HomeMy WebLinkAboutTRUSS SPECS - 20-00777 - 2348 Summerfield Ln - New SFRJob
20-091793T
Truss
A1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:40 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-PUZ_7lRJevz7Fm_DOw038m?07KTlq7FDVrvvXiyYnFf
Scale = 1:71.3
T2 T2
B1
W1
W2
W3
W4
W2
W3
W4
T1 T1
B1B2
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3ST2
ST1
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3 ST2
ST1
B2AB
C
D
E
F
G
H
I
J K
N M LBEBFBGBH
5x6
5x6
5x8
2x4
5x8
3x4
5x8
4x5
3x4
5x6
5x6
5x6
10-0-0
10-0-0
20-0-0
10-0-0
30-0-0
10-0-0
40-0-0
10-0-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
10
-
9
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [D:0-3-0,0-3-0], [H:0-3-0,0-3-0], [J:0-1-11,Edge], [L:0-2-0,0-2-0], [L:0-4-0,0-3-0], [M:0-4-0,0-3-4], [N:0-4-0,0-3-4], [N:0-1-8,0-0-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.63
0.68
0.67
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.13
(loc)
M-N
L-M
J
M
l/defl
>999
>846
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 303 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-8-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-3-3 oc bracing.
WEBS 1 Row at midpt G-M, E-M
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2043/0-3-8 (min. 0-2-3), J=2051/0-5-8 (min. 0-2-3)
Max Horz B=-224(LC 8)
Max UpliftB=-351(LC 10), J=-355(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3708/1075, C-D=-3296/994, D-E=-3067/1007, E-F=-2302/802, F-G=-2302/802,
G-H=-3046/1000, H-I=-3276/987, I-J=-3678/1065
BOT CHORD B-N=-835/3198, N-BE=-573/2584, BE-BF=-573/2584, M-BF=-573/2584, M-BG=-570/2575,
BG-BH=-570/2575, L-BH=-570/2575, J-L=-824/3162
WEBS F-M=-487/1427, G-M=-928/401, G-L=-122/590, I-L=-489/276, E-M=-938/405, E-N=-129/609,
C-N=-510/285
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=40ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=351,
J=355.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-091793T
Truss
A2
Truss Type
Common
Qty
23
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:42 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-LthkYRTZAXDrV38bWL2XDB5Ld79DI0lVy9O0cayYnFd
Scale = 1:67.1
T2 T2
B1
W1 W2
W3
W4
W2
W3
W4
T1 T1
B1B2AB
C
D
E
F
G
H
I
J K
P O N M LQRST
3x6
5x6
3x6
5x6
4x8 3x8
3x4
3x4
1.5x4
3x4
3x4
1.5x4
4x8
5x6
10-0-0
10-0-0
20-0-0
10-0-0
30-0-0
10-0-0
40-0-0
10-0-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
10
-
9
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [J:0-1-11,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.63
0.68
0.67
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.13
(loc)
N-P
L-N
J
N
l/defl
>999
>846
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 188 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-8-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-3-3 oc bracing.
WEBS 1 Row at midpt G-N, E-N
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2043/0-3-8 (min. 0-2-3), J=2051/0-5-8 (min. 0-2-3)
Max Horz B=194(LC 9)
Max UpliftB=-351(LC 10), J=-355(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3708/1075, C-D=-3296/994, D-E=-3067/1007, E-F=-2302/802, F-G=-2302/802,
G-H=-3046/1000, H-I=-3276/987, I-J=-3678/1065
BOT CHORD B-P=-835/3198, P-Q=-573/2584, O-Q=-573/2584, O-R=-573/2584, N-R=-573/2584,
N-S=-570/2575, M-S=-570/2575, M-T=-570/2575, L-T=-570/2575, J-L=-824/3162
WEBS F-N=-487/1427, G-N=-928/401, G-L=-122/577, I-L=-489/276, E-N=-938/405, E-P=-129/596,
C-P=-510/285
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=351,
J=355.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-091793T
Truss
A3
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:43 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-p3F6mnTBxqLi6Djo32ammOdWnXXW1VnfBp8a81yYnFc
Scale = 1:70.1
T2 T2
B1
W1
W2
W3
W4 W5
W2W3
W4W5
ST8
ST9
ST6
ST7
ST4
ST5
ST3ST2
ST1
ST8
ST9
ST6
ST7
ST4
ST5
ST3
T1 T1
B1B2AB
C
D
E
F
G
H I
O N L K JAPAQARMAS
5x8
5x6
5x8
3x6
5x8 4x8
3x4
5x6
3x6
3x6
Special
Special Special
6-8-0
6-8-0
13-1-4
6-5-4
13-4-0
0-2-12
18-6-0
5-2-0
20-0-0
1-6-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
10
-
9
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [C:0-4-0,0-3-4], [G:0-4-0,0-3-0], [H:0-2-12,0-1-8], [K:0-3-0,0-3-0], [N:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.61
0.55
0.56
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.10
-0.16
0.03
0.05
(loc)
K-L
K-L
H
M-N
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 283 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W3,W5: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-4-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt E-L, F-L, D-N
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 0-5-8 except (jt=length) H=0-3-8, M=0-3-8.
