Loading...
HomeMy WebLinkAboutENGINEERING CALCS - 04 Variance - 1175 Main Street - Sign HeightDesign Intelligence Engineering Calculations Summary Date: January 2, 2004 Subject: Valley Wide Coop Sign, Rexburg, Idaho Customer: Valley Wide Coop, Rexburg, Idaho Abstract The customer provided drawings of the sign. This analysis uses the Design Criteria required by the local jurisdiction and the 1997 UBC as the basis for the calculations. Materials: A36 Steel - Fy=36,000 psi Concrete: 3000 psi @ 28 days Reinforcing Steel - fy = 60,000 psi Assumptions: International Building Code 2000 Design Loads: Snow = N/A Seismic = N/A Wind = 90 mph, Exposure C References: International Building Code 2000on These calculations and included details are for Customer Drawings this location and customer only and not to be reused in any manner without the written Summary: consent of Design Intelligence. The sign requires (2) TS l0x10xl/4 steel posts as noted on the attached drawing. The steel posts are to extend to the bottom of the footings. The individual footing dimensions are 48" parallel to the face of the sign, 7'6" perpendicular to the face of the sign and 72" deep. Reinforce the footings with two mats of #4 bars at 12" o -c. each way. Mats are to be located 3" from the top of the footing and 3" up from the bottom of the footing. See also vertical and stirrup reinforcing noted on the drawing. Designed Py .4 Stott A Spaulding, PF. I Checked Date: nom, Date: Design Intelligence VALLEY WIDE COOP 1/2/2004 3685 W Hwy 33 AMERICAN FALLS, IDAHO Rexbura. Idaho 83440 Materials A500 Grade B Steel Fy = 42000 psi Wind Loading cis P=Ce*Cq*qs*lw qs = Iw = 70 mph 12.6 16.4 psf Ce = Cq = 1 IF - 80 mph 90 mph 16.4 20.8 1.06 Exposure C 1.4 Horizontal Ph = 24.3 psf (Horizontal) Sign Data Description 0 ft - 40ft Phillips Sign Hot Stuff Sign Gas Prices Sign Sign #4 Total Pipe Moment Footing Design Width in. Height in. 108 85 108 26 108 73 108 26 Soil Wt. 110 L ft B ft T ft CG in. Force Ibs. Moment Ib -in 437.5 1552 678791 368 475 174647 304.5 1332 405741 252 475 119595 1378774 Single Post Load = 689387 pcf Weight Ibs. 4 7.5 6 27000 Resisting Moment = 101250 Ib -ft Passive Earth Moment = 15125115-ft- 5125Ib-ftOverturning OverturningMoment = 68948 Ib -ft Design Factor of Safety Against Overturning = 1.5 Factor of Safety = 1.69 OK Single Post Size S Req'd ISProvided Dia Wall Oft -:25 ft 24.87 30.1 OK TS10x10x1/4 0.25 Page 1 NOT STUFF P I Z Z Am Rexburg Highway 20 Business Pole Signs A d. . Sy �t Mother Hibbard's Country Store 11 North 2000 West Pole Sign Height: 40 Feet Above Grade Valley Wide Coop 1175 West Main Pole Sign Height: 24 Feet Above Grade Cheveron/Burger King Food Mart 1874 West 1500 South Pole Sign Height: 25 Feet Above Grade To The Top Of Burger King Sign ComFort Inn 1565 West Main Pole Sign Height: 60 Feet Above Grade