HomeMy WebLinkAboutSITE PLAN REVIEW NOTES - 04-00060 - AFL Telecommunications - 117 N 2nd E - CUP for 80' MonopoleNewell Goldberry Sunberg and Associates 111. E. 16Th Idaho Falls, ID 83404 Dear Newell, cily 012exlur7 STATE OF IDAHO www.ci.rexburgJd.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax(208)359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the Upper Valley Options drawings and have identified the following discrepancies: 1. I don't agree with the occupancy classification of business (B) and educational (E). Section 308.5 of the 2000 International Building Code (IBC) reads as follows: "This group (I-4) shall include buildings and structures occupied by persons on any age who receive custodial care for less than 24 hours by individuals other than parents or guardians ..." The occupancy classification should be institutional (I-4). 2. An automatic sprinkler must be installed per Section 903.2.5 of the IBC. 3. Table 1004.2.1 of the 2000 IBC identifies a maximum of 10 occupants in rooms having only one exit. The adult daycare room, the adult counseling suite, the children's group room, and both of the dining areas require an additional exit. 4. The location of the building with respect to the back property line requires that a one hour wall be constructed. Please provide details. 5. Please provide structural calculations. 6. Provide energy calculations as per the 2000 International Energy Conservation Code (IECC). 7. The Fire Department has reviewed the plans. I have attached a copy of their report. Please provide the necessary information they have requested. Please return two sets of revised plans. Let me know if I can be of any further assistance. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen Building Official cc John Millar Chris Huskinson sh ♦,..L lr �i w,H',I'_im�a 0 n�a,n:r.. .�ooq�rn�PmR.,rnll N.rd�l •. �.. nin.a uvl.. ,alai u, II• nk,,. .f. ... .�Mnl M.ir,Mn,x�lY t STATE OF IDAHO P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone(208)359-3020 Fax (208) 359-3022 e-mail rexburg@srv.net REXB URG-MADISON COUNTY EMERGENCYSER VICES 26 NORTH CENTER STREET REXBURG, IDAHO 83440 208-359-3010 208-359-3006 FAX 2000 International Fire Code Plan Date: 1-13-04 Plan Review Review Date: 1-20-04 Building Name: UPPER VALLEY OPTIONS Building Address: STOCK AND BOND AVENUE Stories: ONE Type of Construction: V -B Occupancy Classification: I-4 Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 7000 SQUARE FEET 1. Required Fire Flow (Appendix B): 2000 GPM/TWO HOURS Comments: NONE 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: PROFIT STREET Fire Hydrant Flows: PASS Fire Flow Test Location: PROFIT STREET Fire Flow Supplied By: FD Other Approved Water Source: NONE .. r m., .n �. �i .d�,,., .. ra.:� a r. amr.;d r,,. u.. ..,u i.-rm� ,. ,d ... ,. i� rcJli u� � .. ... r r+i. � Water Supply Acceptable: NO Fire Hydrant Location Acceptable: EXISTING OKAY Water Supply Comments: PROJECT REQUIRES ADDITIONAL HYDRANT CAPABLE OF PROVIDING SUFFICIENT FLOWS. LOCATE NEAR ENTRANCE TO BUILDING. 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: X Length: X Surface: X Complete Road Acceptable: YES Comments: NONE 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: NOT SHOWN Type provided acceptable: NOT SHOWN Comments: INSTALL MINIMUM 2A10BC FIRE EXTINGUISHERS WITHIN TRAVEL DISTANCES. 6. Automatic fire extinguishing systems (Section 903) Required: YES Type of system being installed: NOT SHOWN Sprinkler system monitoring (Section 907) required: YES Comments: PLEASE SUBMIT PLANS FOR FIRE SUPPRESSION SYSTEM AND FIRE ALARM SYSTEM 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: NO Type being provided: .enx.�rd .M3a Y�dn +xmNnrlAQ:ry en+il Krdnxt. �r es.EnvlfN Ju�.m NXNlnrd l'MWM1wiTllt'Mfi rvmL w.o�w})F5 �♦ �.+mm�'Flilr,µl�gryrr�rmllrsJlnMx �+. tx rlrrTM„eNif rai An✓porn �!IN1P xvmN �n Ffin�!ti•,W yi'rXrcry MM xpwn'Wrrm iNgNr�„+w Yh Automatic fuel shut-off required: Portable fire extinguisher shown: Comments: 9. Fire alarm systems (Section 907) required: YES Type of system required: Manual: Type of system being provided: Manual: Automatic: Automatic: Both: X Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO, PLEASE SUBMIT PLANS THAT SHOW THE FOLLOWING: -ALARM CONTROL AND SIGNALLING EQUIPMENT, LOCATIONS, ANNUNCIATION, POWER CONNECTION, BATTERY CALCULATIONS, CONDUCTOR TYPE AND SIZES, VOLTAGE DROP CALCULATIONS, MANUFACTURERS, MODEL NUMBERS AND LISTING INFORMATION FOR EQUIPMENT, DEVICES AND MATERIALS, AND THE INTERFACE FOR SAFETY CONTROL FUNCTIONS. 10. Other corrections that are required by special occupancy or conditions: ADDRESS ALL ABOVE ITEMS Plans as submitted are acceptable: NO Plans checked by: CHRIS HUSE INSON Date: 1-20-04 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X 'u T! i♦d'4n ! 'Y. !pm ', I +iwd $, m,.,.+i4+!�Ard rA+Wq:nnMek ritrn.,?vw:u+edtrn �pN-Y,m Nw N+h ewl a!n'�4nM.M/my&ir�n,V, ax Nhrd':�!m,. ,Avh lgnNrdr xrut, r.. fh er. q!qx il!M µ1.ne; Nt n.*roar*,W!f�k n. ra., przfArvlMrdnM1,N+i!c 1/26/2004 3:29 PM al dl'.tl �J�'k1fiMM "^4'1"�`.r Mi >�IN �'. ML"Mliulgf4 Y; Rlkl 4" k-ra('y I i+�A 4 .71 �i lu 11. o P.O. Box 280 Q ly �� �/' LL, a� �QQ %�0 4 12 North Center Street Rexburg, Idaho 83440 PHONE (208) 359-3020 STATE OF IDAHO FAx (208) 359-3022 E -MNL cityhaII@c1.rexburg.id.us Birkinbine Project Schiess & Associates (Kurt Rowland) 135 East Main Street Rexburg, Idaho 83440 Re: Birkinbine Project Dear Kurt: The site plan is under review with the following City Departmental comments. I have attempted to summarize them in this letter for you. (#) Departmental Comments 1 Planning and Zoning requested a competed site plan checklist including owner information. 2 Building Department provided the following comments: a) Is the storm water going to the storm drain system in the street? b) The trash facility isnot indicated on the plan. 3 Engineering Department needs an "as built' drawing when the plan is completed. 4 Fire Department requirements attached. 5 Streets, Water, and Waste Water Department reviews are approved by John Millar. Yours truly, CITY OF REXBURG �9at �0. Kp� Blair D. Kay City Clerk p Q (L y - a y c STATE OF IDAHO 4e(ISHEO MEMO: TO: TO WHOM IT MAY CONCERN FROM: CHRIS HUSKINSON, FIRE INSPECTOR DATE: JANUARY 14, 2004 RE: BH2HINBINE PROJECT TO WHOM IT MAY CONCERN: P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359.3020 Fax (208) 359-3022 e-mail rexburg®srv.net Upon review of the site plan drawings submitted the following items need to be addressed: 1. WATER SUPPLY: This proposed project will require a minimum of two fire hydrants capable of supplying a minimum of 2,000 GPM for two hours within 450 feet of the building. The drawings only show one existing fire hydrant. Additional plans are required to complete an accurate plan review of this project. If there ar�tions please feel free to contact me. Chris Huskinson Fire Inspector