Loading...
HomeMy WebLinkAboutCOMPLIANCE CERTIFICATES - 08-00118 - 662/674 Tanglewood Dr - New SFRI Generated by REScheck-Wnh Q^ff- -^ Compliance Cel 08 001 18 662/674 Tan<llewood Dt--TDG Project Title: Twin Homes, Lot 43 Report Date: 01/25/08 Energy Code: 2003 IECC 0.0 40.0 Location: Rexburg, Idaho Wall 1: Wood Frame, 161n. o.c. 408 Construction Type: Single Family 21 Glazing Area Percentage: 12% Heating Degree Days: 8693 Low -E Construction Site: Owner/Agent: Designer/Contractor: Stonebdde Subdivision 15 The Development Group LLC The Development Group LLC Same as Rexburg, Idaho 83440 5 PO Box 832 Owner Rexburg, Idaho 83440 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 6 208-390-0230 0.350 2 scott@bui Itbyldg. cam Comphance Passes Compliance: 24.3% Better Than Code Maximum UA: 321 Your UA: 243 Flat Ceiling or Scissor Truss: Flat or Scissor Truss 1519 0.0 40.0 36 Wall 1: Wood Frame, 161n. o.c. 408 23.0 0.0 21 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 4 0.350 1 Low -E Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 15 0.350 5 Low -E Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 6 0.350 2 Low -E Wall 2: Wood Frame, 161n. o.c. 128 23.0 0.0 6 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 20 0.350 7 Law -E Wall 3: Wood Frame, 161n. o.c. 88 23.0 0.0 5 Wall 4: Wood Frame, 16in. o.c. 112 23.0 0.0 5 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 25 0.350 9 Low -E Wall 5: Wood Frame, 16in. o.c. 32 23.0 0.0 1 Door 1: Solid 21 0.350 7 Wall 6: Wood Frame, 16in, o.c. 104 23.0 0.0 4 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 15 0.350 5 Low -E Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 15 0.350 5 Low -E Wall 7: Wood Frame, 161n. o.c. 160 19.0 0.0 8 Door 2: Solid 21 0.350 7 Wall 8: Wood Frame, 16in. o.c. 32 19.0 0.0 2 Wall 9: Wood Frame, 16in. o.c. 56 23.0 0.0 2 Door 3: Solid 21 0.350 7 Wall 10: Wood Frame, 161n. o.c. 56 23.0 0.0 3 Wall 11: Wood Frame, thin. o.c. Wall 12: Wood Frame, 161n. o.c. ® t 3. a lt' I .0� 2 Wall 13: Wood Frame, 161n. o.c. 1 23.0 0. 5 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 0 0 7 Low -E MAn -6 2008 - Project Title: Twin Homes Lot 43T f ` �� fi � L'� R port date: 01/25/08 DatOF a filename: Basement Wall 1: Solid Concrete or Masonry 408 0.0 13.0 20 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Vinyl Frame: Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 16 0.350 6 Low -E Basement Wall 2: Solid Concrete or Masonry 128 0.0 13.0 6 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 16 0.350 6 Low -E Basement Wall 3: Solid Concrete or Masonry 88 0.0 13.0 4 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 4: Solid Concrete or Masonry 112 0.0 13.0 5 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 12 0.350 4 Low -E Basement Wall 5: Solid Concrete or Masonry 32 0.0 13.0 2 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 6: Solid Concrete or Masonry 104 0.0 13.0 5 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 7: Solid Concrete or Masonry 160 0.0 13.0 8 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 8: Solid Concrete or Masonry 56 0.0 13.0 3 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 9: Solid Concrete or Masonry 56 0.0 13.0 3 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 10: Solid Concrete or Masonry 24 0.0 13.0 1 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 11: Solid Concrete or Masonry 40 0.0 13.0 2 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 12: Solid Concrete or Masonry 104 0.0 13.0 5 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Furnace 1: Forced Hot Air92 AFUE Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Dale Project Title: Twin Homes Lot 43 Report dale: 01/25/08 Data filename: Page 2 of 7 Date: 01/25/08 Generated by REScheck-Web Software Inspection Checklist Ceilings: ❑ Flat Ceiling or Scissor Truss: Flat or Scissor Truss, R-40.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, thin. o.c., R-23.0 cavity insulation Comments: ❑ Wall 2: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 3: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 4: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 5: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 6: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 7: Wood Frame, 16in. o.c., R-19.0 cavity insulation Comments: ❑ Wall 6: Wood Frame, 161n. o.c., R-19.0 cavity insulation Comments: ❑ Wall 9: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 10: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 11: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 12: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 13: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1: Solid Concrete or Masonry, 8.0' hl 17.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 2: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' Insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 3: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Project Title: Twin Homes Lot 43 Report date: 01/25/08 Data filename: Page 3 of 7 Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the ea, ,sed (above -grade) insulation and extends at least 6 in. below grade. Cl Basement Wall 4: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 5: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 6: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) Insulation and extends at least 6 in. below grade. ❑ Basement Wall 7: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 8: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 9: Solid Concrete or Masonry, 8.0' ht 17.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 10: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 11: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 12: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. Windows: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes - Frame Type Thermal Break? Yes No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Law -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes - Frame Type Thermal Break? - Yes - No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled 1.1 -factors, describe features: #Panes -Frame Type Thermal Break? -Yes -No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes - Frame Type Thermal Break? - Yes - No Comments: Project Title: Twin Homes Lot 43 Report date: 01/25/08 Data filename: Page 4 of 7 ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Law -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? _ Yes — No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -tactor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? _ Yes _ No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: Wanes — Frame Type Thermal Break? — Yes No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? Yes No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? — Yes — No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? — Yes — No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes—Frame Type Thermal Break?