LOAD SHORT FORM - 20-00723 - 121 W 9000 S - New SFR Mechanical
Load Short Form Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Information HtgClgInfiltration Outsidedb(°F)-790MethodSimplified Insidedb(°F)7075Construction qualitySemi-tight DesignTD(°F)7715Fireplaces0 Daily range-H Inside humidity (%)5050 Moisture difference (gr/lb)62-29 HEATING EQUIPMENTCOOLING EQUIPMENT MakeCarrierMakeCarrier TradeCarrier Infinity 98 Modulating...TradeCARRIER Model59MN7B080V17--14Cond24ABB336A003 AHRI ref0CoilCNPVP3617ALA++TDR AHRI ref9858468 Efficiency97.4 AFUEEfficiency10.5 EER, 13 SEER Heating input80000BtuhSensible cooling31020Btuh Heating output63180BtuhLatent cooling0Btuh Temperature rise58°FTotal cooling31020Btuh Actual air flow1170cfmActual air flow1265cfm Air flow factor0.028cfm/BtuhAir flow factor0.063cfm/Btuh Static pressure0.90in H2OStatic pressure0.90in H2O Space thermostatLoad sensible heat ratio1.00 ROOM NAMEAreaHtg loadClg loadHtg AVFClg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Main Zone219024663171646951073 (Rest of House)2505168365029475314 Entire House4695414992010911701265 Other equip loads76701460 Equip. @0.95RSM20404 Latent cooling0 TOTALS4695491682040411701265 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Load Short Form Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Information HtgClgInfiltration Outsidedb(°F)-790MethodSimplified Insidedb(°F)7075Construction qualitySemi-tight DesignTD(°F)7715Fireplaces0 Daily range-H Inside humidity (%)5050 Moisture difference (gr/lb)62-29 HEATING EQUIPMENTCOOLING EQUIPMENT Maken/aMaken/a Traden/aTraden/a Modeln/aCondn/a AHRI refn/aCoiln/a AHRI refn/a Efficiencyn/aEfficiencyn/a Heating inputSensible cooling0Btuh Heating output0BtuhLatent cooling0Btuh Temperature rise0°FTotal cooling0Btuh Actual air flow0cfmActual air flow0cfm Air flow factor0cfm/BtuhAir flow factor0cfm/Btuh Static pressure0in H2OStatic pressure0in H2O Space thermostatn/aLoad sensible heat ratio0 ROOM NAMEAreaHtg loadClg loadHtg AVFClg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Storage2710000 Bedroom 3211230511306571 B TR24163350 B Bath424082221214 Bedroom 4221227611306471 Mech1100000 Family Rm104176851736217109 Bedroom 2273399880711350 Cold Storage3140000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E (Rest of House)2505168365029475314 Other equip loads00 Equip. @0.95RSM4758 Latent cooling433 TOTALS2505168365190475314 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 3 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Load Short Form Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Information HtgClgInfiltration Outsidedb(°F)-790MethodSimplified Insidedb(°F)7075Construction qualitySemi-tight DesignTD(°F)7715Fireplaces0 Daily range-H Inside humidity (%)5050 Moisture difference (gr/lb)62-29 HEATING EQUIPMENTCOOLING EQUIPMENT Maken/aMaken/a Traden/aTraden/a Modeln/aCondn/a AHRI refn/aCoiln/a AHRI refn/a Efficiencyn/aEfficiencyn/a Heating inputSensible cooling0Btuh Heating output0BtuhLatent cooling0Btuh Temperature rise0°FTotal cooling0Btuh Actual air flow0cfmActual air flow0cfm Air flow factor0cfm/BtuhAir flow factor0cfm/Btuh Static pressure0in H2OStatic pressure0in H2O Space thermostatn/aLoad sensible heat ratio0 ROOM NAMEAreaHtg loadClg loadHtg AVFClg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Master28936732645104165 M WIC590000 Bedroom 11512258174564109 M Bath8810026232839 Bath728876422540 laundry145306015138695 Pantry810000 Office1632820182780114 Kit/Din/Great Rm1143109628168309511 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 4 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Main Zone219024663171646951073 Other equip loads00 Equip. @0.95RSM16237 Latent cooling41 TOTALS219024663162786951073 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 5 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Building Analysis Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Conditions Location:Indoor:HeatingCooling Idaho Falls Rgnl, ID, USIndoortemperature(°F)7075 Elevation:4744ftDesignTD(°F)7715 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.7-29.4 Infiltration: Drybulb(°F)-790 Dailyrange(°F)-35(H) MethodSimplified Wetbulb(°F)-61 Construction qualitySemi-tight Wind speed (mph)15.07.5 Fireplaces0 Heating ComponentBtuh/ft²Btuh% of load Walls4.31476530.0 Ventilation Glazing36.0974519.8 Doors29.930896.3 Walls Ceilings1.538437.8 Infiltration Floors1.71.742278.6 Infiltration2.5582911.9 Ducts00 Piping00 Floors Humidification00 Ventilation767015.6 GlazingCeilings Adjustments0 Doors Total49168100.0 Cooling ComponentBtuh/ft²Btuh% of load Walls Ventilation Walls0.28313.9 Glazing36.5985645.7 Doors7.37493.5 Ceilings0.821099.8 InternalGains Floors000 Infiltration0.25842.7 Glazing Ducts00 Ventilation14606.8 Internal gains598027.7 Blower00Infiltration Adjustments0 Ceilings Doors Total21569100.0 Latent Cooling Load = 0 Btuh OverallU-value=0.052Btuh/ft²-°F Data entries checked. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Building Analysis Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Conditions Location:Indoor:HeatingCooling Idaho Falls Rgnl, ID, USIndoortemperature(°F)7075 Elevation:4744ftDesignTD(°F)7715 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.7-29.4 Infiltration: Drybulb(°F)-790 Dailyrange(°F)-35(H) MethodSimplified Wetbulb(°F)-61 Construction qualitySemi-tight Wind speed (mph)15.07.5 Fireplaces0 Heating ComponentBtuh/ft²Btuh% of load Walls3.8700041.6 Infiltration Glazing36.0310018.4 Doors29.96814.0 Ceilings1.54842.9 Floors Walls Floors1.71.7422725.1 Infiltration2.513448.0 Ducts00 Piping00 Humidification00 Ceilings Ventilation00 Doors Adjustments0 Glazing Total16836100.0 Cooling ComponentBtuh/ft²Btuh% of load Other Walls0.0821.6 Glazing32.5279255.5 Doors7.31653.3 InternalGains Ceilings0.82665.3 Floors000 Infiltration0.21352.7 Ducts00 Ventilation00 Glazing Internal gains159031.6 Infiltration Blower00 Ceilings Adjustments0 Doors Total5029100.0 Latent Cooling Load = 433 Btuh OverallU-value=0.040Btuh/ft²-°F WARNING: window to floor area ratio = 3.4% - less than 5%. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Building Analysis Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Conditions Location:Indoor:HeatingCooling Idaho Falls Rgnl, ID, USIndoortemperature(°F)7075 Elevation:4744ftDesignTD(°F)7715 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.7-29.4 Infiltration: Drybulb(°F)-790 Dailyrange(°F)-35(H) MethodSimplified Wetbulb(°F)-61 Construction qualitySemi-tight Wind speed (mph)15.07.5 Fireplaces0 Heating ComponentBtuh/ft²Btuh% of load Walls5.0776631.5 Infiltration Glazing36.0664526.9 Doors29.924089.8 Walls Ceilings1.5335913.6 Floors0000 Infiltration2.5448518.2 Ceilings Ducts00 Piping00 Humidification00 Ventilation00 Doors Adjustments0 Glazing Total24663100.0 Cooling ComponentBtuh/ft²Btuh% of load Walls Walls0.57494.4 Glazing49.6914753.3 InternalGains Doors7.35843.4 Ceilings0.8184410.7 Floors000 Infiltration0.24492.6 Infiltration Ducts00 Ventilation00 Glazing Internal gains439025.6 Ceilings Blower00 Adjustments0 Doors Total17164100.0 Latent Cooling Load = 41 Btuh OverallU-value=0.066Btuh/ft²-°F Data entries checked. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 3 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Component Constructions Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Conditions Location:Indoor:HeatingCooling Idaho Falls Rgnl, ID, USIndoortemperature(°F)7075 Elevation:4744ftDesignTD(°F)7715 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.7-29.4 Infiltration: Drybulb(°F)-790 Dailyrange(°F)-35(H) MethodSimplified Wetbulb(°F)-61 Construction qualitySemi-tight Wind speed (mph)15.07.5 Fireplaces0 Construction descriptions OrAreaU-valueInsul RHtg HTMLossClg HTMGain ft²Btuh/ft²-°Fft²-°F/BtuhBtuh/ft²BtuhBtuh/ft²Btuh Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum n2950.06521.04.9914690.48142 e4890.06521.04.9924370.48235 board int fnsh, 2"x6" wood frm, 16" o.c. stud s2720.06521.04.9913550.48131 w5020.06521.04.9925050.48242 all15580.06521.04.9977660.48749 15B19-0wc-6: Bg wall, light dry soil, 2"x4" wood int frm, concrete wall, n3150.04319.03.6211390.0310 e6190.04319.03.8523830.0532 r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh s3290.04319.03.6912140.0412 w5960.04319.03.8022630.0528 all18580.04319.03.7770000.0482 Partitions (none) Windows 4A5-2ov: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" n500.470036.0180212.7637 e700.470036.0252345.93211 gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht s230.470036.082930.8709 s360.470036.0129830.81109 w910.470036.0329245.94190 all2700.470036.0974536.59856 Doors 11D0: Door, wd sc typee580.390029.917277.25419 w230.390029.96817.25165 w230.390029.96817.25165 all1030.390029.930897.25749 Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 25050.02050.01.5338430.842109 gypsum board int fnsh Floors 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh25050.02201.69422700 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Component Constructions Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Conditions Location:Indoor:HeatingCooling Idaho Falls Rgnl, ID, USIndoortemperature(°F)7075 Elevation:4744ftDesignTD(°F)7715 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.7-29.4 Infiltration: Drybulb(°F)-790 Dailyrange(°F)-35(H) MethodSimplified Wetbulb(°F)-61 Construction qualitySemi-tight Wind speed (mph)15.07.5 Fireplaces0 Construction descriptions OrAreaU-valueInsul RHtg HTMLossClg HTMGain ft²Btuh/ft²-°Fft²-°F/BtuhBtuh/ft²BtuhBtuh/ft²Btuh Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum n2950.06521.04.9914690.48142 e4890.06521.04.9924370.48235 board int fnsh, 2"x6" wood frm, 16" o.c. stud s2720.06521.04.9913550.48131 w5020.06521.04.9925050.48242 all15580.06521.04.9977660.48749 Partitions (none) Windows 4A5-2ov: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" e700.470036.0252345.93211 s230.470036.082930.8709 gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht w910.470036.0329245.94190 all1840.470036.0664544.08109 Doors 11D0: Door, wd sc typee580.390029.917277.25419 w230.390029.96817.25165 all810.390029.924087.25584 Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 21900.02050.01.5333590.841844 gypsum board int fnsh Floors (none) 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 3 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Component Constructions Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Design Conditions Location:Indoor:HeatingCooling Idaho Falls Rgnl, ID, USIndoortemperature(°F)7075 Elevation:4744ftDesignTD(°F)7715 Latitude:44°NRelative humidity (%)5050 Outdoor:HeatingCooling Moisture difference (gr/lb)61.7-29.4 Infiltration: Drybulb(°F)-790 Dailyrange(°F)-35(H) MethodSimplified Wetbulb(°F)-61 Construction qualitySemi-tight Wind speed (mph)15.07.5 Fireplaces0 Construction descriptions OrAreaU-valueInsul RHtg HTMLossClg HTMGain ft²Btuh/ft²-°Fft²-°F/BtuhBtuh/ft²BtuhBtuh/ft²Btuh Walls 15B19-0wc-6: Bg wall, light dry soil, 2"x4" wood int frm, concrete wall, n3150.04319.03.6211390.0310 e6190.04319.03.8523830.0532 r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh s3290.04319.03.6912140.0412 w5960.04319.03.8022630.0528 all18580.04319.03.7770000.0482 Partitions (none) Windows 4A5-2ov: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" n500.470036.0180212.7637 s360.470036.0129830.81109 gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht all860.470036.0310020.31746 Doors 11D0: Door, wd sc typew230.390029.96817.25165 Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 3150.02050.01.534840.84266 gypsum board int fnsh Floors 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh25050.02201.69422700 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 4 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Project Summary Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Notes:INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Design Information Weather:Idaho Falls Rgnl, ID, US Winter Design ConditionsSummer Design Conditions Outside db-7°FOutside db90°F Inside db70°FInside db75°F Design TD77°FDesign TD15°F Daily rangeH Relative humidity50% Moisture difference-29gr/lb Heating SummarySensible Cooling Equipment Load Sizing Structure41499BtuhStructure20109Btuh Ducts0BtuhDucts0Btuh Central vent (108 cfm)7670BtuhCentral vent (108 cfm)1460Btuh Outside airOutside air Humidification0BtuhBlower0Btuh Piping0Btuh Equipment load49168BtuhUse manufacturer's datan Rate/swing multiplier0.95 Infiltration Equipment sensible load20404Btuh Latent Cooling Equipment Load Sizing MethodSimplified Construction qualitySemi-tight Fireplaces0Structure474Btuh Ducts0Btuh Central vent (108 cfm)-1815Btuh HeatingCooling Outside air Area(ft²)46954695Equipment latent load0Btuh Volume(ft³)2597225972 Equipment Total Load (Sen+Lat) Air changes/hour0.190.1020404Btuh Equiv. AVF (cfm)8243Req. total capacity at 1.00 SHR1.7ton Heating Equipment SummaryCooling Equipment Summary MakeCarrierMakeCarrier TradeCarrier Infinity 98 Modulating...TradeCARRIER Model59MN7B080V17--14Cond24ABB336A003 AHRI ref0CoilCNPVP3617ALA++TDR AHRI ref9858468 Efficiency97.4 AFUEEfficiency10.5 EER, 13 SEER Heating input80000BtuhSensible cooling31020Btuh Heating output63180BtuhLatent cooling0Btuh Temperature rise58°FTotal cooling31020Btuh Actual air flow1170cfmActual air flow1265cfm Air flow factor0.028cfm/BtuhAir flow factor0.063cfm/Btuh Static pressure0.90in H2OStatic pressure0.90in H2O Space thermostatLoad sensible heat ratio1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Project Summary Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Notes:INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Design Information Weather:Idaho Falls Rgnl, ID, US Winter Design ConditionsSummer Design Conditions Outside db-7°FOutside db90°F Inside db70°FInside db75°F Design TD77°FDesign TD15°F Daily rangeH Relative humidity50% Moisture difference-29gr/lb Heating SummarySensible Cooling Equipment Load Sizing Structure16836BtuhStructure5029Btuh Ducts0BtuhDucts0Btuh Central vent (58 cfm)0BtuhCentral vent (58 cfm)0Btuh Humidification0BtuhBlower0Btuh Piping0Btuh Equipment load16836BtuhUse manufacturer's datan Rate/swing multiplier0.95 Infiltration Equipment sensible load4758Btuh Latent Cooling Equipment Load Sizing MethodSimplified Construction qualitySemi-tight Fireplaces0Structure433Btuh Ducts0Btuh Central vent (58 cfm)0Btuh HeatingCooling Area(ft²)25052505Equipment latent load433Btuh Volume(ft³)62636263 Equipment Total Load (Sen+Lat) Air changes/hour0.180.105190Btuh Equiv. AVF (cfm)1910Req. total capacity at 0.70 SHR0.6ton Heating Equipment SummaryCooling Equipment Summary Maken/aMaken/a Traden/aTraden/a Modeln/aCondn/a AHRI refn/aCoiln/a AHRI refn/a Efficiencyn/aEfficiencyn/a Heating inputSensible cooling0Btuh Heating output0BtuhLatent cooling0Btuh Temperature rise0°FTotal cooling0Btuh Actual air flow0cfmActual air flow0cfm Air flow factor0cfm/BtuhAir flow factor0cfm/Btuh Static pressure0in H2OStatic pressure0in H2O Space thermostatn/aLoad sensible heat ratio0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Project Summary Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com Notes:INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Design Information Weather:Idaho Falls Rgnl, ID, US Winter Design ConditionsSummer Design Conditions Outside db-7°FOutside db90°F Inside db70°FInside db75°F Design TD77°FDesign TD15°F Daily rangeH Relative humidity50% Moisture difference-29gr/lb Heating SummarySensible Cooling Equipment Load Sizing Structure24663BtuhStructure17164Btuh Ducts0BtuhDucts0Btuh Central vent (50 cfm)0BtuhCentral vent (50 cfm)0Btuh Humidification0BtuhBlower0Btuh Piping0Btuh Equipment load24663BtuhUse manufacturer's datan Rate/swing multiplier0.95 Infiltration Equipment sensible load16237Btuh Latent Cooling Equipment Load Sizing MethodSimplified Construction qualitySemi-tight Fireplaces0Structure41Btuh Ducts0Btuh Central vent (50 cfm)0Btuh HeatingCooling Area(ft²)21902190Equipment latent load41Btuh Volume(ft³)1970919709 Equipment Total Load (Sen+Lat) Air changes/hour0.190.1016278Btuh Equiv. AVF (cfm)6333Req. total capacity at 0.70 SHR1.9ton Heating Equipment SummaryCooling Equipment Summary Maken/aMaken/a Traden/aTraden/a Modeln/aCondn/a AHRI refn/aCoiln/a AHRI refn/a Efficiencyn/aEfficiencyn/a Heating inputSensible cooling0Btuh Heating output0BtuhLatent cooling0Btuh Temperature rise0°FTotal cooling0Btuh Actual air flow0cfmActual air flow0cfm Air flow factor0cfm/BtuhAir flow factor0cfm/Btuh Static pressure0in H2OStatic pressure0in H2O Space thermostatn/aLoad sensible heat ratio0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 3 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameEntire HouseMain Zone 2Exposed wall421.0ft202.5ft 3Room height9.0ft9.0ft 4Room dimensions 5Room area4695.1ft²2189.9ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.994.990.480.4829529514691422952951469142 .WW15B19-0wc-615B19-0wc-60.0690.069nn3.623.620.030.033653151139100000 .GG4A5-2ov4A5-2ov0.4700.470nn36.0536.0512.7512.7550018026370000 .WW12F-0sw12F-0sw0.0650.065ee4.994.990.480.4861748924372356174892437235 11GG4A5-2ov4A5-2ov0.4700.470ee36.0536.0545.8745.877002523321170025233211 DD11D011D00.3900.390ee29.9129.917.257.255858172741958581727419 WW15B19-0wc-615B19-0wc-60.0690.069ee3.853.850.050.056196192383320000 WW12F-0sw12F-0sw0.0650.065ss4.994.990.480.4829527213551312952721355131 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.81230829709230829709 WW15B19-0wc-615B19-0wc-60.0690.069ss3.693.690.040.043653291214120000 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.81360129811090000 WW12F-0sw12F-0sw0.0650.065ww4.994.990.480.4861750225052426175022505242 GG4A5-2ov4A5-2ov0.4700.470ww36.0536.0545.8745.879103292419091032924190 DD11D011D00.3900.390ww29.9129.917.257.2523236811652323681165 WW15B19-0wc-615B19-0wc-60.0690.069ww3.803.800.050.056195962263280000 DD11D011D00.3900.390ww29.9129.917.257.2523236811650000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.8425052505384321092190219033591844 FF21A-28v21A-28v0.0220.022--1.691.690.000.0025052505422700000 6c) AED excursion01038 Envelope loss/gain35669135452017812325 12a)Infiltration58295844485449 b)Room ventilation0000 13Internal gains:Occupants @230230613803690 Appliances/other46003700 Subtotal (lines 6 to 13)41499201092466317164 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal41499201092466317164 15Duct loads0%0%000%0%00 Total room load41499201092466317164 Air required (cfm)Air required (cfm)117012656951073 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room name(Rest of House) 2Exposed wall218.5ft 3Room height9.0ft 4Room dimensions 5Room area2505.3ft² TyConstructionU-valueOrHTMArea(ft²)LoadAreaLoad number(Btuh/ft²-°F)(Btuh/ft²)orperimeter(ft)(Btuh)orperimeter HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6W12F-0sw0.065n4.990.480000 .W15B19-0wc-60.069n3.620.03365315113910 .G4A5-2ov0.470n36.0512.755001802637 .W12F-0sw0.065e4.990.480000 11G4A5-2ov0.470e36.0545.870000 D11D00.390e29.917.250000 W15B19-0wc-60.069e3.850.05619619238332 W12F-0sw0.065s4.990.480000 G4A5-2ov0.470s36.0530.810000 W15B19-0wc-60.069s3.690.04365329121412 G4A5-2ov0.470s36.0530.8136012981109 W12F-0sw0.065w4.990.480000 G4A5-2ov0.470w36.0545.870000 D11D00.390w29.917.250000 W15B19-0wc-60.069w3.800.05619596226328 D11D00.390w29.917.252323681165 C16B-50ad0.020-1.530.84315315484266 F21A-28v0.022-1.690.002505250542270 6c) AED excursion1046 Envelope loss/gain154913305 12a)Infiltration1344135 b)Room ventilation00 13Internal gains:Occupants @2303690 Appliances/other900 Subtotal (lines 6 to 13)168365029 Less external load00 Less transfer00 Redistribution00 14Subtotal168365029 15Duct loads0%0%00 Total room load168365029 Air required (cfm)475314 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room name(Rest of House)Storage 2Exposed wall218.5ft8.0ft 3Room height9.0ft9.0ftheat/cool 4Room dimensions1.0x270.7ft 5Room area2505.3ft²270.7ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn0.000.000.000.0000000000 .WW15B19-0wc-615B19-0wc-60.0690.069nn3.623.620.030.033653151139100000 .GG4A5-2ov4A5-2ov0.4700.470nn36.0536.0512.7512.7550018026370000 .WW12F-0sw12F-0sw0.0650.065ee0.000.000.000.0000000000 11GG4A5-2ov4A5-2ov0.4700.470ee0.000.000.000.0000000000 DD11D011D00.3900.390ee0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ee3.853.850.050.0561961923833272722774 WW12F-0sw12F-0sw0.0650.065ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ss3.693.690.040.043653291214120000 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.81360129811090000 WW12F-0sw12F-0sw0.0650.065ww0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ww3.803.800.050.056195962263280000 DD11D011D00.3900.390ww29.9129.917.257.2523236811650000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.843153154842660000 FF21A-28v21A-28v0.0220.022--1.691.690.000.0025052505422702712714570 6c) AED excursion10460 Envelope loss/gain1549133057344 12a)Infiltration1344135495 b)Room ventilation0000 13Internal gains:Occupants @230230369000 Appliances/other9000 Subtotal (lines 6 to 13)1683650297839 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution00-783-9 14Subtotal16836502900 15Duct loads0%0%00-0%0%00 Total room load16836502900 Air required (cfm)Air required (cfm)47531400 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 3 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameBedroom 3B TR 2Exposed wall30.3ft3.0ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions1.0x210.5ft8.0x3.0ft 5Room area210.5ft²24.0ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn0.000.000.000.0000000000 .WW15B19-0wc-615B19-0wc-60.0690.069nn3.623.620.030.0300000000 .GG4A5-2ov4A5-2ov0.4700.470nn36.0536.0512.7512.7500000000 .WW12F-0sw12F-0sw0.0650.065ee0.000.000.000.0000000000 11GG4A5-2ov4A5-2ov0.4700.470ee0.000.000.000.0000000000 DD11D011D00.3900.390ee0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ee3.853.850.050.0516216262480000 WW12F-0sw12F-0sw0.0650.065ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ss3.693.690.040.0411094340327271041 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.811605774930000 WW12F-0sw12F-0sw0.0650.065ww0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ww3.803.800.050.0500000000 DD11D011D00.3900.390ww29.9129.917.257.2500000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.8400000000 FF21A-28v21A-28v0.0220.022--1.691.690.000.0021121135502424400 6c) AED excursion3750 Envelope loss/gain18968791451 12a)Infiltration18619182 b)Room ventilation0000 13Internal gains:Occupants @230230123000 Appliances/other00 Subtotal (lines 6 to 13)208211271633 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution223200 14Subtotal230511301633 15Duct loads-0%0%00-0%0%00 Total room load230511301633 Air required (cfm)Air required (cfm)657150 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 4 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameB BathBedroom 4 2Exposed wall5.3ft30.3ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions8.0x5.3ft18.0x12.3ft 5Room area42.0ft²220.5ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn0.000.000.000.0000000000 .WW15B19-0wc-615B19-0wc-60.0690.069nn3.623.620.030.0300000000 .GG4A5-2ov4A5-2ov0.4700.470nn36.0536.0512.7512.7500000000 .WW12F-0sw12F-0sw0.0650.065ee0.000.000.000.0000000000 11GG4A5-2ov4A5-2ov0.4700.470ee0.000.000.000.0000000000 DD11D011D00.3900.390ee0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ee3.853.850.050.0500000000 WW12F-0sw12F-0sw0.0650.065ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ss3.693.690.040.0447431612110943403 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.8140144123160577493 WW12F-0sw12F-0sw0.0650.065ww0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ww3.803.800.050.0500001621626248 DD11D011D00.3900.390ww29.9129.917.257.2500000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.8400000000 FF21A-28v21A-28v0.0220.022--1.691.690.000.0042427102212213720 6c) AED excursion94375 Envelope loss/gain3762191913879 12a)Infiltration32318619 b)Room ventilation0000 13Internal gains:Occupants @230230001230 Appliances/other00 Subtotal (lines 6 to 13)40822220991127 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution001773 14Subtotal40822222761130 15Duct loads-0%0%00-0%0%00 Total room load40822222761130 Air required (cfm)Air required (cfm)12146471 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 5 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameMechFamily Rm 2Exposed wall8.0ft63.0ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions8.0x13.8ft1.0x1041.2ft 5Room area110.0ft²1041.2ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn0.000.000.000.0000000000 .WW15B19-0wc-615B19-0wc-60.0690.069nn3.623.620.030.0300001621324653 .GG4A5-2ov4A5-2ov0.4700.470nn36.0536.0512.7512.7500003001081382 .WW12F-0sw12F-0sw0.0650.065ee0.000.000.000.0000000000 11GG4A5-2ov4A5-2ov0.4700.470ee0.000.000.000.0000000000 DD11D011D00.3900.390ee0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ee3.853.850.050.0500002020781 WW12F-0sw12F-0sw0.0650.065ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ss3.693.690.040.0400000000 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.8100000000 WW12F-0sw12F-0sw0.0650.065ww0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ww3.803.800.050.0572722774385362136216 DD11D011D00.3900.390ww29.9129.917.257.2500002323681165 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.8400002221 FF21A-28v21A-28v0.0220.022--1.691.690.000.0011011018601041104117570 6c) AED excursion0121 Envelope loss/gain46345426690 12a)Infiltration49538839 b)Room ventilation0000 13Internal gains:Occupants @2302300000 Appliances/other0900 Subtotal (lines 6 to 13)512958141628 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution-512-91871108 14Subtotal0076851736 15Duct loads-0%0%00-0%0%00 Total room load0076851736 Air required (cfm)Air required (cfm)00217109 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 6 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameBedroom 2Cold Storage 2Exposed wall14.8ft56.0ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions1.0x272.5ft40.5x7.8ft 5Room area272.5ft²313.9ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn0.000.000.000.0000000000 .WW15B19-0wc-615B19-0wc-60.0690.069nn3.623.620.030.03133113406370702694 .GG4A5-2ov4A5-2ov0.4700.470nn36.0536.0512.7512.752007212550000 .WW12F-0sw12F-0sw0.0650.065ee0.000.000.000.0000000000 11GG4A5-2ov4A5-2ov0.4700.470ee0.000.000.000.0000000000 DD11D011D00.3900.390ee0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ee3.853.850.050.050000365365140419 WW12F-0sw12F-0sw0.0650.065ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ss3.693.690.040.04000070702694 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.8100000000 WW12F-0sw12F-0sw0.0650.065ww0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 WW15B19-0wc-615B19-0wc-60.0690.069ww3.803.800.050.0500000000 DD11D011D00.3900.390ww29.9129.917.257.2500000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.840000314314481264 FF21A-28v21A-28v0.0220.022--1.691.690.000.0027327346003143145300 6c) AED excursion82-1 Envelope loss/gain15863402953290 12a)Infiltration91934535 b)Room ventilation0000 13Internal gains:Occupants @230230123000 Appliances/other00 Subtotal (lines 6 to 13)16775793297324 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution2321228-3297-324 14Subtotal399880700 15Duct loads-0%0%00-0%0%00 Total room load399880700 Air required (cfm)Air required (cfm)1135000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 7 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameMain ZoneMaster 2Exposed wall202.5ft34.0ft 3Room height9.0ft9.0ftheat/cool 4Room dimensions17.3x16.8ft 5Room area2189.9ft²288.9ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.994.990.480.4829529514691420000 .WW15B19-0wc-615B19-0wc-60.0690.069nn0.000.000.000.0000000000 .GG4A5-2ov4A5-2ov0.4700.470nn0.000.000.000.0000000000 .WW12F-0sw12F-0sw0.0650.065ee4.994.990.480.4861748924372350000 11GG4A5-2ov4A5-2ov0.4700.470ee36.0536.0545.8745.87700252332110000 DD11D011D00.3900.390ee29.9129.917.257.25585817274190000 WW15B19-0wc-615B19-0wc-60.0690.069ee0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ss4.994.990.480.48295272135513115115175273 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.812308297090000 WW15B19-0wc-615B19-0wc-60.0690.069ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ww4.994.990.480.48617502250524215512562460 GG4A5-2ov4A5-2ov0.4700.470ww36.0536.0545.8745.879103292419030010811376 DD11D011D00.3900.390ww29.9129.917.257.2523236811650000 WW15B19-0wc-615B19-0wc-60.0690.069ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.842190219033591844289289443243 FF21A-28v21A-28v0.0220.022--0.000.000.000.0000000000 6c) AED excursion1038347 Envelope loss/gain201781232529012100 12a)Infiltration448544975375 b)Room ventilation0000 13Internal gains:Occupants @23023036902460 Appliances/other37000 Subtotal (lines 6 to 13)246631716436542635 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution002010 14Subtotal246631716436732645 15Duct loads0%0%00-0%0%00 Total room load246631716436732645 Air required (cfm)Air required (cfm)6951073104165 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 8 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameM WICBedroom 1 2Exposed wall0ft13.5ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions8.8x6.8ft1.0x150.6ft 5Room area59.1ft²150.6ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.994.990.480.4800000000 .WW15B19-0wc-615B19-0wc-60.0690.069nn0.000.000.000.0000000000 .GG4A5-2ov4A5-2ov0.4700.470nn0.000.000.000.0000000000 .WW12F-0sw12F-0sw0.0650.065ee4.994.990.480.4800001229748146 11GG4A5-2ov4A5-2ov0.4700.470ee36.0536.0545.8745.8700002509011147 DD11D011D00.3900.390ee29.9129.917.257.2500000000 WW15B19-0wc-615B19-0wc-60.0690.069ee0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ss4.994.990.480.4800000000 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.8100000000 WW15B19-0wc-615B19-0wc-60.0690.069ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ww4.994.990.480.4800000000 GG4A5-2ov4A5-2ov0.4700.470ww36.0536.0545.8745.8700000000 DD11D011D00.3900.390ww29.9129.917.257.2500000000 WW15B19-0wc-615B19-0wc-60.0690.069ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.8459599150151151231127 FF21A-28v21A-28v0.0220.022--0.000.000.000.0000000000 6c) AED excursion-493 Envelope loss/gain914616131413 12a)Infiltration0029930 b)Room ventilation0000 13Internal gains:Occupants @230230001230 Appliances/other00 Subtotal (lines 6 to 13)914619121673 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution-91-4634672 14Subtotal0022581745 15Duct loads-0%0%00-0%0%00 Total room load0022581745 Air required (cfm)Air required (cfm)0064109 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 9 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameM BathBath 2Exposed wall8.8ft6.5ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions8.8x10.0ft11.0x6.5ft 5Room area87.5ft²71.5ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.994.990.480.4800000000 .WW15B19-0wc-615B19-0wc-60.0690.069nn0.000.000.000.0000000000 .GG4A5-2ov4A5-2ov0.4700.470nn0.000.000.000.0000000000 .WW12F-0sw12F-0sw0.0650.065ee4.994.990.480.4800000000 11GG4A5-2ov4A5-2ov0.4700.470ee36.0536.0545.8745.8700000000 DD11D011D00.3900.390ee29.9129.917.257.2500000000 WW15B19-0wc-615B19-0wc-60.0690.069ee0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ss4.994.990.480.480000594823723 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.810000110397339 WW15B19-0wc-615B19-0wc-60.0690.069ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ww4.994.990.480.487971351340000 GG4A5-2ov4A5-2ov0.4700.470ww36.0536.0545.8745.87802973780000 DD11D011D00.3900.390ww29.9129.917.257.2500000000 WW15B19-0wc-615B19-0wc-60.0690.069ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.84888813474727211060 FF21A-28v21A-28v0.0220.022--0.000.000.000.0000000000 6c) AED excursion105206 Envelope loss/gain783591743628 12a)Infiltration1941914414 b)Room ventilation0000 13Internal gains:Occupants @2302300000 Appliances/other00 Subtotal (lines 6 to 13)977610887642 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution261300 14Subtotal1002623887642 15Duct loads-0%0%00-0%0%00 Total room load1002623887642 Air required (cfm)Air required (cfm)28392540 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 10 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room namelaundryPantry 2Exposed wall24.8ft6.3ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions15.3x9.5ft1.0x81.4ft 5Room area144.9ft²81.4ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.994.990.480.4800000000 .WW15B19-0wc-615B19-0wc-60.0690.069nn0.000.000.000.0000000000 .GG4A5-2ov4A5-2ov0.4700.470nn0.000.000.000.0000000000 .WW12F-0sw12F-0sw0.0650.065ee4.994.990.480.4813711557155564421921 11GG4A5-2ov4A5-2ov0.4700.470ee36.0536.0545.8745.8700000000 DD11D011D00.3900.390ee29.9129.917.257.252323681165121236689 WW15B19-0wc-615B19-0wc-60.0690.069ee0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ss4.994.990.480.488674366350000 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.811204333700000 WW15B19-0wc-615B19-0wc-60.0690.069ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ww4.994.990.480.4800000000 GG4A5-2ov4A5-2ov0.4700.470ww36.0536.0545.8745.8700000000 DD11D011D00.3900.390ww29.9129.917.257.2500000000 WW15B19-0wc-615B19-0wc-60.0690.069ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.84145145222122818112569 FF21A-28v21A-28v0.0220.022--0.000.000.000.0000000000 6c) AED excursion161-15 Envelope loss/gain2273908711164 12a)Infiltration5485513814 b)Room ventilation0000 13Internal gains:Occupants @2302300000 Appliances/other5000 Subtotal (lines 6 to 13)28211463849178 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution23950-849-178 14Subtotal3060151300 15Duct loads-0%0%00-0%0%00 Total room load3060151300 Air required (cfm)Air required (cfm)869500 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 11 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Right-J®Worksheet Job:Ott Date:9/18/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Ott 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameOfficeKit/Din/Great Rm 2Exposed wall26.8ft82.0ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions1.0x163.3ft1.0x1142.6ft 5Room area163.3ft²1142.6ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.994.990.480.481061065275118918994291 .WW15B19-0wc-615B19-0wc-60.0690.069nn0.000.000.000.0000000000 .GG4A5-2ov4A5-2ov0.4700.470nn0.000.000.000.0000000000 .WW12F-0sw12F-0sw0.0650.065ee4.994.990.480.481351105485316712461760 11GG4A5-2ov4A5-2ov0.4700.470ee36.0536.0545.8745.872509011147200721917 DD11D011D00.3900.390ee29.9129.917.257.2500002323681165 WW15B19-0wc-615B19-0wc-60.0690.069ee0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ss4.994.990.480.4800000000 GG4A5-2ov4A5-2ov0.4700.470ss36.0536.0530.8130.8100000000 WW15B19-0wc-615B19-0wc-60.0690.069ss0.000.000.000.0000000000 GG4A5-2ov4A5-2ov0.4700.470ss0.000.000.000.0000000000 WW12F-0sw12F-0sw0.0650.065ww4.994.990.480.4800003833071529148 GG4A5-2ov4A5-2ov0.4700.470ww36.0536.0545.8745.87000053019142435 DD11D011D00.3900.390ww29.9129.917.257.2500002323681165 WW15B19-0wc-615B19-0wc-60.0690.069ww0.000.000.000.0000000000 DD11D011D00.3900.390ww0.000.000.000.0000000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.840.84163163251138114311431753962 FF21A-28v21A-28v0.0220.022--0.000.000.000.0000000000 6c) AED excursion8066 Envelope loss/gain2227146888375008 12a)Infiltration592591816182 b)Room ventilation0000 13Internal gains:Occupants @2302300000 Appliances/other3002900 Subtotal (lines 6 to 13)28201827106538090 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0030978 14Subtotal28201827109628168 15Duct loads-0%0%00-0%0%00 Total room load28201827109628168 Air required (cfm)Air required (cfm)80114309511 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-18 16:28:55 Right-Suite®Universal201919.0.20RSU28163 Page 12 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E N Basement 108cfm 71 cfm Cfesppn!5 6 " Nfdi 6 "6 " 6 " 8 " 8 x 8 71 cfm 6 " 10 x 8 14x3.25 6 " 8 x 8 6 " Gbnjmz!Sn 6 " 6 " 8 " 36 x 8 14 cfm C!Cbui 6 "6 " 108cfm 18 x 8 12 x 8 14 x 8 2-14x3.25 2-14x3.25 14x3.25 10 x 8 4-14x3.25 6 " 5 cfm14x3.25 C!US 14x3.25 8 " 26 x 8 233cfm 14x3.25113cfm 6 " 71 cfm 6 "8 " 6 " 71 cfm Tupsbhf 113cfm Cfesppn!3 Cfesppn!4 Dpme!Tupsbhf Job #: Ott Scale: 1 : 116 Mechanical Compliance Solutions Performed by Gene Miller for: Page 1 Alpine Heating And Air 4181 Aschli lane Right-Suite®Universal2019 170 N Eastern Ave Idaho Falls, ID 83406 19.0.20 RSU28163 Idaho Falls,, Idaho Phone: 208-881-3243 2020-Sep-18 16:29:17 Phone: 208-523-5542 gene.mechcompliancesolutions@gmail.com ...tloss's\\Alpine\\Otts Home\\Ott.rup derik@alpineheatingair.com N Main Floor 83 cfm83 cfm 102cfm 102cfm 102cfm N!Cbui Nbtufs 39 cfm N!XJD Lju0Ejo0Hsfbu!Sn 204cfm 102cfm Cbui 645cfm 40 cfm109cfm 114cfm Qbousz Cfesppn!2Pggjdf mbvoesz 95 cfm 109cfm114cfm 102cfm Job #: Ott Scale: 1 : 116 Mechanical Compliance Solutions Performed by Gene Miller for: Page 2 Alpine Heating And Air 4181 Aschli lane Right-Suite®Universal2019 170 N Eastern Ave Idaho Falls, ID 83406 19.0.20 RSU28163 Idaho Falls,, Idaho Phone: 208-881-3243 2020-Sep-18 16:29:17 Phone: 208-523-5542 gene.mechcompliancesolutions@gmail.com ...tloss's\\Alpine\\Otts Home\\Ott.rup derik@alpineheatingair.com Duct System Summary Job:Ott Date:9/18/2020 By:Gene Miller Plan:Ott Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Alpine Heating And Air 170 N Eastern Ave, Idaho Falls,, Idaho Phone: 208-523-5542 Email: derik@alpineheatingair.com HeatingCooling External static pressure0.90in H2O0.90in H2O Pressure losses0.41in H2O0.41in H2O Available static pressure0.49in H2O0.49in H2O Supply / return available pressure0.195 / 0.295in H2O0.195 / 0.295in H2O Lowest friction rate0.085in/100ft0.085in/100ft Actual air flow1170cfm1265cfm Total effective length (TEL)576ft Supply Branch Detail Table DesignHtgClgDesignDiamH x WDuctActualFtg.Eqv Name(Btuh)(cfm)(cfm)FR(in)(in)MatlLn (ft)Ln (ft)Trunk B Bath c22212140.1166.00x0ShMt13.3155.0st4 B TR h163500.1106.00x0ShMt16.5160.0st4 Bath c64225400.1096.00x0ShMt18.8160.0st3 Bedroom 1 c1745641090.1036.00x0ShMt29.0160.0st2 Bedroom 2 h3998113500.0878.00x0ShMt58.3165.0st1A Bedroom 3 c113065710.1066.00x0ShMt29.1155.0st4 Bedroom 4 c113064710.1166.00x0ShMt23.3145.0st4 Family Rm h3843108540.1126.00x0ShMt28.8145.0st1 Family Rm-A h3843108540.0968.00x0ShMt48.3155.0st1A Kit/Din/Great Rm c1634621020.1036.00x0ShMt44.5145.0st2 Kit/Din/Great Rm-A c1634621020.1026.00x0ShMt36.0155.0st2 Kit/Din/Great Rm-B c1634621020.0888.00x0ShMt46.3175.0st2A Kit/Din/Great Rm-C c1634621020.0886.00x0ShMt55.3165.0st2A Kit/Din/Great Rm-D c1634621020.0956.00x0ShMt49.5155.0st2A M Bath c62328390.1116.00x0ShMt6.3170.0st3 Master c132252830.1076.00x0ShMt27.8155.0st3 Master-A c132252830.1076.00x0ShMt17.3165.0st3 Office c1827801140.0858.00x0ShMt59.0170.0st2A laundry c151386950.1106.00x0ShMt31.5145.0st3 2020-Sep-18 16:28:56 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E Supply Trunk Detail Table TrunkHtgClgDesignVelocDiamH x WDuct NameType(cfm)(cfm)FR(fpm)(in)(in)MaterialTrunk st4Peak AVF1451550.1063506.88x8ShtMetl st3Peak AVF2433390.1076109.18x10ShtMetl st1Peak AVF3291590.0875939.38x10ShtMetl st1APeak AVF2211050.0874978.18x8ShtMetlst1 st2Peak AVF4527340.08573412.78x18ShtMetl st2APeak AVF2654210.08563110.38x12ShtMetlst2 Return Branch Detail Table GrilleHtgClgTELDesignVelocDiamH x WStud/JoistDuct NameSize (in)(cfm)(cfm)(ft)FR(fpm)(in)(in)Opening (in)MatlTrunk rb70x064109170.00.1743455.43.25x1410x9SJSprt2 rb60x0132204230.10.1283237.22-3.25x142-10x18SJSprt3 rb80x080114316.00.0933626.23.25x1410x9SJSprt2 rb10x0233123204.30.1453687.42-3.25x142-10x18SJSprt2 rb20x0420645244.80.12151111.34-3.25x144-10x36SJSprt3 rb30x06471260.00.1142245.03.25x1410x9SJSprt3 rb40x06571335.00.0882245.23.25x1410x9SJSprt3 rb50x011350347.00.0853576.33.25x1410x9SJSprt2 Return Trunk Detail Table TrunkHtgClgDesignVelocDiamH x WDuct NameType(cfm)(cfm)FR(fpm)(in)(in)MaterialTrunk rt2Peak AVF4893960.08562810.98x14ShtMetlrt1 rt3Peak AVF6819910.08868614.18x26ShtMetlrt1 rt1Peak AVF117013870.08569416.18x36ShtMetl 2020-Sep-18 16:28:56 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...cuments\\MCS Heatloss's\\Alpine\\Otts Home\\Ott.rup Calc = MJ8 Front Door faces: E