(lb) - Max Horz B=-194(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) except B=-108(LC 8), N=-411(LC 8), H=-208(LC 8), M=-227(LC 8)
Max Grav All reactions 250 lb or less at joint(s) except B=580(LC 17), N=2373(LC 1), H=1161(LC 1), M=695(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-546/306, C-D=-31/750, D-E=-422/153, E-F=-401/153, F-G=-1106/213, G-H=-1827/266
BOT CHORD B-O=-248/381, N-O=-250/378, N-AP=-568/202, AP-AQ=-568/202, AQ-AR=-568/202,
M-AR=-568/202, L-M=-568/202, L-AS=0/874, K-AS=0/874, J-K=-149/1516, H-J=-148/1519
WEBS E-L=-332/51, F-L=-988/234, F-K=-26/480, G-K=-733/175, D-L=-44/1105, D-N=-1693/268,
C-N=-747/167
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint B, 411 lb uplift at joint N,
208 lb uplift at joint H and 227 lb uplift at joint M.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 190 lb down and 88 lb up at
13-11-4, and 190 lb down and 88 lb up at 15-11-4, and 190 lb down and 88 lb up at 17-11-4 on bottom chord. The design/selection of
such connection device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Continued on page 2
Job
20-091793T
Truss
A3
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:44 2020 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-HFpUz7Upi8UZkNI_dm5?IbAhXxslmy1oPTt7gTyYnFb
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-E=-84, E-I=-84, B-H=-14
Concentrated Loads (lb)
Vert: AP=-190(B) AQ=-190(B) AR=-190(B)
Job
20-091793T
Truss
B1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:45 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-lSNsBTVSTScQMXtABTcErpjv6LEZVPJye7dgDvyYnFa
Scale = 1:39.0
T1 T2
B1
W1
W2 W3W2W3
ST4ST2
ST3ST1
ST4 ST2
ST3 ST1
B1A
B
C
D
E
F
I H GXYZAAABACADAE AF AG
5x6
3x6 3x6 5x8
3x4 3x4
Special Special Special Special
Special
Special Special Special Special Special
4-9-0
4-9-0
10-9-0
6-0-0
16-9-0
6-0-0
21-6-0
4-9-0
-1-0-0
1-0-0
4-9-0
4-9-0
10-9-0
6-0-0
16-9-0
6-0-0
21-6-0
4-9-0
0-
4
-
3
5-
8
-
1
1
6-
2
-
7
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [H:0-4-0,0-3-0], [L:0-1-12,0-0-12], [U:0-1-12,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.42
0.38
0.56
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.10
-0.14
0.05
0.05
(loc)
H-I
H-I
F
H-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 113 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-4-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)F=1143/0-3-8 (min. 0-1-8), B=1244/0-3-8 (min. 0-1-8)
Max Horz B=108(LC 7)
Max UpliftF=-249(LC 8), B=-296(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2110/456, C-D=-1419/343, D-E=-1420/343, E-F=-2130/467
BOT CHORD B-X=-361/1804, X-Y=-361/1804, I-Y=-361/1804, I-Z=-361/1804, Z-AA=-361/1804,
AA-AB=-361/1804, H-AB=-361/1804, H-AC=-374/1825, AC-AD=-374/1825, AD-AE=-374/1825,
G-AE=-374/1825, G-AF=-374/1825, AF-AG=-374/1825, F-AG=-374/1825
WEBS D-H=-163/686, E-H=-748/221, C-H=-725/208
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 249 lb uplift at joint F and 296 lb uplift at joint
B.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 21 lb down and 18 lb up at 2-0-12,
21 lb down and 18 lb up at 4-0-12, 21 lb down and 18 lb up at 6-0-12, 21 lb down and 18 lb up at 8-0-12, 21 lb down and 18 lb up at
10-0-12, 21 lb down and 18 lb up at 12-0-12, 21 lb down and 18 lb up at 14-0-12, 21 lb down and 18 lb up at 16-0-12, and 21 lb down
and 18 lb up at 18-0-12, and 21 lb down and 18 lb up at 20-0-12 on bottom chord. The design/selection of such connection device(s)
is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Continued on page 2
Job
20-091793T
Truss
B1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:46 2020 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-EexFOpW4ElkHzhSNlB7TO0F4slaoEsY5tmMElLyYnFZ
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-F=-84, B-F=-14
Concentrated Loads (lb)
Vert: X=-21(F) Y=-21(F) Z=-21(F) AA=-21(F) AB=-21(F) AC=-21(F) AD=-21(F) AE=-21(F) AF=-21(F) AG=-21(F)
Job
20-091793T
Truss
B2
Truss Type
Common
Qty
2
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:46 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-EexFOpW4ElkHzhSNlB7TO0F55lbJExE5tmMElLyYnFZ
Scale = 1:36.2
T1 T2
B1
W1
W2
W1
W2
B2A
B
C
D
E
F
H G
I
J K
L
4x5
3x6 3x6 5x6
1.5x4
3x4
1.5x4
7-2-0
7-2-0
14-4-0
7-2-0
21-6-0
7-2-0
-1-0-0
1-0-0
5-4-8
5-4-8
10-9-0
5-4-8
16-1-8
5-4-8
21-6-0
5-4-8
0-
4
-
3
5-
8
-
1
1
6-
2
-
7
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [G:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.34
0.35
0.26
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.13
0.04
0.04
