HomeMy WebLinkAboutREVIEW ACTION - 08-00087 - Upper Valley Industries - CANCELLEDaR p¢xapR� a C I TY OF P.O Box 280
0 RE)MT V7RG 19 E. Main St.
l\_17... Rexburg, Idaho 83440
An,,w sF'.,0Y 0.,,,. iq' Phone (208) 359-3020
Review Action Fax (208) 359-3022
March 13, 2008
Permit Number: 08 00087 7/f
Project Name: Upper Valley Industries -Admin. & Classroom Bldg.
Project Type: Commercial New
Review Item Actions RAp roved
Administrative Review
Permit Tech Notes
Parcel #'s RPRRXBP2040100
General contractor information & registration
number needed.
Plumbing contractor signature & estimate
needed.
Mechanical contractor signature & estimate
needed.
Electrical contractor signature & estimate
needed.
What size of water meter is going to be
installed?
of x�xetR c I T Y or P.O Box 280
t.
n7�r�v�rT�..T_._Ti�—/� 19g, Main 8
l�L',L�IJ V l\l] Rexburg, Idaho 83440
anierrn t +qc� ,�u,;q, Phone (208) 359-3020
Review Action Fax (208) 359-3022
March 13, 2008
Permit Number: 08 00087
Project Name: Upper Valley Industries -Admin. & Classroom Bldg.
Project Type: Commercial New
Review Item
Building Department Review
Electrical Service Review
Electrical Energy Lighting Compliance Review
Accessibility Review
Height and Area Review
Exiting Review
Building Type Compliance
Energy Conservation Compliance Review
Mechanical Review
Structural Review
Building Code Fire Compliance Review
Electrical Circuits Review
Water and Sewer Service
Plumbing Sewer Drain Review
Waste Water Grease Trap Form
Waste Water Application
Plumbing Storm Drain Review
Plumbing Potable Water Review
AlonsRequired for Approval_ --Approved
Meets code requirements.
Meets code requirements.
Meets code requirements.
Building is Type VB.
Envelope Compliance Sheet provided.
Mechanical plans have been reviewed.
Engineering is provided. Special inspections
are required for the foundation of this building.
Provide copy of inspections when applicable.
Rear exterior walls closer than 10' to property
line must be one hour rated.
Need to have all 125V 15A and 20A receptacles
in the kitchen area GFCI protected. Need to
verify this.
All plumbing services are required to be tested
and inspected before covering.
All drain lines are required to be tested and
inspected before covering. Drainage is required
to be installed according to the Uniform
Plumbing Code 2003 edition.
All storm drains are to be tested and inspected
before covering.
All water lines are required to be tested and
inspected before covering.
02/25/2008
02/25/2008
03/12/2008
03/12/2008
03/12/2008
03/12/2008
03/12/2008
03/12/2008
03/12/2008
03/12/2008
03/13/2008
CITY OF
REXBURG
cw—
Amenwi Pomily Commonly
March 13. 2008
Permit Number: 08 00087
Review Action
Project Name: Upper Valley Industries -Admin. & Classroom Bldg.
Project Type: Commercial New
Review Item Actions Required for Approval
Fire Department Review
Required Fire Flow See site plan review.
Water Supply
Fire Access Roads
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Commercial Cooking
Alarm Systems
Other Comments
Parcel #'s RPRRXBP2040100
See site plan review.
See site plan review.
Fire extinguishers are required for this
occupancy. Minimum of 2A1013C extinguishers
are required. Install according to the
International Fire Code 2006 edition.
Extinguishers are to be installed prior to final fire
inspection.
Submit plans to the State Fire Marshall for
approval. Plans are required to be approved
before installing the automatic fire sprinkler
system.
N/A
Submit fire alarm plans to the City of Rexburg
for approval. Plans are required to be approved
prior to installation of the fire alarm system.
A lock box is required for this occupancy.
Forms are available at the Rexburg Fire
Department.
P.0 Box 280
19 E Main St.
Rexburg. Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
Approved
I I Y O F
REXBURG
An s hz, 11 Cain uoiaj
March 13, 2008
Review Action
RO Box 280
19 E. Main St.
Rexburg, daho 83440
Phone (208) 359-3020
Fax (208) 359-3022
Permit Number: 08 00087
Project Name: Upper Valley Industries -Admin. & Classroom Bldg.
Project Type: Commercial New
Review Item Actions Required for Approval Approved
Planning Staff Review
Development Standards Review Design Standards- East side of building needs
6 -feet more of wall projections in order to meet
the 20% requirement for that wall.
Development Standards Review Design Standards- Roof lines along the east
and west sides needs to varied with a change
in height every 100 feet. Proposed roof line is
119 -feet in length.
Development Standards Review Sidewalks located where vehicle overhang will
must be 6 -feet in width.
Parcel Ws RPRRXBP2040100