—Yes—No Comments: Doors: ❑ Door 1: Solid, U -factor: 0.350 Comments: ❑ Door 2: Solid, U -factor: 0.350 Comments: ❑ Door 3: Solid, U -factor: 0.350 Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 92 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches Is RA9. Vapor Retarder: ❑ Installed on the warm -in -winter side of all non -vented framed ceilings, walls, and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. Project Title: Twin Homes Lot 43 Report dale: 01/25/08 Data filename: Page 5 of 7 Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Insulation R -values, glazing 1.1 -factors, and heating equipment efficiency are clearly marked on the building plans or specifications. D Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the insulation. Duct Insulation: Supply ducts in unconditioned attics or outside the building are insulated to at least R-11. Return ducts in unconditioned attics or outside the building are insulated to at least R-6. Supply ducts in unconditioned spaces are insulated to at least R-11. Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements. O Where exterior walls are used as plenums, the wall is insulated to at least R-11. Duct Construction: r1 Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened. ❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ej The HVAC system provides a means for balancing air and water systems. Temperature Controls: Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the healing and/or cooling input to each zone or floor is provided. Service Water Heating: F1 Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Lj Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: E] Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: Ll All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: Twin Homes Lot 43 Report date: 01/25/08 Data filename: Page 6 of 7 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Fluid Temp. Range(°F) Insulation Thickness in Inches by Pipe Sizes Heating Systems Non -Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25' 1.5" to 2.0" Over 2" Temperature ('F) 1.5 2.0 Low Temperature 106-200 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Fluid Temp. Range(°F) Insulation Thickness in Inches by Pipe Sizes 2" Runouts V and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Project Title: Twin Homes Lot 43 Data filename: Report date: 01/25/08 Page 7 of 7 Generated by RESchec Compliance ( 0800118 662i674 Tanglewood Dr-TDG Project Title: Twin Homes Lot 42 Report Date: 01/25/08 Energy Code: 2003 IECC 0.0 Location: Rexburg, Idaho 36 Construction Type: Single Family 23.0 Glazing Area Percentage: 15% 19 Heating Degree Days: 6693 Construction Site: 0.350 Owner/Agent: Stonebride Subdivision The Development Group LLC Rexburg, Idaho 83440 PO Box 832 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 15 Rexburg, Idaho 83440 0.350 208-390-0230 Low -E soott@builtbytdg.00m Compliance: Passes Compliance: 19.6% Better Than Code Maximum UA: 321 Your LIN 258 Designer/Contractor: The Development Group LLC Same as Owner Flat Ceiling or Scissor Truss: Flat or Scissor Truss 1519 0.0 40.0 36 Wall 1: Wood Frame, 16in. o.c. 408 23.0 0.0 19 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 4 0.350 1 Low -E Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 15 0.350 5 Low -E Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 42 0.350 15 Low -E Wall 2: Wood Frame, thin. o.c. 128 23.0 0.0 6 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 20 0.350 7 Low -E Wall 3: Wood Frame, 16in. o.c. 88 23.0 0.0 5 Wall 4: Wood Frame, 16in. o.c. 112 23.0 0.0 5 Vinyl Frame:Double Pane with low -E: Vinyl Frame, 2 Pane wl 15 0.350 5 Low -E Vinyl Frame: Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 15 0.350 5 Low -E Wall 5: Wood Frame, 16in. o.c. 32 23.0 0.0 1 Door 1: Solid 21 0.350 7 Wall 6: Wood Frame, 16in. o.c. 104 23.0 0.0 4 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 15 0.350 5 Low -E Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ 15 0.350 5 Low -E Wall 7: Wood Frame, 16in. o.c. 160 19.0 0.0 8 Door 2: Solid 21 0.350 7 Wall 8: Wood Frame, 161n. o.c. 32 19.0 0.0 2 Wall 9: Wood Frame, 161n. o.c. 56 23.0 0.0 2 Door 3: Solid 21 0.350 7 Wall 10: Wood Frame, 161n. o.c. 56 23.0 0.0 3 Wall 11: Wood Frame, 161n. o.c. 24 23.0 0.0 1 Wall 12: Wood Frame, 16in. o.c. 40 23.0 0.0 2 Wall 13: Wood Frame, 161n. o.c. 104 23.0 0.0 5 Project Title: Twin Homes Lot 42 Data filename: Report date: 01/25/08 Page 1 of 7 Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E Basement Wall 1: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E Basement Wall 2: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E Basement Wall 3: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 4: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E Basement Wall 5: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 6: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: SA' Basement Wall 7: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 8: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 9: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 10: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 11: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 12: Solid Concrete or Masonry Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Furnace 1: Forced Hot Air92 AFUE 20 0.350 7 408 0.0 13.0 20 16 0.350 6 128 0.0 13.0 6 16 0.350 6 88 0.0 13.0 4 112 0.0 13.0 4 12 0.350 4 12 0.350 4 32 0.0 13.0 2 104 0.0 13.0 5 160 0.0 13.0 8 56 0.0 13.0 3 56 0.0 13.0 3 24 0.0 13.0 1 40 0.0 13.0 2 104 0.0 13.0 5 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: Twin Homes Lot 42 Report date: 01/25/08 Data filename: Page 2 of 7 rGenerated by REScheck-Web Software �(, Inspection Checklist Date: 01/25/08 Ceilings: ❑ Flat Ceiling or Scissor Truss: Flat or Scissor Truss, R-40.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 2: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 3: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 4: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 5: Wood Frame, 161n. o.c., R-23.0 cavity insulation Comments: ❑ Wall 6: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 7: Wood Frame, 16in. o.c., R-19.0 cavity insulation Comments: Cl Wall 8: Wood Frame, 161n. o.c., R-19.0 cavity Insulation Comments: Cl Wall 9: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 10: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 11: Wood Frame, thin. o.c., R-23.0 cavity insulation Comments: ❑ Wall 12: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: ❑ Wall 13: Wood Frame, 16in. o.c., R-23.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1: Solid Concrete or Masonry, 8.0' ht 17.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant prolective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 2: Solid Concrete or Masonry, 8.0' hl / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 3: Solid Concrete or Masonry, 8.0' hl 17.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: -------------------------... _. _. _.. __. Project Title: Title: Twin Homes Lot 42 Report date: 01/25/08 Data filename: Page 3 of 7 Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. Cl Basement Wall 4: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 5: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 6: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 7: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 8: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 9: Solid Concrete or Masonry, 8.0' hl / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 10: Solid Concrete or Masonry, 8.0' ht / 7.0' bg 18.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 11: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. ❑ Basement Wall 12: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 continuous insulation Comments: Exterior insulation has a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. Windows: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: Wanes Frame Type Thermal Break? _ Yes No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled 1.1 -factors, describe features: #Panes - Frame Type Thermal Break? - Yes - No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled 1.1 -factors, describe features: #Panes - Frame Type Thermal Break? - Yes - No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled 1.1 -factors, describe features: #Panes Frame Type Thermal Break? _ Yes No Comments: Project Title: Twin Homes Lot 42 Report date: 01/25/08 Data filename: Page 4 of 7 ❑ Vinyl Frame:Double Pane with Lo.. -c: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes—Frame Type Thermal Break?—Yes—No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? Yes No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? _ Yes _ No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled 1.1 -factors, describe features: #Panes Frame Type Thermal Break? —Yes — No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? — Yes — No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -tactor: 0.350 For windows without labeled U -factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, 1.1 -factor: 0.350 For windows without labeled U -factors, describe features: #Panes _ Frame Type Thermal Break? Yes — No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes—Frame Type Thermal Break? Yes No Comments: ❑ Vinyl Frame:Double Pane with Low -E: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? — Yes — No Comments: Doors: ❑ Door 1: Solid, U -factor: 0.350 Comments: ❑ Door 2: Solid, U -factor: 0.350 Comments: ❑ Door 3: Solid, U -factor: 0.350 Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 92 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5' clearance from combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation. Project Title: Twin Homes Lot 42 Report date: 01/25/08 Data filename: Page 5 of 7 Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: ❑ Installed on the warm -in -winter side of all non -vented framed ceilings, walls, and Floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Insulation R -values, glazing U -factors, and heating equipment efficiency are clearly marked on the building plans or specifications. Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the insulation. Duct Insulation: Supply ducts in unconditioned attics or outside the building are insulated to at least R-11. Return ducts in unconditioned attics or outside the building are insulated to at least R-6. Supply duds in unconditioned spaces are insulated to at least R-11. Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements. Where exterior walls are used as plenums, the wall is insulated to at least R-11. Duct Construction: C] Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened. C] All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics are rated UL 181A or UL 1818. Exceptions: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Lj The HVAC system provides a means for balancing air and water systems. Temperature Controls: O Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or Floor is provided. Service Water Heating: Li Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is pan of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: O All healed swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: O HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Titie: Twin Homes Lot 42 Report date: 01/25/08 Data filename: Page 6 of 7 I Table 1: Minimum Insulation, ,hickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25' Temperature ("F) 1.5' to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Low Temperature Insulation Thickness in Inches by Pipe Sizes Fluid Temp. 1.0 Piping System Types oma. -Pr l 2" Runouts 1"and Less 1.25' to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Project Title: Twin Homes Lot 42 Report date: 01/25/08 Data filename: Page 7 of 7