(loc)
F-G
F-G
F
F-G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 89 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-7-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)F=1036/0-3-8 (min. 0-1-8), B=1144/0-3-8 (min. 0-1-8)
Max Horz B=108(LC 11)
Max UpliftF=-160(LC 12), B=-212(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-I=-1853/340, C-I=-1766/353, C-J=-1595/338, D-J=-1483/350, D-K=-1494/369,
E-K=-1606/351, E-L=-1685/372, F-L=-1865/361
BOT CHORD B-H=-264/1566, G-H=-111/1028, F-G=-266/1580
WEBS D-G=-104/579, E-G=-446/176, D-H=-98/563, C-H=-438/174
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 10-9-0, Exterior(2) 10-9-0 to 13-9-0,
Interior(1) 13-9-0 to 21-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 160 lb uplift at joint F and 212 lb uplift at joint
B.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-091793T
Truss
C1
Truss Type
Common
Qty
1
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:48 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-A12?pUXKmN_?D_blsb9xTRLVwYMuiu0OK4rLpEyYnFX
Scale = 1:24.8
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
A
B
C
D
E
F
G
H
I
N M L K J
4x5
3x4 3x4
13-4-0
13-4-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
14-4-0
1-0-0
0-
4
-
3
3-
8
-
3
4-
1
-
1
5
0-
4
-
3
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.02
0.05
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
I
I
H
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 55 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-4-0.
(lb) - Max Horz B=-71(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) B, H, M, N, K, J
Max Grav All reactions 250 lb or less at joint(s) B, H, L, M, N, K, J
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-091793T
Truss
C2
Truss Type
Common
Qty
3
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:49 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-eDcN0qYyWg6rq8AyQJhA?ftZNycIRKJXZkbuMgyYnFW
Scale = 1:23.3
T1
T2
B1
W1
A
B
C
D
E
5x6
3x6 3x6 1.5x4
6-8-0
6-8-0
13-4-0
6-8-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
0-
4
-
3
3-
8
-
3
4-
1
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-2-9,0-1-8], [D:0-2-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.53
0.40
0.11
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.12
0.01
0.04
(loc)
D-E
D-E
D
D-E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 44 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-8-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)D=625/0-5-8 (min. 0-1-8), B=745/0-5-8 (min. 0-1-8)
Max Horz B=70(LC 9)
Max UpliftD=-95(LC 10), B=-153(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-906/271, C-D=-903/269
BOT CHORD B-E=-143/690, D-E=-143/690
WEBS C-E=0/261
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=153.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-091793T
Truss
J1
Truss Type
Jack-Open
Qty
3
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:49 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-eDcN0qYyWg6rq8AyQJhA?ftYzyfeRKqXZkbuMgyYnFW
Scale = 1:20.7
T1
B1
W1
A
B
C
D
E
1.5x4
2x4 1.5x4
6-4-8
6-4-8
-1-0-0
1-0-0
6-4-8
6-4-8
0-
4
-
3
3-
6
-
7
4-
0
-
3
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.62
0.25
0.07
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.07
-0.12
0.00
0.00
(loc)
B-D
B-D
B
l/defl
>999
>597
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 24 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=410/0-3-8 (min. 0-1-8), D=288/Mechanical
Max Horz B=125(LC 12)
Max UpliftB=-75(LC 12), D=-67(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 6-2-12 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip
DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-091793T
Truss
J2
Truss Type
Jack-Open
Qty
10
Ply
1
KARTCHNER HOMES SF3B16 ATHENS B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Tue Sep 29 10:53:50 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-6PAlEAZaH_EiSIl8_0CPYsQrWM2uAoDhoOKRu7yYnFV
Scale = 1:8.2
T1
B1
A
B
C
D
3x4
1-6-0
1-6-0
-1-0-0
1-0-0
1-6-0
1-6-0
0-
4
-
3
1-
1
-
3
1-
6
-
1
5
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.13
0.05
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
B
B-D
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 6 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 1-6-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=198/0-3-8 (min. 0-1-8), D=38/Mechanical
Max Horz B=91(LC 10)
Max UpliftB=-124(LC 10), D=-24(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=124.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard