Loading...
HomeMy WebLinkAboutREVIEW ACTION - 08-00040 - BYU-I Auditorium - Chiller Building Addition (2)—_C IT Y OF J 12EXOw n, Amerita5 FBmil�• CBmmuriiry• P.0 Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Review Action Fax (208) 359-3022 February 26, 2008 oiIQQQ Permit Number: 08 00040 f-0 DWO-9 Project Name: Chiller Bldg Addition (Qk wwk- ld Project Type: Commercial Addition Review Item Actions Required for Approval Approved Administrative Review Permit Tech Notes Parcel #'s RPROOOP0140010 Plumbing contractor signature and estimate needed. Electrical contractor signature and estimate needed. Mechanical contractor signature and estimate needed. 0 CITY OF REXBURG Amenm} Fonlly Com rrue:,: February 26, 2008 Permit Number: 08 00040 Project Name: Chiller Bldg Addition Project Type: Commercial Addition Review Action P.O Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 Review Item Actions Required for Approval Approved Building Department Review Electrical Service Review 01/29/2008 Electrical Circuits Review 01/29/2008 Electrical Energy Lighting Compliance Review 01/29/2008 Accessibility Review The exiting does not need to meet accessible 02/04/2008 standards as per IBC 1103.2.5. Energy Conservation Compliance Review The plans show 2 " of rigid insulation on walls. 02/04/2008 Usually we associate R5 for each inch. The energy review identifies R15. R30 is shown on energy review. Identify thickness of insulation to equal R30. CI I OF REXBURG Amena6 FaWly Community February 26, 2008 Permit Number: 08 00040 Project Name: Chiller Bldg Addition Project Type: Commercial Addition Review Action P.O Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 Review Item Actions Required for Approval Approved The plans show 2" of ridgid insulation. Identify how R15 was reached. (0 CITY OF MXBURG Ami.' F=11Y Community February 26, 2008 Permit Number: 08 00040 Project Name: Chiller Bldg Addition Project Type: Commercial Addition Review Item Height and Area Review Exiting Review Building Type Compliance Building Code Fire Compliance Review Structural Review Water and Sewer Service Plumbing Sewer Drain Review Plumbing Potable Water Review Plumbing Storm Drain Review Mechanical Review Review Action Meets code requirements. Meets code requirements. Building is Type IIB. Occupancy is U. Meets code requirements. Meets code requirements. Special inspections are required on foundation walls, structural masonry, welding and high strength bolting. All plumbing services are required to tested and inspected before covering. All indirect drains are required to discharge to an approved indirect waste receptor. Floor drains are not approved as indirect waste receptors. The combination waste and vent system is undersized. Please make proper adjustments and resubmit plans with the proper sizing. All water lines that are not used for potable water are required to be labeled as required by the Uniform Plumbing Code. All water lines are required to have the proper Backflow prevention devices installed, tested and inspected as requirerd by the Uniform Plumbing Code. All storm water piping is required to be tested and inspected before covering. Not reviewed at this time. In process and to be handled seperately. P.O Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 02/04/2008 02/04/2008 02/04/2008 02/04/2008 02/04/2008 eezeuec, --CITY OF REXBURG Amm6m's F WIy Community February 26, 2008 Permit Number: 08 00040 Project Name: Chiller Bldg Addition Project Type: Commercial Addition Review Item Fire Department Review Required Fire Flow Standpipes Other Comments Alarm Systems Commercial Cooking Automatic Fire Extinguishing Systems Water Supply Fire Extinguishers Fire Access Roads Parcel#'s RPROOOP0140010 Review Action RO Box 280 19 E Main Sl. Rexburg, Idaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022 AcUon-5 Required for Approval Approved See site plan review. 02/05/2008 N/A 02/05/2008 All keys for the new addition need to be placed 02/05/2008 in the lock box upon completetion of project. Submit plans to the City of Rexburg for 02/05/2008 approval. Plans are required to be approved before any working on the fire alarm system. N/A 02/05/2008 Submit automatic fire sprinkler plans to the 02/05/2008 State Fire Marshall for approval. All plans are required to be approved before work begins on the fire suppression system. See site plan review. 02/05/2008 Fire extinguishers are required for this 02/05/2008 occupancy. Please install all fire extinguishers prior to final fire inspection. Install according to the 2006 edition of the International Fire Code and NFPA. See site plan review. 02/05/2008 (0 CITY OF REXBURG Mmmnw's Famin• Community February 26, 2008 Review Action P.o Box 280 19 E Main St. Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 Permit Number: 08 00040 Project Name: Chiller Bldg Addition Project Type: Commercial Addition Review Item Actions Required for Approval _ Approved Planning Staff Review Development Standards Review Building needs to incorporate horizontal band or similar element that will reduce the scale of the building. Band should be of diferent color and or material from the overall wall. Development Standards Review No mechanical equipment can be visible from public right of way. Please provide evidence that this will not occur. This includes rooftop equipment as well as any ground equipment. Development Standards Review Provide landscaping that will further screen or reduce scale of proposed walls. Of particular concern are the north and northwest walls. See site plan reivew notes for recomended minimum plant sizes. Parcel #'s RPROOOP0140010