HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 08-00112 - 805 Johnson - New SFRREScheck Compliance Certificate
2000 IECC
RES checkSoftware Version 3.6 Release 1
Data filename: C:\Program Files\Check\REScheck\Spec #18.rck
PROJECT TITLE: Spec #18
CITY: Rexburg
STATE: Idaho
HDD: 8693
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.14
DATE: 02/22/08
DATE OF PLANS: May 17, 2007
PROJECT DESCRIPTION:
Single Family Dwelling
DESIGNERICONTRACTOR:
JB KAY
COMPLIANCE: Passes
Maximum UA = 416
Your Home UA = 271
34.9% Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Vinyl Frame:Double Pane with Low -E
Door 1: Solid
Crawl 1: Solid Concrete or Masonry
Wall height: 4.0'
Depth below grade: 3.0'
Insulation depth: 4.0'
Furnace 1: Forced Hot Air, 93 AFUE
Air Conditioner 1: Electric Central Air, 10 SEER
0800112
805 Johnson -Harris
Checked By/Date
e OF REXB!;i
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R -Value R -Value U -Factor U&
1590
0.0 38.0 40
1724
21.0 0.0 84
237
0.350 83
20
0.240 5
862
0.0 11.0 59
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 (formerly MECchec)� and to comply with the
mandatory requirements listed in the RES checkInspection Checklist.
Builder/Designer