Loading...
HomeMy WebLinkAboutCHECKLIST - 08-00104 - Snellgrove Townhomes - Bldg 9, 4 Units1 RESIDENTIAL PLAN CHECKLIST (2003 International Residential Code) Date: / f Building Permit Number: O 'i— y5o Kd 'M Project: 9e„d ,s �, �d f re,0�r rel 5 Job Address: Zoning: dd t I Number of Stories: A_ Basement:es o / Fin. (Partial: so (Note unfinished base nts as special condition on permit) Floor Area (sf): JIV finished, ___4tgounfinished, garage The following comments based on the 2003 edition of the International Residential Code should be resolved before a building permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International Residential Code or any federal, state or local regulations. PLAN CHECK A. Plans o"To Scale /Legible iPlot Plan Y /011ood Plain ../Floor / Foundation Plan Section showing construction details /All Building Elevations Design Criteria (shall be identified on plans as Wind - 85 m.p.h.; Snow - 35 lb. Per sq ft.) Truss Calculation Sheetsloor Joist Details (2�4echanical Design & Heat Load calc's Energy Calculations (8320 & Ch 11) B. Zoning (circle one) LDRl 12,000 sf min. (width 80 ft. min) LDR2 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P. RR2 21,780 sf min. (width 150 ft min) -Duplex allowed with C.U.P. Other M.,d R I (Verify zoning requirements) r l I. } Floor Sheathing (3/4" min for joists 24" oc & 5/8" for joists 16" oc) R503.2.2 Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602.3 % Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) / Rafter and Truss tie -downs. (1180210.5) Attic Access 22" x 30 min. rough opening (8807) H. Exterior Covering /"Masonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1 I. Roof Covering and Ventilation ,--'Roof Ventilation as per R806 ,--Asphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905.__) J. Firewalls -Crarage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2 _Deer-4em Garage to House (13/8" solid wood or steel door, or 20 min. fire -rated door) R309.1 _TTvu-FamiI7Dwelling Separation (1 hr fire separation) Supporting structure also rated. R317.1 k""Twin homesTownhouses 2 hr separation & 4' overbum protection or parapet) R317.2 - s p lel to and within 3 ft of property line w/ NO openings allowed. R302 /Penetrations in previous 3 items to comply with R317:3 K. general Requirements House Numbers R321 Zalf Openable 3sf window or Mech. Ventilation in bathrooms, water closets, and similar rooms. R303.3 /' nterior and exterior stair illumination shall comply with 8303.6. /Bathroom Fixture clearances comply with Figure R307.2 _/One room at least 120 s£; /Other habitable rooms 70 sf min w/ a min. dimension of 7 ft. R304 *areas w/sloped ceilings less than 5 fl in height & furred ceilings less than 7 fi DO NOT comply *50% or more of the required area must be at least 7ft high in rooms w/sloped ceiling