Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLAN - 08-00049 - 277 Pollard Ave - New SFR
A3 EI Rm1 n A complete TT.-Xpert framing plan mwuires the Trus Joist Framer's Pocket B 's See Trus Joist Framer's Pocket Cuide for Product Trademark Information E1I/I JOIST AND BEAM LIST Plot ID SUlLD1NG Product MA`TERIAI$ A3 EI Rm1 n A complete TT.-Xpert framing plan mwuires the Trus Joist Framer's Pocket B 's See Trus Joist Framer's Pocket Cuide for Product Trademark Information E1I/I JOIST AND BEAM LIST Plot ID Length Product Plies Qty A33 33' 117/8" TJI 110 joist 1 5 A32 32' 117/811 TJI 110.1oist 1 _ A3 _. _ _ 1 1 A30 30' 11 7/8" TJI 110.loist 1 1 2m1 16' 117/8" TJI 110,loist I A13 A14 14' 11718" TTI 110•1oist 1 5 A13 13' 117/8" Tn 110.1oist 1 1 Al2 12' 117/8" TJI 110 joist l Rml Al2 B35 35' 117/811 TJI 2i0joist 1 I B34 34' Rm! 1 9 I 33' i i 1 Rml ACCESSORIES LIST Rml 30 A31 a' 11/4" x 11 7/8" 1.3E TimberStrand LSL 1 633 A3 ----- _ - - _-_ _ _ - - - - _ - A3 - - A 32- A33 -- 1 B33 B35 _ 117/8" TJI 210 Blocking Panels 1 10 634 4" 117/8" TJI 210 Blocking Panels 116" __'{• �. . i i i I' ! i i i SKI 4' x 8' 23/32" Structurwood Edge Gold (24" Span Rating) 1 Rm! Bk" Random length blocking panel cuts Bk, Blocking Panels; km, Rim Board I Rml A16 ..Rml A14 i _.;22 I Rml A Eat ` 777.17-1 —Rm1 _. El �.- EI A3 O - �-__ � > I-�-------- A3 - --� - -- I - - - —Rm1 -- - - 3 I) 0800049 277 Pollard—Rockwell JOB COMMENTS CREATED BY 65 -Rockwell Development BMC West 14-12001425 N. Holmes Ave. j SYSTEM WARNINGSIdaho Falls, ID 83403 (205)523-8591 - - 5[/ Do not splice Parallel Closure less tF FAX: 208-522-2106 �-� three times the cantilever length fnm face of cantilever's support. O SYMBOL LEGEND Point Load Line Load Area Load Detail Callout Label (See Framer's Pocket Guide) LEVEL NOTES File Name: 66 -Rockwell Development John d Julie Larsen.70B Level Name: Main Level Plotted: 5/24/2004 16:59 Design Status: Main Leve 1...5/24/200416:53 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 12 psf Dead Load Maximum Joist Deflection: L/360 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 48 Lowest Rating: 38 Highest Rating: 60 Glued 4 Nailed Decking is Required Direct Applied Ceiling of 1/2" Gypsum is Required Floor Decking: 23/32" Structurwood Edge Gold (24" Span Rating) Normal O.C. Spacing = 16" Standard Blocking: Bkl" "Unless noted otherwise Layout Scale: 3/16" = V 1 of 1 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE TJ•%pert 6.35 (8689) 06.35 06.35 36.35 P6.35 JOIST AND BEAM LIST Plot ID Length Product Plies Qty A33 33' 117/8" TJI 110 joist 1 5 A32 32' 117/811 TJI 110.1oist 1 3 A31 31' 117/8" TJI 110,ioist 1 1 A30 30' 11 7/8" TJI 110.loist 1 1 A16 16' 117/8" TJI 110,loist I 1 A14 14' 11718" TTI 110•1oist 1 5 A13 13' 117/8" Tn 110.1oist 1 1 Al2 12' 117/8" TJI 110 joist l 5 B35 35' 117/811 TJI 2i0joist 1 I B34 34' 117/8" TTI 210,1oist 1 9 833 33' 117/8" TJI 210 joist 1 2 ACCESSORIES LIST Rml 16' 11/4" x 11 7/8" 1.3E TimberStrand LSL 1 11 Ski V 2 1/4" 11 7/8" TJI 110 Blocking Panels 1 8 Bk1" 6' 10" 11 7/8" TTI 110 Bloakinq Panels 1 1 Bk2 V 115/16" 117/8" TJI 210 Blocking Panels 1 10 Bk2" 4" 117/8" TJI 210 Blocking Panels 1 1 SKI 4' x 8' 23/32" Structurwood Edge Gold (24" Span Rating) 1 39 Bk" Random length blocking panel cuts Bk, Blocking Panels; km, Rim Board JOB COMMENTS CREATED BY 65 -Rockwell Development BMC West 14-12001425 N. Holmes Ave. j SYSTEM WARNINGSIdaho Falls, ID 83403 (205)523-8591 - - 5[/ Do not splice Parallel Closure less tF FAX: 208-522-2106 �-� three times the cantilever length fnm face of cantilever's support. O SYMBOL LEGEND Point Load Line Load Area Load Detail Callout Label (See Framer's Pocket Guide) LEVEL NOTES File Name: 66 -Rockwell Development John d Julie Larsen.70B Level Name: Main Level Plotted: 5/24/2004 16:59 Design Status: Main Leve 1...5/24/200416:53 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 12 psf Dead Load Maximum Joist Deflection: L/360 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 48 Lowest Rating: 38 Highest Rating: 60 Glued 4 Nailed Decking is Required Direct Applied Ceiling of 1/2" Gypsum is Required Floor Decking: 23/32" Structurwood Edge Gold (24" Span Rating) Normal O.C. Spacing = 16" Standard Blocking: Bkl" "Unless noted otherwise Layout Scale: 3/16" = V 1 of 1 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE TJ•%pert 6.35 (8689) 06.35 06.35 36.35 P6.35