HomeMy WebLinkAboutLOT LAYOUT PLAN - Evans Michael Charlene - IMPACT AREAD
R
A
I
N
F
I
E
L
D
A
L
T
E
R
N
A
T
E
D
R
A
I
N
F
I
E
L
D
135'89'58'-11.38"
1
7
3
'
-
4
"
5
8
'
1
0
0
'
283.00'
W 400 S
283.00'
3
0
1
.
3
1
'
3 0 0 .6 2 '
3 0 '
3
0
'
NEW
HOME
WELL
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
P L O T P L A N
C O N T R A C T O R :
REV. DATE:
P R O J E C T D E S C R I P T I O N :
1
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
24x36: 1" = 10'
11x17: 1" = 20'
PLOT PLAN
D R A W N B Y :
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
PART OF NE 1/4,
SEC 26, TWP. 6 N.
RANGE 39 E, B.M.
MADISON COUNTY,
IDAHO
INS. 425789
TRACT 2
1.96 ACRES
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
C O N T R A C T O R :
REV. DATE:
P R O J E C T D E S C R I P T I O N :
2
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
RENDERINGS
NOT TO SCALE
D R A W N B Y :
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
P r e s e n t a t i o n V i e w s
Main
Floor
Michael & Charlene Evans
Upper
Floor
Roof
Model
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •
All Exterior Headers to be 1 ply 9 1/2" LVL
Garage Door Headers to be 2 ply 11 7/8" LVL
Unless Otherwise Noted
363590
3050FX 3050FX 3050FX
3 0 5 0 S H
3 0 5 0 S H
4 0 4 0 L S
3 0 5 0 S H
3 0 5 0 S H
2 6 3 6 S H
2 6 3 6 S H
3 0 5 0 S H
3 0 5 0 S H
5068
3 0 5 0 S H
3 0 5 0 S H
3050SH 5050FX 3050SH
3 0 6 8
2 8 6 8
2868
2 8 6 8
2868
2 6 6 8
2 4 6 8
2 8 6 8
3050SH3050SH1668FX30681668FX3050SH3050SH
3068
3 0 6 8
4 0 6 8
2 8 6 8
3 0 6 8
3050SH3050SH
1 5 8 8 0
9 0 8 0
3050SH 3068
3 0 6 8
3 0 6 8
5068 5068
3050SH
2 4 6 8
2868
2868
UP
M/O
1919101 1919101 1919101 1919101 19191011919101 1919101
1919101
1919101
10'14'10'7'-0 1/2"8'-11"7'-4"2'-6"2'-6"7'-4"8'-11"2'-5 1/2"
34'47'
2 '-6 "
3 '-3 "
8 '-0 9 /1 6 "
1 2 '-2 7 /1 6 "
7 '
1 5 '
1 0 '
2 6 '
3 2 '
8 '
4'-9"4'-3"4'-3"4'-9"1'-10 1/2"8'-1"3'-4"4'-8"3'-4"3'-8 1/2"3'-9"3'-3"3'-3"3'-9"4'-6"9'-6"10'
18'13'-3 1/2"4'-8"7'-0 1/2"14'24'
81'
1 6 '
5 '-1 0 "
3 '-3 "
6 '-7 "
1 4 '-2 "
9 '-1 1 "
2 '-3 "
1 8 '
4 0 '
5 8 '
2 '-3 "
3 '-3 "
2 '-6 "
8 '
81'
5 8 '
13'-1"
2 4 '-3 1 /2 "
9 '-2 1 /2 "
5 '
2'-1"3'-6"7'-7"
6 '
5 '-8 1 /2 "
10'-9 1/2"2'-8"14'2'-1"9'-3"2'-1"13'-5 1/2"
6'-5"3'-6"4'-4"3'-6"2'-7"3'-9"3'-9 1/2"
17'-1"
1 3 '-6 "
1 5 '
1 0 '
5 '-8 1 /2 "
4 '
7 '-8 1 /2 "
7 '
5'-6"5'6'
5'
9'-9 1/2"7'
3 '
4 '-5 "
5'
1 0 '
1 8 '-9 1 /2 "
34'-8"4'
1 '-4 "
7 '-7 1 /8 "
1 1 '-6 1 /2 "
3'-11 1/2"
ROOM FINISH SCHEDULE
ROOM NAME AREA(SQ.FT.)
MASTER BDRM 228
KITCHEN 331
FAMILY 425
OFFICE 133
LIVING 184
COAT 7
O.CLST 11
MECH 42
PANTRY 18
LAUNDRY 90
FOYER 119
BATH 2 40
MSTR CLST 67
MASTER BATH 95
PWD 14
SHW 21
GARAGE 892
PWD 15
UNDER STAIR 43
WINDOW SCHEDULE
Numbers are Width Feet
and Inches followed by
Height Feet and Inches
FLOORING
SCHEDULE
CABINET
SCHEDULE
CONCRETE
CARPET FLOOR
WOOD FLOOR
TILE FLOOR
LVP
LVT
EPOXY
LOWERS
UPPERS
FULL HEIGHT
Room Finish Schedule is for Flooring
Purposes Only. Please Refer to
Numbers Listed in Title Block for
Actual House Square Footage.
