Loading...
HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 08-00099 - 248 Rebecca Drive - New SFRCREScheck Software Versio �(J Compliance Cei Project Title: Lees Residence Rexburg Report Date: 02/26/08 Data filename: C:\Program files\Check\REScheck\Lees Residence Rexburg.rck Energy Code: 2006 IECC Location: Rexburg, Idaho Construction Type: Single Family Builidng Orientation: Bldg. faces 0 deg. from North Conditioned Floor Area: 1329 1ft2 Glazing Area Percentage: 17% Heating Degree Days: 8693 Climate Zone: 6 I 0800099 248 Rebecca Dr -Lees FEB 2 6 2008 I!__., CITY OF REXBURG Construction Site: Owner/Agent: Designer/Contractor: Lee Compliance: 2.7% Better Than Code vvaii r vvooa rrame, lb o.c. 368 21.0 0.0 14 Orientation: Front Door 1: Glass 41 0.350 14 SHGC: 0.66 Orientation: Front Window 1: Other:Double Pane with Low -E 80 0.350 28 SHGC: 0.29 Orientation: Front Wall 2: Wood Frame, 16" o.c. 312 21.0 0.0 17 Orientation: Right Side Door 1: Solid 21 0.350 7 Orientation: Left Side Wall 3: Wood Frame, 16" o.c. 368 21.0 0.0 16 Orientation: Back Door 1: Solid 21 0.350 7 Orientation: Left Side Window 1: Other:Double Pane with Low -E 73 0.350 25 SHGC: 0.29 Orientation: Back Wall 4: Wood Frame, 16" o.c. 312 21.0 0.0 17 Orientation: Left Side Window 1: Other:Double Pane with Low -E 12 0.350 4 SHGC: 0.29 Orientation: Left Side Basement Wall 1: Solid Concrete or Masonry ow 11.0 0.0 24 Orientation: Front Wall height: 8.0' Depth below grade: 6.0' - Insulation depth: 8.0' Window 1: Other:Double Pane with Low -E 32 0.350 11 SHGC: 0.29 Orientation: Front Basement Wall 2: Solid Concrete or Masonry go 11.0 0.0 22 Orientation: Right Side Wall height: 8.0' Depth below grade: 6.0' Project Title: Lees Residence Rexburg Report date: 02/26/08 Data filename: C:\Program files\Check\REScheck\Lees Residence Rexburg.rck Page 1 of 2 Insulation depth: 8.0' Basement Wall 3: Solid Concrete or Masonry§Q41^ 11.0 0.0 26 Orientation: Back Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Basement Wall 4: Solid Concrete or Masonry 11.0 0.0 22 Orientation: Left Side Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Ceiling 1: Flat Ceiling or Scissor Truss 1329 44.0 0.0 36 Air Conditioner 1: Electric Central Air13 SEER Furnace 1: Forced Hot Ah -93 AFUE Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in REScheck Version 4.1.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Notes: Job Number: Project Title: Lees Residence Rexburg Report date: 02/26/08 Data filename: C:\Program files\Check\REScheck\Lees Residence Rexburg.rck Page 2 of 2 KEner2006 IECC E gy yv Efficiency Certificate Calling I Roof 44.00 Wall 21.00 Floor I Foundation 11.00 Ductwork (unconditioned spaces: D.. Window 0.35 0.29 Door 0.35 0.66 Electric Central Air Conditioner 13 SEER Forced Hot Air Furnace 93AFUE Water Heater: Name: Date: Comments: