PRODUCT INFO - 20-00625 - Madison Memorial Hospital - Fire Alarm
TrueAlarmAnalog Sensing TrueAlarm Analog Sensors – Photoelectric UL, ULC, CSFM Listed; FM Approved; and Heat; Standard Bases and Accessories MEA (NYC) Acceptance* Features TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications ® For use with the following Simplex products: 4100ES, 4100U, 4010ES, and 4010 Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped 4098-9714 TrueAlarm Photoelectric for MAPNET II operation Sensor Mounted in Base Fire alarm control panel provides: Description Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Digital Communication of Analog Sensing. Sensitivity monitoring satisfying NFPA 72 sensitivity TrueAlarm analog sensors provide an analog testing requirements; automatic individual sensor measurement digitally communicated to the host control calibration check verifies sensor integrity panel using Simplex addressable communications. At the Automatic environmental compensation, multi-stage control panel, the data is analyzed and an average value is alarm operation, and display of sensitivity directly in determined and stored. An alarm or other abnormal percent per foot condition is determined by comparing the sensor’s present Ability to display and print detailed sensor value against its average value and time. information in plain English language Intelligent Data Evaluation. Monitoring each sensor’s Photoelectric smoke sensors provide: average value provides a continuously shifting reference Seven levels of sensitivity from 0.2% to 3.7% point. This software filtering process compensates for (refer to additional information on page 3) environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new Heat sensors provide: activity. With this filtering, there is a significant reduction Fixed temperature sensing in the probability of false or nuisance alarms caused by Rate-of-rise temperature sensing shifts in sensitivity, either up or down. Utility temperature sensing Control Panel Selection. Peak activity per sensor is Listed to UL 521 and ULC-S530 stored to assist in evaluating specific locations. The alarm General features: set point for each TrueAlarm sensor is determined at the Listed to UL 268 and ULC-S529 host control panel, selectable as more or less sensitive as the individual application requires. Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas Timed/Multi-Stage Selection. Sensor alarm set points are minimally visible when ceiling mounted can be programmed for timed automatic sensitivity Designed for EMI compatibility selection (such as more sensitive at night, less sensitive Magnetic test feature is provided during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% Optional accessories include remote LED alarm level may cause a warning to prompt investigation while a indicator and output relays 2.5% level may initiate an alarm. Additional base reference: Sensor Alarm and Trouble LED Indication. Each For isolator bases, refer to data sheet S4098-0025 sensor base’s LED pulses to indicate communications For sounder bases, refer to data sheet S4098-0028 with the panel. If the control panel determines a sensor is For photo/heat sensors, refer to data sheet S4098-0024 in alarm, or is dirty or has some other type of trouble, the (single address) and S4098-0033 (dual address) details are annunciated at the control panel and that sensor * base’s LED will be turned on steadily. During a system These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings alarm, the control panel will control the LEDs such that 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values an LED indicating a trouble will return to pulsing to help and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable, identify the alarmed sensors. contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4098-0019-16 10/2013 True Sensor Bases and Accessories Alarm Description Sensor Base Features TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the Base mounted address selection: detachable photoelectric or heat sensors. Each sensor’s Address remains with its programmed location output is digitized and transmitted to the system fire alarm control panel every four