Loading...
HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 08-00112 - 805 Johnson - New SFRREScheck Compliance Certificate 2000 IECC RES checkSoftware Version 3.6 Release 1 Data filename: C:\Program Files\Check\REScheck\Spec #18.rck PROJECT TITLE: Spec #18 CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.14 DATE: 02/22/08 DATE OF PLANS: May 17, 2007 PROJECT DESCRIPTION: Single Family Dwelling DESIGNERICONTRACTOR: JB KAY COMPLIANCE: Passes Maximum UA = 416 Your Home UA = 271 34.9% Better Than Code (UA) Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Vinyl Frame:Double Pane with Low -E Door 1: Solid Crawl 1: Solid Concrete or Masonry Wall height: 4.0' Depth below grade: 3.0' Insulation depth: 4.0' Furnace 1: Forced Hot Air, 93 AFUE Air Conditioner 1: Electric Central Air, 10 SEER 0800112 805 Johnson -Harris Checked By/Date e OF REXB!;i Gross Glazing Area or Cavity Cont. or Door Perimeter R -Value R -Value U -Factor U& 1590 0.0 38.0 40 1724 21.0 0.0 84 237 0.350 83 20 0.240 5 862 0.0 11.0 59 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 (formerly MECchec)� and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer