HomeMy WebLinkAboutCOMCHECK - 08-00114 - Delta Phi Apartments - Roof RemodelJ COMcheck Software Vel
Exterior Lightin
Certificate
08 001 1 4
Delta Phi Apartments
Roof Remodel
2006IECC FMA:fl
_Report Date: 03/05/08 �SData filename: Untitled.cck L,Section 1: Project Information --6 2008 /
Project Type: Addition
f--
Project Title: Delta Phi Appartments
CITY OF RFXBURG
Construction Site:
Owner/Agent:
Designer/Contractor: ---__
139 Viking Drive
Jim Dayley
Anthony Merrill
Rexburg , ID 83440
1071 S. 7th E.
Merrill Construction LLC.
Sugar City, ID 83448
1322 N. 16th E.
356-4769
Sugar City, ID 83448
351-1801
mcbuld4u@ida.net
Section 2: Exterior Lighting
Area/Surface Power Calculation
A
Exterior Area/Surface
B C D E F
Quantity Allowed Tradable Allowed Proposed
Watts Wattage Wafts Watts
Attached canopy 312 U 1.25 Yes 390 78
Total Tradable Watts` = 390 78
Total Allowed Watts = 390
Total Allowed Supplemental Watts— = 20
Wattage tradeoffs are only allowed between tradable areas/surfaces.
"A supplemental allowance equal to 5% of total allowed wattage may be applied toward compliance of both non -tradable and tradable
areas/surfaces.
Section 3: Exterior Lighting Fixture Schedule
A B C D E
Fixture ID : Description I Lamp I Wattage Per Lamp I Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
Attached canopy (312 ft2): Tradable Wattage
Compact Fluorescent 1: Spiral 26W/ Electronic 1 3 26 78
Total Tradable Proposed Watts = 78
Section 4: Requirements Checklist
Lighting Wattage:
1. Within each non -tradable area/surface, total proposed watts must be less than or equal to total allowed watts. Across all tradable
areas/surfaces, total proposed watts must be less than or equal to total allowed watts.
Compliance: Passes.
Controls, Switching, and Wiring:
2. All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting.
❑ 3. All nonexempt lighting fixtures shall be controlled by a photosensor or astronomical time switch that is capable of automatically turning
off the fixture when sifficient daylight is available or the lighting is not required.
Exterior Lighting Efficacy:
Project Title: Delta Phi Appartments Report date: 03/05/08
Data filename: Untitled.cck Page 1 of 2
' ri 4. All exterior building grounds lur as that operate at greater than 100W have minimum acy of 60 lumen/watt..
Exceptions:
Controlled by motion sensor or exempt from consideration under the provisions of Section 505.6.2.
Exterior Lighting PASSES: Design 80% better than code.
Section 5: Compliance Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2006 IECC
requirements in COMcheck Version 3.5.2 and to comply with the mandatory requirements in the Requirements Checklist.
Name - Title
Project Title: Delta Phi Appartmenls
Data filename: Untilled.ock
Signature Date
Report date: 03/05/08