HomeMy WebLinkAboutCOMPLIANCE CERTIFICATION - 08-00049 - 277 Pollard Ave - New SFR[I�iwww;111 277 Pollard -Rockwell r8/11' REScheck Software Version 3.7.3 Compliance Certificate Project Title: H-1200 Std. Plan Report Date: 11/16/06 Data filename: D:\z - ResChecks\H-1200 Std Plan 11-16-06.rck Energy Code: 2003 IECC Location: Ammon, Idaho Construction Type: Single Family Glazing Area Percentage: 14% Heating Degree Days: 7918 Construction Site: Owner/Agent: Designer/Contractor: Rockwell Development Inc. Compliance: Passes Maximum UA: 309 Your Home UA: 242 --> 21.7% Better Than Code (UA) Ceiling 1: Flat Ceiling or Scissor Truss: 1205 50.0 0.0 31 Wall 1: Wood Frame, 24" o .c.: 1332 22.0 0.0 62 Window 1: Vinyl Frame:Double Pane with Low -E: 104 0.320 33 Door 1: Solid: 40 0.160 6 Door 2: Glass: 33 0.340 11 Basement Wall 1: Solid Concrete or Masonry: 1136 11.0 0.0 66 Window 2: Vinyl Frame:Double Pane: 64 0.490 31 Furnace 1: Forced Hot Air: 93 AFUE Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Company Name Date Project Notes: Compiled:l 1/7/06 H-1200 Std. Plan Pagel of 4 Date: 11/16/06 REScheck Software Version 3.7.3 Inspection Checklist Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-50.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 24" o .c., R-22.0 cavity Insulation Comments: Basement Walls: ❑ Basement Wall 1: Solid Concrete or Masonry, 8.0' ht17.0' bg/8.0' insul, R-11.0 cavity insulation Comments: Windows: ❑ Window is Vinyl Frame:Double Pane with Low -E, U -factor: 0.320 For windows without labeled U -factors, describe features: #Panes _ Frame Type Thermal Break? — Yes — No Comments: ❑ Window 2: Vinyl Frame:Double Pane, U -factor: 0.490 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? —Yes — No Comments: Doors: ❑ Door 1: Solid, U -factor: 0.160 Comments: ❑ Door 2: Glass, U -factor: 0.340 Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 93 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) Installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from Insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 Inches is R-19. Vapor Retarder: ❑ Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation Instructions. ❑ Materials and equipment must be identified so that compliance can be determined. H-1200 Std. Plan Page 2 of 4 ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R -values, glazing U -factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be Insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be Insulated to R-6. ❑ Supply ducts in unconditioned Spaces must be insulated to R-11. ❑ Return ducts In unconditioned spaces (except basements) must be Insulated to R-2, ❑ Where exterior walls are used as plenums, the wall must be insulated to R-11. ❑ Insulation is not required on return ducts In basements. Duct Construction: ❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. H-1200 Std. Plan Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp, Insulation Thickness in Inches by Pipe Sizes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water 1.25' to 2.0" 2.5' to 4" Heating Systems Temperature (°F) Up to V Up to 1.25' 1.5' to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 i 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes NOTES TO FIELD: (Building Department Use Only) H-1200 Std. Plan Page 4 of 4 Fluid Temp, Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2" Runouts V and Less 1.25' to 2.0" 2.5' to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) H-1200 Std. Plan Page 4 of 4