HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 08-00099 - 248 Rebecca Drive - New SFRCREScheck Software Versio
�(J Compliance Cei
Project Title: Lees Residence Rexburg
Report Date: 02/26/08
Data filename: C:\Program files\Check\REScheck\Lees Residence Rexburg.rck
Energy Code:
2006 IECC
Location:
Rexburg, Idaho
Construction Type:
Single Family
Builidng Orientation:
Bldg. faces 0 deg. from North
Conditioned Floor Area:
1329 1ft2
Glazing Area Percentage:
17%
Heating Degree Days:
8693
Climate Zone:
6
I
0800099
248 Rebecca Dr -Lees
FEB 2 6 2008 I!__.,
CITY OF REXBURG
Construction Site: Owner/Agent: Designer/Contractor:
Lee
Compliance: 2.7% Better Than Code
vvaii r vvooa rrame, lb o.c.
368
21.0
0.0
14
Orientation: Front
Door 1: Glass
41
0.350
14
SHGC: 0.66
Orientation: Front
Window 1: Other:Double Pane with Low -E
80
0.350
28
SHGC: 0.29
Orientation: Front
Wall 2: Wood Frame, 16" o.c.
312
21.0
0.0
17
Orientation: Right Side
Door 1: Solid
21
0.350
7
Orientation: Left Side
Wall 3: Wood Frame, 16" o.c.
368
21.0
0.0
16
Orientation: Back
Door 1: Solid
21
0.350
7
Orientation: Left Side
Window 1: Other:Double Pane with Low -E
73
0.350
25
SHGC: 0.29
Orientation: Back
Wall 4: Wood Frame, 16" o.c.
312
21.0
0.0
17
Orientation: Left Side
Window 1: Other:Double Pane with Low -E
12
0.350
4
SHGC: 0.29
Orientation: Left Side
Basement Wall 1: Solid Concrete or Masonry
ow
11.0
0.0
24
Orientation: Front
Wall height: 8.0'
Depth below grade: 6.0' -
Insulation depth: 8.0'
Window 1: Other:Double Pane with Low -E
32
0.350
11
SHGC: 0.29
Orientation: Front
Basement Wall 2: Solid Concrete or Masonry
go
11.0
0.0
22
Orientation: Right Side
Wall height: 8.0'
Depth below grade: 6.0'
Project Title: Lees Residence Rexburg
Report date: 02/26/08
Data filename: C:\Program files\Check\REScheck\Lees Residence
Rexburg.rck
Page 1 of 2
Insulation depth: 8.0'
Basement Wall 3: Solid Concrete or Masonry§Q41^ 11.0 0.0 26
Orientation: Back
Wall height: 8.0'
Depth below grade: 6.0'
Insulation depth: 8.0'
Basement Wall 4: Solid Concrete or Masonry 11.0 0.0 22
Orientation: Left Side
Wall height: 8.0'
Depth below grade: 6.0'
Insulation depth: 8.0'
Ceiling 1: Flat Ceiling or Scissor Truss 1329 44.0 0.0 36
Air Conditioner 1: Electric Central Air13 SEER
Furnace 1: Forced Hot Ah -93 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in
REScheck Version 4.1.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Notes:
Job Number:
Project Title: Lees Residence Rexburg Report date: 02/26/08
Data filename: C:\Program files\Check\REScheck\Lees Residence Rexburg.rck Page 2 of 2
KEner2006 IECC E
gy
yv Efficiency Certificate
Calling I Roof
44.00
Wall
21.00
Floor I Foundation
11.00
Ductwork (unconditioned spaces:
D..
Window
0.35 0.29
Door
0.35 0.66
Electric Central Air Conditioner 13 SEER
Forced Hot Air Furnace 93AFUE
Water Heater:
Name: Date:
Comments: