HomeMy WebLinkAboutCOMPLIANCE CERTIFICATES - 08-00118 - 662/674 Tanglewood Dr - New SFRI
Generated by REScheck-Wnh Q^ff- -^
Compliance Cel 08 001 18
662/674 Tan<llewood Dt--TDG
Project Title: Twin Homes, Lot 43
Report Date: 01/25/08
Energy Code:
2003 IECC
0.0
40.0
Location:
Rexburg, Idaho
Wall 1: Wood Frame, 161n. o.c.
408
Construction Type:
Single Family
21
Glazing Area Percentage:
12%
Heating Degree Days:
8693
Low -E
Construction Site:
Owner/Agent:
Designer/Contractor:
Stonebdde Subdivision
15
The Development Group LLC
The Development Group LLC Same as
Rexburg, Idaho 83440
5
PO Box 832
Owner
Rexburg, Idaho 83440
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
6
208-390-0230
0.350
2
scott@bui Itbyldg. cam
Comphance Passes
Compliance: 24.3% Better Than Code
Maximum UA: 321 Your UA: 243
Flat Ceiling or Scissor Truss: Flat or Scissor Truss
1519
0.0
40.0
36
Wall 1: Wood Frame, 161n. o.c.
408
23.0
0.0
21
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
4
0.350
1
Low -E
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
15
0.350
5
Low -E
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
6
0.350
2
Low -E
Wall 2: Wood Frame, 161n. o.c.
128
23.0
0.0
6
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
20
0.350
7
Law -E
Wall 3: Wood Frame, 161n. o.c.
88
23.0
0.0
5
Wall 4: Wood Frame, 16in. o.c.
112
23.0
0.0
5
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
25
0.350
9
Low -E
Wall 5: Wood Frame, 16in. o.c.
32
23.0
0.0
1
Door 1: Solid
21
0.350
7
Wall 6: Wood Frame, 16in, o.c.
104
23.0
0.0
4
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
15
0.350
5
Low -E
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
15
0.350
5
Low -E
Wall 7: Wood Frame, 161n. o.c.
160
19.0
0.0
8
Door 2: Solid
21
0.350
7
Wall 8: Wood Frame, 16in. o.c.
32
19.0
0.0
2
Wall 9: Wood Frame, 16in. o.c.
56
23.0
0.0
2
Door 3: Solid
21
0.350
7
Wall 10: Wood Frame, 161n. o.c.
56
23.0
0.0
3
Wall 11: Wood Frame, thin. o.c.
Wall 12: Wood Frame, 161n. o.c.
®
t 3. a
lt' I .0�
2
Wall 13: Wood Frame, 161n. o.c.
1
23.0
0.
5
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
0 0
7
Low -E
MAn
-6 2008
-
Project Title: Twin Homes Lot 43T f ` �� fi � L'� R port date: 01/25/08
DatOF a filename:
Basement Wall 1: Solid Concrete or Masonry
408
0.0
13.0
20
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Vinyl Frame: Double Pane with Low -E: Vinyl Frame, 2 Pane w/
16
0.350 6
Low -E
Basement Wall 2: Solid Concrete or Masonry
128
0.0
13.0
6
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
16
0.350 6
Low -E
Basement Wall 3: Solid Concrete or Masonry
88
0.0
13.0
4
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 4: Solid Concrete or Masonry
112
0.0
13.0
5
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
12
0.350 4
Low -E
Basement Wall 5: Solid Concrete or Masonry
32
0.0
13.0
2
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 6: Solid Concrete or Masonry
104
0.0
13.0
5
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 7: Solid Concrete or Masonry
160
0.0
13.0
8
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 8: Solid Concrete or Masonry
56
0.0
13.0
3
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 9: Solid Concrete or Masonry
56
0.0
13.0
3
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 10: Solid Concrete or Masonry
24
0.0
13.0
1
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 11: Solid Concrete or Masonry
40
0.0
13.0
2
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 12: Solid Concrete or Masonry
104
0.0
13.0
5
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Furnace 1: Forced Hot Air92 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection
Checklist.
Name - Title
Signature
Dale
Project Title: Twin Homes Lot 43
Report dale: 01/25/08
Data filename:
Page 2 of 7
Date: 01/25/08
Generated by REScheck-Web Software
Inspection Checklist
Ceilings:
❑ Flat Ceiling or Scissor Truss: Flat or Scissor Truss, R-40.0 continuous insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, thin. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 2: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 3: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 4: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 5: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 6: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 7: Wood Frame, 16in. o.c., R-19.0 cavity insulation
Comments:
❑ Wall 6: Wood Frame, 161n. o.c., R-19.0 cavity insulation
Comments:
❑ Wall 9: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 10: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 11: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 12: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 13: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1: Solid Concrete or Masonry, 8.0' hl 17.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 2: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' Insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 3: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Project Title: Twin Homes Lot 43 Report date: 01/25/08
Data filename: Page 3 of 7
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the ea, ,sed (above -grade) insulation and extends
at least 6 in. below grade.
Cl Basement Wall 4: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 5: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 6: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) Insulation and extends
at least 6 in. below grade.
❑ Basement Wall 7: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 8: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 9: Solid Concrete or Masonry, 8.0' ht 17.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 10: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 11: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 12: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
Windows:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes - Frame Type Thermal Break? Yes No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Law -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes - Frame Type Thermal Break? - Yes - No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled 1.1 -factors, describe features:
#Panes -Frame Type Thermal Break? -Yes -No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes - Frame Type Thermal Break? - Yes - No
Comments:
Project Title: Twin Homes Lot 43 Report date: 01/25/08
Data filename: Page 4 of 7
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Law -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? _ Yes — No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -tactor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? _ Yes _ No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
Wanes — Frame Type Thermal Break? — Yes No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? Yes No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? — Yes — No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? — Yes — No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes—Frame Type Thermal Break?—Yes—No
Comments:
Doors:
❑ Door 1: Solid, U -factor: 0.350
Comments:
❑ Door 2: Solid, U -factor: 0.350
Comments:
❑ Door 3: Solid, U -factor: 0.350
Comments:
Heating and Cooling Equipment:
❑ Furnace 1: Forced Hot Air: 92 AFUE or higher
Make and Model Number:
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible
materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches Is RA9.
Vapor Retarder:
❑ Installed on the warm -in -winter side of all non -vented framed ceilings, walls, and floors.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
Project Title: Twin Homes Lot 43 Report dale: 01/25/08
Data filename: Page 5 of 7
Materials and equipment are identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
Insulation R -values, glazing 1.1 -factors, and heating equipment efficiency are clearly marked on the building plans or specifications.
D Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner
that achieves the rated R -value without compressing the insulation.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building are insulated to at least R-11.
Return ducts in unconditioned attics or outside the building are insulated to at least R-6.
Supply ducts in unconditioned spaces are insulated to at least R-11.
Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements.
O Where exterior walls are used as plenums, the wall is insulated to at least R-11.
Duct Construction:
r1 Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened.
❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or
tapes. Tapes and mastics are rated UL 181A or UL 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
Ej The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the healing and/or
cooling input to each zone or floor is provided.
Service Water Heating:
F1 Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
E] Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
Ll All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Project Title: Twin Homes Lot 43 Report date: 01/25/08
Data filename: Page 6 of 7
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Table 2: Minimum Insulation Thickness for HVAC Pipes
Piping System Types
Fluid Temp.
Range(°F)
Insulation Thickness in Inches by Pipe Sizes
Heating Systems
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Up to 1"
Up to 1.25'
1.5" to 2.0"
Over 2"
Temperature ('F)
1.5
2.0
Low Temperature
106-200
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Piping System Types
Fluid Temp.
Range(°F)
Insulation Thickness in Inches by Pipe Sizes
2" Runouts V and Less 1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Project Title: Twin Homes Lot 43
Data filename:
Report date: 01/25/08
Page 7 of 7
Generated by RESchec
Compliance ( 0800118
662i674 Tanglewood Dr-TDG
Project Title: Twin Homes Lot 42
Report Date: 01/25/08
Energy Code:
2003 IECC
0.0
Location:
Rexburg, Idaho
36
Construction Type:
Single Family
23.0
Glazing Area Percentage:
15%
19
Heating Degree Days:
6693
Construction Site:
0.350
Owner/Agent:
Stonebride Subdivision
The Development Group LLC
Rexburg, Idaho 83440
PO Box 832
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
15
Rexburg, Idaho 83440
0.350
208-390-0230
Low -E
soott@builtbytdg.00m
Compliance: Passes
Compliance: 19.6% Better Than Code
Maximum UA: 321 Your LIN 258
Designer/Contractor:
The Development Group LLC Same as
Owner
Flat Ceiling or Scissor Truss: Flat or Scissor Truss
1519
0.0
40.0
36
Wall 1: Wood Frame, 16in. o.c.
408
23.0
0.0
19
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
4
0.350
1
Low -E
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
15
0.350
5
Low -E
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
42
0.350
15
Low -E
Wall 2: Wood Frame, thin. o.c.
128
23.0
0.0
6
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
20
0.350
7
Low -E
Wall 3: Wood Frame, 16in. o.c.
88
23.0
0.0
5
Wall 4: Wood Frame, 16in. o.c.
112
23.0
0.0
5
Vinyl Frame:Double Pane with low -E: Vinyl Frame, 2 Pane wl
15
0.350
5
Low -E
Vinyl Frame: Double Pane with Low -E: Vinyl Frame, 2 Pane w/
15
0.350
5
Low -E
Wall 5: Wood Frame, 16in. o.c.
32
23.0
0.0
1
Door 1: Solid
21
0.350
7
Wall 6: Wood Frame, 16in. o.c.
104
23.0
0.0
4
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
15
0.350
5
Low -E
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
15
0.350
5
Low -E
Wall 7: Wood Frame, 16in. o.c.
160
19.0
0.0
8
Door 2: Solid
21
0.350
7
Wall 8: Wood Frame, 161n. o.c.
32
19.0
0.0
2
Wall 9: Wood Frame, 161n. o.c.
56
23.0
0.0
2
Door 3: Solid
21
0.350
7
Wall 10: Wood Frame, 161n. o.c.
56
23.0
0.0
3
Wall 11: Wood Frame, 161n. o.c.
24
23.0
0.0
1
Wall 12: Wood Frame, 16in. o.c.
40
23.0
0.0
2
Wall 13: Wood Frame, 161n. o.c.
104
23.0
0.0
5
Project Title: Twin Homes Lot 42
Data filename:
Report date: 01/25/08
Page 1 of 7
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
Low -E
Basement Wall 1: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
Low -E
Basement Wall 2: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
Low -E
Basement Wall 3: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 4: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
Low -E
Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/
Low -E
Basement Wall 5: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 6: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: SA'
Basement Wall 7: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 8: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 9: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 10: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 11: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Basement Wall 12: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Furnace 1: Forced Hot Air92 AFUE
20
0.350
7
408
0.0
13.0
20
16
0.350
6
128
0.0
13.0
6
16
0.350
6
88
0.0
13.0
4
112
0.0
13.0
4
12
0.350
4
12
0.350
4
32
0.0
13.0
2
104
0.0
13.0
5
160
0.0
13.0
8
56
0.0
13.0
3
56
0.0
13.0
3
24
0.0
13.0
1
40
0.0
13.0
2
104
0.0
13.0
5
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Title: Twin Homes Lot 42 Report date: 01/25/08
Data filename: Page 2 of 7
rGenerated by REScheck-Web Software
�(, Inspection Checklist
Date: 01/25/08
Ceilings:
❑ Flat Ceiling or Scissor Truss: Flat or Scissor Truss, R-40.0 continuous insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 2: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 3: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 4: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 5: Wood Frame, 161n. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 6: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 7: Wood Frame, 16in. o.c., R-19.0 cavity insulation
Comments:
Cl Wall 8: Wood Frame, 161n. o.c., R-19.0 cavity Insulation
Comments:
Cl Wall 9: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 10: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 11: Wood Frame, thin. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 12: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
❑ Wall 13: Wood Frame, 16in. o.c., R-23.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1: Solid Concrete or Masonry, 8.0' ht 17.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant prolective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 2: Solid Concrete or Masonry, 8.0' hl / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 3: Solid Concrete or Masonry, 8.0' hl 17.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
-------------------------... _. _. _.. __. Project Title: Title: Twin Homes Lot 42 Report date: 01/25/08
Data filename: Page 3 of 7
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
Cl Basement Wall 4: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 5: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 6: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 7: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 8: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 9: Solid Concrete or Masonry, 8.0' hl / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 10: Solid Concrete or Masonry, 8.0' ht / 7.0' bg 18.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 11: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
❑ Basement Wall 12: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends
at least 6 in. below grade.
Windows:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
Wanes Frame Type Thermal Break? _ Yes No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled 1.1 -factors, describe features:
#Panes - Frame Type Thermal Break? - Yes - No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled 1.1 -factors, describe features:
#Panes - Frame Type Thermal Break? - Yes - No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled 1.1 -factors, describe features:
#Panes Frame Type Thermal Break? _ Yes No
Comments:
Project Title: Twin Homes Lot 42 Report date: 01/25/08
Data filename: Page 4 of 7
❑ Vinyl Frame:Double Pane with Lo.. -c: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes—Frame Type Thermal Break?—Yes—No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? Yes No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? _ Yes _ No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled 1.1 -factors, describe features:
#Panes Frame Type Thermal Break? —Yes — No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? — Yes — No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -tactor: 0.350
For windows without labeled U -factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, 1.1 -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes _ Frame Type Thermal Break? Yes — No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes—Frame Type Thermal Break? Yes No
Comments:
❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350
For windows without labeled U -factors, describe features:
#Panes — Frame Type Thermal Break? — Yes — No
Comments:
Doors:
❑ Door 1: Solid, U -factor: 0.350
Comments:
❑ Door 2: Solid, U -factor: 0.350
Comments:
❑ Door 3: Solid, U -factor: 0.350
Comments:
Heating and Cooling Equipment:
❑ Furnace 1: Forced Hot Air: 92 AFUE or higher
Make and Model Number:
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5' clearance from combustible
materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Project Title: Twin Homes Lot 42 Report date: 01/25/08
Data filename: Page 5 of 7
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19.
Vapor Retarder:
❑ Installed on the warm -in -winter side of all non -vented framed ceilings, walls, and Floors.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
Materials and equipment are identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
Insulation R -values, glazing U -factors, and heating equipment efficiency are clearly marked on the building plans or specifications.
Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner
that achieves the rated R -value without compressing the insulation.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building are insulated to at least R-11.
Return ducts in unconditioned attics or outside the building are insulated to at least R-6.
Supply duds in unconditioned spaces are insulated to at least R-11.
Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements.
Where exterior walls are used as plenums, the wall is insulated to at least R-11.
Duct Construction:
C] Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened.
C] All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or
tapes. Tapes and mastics are rated UL 181A or UL 1818.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
Lj The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
O Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or Floor is provided.
Service Water Heating:
Li Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is pan of a circulating system.
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
O All healed swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
O HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Project Titie: Twin Homes Lot 42 Report date: 01/25/08
Data filename: Page 6 of 7
I
Table 1: Minimum Insulation, ,hickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water Up to 1" Up to 1.25'
Temperature ("F)
1.5' to 2.0" Over 2"
170-180 0.5 1.0
1.5 2.0
140-169 0.5 0.5
1.0 1.5
100-139 0.5 0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for
HVAC Pipes
Low Temperature
Insulation Thickness in Inches by Pipe Sizes
Fluid Temp.
1.0
Piping System Types oma. -Pr l
2" Runouts 1"and Less 1.25' to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Project Title: Twin Homes Lot 42 Report date: 01/25/08
Data filename: Page 7 of 7