HomeMy WebLinkAboutREVIEW ACTION - 08-00047 - Madison Women's Clinic - Basement Remodelpex BUg --CITY OF ` REXBURG , — ov -- Amend;&.dyCommw,ity Review Action April 4, 2008 Permit Number: 08 00047 Project Name: Madison Women's Clinic Basement Remodel P.O Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 Project Type: Commercial Remodel Review Item Actions Required for Approval Approved Building Department Review Electrical Circuits Review Electrical Service Review Water and Sewer Service Plumbing Sewer Drain Review Plumbing Storm Drain Review Plumbing Potable Water Review Accessibility Review Interior Environment Electrical Energy Lighting Compliance Review Exiting Review Energy Conservation Compliance Review Building Code Fire Compliance Review No electrical plan was submitted, make sure that this remodel is wired to the 2005 NEC. The service is not changing, basement remodel only. Water and sewer services are required to be sized according to the Uniform Plumbing Code 2003 edition. Services are required to sized large enough to support additional fixtures. If ejectors are used in a commercial application special requirements are to be met. N/A 02/29/2008 02/29/2008 03/03/2008 03/03/2008 03/03/2008 All new water lines are required to be installed 03/03/2008 according to the Uniform Plumbing Code 2003 edition. The ADA restroom does not scale out to have the 60" space required from the nearest wall nest to the toilet to the sink. Also the sink does not have the required space in front of it. The door that connects the two hallways does not meet accessible standards. It needs 18" clear space on the handle side. A site plan should be provided to identify the accessible route from the front. How is ceiling height being resolved? See IBC Section 1208 and Section 701.3 of the International Existing Building Code. Plans identify a 6'8" ceiling height in the halls. See IBC Section 1208 and Section 701.3 of the International Existing Building Code. Provide lighting for energy review. Provide rated door on archive room door. April 4, 2008 Permit Number: 08 00047 Project Name: Madison Women's Clinic Basement Remodel Project Type: Commercial Remodel Review Item Actions Required for Approval Approved Structural Review Parcel #'s RPRMADP0010015 Engineering provided. RO Box 280 'y -��rrwvDDTi )7n -�+ 19E Main St. J p RE" V RG Rexburg. klaho 83440 7 dr i Mni I� for iuniry 208 Phone 359-3020 ( ) Review Action Fax (208) 359-3022 April 4, 2008 Permit Number: 08 00047 Project Name: Madison Women's Clinic Basement Remodel Project Type: Commercial Remodel Review Item Actions Required for Approval Approved Structural Review Parcel #'s RPRMADP0010015 Engineering provided. eexeuq —_CITY OF ° REXBURG A w i.a FnmIII, Cammuniry April 4, 2008 ) F t Review Action I P.O Box 280 19 E Main St. Rexburg. Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 Permit Number: 08 00047 Project Name: Madison Women's Clinic Basement Remodel Project Type: Commercial Remodel Review Item Actions Required for Approval Approved Fire Department Review Required Fire Flow Established Water Supply Fire Access Roads Fire Extinguishers Automatic Fire Extinguishing Systems Standpipes Commercial Cooking Alarm Systems Other Comments Parcel #'s RPRMADP0010015 established established Must be installed before final inspection. Existing building. Not required as shown on plans provided. N/A N/A Smoke detectors are required to be installed according to NFPA and International Fire Code 2006 edition. If fire alarm panel is installed a lock box is required. 03/03/2008 03/03/2008 03/03/2008 03/03/2008 03/03/2008 03/03/2008 03/03/2008 03/03/2008 03/03/2008