seconds. Accessible from front (DIP switch under sensor) General features: Since TrueAlarm sensors use the same base, different Automatic identification provides default sensitivity sensor types can be easily interchanged to meet specific when substituting sensor types location requirements. This feature also allows intentional sensor substitution during building construction. When Integral red LED for power-on (pulsing), or alarm or conditions are temporarily dusty, instead of covering the trouble (steady on) smoke sensors (causing them to be disabled), heat sensors Locking anti-tamper design mounts on standard outlet may be installed without reprogramming the control box panel. Although the control panel will indicate an Magnetically operated functional test incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building Sensor Bases protection at that location. 4098-9792, Standard sensor base Mounting Reference 4098-9789, Sensor base with wired connections for: or 2098-9808 Remote LED alarm indicator 4098-9822 Electrical Box Requirements: (boxes are by others) relay (unsupervised) Without relay: 4" octagonal or 4" square, 1-1/2" deep; 4098-9791, Sensor base with supervised relay driver single gang, 2" deep output : (not compatible with 2120 CDT) With relay : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring Relay operation is programmable and can be manually operated from control panel 4" (102 mm) Square Box4" (102 mm) Octagonal Box Surface mount reference Use with remote mount 2098-9737 relay Also includes wired connections for remote LED alarm or indicator 4098-9822 relay Sensor Base Options 2098-9737, Remote or local mount supervised relay:1-1/2" (38 mm) minimum box depth DPDT contacts for resistive/suppressed loads, power Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC 2098-9737 Relay (mounts in4098-9822 Relay (mounts coil power) base electrical box or remotely)in base electrical box) 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 cubic inches) coil power) (64 mm X 38 mm X 25.4 mm) 4098-9832, Adapter plate: NOTE: Review total wire count, wire size, and accessories Required for surface or semi-flush mounting to being wired to determine required box volume. 4” square electrical box and for surface mounting to 4” octagonal box 6-3/8" (162 mm) Can be used for cosmetic retrofitting to existing 6-3/8” diameter base product 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes 2098-9808, Remote red LED Alarm (6.4 mm) and 4" square flush box Indicator: 4-7/8" (124 mm) Mounts on single gang box ALARM 15/16" (shown in illustration to right) (24 mm) TrueAlarm Bases 4098-9789, -9791, & -9792 2 S4098-0019-16 10/2013 True Sensors Alarm 4098-9733 Heat Sensor Features TrueAlarm heat sensors are self-restoring and provide rate Sealed against rear air flow entry compensated, fixed temperature sensing, selectable with Interchangeable mounting or without rate-of-rise temperature sensing. Due to its EMI/RFI shielded electronics small thermal mass, the sensor accurately and quickly Heat sensors: measures the local temperature for analysis at the fire Selectable rate compensated, fixed temperature alarm control panel. sensing with or without rate-of-rise operation Rate-of-rise temperature detection is selectable at the Rated spacing distance between sensors: control panel for either 15° F (8.3° C) or 20° F (11.1° C) Fixed Temp. UL & ULC FM Spacing, Either Fixed per minute. Fixed temperature sensing is independent of Setting Spacing Temperature Setting rate-of-rise sensing and programmable to operate at 20 ft x 20 ft (6.1 m) for fixed 135° F 60 ft x 60 ft 135° F (57.2° C) or 155° F (68° C). In a slow developing RTI = Quick temperature only; (57.2° C) (18.3 m) fire, the temperature may not increase rapidly enough to 50 ft x 50 ft (15.2 m) for fixed operate the rate-of-rise feature. However, an alarm will be 155° F 40 ft x 40 ft temperature with either rate-of-rise (68° C) (12.2 m) initiated when the temperature reaches its rated fixed RTI = Ultra Fast selection; temperature setting. Smoke Sensors: TrueAlarm heat sensors can be programmed as a utility Photoelectric technology sensing device to monitor for temperature extremes in the range 360° smoke entry for optimum response from 32° F to 155° F (0° C to 68° C). This feature can Built-in insect screens provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 4098-9714 Photoelectric Sensor 4-7/8" (124 mm) TrueAlarm photoelectric sensors use a stable, pulsed LED status indicator infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power 2-3/8" smoke sensing. Seven levels of sensitivity are available (60 mm) for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, and 3.7%. Sensitivity is selected and monitored at the fire alarm 4098-9733 Heat Sensor with Base control panel.* The sensor head design provides 360° smoke entry for WARNING:In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection optimum response to smoke from any direction. Due to its device would initiate an alarm. In cases where Life photoelectric operation, air velocity is not normally a Safety is a factor, the use of smoke detection is highly factor, except for impact on area smoke flow. recommended. 4-7/8" (124 mm) LED status indicator Application Reference 2-1/8" (54 mm) Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* 4098-9714 Photoelectric Sensor with Base * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-16 10/2013 TrueAlarm Analog Sensing Product Selection Chart TrueAlarm Sensor Bases (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description Compatibility Mounting Requirements 4” octagonal or 4” square box, 1-1/2” min. 4098-9792 Standard Sensor Base, no options Sensors 4098-9714 and 4098-9733 4098-9792 Standard Sensor Base, no options Sensors 4098-9714 and 4098-9733 depth; or single gang box, 2” min. depth Sensors 4098-9714 and 4098-9733 Sensor Base with connections for 4” octagonal or 4” square box 4098-9789 Remote LED Alarm Indicator or 2098-9808 remote LED alarm Note:Box depth requirements depend on Unsupervised Relay indicatoror 4098-9822 relay total wire count and wire size, refer to Sensors 4098-9714 and 4098-9733 Sensor Base with connections for accessories list below for reference. Supervised Remote Relay and2098-9737 remote relay (supervised) 4098-9791** **NOTE: 4098-9791 is NOT compatible connections for Remote Alarm 2098-9808 remote alarm indicator or with the 2120 CDT Indicatoror Unsupervised Relay 4098-9822 relay (unsupervised) TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor 4098-9714 Photoelectric Smoke Sensor Bases 4098-9792, 4098-9789, Refer to base requirements and 4098-9791 4098-9733 Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements Remote Mounting requires 4” octagonal or 4” square box, 1-1/2” minimum depth Supervised Relay, mounts remote 2098-9737 For use with 4098-9791 base or in base electrical box Base Mounting requires 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring Remote Red LED Alarm Indicator 2098-9808 Single gang box, 1-1/2” minimum depth on single gang stainless steel plate Bases 4098-9789 and 4098-9791 Relay, tracks base LED status 4” octagonal box, 2-1/8” deep with 1-1/2” 4098-9822 (unsupervised, mounts only in base extension ring electrical box) Required for surface or semi-flush 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 mounted 4” square box and for surface mounted 4” octagonal box Specifications General Operating Specifications MAPNET II or IDNet, auto-select, 24-40 VDC w/data, 400 A typical, Communications and Sensor Supervisory Power 1 address per base 22 Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm to 2.08 mm) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current 2 Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm ) UL Listed Temperature Range 32° to 100° F (0° to 38° C) with 4098 -973332° to 122° F (0° to 50° C) Operating Temperature Range with 4098-971415° to 122° F (-9° to 50° C) Storage Temperature Range 0° to 140° F (-18° to 60° C) Humidity Range 10 to 95% RH Smoke Sensor4098-9714, Air velocity = 0-4000 ft/min (0-1220 m/min) Ambient Ratings Photoelectric Sensor Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270A, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). S4098-0019-16 10/2013 Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA www.simplexgrinnell.com © 2013 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Addressable Initiation