Loading...
HomeMy WebLinkAboutSOLAR PANELS ROOF MOUNT - 20-00801 - 129 Madison Ave - Solar PanelsFLUSH MOUNT INSTALLATION MANUAL - 2© 2019 IRONRIDGE, INC. VERSION 2.3 RATINGS Product markings are located on the Grounding Lug bolt head. MARKINGS UL 2703 LISTeD • Conforms to STD UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels.• Certified to CSA STD LTR AE-001-2012 Photovoltaic Module Racking Systems.• Max Overcurrent Protective Device (OCPD) Rating: 25A• Max Module Size: 24ft²• Max Frameless Module Size for Canadian LTR-AE: 19.5 ft²• Module Orientation: Portrait or Landscape• CAMO Specific Allowable Design Load Rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral• LTR AE Canadian Load Rating: 2400 PA• System Level Allowable Design Load Rating: meets minimum requirements of the standard (10 PSF downward, 5 PSF upward, 5 PSF lateral). Actual system structural capacity is defined by PE stamped certification letters. CLASS A SYSTeM FIRe RATING PeR UL 2703 • Any Roof Slope with Module Types 1, 2, and 3• Any module-to-roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third-party attachment.• Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating. WATeR SeAL RATINGS: UL 441 & TAS 100(A)-95 (FLASHFOOT2, ALL TILe HOOK, KNOCKOUT TILe) • Tested and evaluated without sealant.• Any roofing manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12 STRUCTURAL CeRTIFICATION • Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 FLORIDA PRODUCT APPROVAL #FL29843 • Conforms to TAS202, TAS100(A)• Approved for installation both inside and outside High Velocity Hurricane Zones (HVHZ)• Allowable design pressure up to +100/-100 PSF• Additional details on Approval can be found Here. #5003807 FLUSH MOUNT INSTALLATION MANUAL - 3© 2019 IRONRIDGE, INC. VERSION 2.3 CHeCKLIST PRe-INSTALLATION ☐Verify module compatibility. See Page 10 for info. TOOLS ReQUIReD ☐Cordless Drill (non-impact) ☐Impact Driver (for lag bolts) ☐Torque Wrench (0-250 in-lbs) ☐5/16” Socket ☐7/16” Socket ☐1/2" Socket ☐String Line TORQUe VALUeS ☐FlashFoot2 Lag Bolts (7/16" Socket): Fully Seat ☐Bonded Splice Screws (5/16" Socket): 20 in-lbs ☐Grounding Lug Nuts (7/16" Socket): 80 in-lbs ☐Grounding Lug Terminal Screws (7/16" Socket): 20 in-lbs ☐Universal Fastening Object (7/16" Socket): 80 in-lbs ☐Expansion Joint Nuts (7/16" Socket): 80 in-lbs ☐Flush Standoffs (1/2" Socket): 132 in-lbs ☐Microinverter Kit Nuts (7/16" Socket): 80 in-lbs ☐Frameless Module Kit Nuts (7/16" Socket): 80 in-lbs ☐3/8" Bonding Hardware Nuts (7/16" Socket): 250 in-lbs ☐ All Tile Hook Lags (7/16" Socket): Fully Seat ☐All Tile Hook Carriage Bolts (7/16" Socket): 132 in-lbs ☐Knockout Tile Lags (1/2" Socket): Fully Seat ☐Knockout Tile Nuts (1/2" Socket): 132 in-lbs ☐Flat Roof Attachment Nuts (9/16” Socket): 250 in-lbs Þ If using FlashVue or previous version of: FlashFoot, Integrated Grounding Mid Clamps, Grounding Lug, End Clamps, and Expansion Joints please refer to Alternate Components Addendum (Version 1.3). IRONRIDGe COMPONeNTS Bonded SpliceXR Rail L-Foot FlashFoot2 UFO and Stopper Sleeve CAMO Grounding Lug8" Bonding Jumper Expansion Joint Wire ClipEnd Cap Flush Standoff 3/8" BondingHardwareMicroinverter Kit Frameless Module Kit A A B B C C D D E E F F 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 Frameless End/Mid Clamp All Tile Hook FlashingA A B B C C D D E E F F 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 Knockout TileA A B B C C D D E E F F 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 Membrane Flashing All Tile Hook Flat Roof Attachment