ( H Infiltration: ) Method Simplified Piping _ Wind speed (mph) 15.0 60 7.5 Construction quality Fireplaces Average 0 0.0 Heating Component Btuh/ft2 Btuh % of load Walls 5.2 3313 11.7 Glazing 35.7 4501 16.0 Doors 26.6 1303 4.6 Ceilings 2.0 2561 9.1 Floors 2.9 3782 13.4 Infiltration 6.7 5462 19.4 Ducts 5826 20.7 Piping 268 2.1 Humidification 0 0.0 Ventilation 1456 5.2 Adjustments 0 Total 28204 1 100.0 Coaling Component Btuh/ft2 Btuh % of load Walls 0.6 410 3.2 Glazing 40.1 5058 39.7 Doors 6.5 317 2.5 Ceilings 1.1 1415 11.1 Floors 0.5 697 5.5 Infiltration 0.6 514 4.0 Ducts 4053 31.8 Ventilation 268 2.1 Internal gains 0 0.0 Blower 0 0.0 Adjustments 0 Total 12732 100.0 Overall U -value = 0.064 Btuh/ft2-°F Data entries checked. ,� wr1g htsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:41:16 ACACk C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation Page 1 wrightsoft- Component Constructions Job: 49kt = Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #3 Rexburg, Id Location: Idaho Falls, ID, US Or Indoor: Indoor temperature (°F) Heating 70 Cooling 75 Elevation: 4741 ft Latitude: 440N Loss Design TD (°F) 76 14 Outdoor: Heating Cooling Relative humidity (%) Moisture difference (gr/lb) 50 61.5 50 -31.5 Dry bulb (°F) -6 Daily range (°F) - 89 34 H ( ) Infiltration: 12E-Osw: Wood stud frame, siding or stucco, no board insulation, a Wet bulb (°F) - Wind speed (mph) 15.0 60 7.5 Method Construction quality Fireplaces Simplified p d Average 0 e Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain Walls 0.470 ft' Btuh/fF °F ft--°F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh 12E-Osw: Wood stud frame, siding or stucco, no board insulation, a 195 4501 35.4 4464 e 21 0.350 R-19 cavity insulation 26.6 559 0.068 19.0 5.17 1008 0.64 125 26.6 s 294 0.068 19.0 5.17 1519 0.64 188 1303 w 152 0.068 19.0 5.17 786 0.64 97 1.09 all 641 0.068 19.0 5.17 3313 0.64 410 Partitions (none) Windows 4A1-2ov: Operable, vinyl frame, low -e glass, a=0.20 surface 2, 2 pane Doors 11 NO: Metal door, polystyrene core, no storm Ceilings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation Floors 19A-19cvtp: Tile floor over vented enclosed crawl, No wall insul, R-19 blanket s 90 0.470 0.0 35.7 3215 28.6 2576 w 36 0.470 0.0 35.7 1286 52.4 1888 all 126 0.470 0.0 35.7 4501 35.4 4464 e 21 0.350 0.0 26.6 559 6.47 136 w 28 0.350 0.0 26.6 745 6.47 181 all 49 0.350 0.0 26.6 1303 6.47 317 1296 0.026 38.0 1.98 2561 1.09 1415 1296 0.049 19.0 2.92 3782 0.54 697 wrig htsc:),ft Right -Suite Residential 6.0.107 RSP41031 2008 -Mar -18 08:41:16 ,moi, K C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation Page 1 wrightsoft- Project Summary Job: the rNM Entire House Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #3 Rexburg, Id Notes: Design Information Weather: Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TD 76 OF Heating Summary H 50 Btuh Structure 20921 Btuh Ducts 5826 Btuh Central vent (21 cfm) 1456 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 28204 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft') Air changes/hour Equiv. AVF (cfm) Idaho Falls, ID, US Simplified Average 0 Heating1296 Co 1296 OF Inside db 10368 10368 0.45 0.23 78 40 Heating Equipment Summary Make Lennox Trade Air -Ease, American Aire, Armstrong Air Model 38HW**-*** Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 38000 Btuh 30000 Btuh 41 OF 800 cfm 0.030 cfm/Btuh 0.60 in H2O Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range Relative humidity H 50 Btuh Moisture difference -31 % gr/Ib Sensible Cooling Equipment Load Sizing Structure 8411 Btuh Ducts 4053 Btuh Central vent (21 cfm) 268 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 11969 Btuh Latent Cooling Equipment Load Sizing Structure Ducts Central vent (21 cfm) -715 -94 -373 Btuh Btuh Btuh Equipment latent load 0 Btuh Equipment total load Req, total capacity at 0.70 SHR 11969 1.4 Btuh ton Cooling Equipment Summary Make Lennox Trade Elite 11 Cond HS29-012-4P* Coil C33-30*-(F)+LB-85663L Efficiency 11.3 SEER Sensible cooling 9170 Btuh Latent cooling 3930 Btuh Total cooling 13100 Btuh Actual air flow 800 cfm Air flow factor 0.064 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. vri0htso-Ft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:41:16 ACCA C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation Page 1 wrightsoft- AED Assessment Job: the Tlyhfch EI1%/Pe HOuse Date: March 2008 By: G M Robertson Rocky Mountain Contractors For: Lot 25, Henry's Fork Plaza, Suite #3 Rexburg, Id Hourly Glazing Load of Day AEDlimt Maximum hourly glazing load exceeds average by 40.9%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 594 Btuh (PFG-1.3*AFG) ,.,:- wrIghtsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:41:16 C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation Page 1 Deskin s s s Location: Idaho Falls, ID, US Indoor: Indoor temperature (°F) Heating 70 Cooling 75 Elevation: 4741 ft Design TD (°F) 76 14 Latitude: 440N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 ulb Dry (�F) g Infiltration: Daily range (°F) - 34 ( H ) Wet bulb (°F) - 60 Wind speed (mph) 15.0 7.5 • s-• ss i Hourly Glazing Load of Day AEDlimt Maximum hourly glazing load exceeds average by 40.9%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 594 Btuh (PFG-1.3*AFG) ,.,:- wrIghtsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:41:16 C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation Page 1 ` wreghtsoft- Right -J Worksheet Entire House Rocky Mountain Contractors Job: Date: March 2008 By: G M Robertson 1 2 Room name Exposed wall Entire House Entire eft Storage 3 Ceiling height 22.0 ft 4 Room dimensions 8.0 ft 8.0 ft heat/cool 5 Room area 1296.0 ft 2 14.0 x 8.0 ft 112.0 ft� Ty Construction U -value Or HTM Area (ftz) Load Area (ftZ) Load number (Btuh/ftz-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-0sw 11 NO 0.068 e 5.17 0.64 216 195 1008 125 112 112 579 72 IW 12E-Osw 0.350 0.068 e s 26.60 5.17 6.47 0.64 21 384 21 294 559 1519 136 188 0 0 0 0 �—G 4A1-2.,, 0.470 s 35.72 28.62 90 0 3215 2576 64 0 64 0 331 0 41 0 11 IW 12E-Osw 0.068 w 5.17 0.64 216 152 786 97 0 0 0 –li �—D 4A1-2ov 0.470 w 35.72 52.43 36 0 1286 1888 0 0 0 0 0 C 11NO 0.350 w 26.60 6.47 28 28 745 181 0 0 0 0 F 166-38ad 19A-19cvtp 0.026 0.049 1.98 2,92 1.09 0.54 1296 1296 2561 1415 112 112 221 122 1296 102 3782 697 112 22 327 60 6 c) AED excursion 594 0 Envelope loss/gain 15460 7897 1458 295 12 a) Infiltration b) Room ventilation 5462 514 1176 111 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 Appliances @ 1200 0 O 0 0 0 Subtotal (lines 6 to 13) 20921 8411 2636 406 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 -2636 -406 15 Duct loads o 28% 0 48% 20921 5826 8411 4053 28% 48% 0 0 0 0 Total room load Air required (cfm) 26748 12464 O O 800 800 01 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed tsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:41:16 ACCK C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation Page 1 U= Right -J Worksheet Entire House Rocky Mountain Contractors Job: Date: March 2008 By: G M Robertson 1 Room name 2 Exposed wall Suite #3 Lav 3 4 Ceiling height Room dimensions 72 it ft 8.0 ft heat/cool 8.0 ft 8.0 ft heat/cool 5 Room area 1.0 x 1120.0 ft 8.0 x 8.0 ft 1120.0 ftz 64.0 ftz Ty Construction U -value Or HTM Area (ftz) Load Area (ft2) Load number (Btuh/ftz °F) (Btuh/ftz) or perimeter ft () (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W L—D 12E-Osw 11 NO 0.068 e 5.17 0.64 40 19 98 12 64 64 331 41 IW _ 12E-Osw 0.350 0.068 e s 26.60 5.17 6.47 0.64 21 320 21 230 559 1189 136 147 0 0 0 0 0 11 L --G W 4A1-2ov 12E-Osw 0.470 0.068 s w 35.72 5.17 28.62 0.64 90 0 3215 2576 0 0 0 0 0 0 0 216 152 786 97 0 0 0 0 G4A1-2ov 0.470 w 35.72 52.43 36 0 1286 1888 0 0 0 0 D 11NO 0.350 w 26.60 6.47 28 28 745 181 0 0 0 0 C F 16B-38ad 19A-19cvtp 0.026 0.049 1.98 2.92 1.09 1120 1120 2213 1223 64 64 126 70 0.54 1120 72 3269 602 64 8 187 34 6 c) AED excursion 594 0 Envelope loss/gain 13358 7457 644 145 12 a) Infiltration b) Room ventilation 3855 363 428 40 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances @ 1200 0 0 0 0 0 0 Subtotal (lines 6 to 13) 17213 7820 1072 186 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2636 406 0 0 15 Duct loads 28% 48% 19849 5527 8226 3964 28% 48% 1072 299 186 89 Total room load Air required (cfm) 25377 1=2189 1371 275 759 41 1 s Printout certified by ACCA to meet all requirements of Manual J 8th Ed Wt'lghtsOf't Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:41:16 G C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJS Orientation Page 2 1�/rfgl7l5(�f�- System Summa Job: Duct S Y � Date: March 2008 in H2O Entire House By: G M Robertson in H2O Rocky Mountain Contractors Project information For: Lot 25, Henry's Fork Plaza, Suite #3 Rexburg, Id External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.60 in H2O 0.00 in H2O 0.60 in H2O 0.43/0.17 in H2O 0.197 in/100ft 800 cfm 305 ft Suipply Brand Detail Table Cooling 0.60 in H2O 0.00 in H2O 0.60 in H2O 0.43/0.17 in H2O 0.197 in/100ft 800 cfm Supply Trunk Detail Table I Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name Name (Btuh) (cfm) (cfm) FR (in) (in) Mat[ Ln (ft) Ln (ft) Trunk Suite #3-A C 3047 190 196 0.200 7.0 Ox 0 ShMt 46.0 170.0 st2 Suite #3 C 3047 190 196 0.197 7.0 0x0 ShMt 60.0 160.0 st2 Suite #3-B C 3047 190 196 0.221 7.0 Ox 0 ShMt 26.0 170.0 st1 Suite #3-C c 3047 190 196 0.355 7.0 Ox 0 ShMt 17.0 105.0 st1 Lav h 1371 41 18 0.309 6.0 Ox 0 ShMt 25.0 115.0 st2A Supply Trunk Detail Table I Return l3ranch 0e 4ii -- "able Name Trunk Htg Clg Design Veloc Diam H x W Duct Stud/Joist Opening (in) Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 379 391 0.221 885 9.0 0 x 0 RndFbg st2 Peak AVF 421 409 0.197 946 8.7 8 x 8 ShtMetl st2A Peak AVF 41 18 0.309 185 3.3 8 x 4 ShtMetl st2 Return l3ranch 0e 4ii -- "able Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matti Trunk rb1 Ox 0 800 800 85.0 0.197 573 16.0 Ox 0 ShMt rt1 wrjghtsoft Right -Suite Residential 6.0.107 RSR41031 AC( IK C:1My Documents\Wrightsoft HVAMProjects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation 2008 -Mar -18 08:41:17 Page 1 Name Trunk Type HtgClg (cfm) (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk Lrt1 Peak AVF 800 800 0.197 655 11.1 8 x 22 ShtMetl ,, wrightsoft Right -Suite Residential 6.0.107 RSR41031 2008 -Mar -18 08:41:17 jir ,C , C:\My Documents\Wrightsoft HVAC\Projects\Henry's Fork Lot 25 Suite 3.rrp Calc = MJ8 Orientation Page 2