Peripherals IDNet and MAPNET II Communicating Devices UL, ULC, CSFM Listed; Model 4090-9008 Dual Contact Relay IAM FM Approved* Features Dual Contact Relay IAM (Individual Addressable Module): A single addressable point provides control and status 1 2 4 8 tracking of two, 2 A Form “C” contacts 16 32 64 Low power latching relay design allows IDNet or 128 MAPNET II communications to supply both data and module power Relay is set to OFF on initial power up and upon loss of IDNet or MAPNET II communications For use with following Simplex control panels: Model Series 4007ES, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Model Series 4100/4100U/4100ES, 4120, 4020, and 4090-9008 Dual Contact Relay IAM 2120 Communicating Device Transponders (CDTs) (shown approximately 1/2 size) equipped with MAPNET II communications Compact construction: Specifications Mounts in standard 4” (102 mm) square electrical box, optional adapter bracket is available to mount in a 11 4” square electrical box IDNet or MAPNET II communications, 16 Communications 1 address per device Screw terminals for wiring connections Power Supplied by communications Visible LED flashes to indicate communications, can be Installation selected at panel to indicate activated state 579-1040 Instructions Optional 4” square box covers are available to allow IDNet Firmware Requires 3.12.04 or higher LED to be viewed after installation Contact Ratings* (not rated for incandescent switching) UL listed to Standard 864 Dual Form C contacts (DPDT) with Type terminal block access to Common, Description N.O., and N.C for each contact from listed Dual Contact Relay IAMs 2 A @ 30 VDC, resistive allow fire alarm control fire alarm Power-Limited panels to control two remotely located Form “C” contact 1 A @ 30 VDC, inductive supply using IDNet or MAPNET II addressable communications Nonpower-Limited 0.5 A @ 125 VAC, resistive for both data and module power. Typical applications Each contact common is fused with a would be for switching local power for control functions Relay Fusing 2 A fast acting non-time delay fuse such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also * Provide external transient suppression as required per communicated requiring only one device address. application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC networks or Product Selection varistors, depending on device type. Refer to Installation Instructions for additional information. Model Description Screw terminals for in/out wiring, 4090-9008 Dual Contact Relay IAM Wire Connections 4090-9008 Dual Contact Relay IAM 2 18 to 14 AWG wire (0.82 to 2.08 mm) Optional Adapter Plates Up to 2500 ft ( 762 m) from control ModelDescription panel IDNet or 11 Adapter plate to fit 4 Ø MAPNET II Up to 10,000 ft ( 3048 m) total wiring 16 4090-9813 electrical box Communications distance (including T-Taps) Wiring Reference For semi-flush Compatible with Simplex 2081-9044 4090-9801 mounted box Overvoltage Protectors boxes with LED viewing window, includes mounting For surface 4 4090-9802 Dimensions screws; galvanized steel mounted box (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Temperature 32° to 120° F (0° to 49° C), Section 13144.1 of the California Health and Safety Code. See CSFM Listing Range intended for indoor operation 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product Humidity Range Up to 93% RH at 100° F (38° C) supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4090-0014-3 11/2014 Dual Contact Relay IAM Mounting Information 4" (102 mm) square electrical box, 2-1/8" (54 mm) minimum depth (supplied separately) 4-11/16" (119 mm) square electrical box, 2-1/8" (54 mm) minimum depth (supplied separately) 4-11/16" or 4" square cover plate (supplied separately) Use mounting screws supplied with box 4090-9813 Adapter Plate for 4-11/16" square box (includes 4090-9008 Dual Contact 2, #8 mounting screws) Relay IAM Assembly Mounting Reference with 4-11/16" Square and 4" Square Boxes Add supplied label to cover on-site if controlling 120 VAC 4-9/16"4-5/16" (116 mm)(109 mm) Light pipe for LED viewing 4-5/16" (109 mm) 4-9/16" (116 mm) 4090-9801, Trim plate for4090-9802, Trim plate for semi-flush mounted boxsurface mounted box Optional Trim Plates for 4" Square Boxes with Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4090-0014-3 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Fire Alarm System Accessories RSG Electromagnetic Door Holders; UL, ULC, CSFM Listed; Wall Mounted or Floor Mounted FM Approved* Features Product Reference Images Electromagnetic door holders from RSG (Reliable (shown without screw hole caps in place) Security Group) with four mounting types: Semi-flush wall mount for shallow box applications Surface wall mount with matching box Flush wall mount with recessed magnet for low profile applications Floor mount, for single or double doors Multiple finish options: High luster plating of chrome, brass, or dark bronze Powdercoated in chrome or dark bronze Low current, multi-voltage design reduces power supply and battery demands: Models are available for operation with 24 VDC, 24 VAC, or 120 VAC Semi-Flush Wall Mount Door Holder Magnet and Catch Plate Assembly Internal full wave rectifier allows AC or DC operation and provides switching transient suppression Low residual magnetism allows easy door release for compatibility with low pressure door closers Rated holding force ranges from 20 lbs (9 kg) minimum; to up to 110 lbs (49.8 kg) Quick and easy installation: Self-adjusting swivel catch plate adjusts to door alignment changes Adhesive mounting templates assure alignment Required mounting hardware is supplied with each door holder Magnet catch plates can be screwed to wooden doors or drilled through and attached to a mounting bracket Surface Wall Mount Door Holder Magnet with Supplied Box Floor mount door holders include drills and anchors for mounting to concrete floors and hardware for mounting to wooden floors Front plates provide convenient grounding screw location Optional accessories: Extension rods are available in multiple lengths to allow proper alignment, including a 4” (102 mm) long pivoting rod Drilling fixture for accurate repetitive installation UL listed to Standard 228 Floor Mount Door Holder Magnet with Description Supplied Bracket and Box (Single door model shown, available for double doors) Door holders are normally energized to magnetically hold doors open. In the event of a fire emergency, the fire * These products have been approved by the California State Fire Marshal (CSFM) alarm control panel or other compatible control means pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3550-1039:0100 for allowable values and/or conditions concerning material presented in will release the magnet allowing the door to close to this document. It is subject to re-examination, revision, and possible cancellation. prevent the spread of smoke. Doors may be manually Additional listings may be applicable, contact your local Simplex® product supplier for the closed or opened when the door holder is energized. latest status. Listings and approvals are under RSG, Reliable Security Group. S2088-0014-2 8/2012 Product Selection (see specifications on page 4 and part number selection below) Mounting Type Hardware Included Electrical Box Requirement Semi-flush Mount Magnet assembly, catch plate with bracket, screw hole Single gang box, 1 ½” deep (partially recessed caps, and required mounting hardware minimum (supplied separately) magnet) Magnet assembly, catch plate with bracket, screw hole Flush Mount Single gang box, 2 ¼” deep caps, and required mounting hardware (not shown on (fully recessed magnet) minimum (supplied separately) page 1, refer to illustration on page 3) Magnet assembly, catch plate with bracket, screw hole caps, matching electrical box, and required mounting Surface Mount hardware Magnet assembly with electrical box, catch plate with Floor (ground) Mount for Box is supplied with door holder: bracket, floor mounting bracket, screw hole caps, and single door with single 4 ¾” H x 2 ¾” W x 1 ½” D required mounting hardware including drills and anchors for magnet concrete floors (117 mm x 70 mm x 54 mm) Two surface mount magnet assemblies with electrical box, Floor (ground) Mount for each with electrical box; two catch plates with brackets, double door with double screw hole caps, and required mounting hardware including magnets drills and anchors for concrete floors Optional Door Holder Accessories Model Description Powdercoat Brass Chrome DHE1PC DHE1B Catch plate extender rod, 1” (25.4 mm) long Each extender DHE1.5PC DHE1.5B Catch plate extender rod, 1 ½ ” (38 mm) long rod includes two DHE2PC DHE2B Catch plate extender rod, 2” (51 mm) long DHW extension DHE3PC DHE3B Catch plate extender rod, 3” (76 mm) long DHE3PC DHE3B Catch plate ext wrenches DHE4APC DHE4AB Catch plate with adjustable extender rod, 4” (102 mm) long with center pivot Model Description DHDF Drilling Fixture, provides convenient alignment for repetitive installation Extension Wrench for adding extender rod to catch plate (two are needed, two are shipped with each DHW extension) Door Holder Part Number Selection Select from each of the 6 categories to create part number (see examples below) 1 2 3 4 5 6 Door Holder Operating Voltages Mounting Style Finish Type Finish Color Floor Mount Coils For For For For For Select Select Select Select Select Select Surface 12 VDC S S Mount 12 VAC C 1224PPowdercoated Chrome Single 1224C P 1 24 VDC Semi-Flush door F 24 VAC Mount Floor Double 24 VDC DH GB2 Brass (Ground) DH door 24120 24 VAC Mount 120 VAC High luster blank plated Flush Mount DarkNot floor 24 VDC (Recessed RDBRblank Bronze mounted 24 VAC 24220 Magnet) 220 VAC Examples: DH24120RPC 1.: Door holder; 24 VDC/VAC, or 120 VAC operation; Recessed magnet/flush mount; Powdercoated; Chrome finish DH24120GB2: 2. Door holder; 24 VDC/VAC, or 120 VAC operation; Ground/floor mount; Brass finish, high luster; Double door DH1224SPC:urface mount; Powdercoated; Chrome finish 3. Door holder; 12 or 24 VDC/VAC operation; S 2 S2088-0014-2 8/2012 Semi-Flush and Surface Mount Dimensions 15/16" (24 mm) 15/16"1-1/8" 1-1/2" (24 mm)(29 mm) (38 mm) 2-3/4" 2-7/16" (70 mm) (62 mm) 2-3/4" 3-5/16"4-5/8"4-3/4" (70 mm) (84 mm)(117 mm)(121 mm) Surface Mount End View (mount vertically or horizontally as needed) Semi-Flush and Surface Semi-Flush Surface Mount Side View Mount Front ViewSide View (conduit entries are provided on ends and back of box) Flush and Floor Mount Dimensions 1-13/16" 3" (46 mm) (76 mm) 4" (102 mm) 3-5/16" 4-3/4" (84 mm) (121 mm) Single Door 3" (76 mm) Double Door 5-7/16" (138 mm) Flush Mount Flush Mount Front View Floor Mount Side View Side View 3 S2088-0014-2 8/2012 Catch Plate and Mounting Bracket Dimensions Catch Plate 2-3/16" (56 mm) Catch Plate Mounting Bracket 2-3/8" 3/16" (60 mm) Screw holes (5 mm) 1-3/4" 2-1/4" 1-3/4" (44 mm) (57 mm) 7/8" (44 mm) (22 mm) 1-3/4" Magnet side Door side (44 mm) Ball swivel 3/4" (19 mm) Threaded rod extensions insert here Specifications Mechanical Specifications Material Durable die-cast metal Three position terminal block with provisions for in/out wiring; common (C), low voltage, high Wiring Connections 2 voltage); 22 to 12 AWG (0.5 to 3.31 mm) Electrical Specifications and Performance Model Voltage Current DC Current AC Terminals Holding 12 V 40 mA 38 mA C & L 1224 30 lbs (13.6 kg) 24 V 40 mA 36 mA C & H 1224 High Holding Force 24 V 85 mA 81 mA C & L 75 lbs (34 kg) 24 V 20 mA 19 mA C & L 40 lbs (18.1 kg) 24120 120 VAC – 20 mA C & H 35 lbs (15.8 kg) 24120 High Holding Force 120 VAC – 100 mA C & L 110 lbs (49.8 kg) 24 V 20 mA 19 mA C & L 20 lbs (9 kg) 24220 220 VAC – 15 mA C & H 22 lbs (9.8 kg) For additional information, visit the RSG website: http://www.rsgsecurity.com/ TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. S2088-0014-2 8/2012 Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA www.simplexgrinnell.com © 2012 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Series RSS and RSSP Strobes and Strobe Plates Series RSSWP Series RSSSeries RSS Description Features The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost Ordering Information effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the selectable candela settings of 15/30/75/110cd or the high Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. intensity MCWH strobe with field selectable 135/185cd. Single Candela models are available in 1575cd Ceiling mount models include the patented MCC multi-candela or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock DSM Sync range Modules, Wheelock Power Supplies or other manufacturers - panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions synchronized strobes offer an easy way to comply with ADA built-in Wheelock Patented Sync Protocol recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. AWG wire The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4” square, 100mm European backboxes or the For Weatherproof Series RSS See Datatsheet S9004 Appliance Trimplate) may be used. It provides an additional .65” of trim for the Appliance. An attractive cover plate is provided The Series RSSP Multi-Candela Strobe Plates are a cost bells, horns, chimes, multitones or speakers and easily mounts to standard 4” backboxes or for surface mount use with the Wheelock SBL2 surface backbox. UIF!DJUZ!PG OFX!ZPSL ¯ EFQBSUNFOU!PG!CVJMEJOHT . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Table 1: Average RMS Current* RSS/RSSP - Wall Mount Ceiling Mount RSS/RSSP 241575W24MCW24MCWH24MCC24MCCH 24VDC Models 1575cd15cd30cd75cd110cd135cd185cd15cd30cd75cd115cd177cd 0.0600.1650.2200.3000.4200.0650.1050.3000.420 RSS/RSSP RSS/RSSP Wall Mount 24VDC Models 121575W 12 vdc0.152 0.255 see installation instructions. Table 2: Audibles/Speakers for RSSP Strobe Plate ProductSeries Wiring Diagrams # Multitone AppliancesAMT, MT SERIES RSS/RSSP APPLIANCE HornsAH, NH, HS UP!OFYU Motor BellsMB-G6/G10 GSPN ,, QSFDFEJOH BQQMJBODF .. SpeakersET-1010/1080, E70, ET70 BQQMJBODF-!TZOD PS!FPMS NPEVMF-!QPXFS ChimesCH70 TVQQMZ!PS!GBDQ . , SERIES RSS/RSSP APPLIANCES SYNCHRONIZED SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS “A” NAC CIRCUIT WITH MULTIPLE DSM MODULES ETN!$2 ETN TUSPCF , Tzod OBD TZOD Tuspcf!OBD!Djs/ STTSTT , . DJSDVJU G . ,PVU!2 PVU ETN!$3 STTSTT STT ,!JO!2 B Tzod NJOVT!2 Tuspcf!OBD!Djs/ STT STT , , GBDQ D. BVEJCMF . ETN!$4 NJOVT!3 Q Tzod STT ,!JO!3 STTSTT STTSTT TUSPCF , Tuspcf!OBD!Djs/ . ,!PVU!3 OBD DJSDVJU ETN!Joufsdpoofdujoh!xjsjoh!tipxo/!Nbyjnvn!pg SFUVSO uxfouz!)31* STROBE/PLATE ASSEMBLY UP!OFYU BQQMJBODF GSPN , , . PS!FPMS QSFDFEJOH . SERIES RSS/RSSP APPLIANCES SYNCHRONIZED BQQMJBODF-!TZOD WITH WHEELOCK POWER SUPPLIES NPEVMF-!QPXFS TVQQMZ!PS!GBDQ Tfsjft!QT!Qpxfs!Tvqqmjft .. ,, TUSPCFBVEJCMF IT STT FPMS PVUQVUT 2.5 G 5.DMBTT #C# B STROBE/PLATE ASSEMBLY PS IT STT 3.DMBTT D #B# Q , , GSPN UP!OFYU QSFDFEJOH BQQMJBODF BQQMJBODF!PS .. PS!FPMS GBDQ STT IT Tfsjft!QT!Qpxfs!Tvqqmjft ,, GSPN UP!OFYU . QSFDFEJOH .TUSPCF!PS TUSPCF-!TZOD FPMS NPEVMF-!QPXFS TVQQMZ!PS!GBDQ . ,,. BQQMJBODF TUSPCF For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Wheelock Power Supplies. Square Order Wall Ceiling Non-Strobe 24 12 Color Color ModelMounting Options***or CodeMountMountCandelaVDCVDCREDWHITE ULMEACSFMFMBFP Round RSS-24MCW-FRX-X15/30/75/110X-X-B,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-24MCW-FR RSS-24MCW-FWX-X15/30/75/110X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXXX X-X15/30/75/110X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-241575W-FR7471X-XX-X-B,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-241575W-FW7788X-XX--XB,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-121575W-FR7476X-X-XX-B,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-121575W-FW7468X-X-X-XB,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-24MCC-FW3158-XXX--XB,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSS-24MCC-FR3157-XXX-X-B,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSS-24MCCH-FW3461-XX115/177X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSS-24MCWH-FR3465X X135/185XXB,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSS-24MCWH-FW3464X X135/185XXB,D,E,F,G,H,J,N,O,R,XSquareXXXX- 180@ 77°F X-XX-X-B,D,E,F,G,H,J,N,O,R,XSquareXXXX- 75@ -31°F 180@ 77°F 3034X-XX--XB,D,E,F,G,H,J,N,O,R,XSquareXXXX- 75@ -31°F RSSP-121575W-FRX-X-XX-D,E,ZSquareX-XXX RSSP-24MCW-FRX-X15/30/75/110X-X-D,E,ZSquareXXXXX RSSP-241575W-FRX-X--X-D,E,ZSquareXXXXX RSSP-24MCWH-FRXX135/185XXB,D,E,F,G,H,J,N,O,R,XSquareXXX-- All models sync with Wheelock DSM or Wheelock Power Supplies. Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. or the Wheelock SBL2 backbox for surface mounting. S0410 RSS/RSSP 07/11 OK!Mpdbujpo 384!Csbodiqpsu!Bwf/ Mpoh!Csbodi-!OK!18851 Q;!911.742.3259 G;!843.333.9818 xxx/dppqfsopujgjdbujpo/dpn