SH Single Hung
DH Double Hung
SC Single Casement
DC Double Casement
TC Triple Casement
LS Left Sliding
RS Right Sliding
TS Triple Sliding
AW Single Awning
FA Double Awning
TA Triple Awning
HO Single Hopper
FO double hopper
TO Triple Hopper
LO Louvered
GL Glass Louvered
PT Pass-Through
MASTER BDRM
FAMILY
OFFICE
LIVING
C O A T
11
Note Schedule
Book Shelves
Bench and Coat Hooks
11
22
11
22
O .C L S T
MECH
P A N T R Y
LAUNDRY
FOYER
B A T H 2
MSTR CLST
MASTER
BATH
PWD
SHW
PATIO
PORCH
GARAGE
22
Wood
Burning
With
Chimney
PWD
K I T C H E N
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
F l o o r P l a n - M a i n
MAIN FLOOR
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
C O N T R A C T O R :
REV. DATE:
Ceiling Height 9' Unless Otherwise Noted
P R O J E C T D E S C R I P T I O N :
3
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
D R A W N B Y :
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •
DN
3 0 1 6 L S
2868
5040LS
2 8 6 8
5040FX
2868
4040LS
2 6 6 8
2868
5 0 2 0 L S
5030LS
4 0 6 8
4 0 6 8
7'-3 1/2"7'-3 1/2"
14'-11 1/2"14'-7"13'-11"
43'-5 1/2"
7 '-1 1 9 /1 6 "
1 3 '-7 1 5 /1 6 "
1 0 '-4 1 /2 "
2 1 '-7 1 /2 "
3 2 '
23'-1 1/2"6'-10"1'-4"4'-8"7'-6"
43'-5 1/2"
1 9 '-6 1 /2 "
1 2 '-5 1 /2 "
3 2 '
4'-8"
13'-8"
35'-7"6'-8"
1 8 '-7 1 /2 "
1 0 '-2 1 /2 "
5 '-6 "
4 '-5 "
25'-2"14'-8 1/2"2'-1"
10'-11"12'-2 1/2"3'-5"3'-5"1'-4"4'-8"3'-9"3'-9"
3'-6"
9 '-9 1 /4 "
9 '-9 1 /4 "
5 '-1 1 "
4 '
5 '
1 0 '-1 "
S T A I R W E L LSITTING
BEDROOM 3
BEDROOM 2
Window Seat
V A N I T Y
C L S T 3
B A T H 3
LIN
Closets in Attic Space
TBD on Site
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
F l o o r P l a n - U p p e r
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
C O N T R A C T O R :
REV. DATE:
P R O J E C T D E S C R I P T I O N :
4
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
All Exterior Headers to be 1 ply 9 1/2" LVL
Garage Door Headers to be 2 ply 11 7/8" LVL
Unless Otherwise Noted
D R A W N B Y :
UPPER FLOOR
Ceiling Height 8' Unless Otherwise Noted
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
C O N T R A C T O R :
ELEVATIONS
Front
Elevation
REV. DATE:
E x t e r i o r E l e v a t i o n s
Back
Elevation
P R O J E C T D E S C R I P T I O N :
5
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
D R A W N B Y :
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •
FINISH ROOFINGRAFTER
ROOFING MEMBRANE
FLASHING
TRIM
SOFFIT
FASCIA
BAFFLE
VENTED AIRSPACE
SOFFIT FURRING
SCREENED VENT
FINISH SIDING
SHEATHING
INSULATION
Treads shall be at least 10" deep, risers
shall not be greater than 7 3/4" in
height. Riser variation shall not exceed
3/8" within any flight.
Minimum headroom in all parts of the
stairway shall not be less than 6'8"
measured vertically from the sloped line
adjoining the tread nosing or from the
floor surface of the landing or platform
on that portion of the stairway.
5/8" Gypsum Board Typical All Ceilings
1/2" Gypsum Board Typical All Walls
Typical Exterior Framing 2x6, 24 OC
7/16" Typical OSB Sheathing
Min R21 Insulation
6mil Poly Vaper Barrier
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
CROSS SECTION
C O N T R A C T O R :
REV. DATE:
E x t e r i o r E l e v a t i o n s
P R O J E C T D E S C R I P T I O N :
6
ELEVATIONS
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
D R A W N B Y :
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
Left
Elevation
Right
Elevation
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •
8 '
3 '-9 "
Concrete Reinforcement Specification
8'0"
One No. 4 bar within 12" of the top
of the wall story with one No. 4 bar
near mid-height of wall story
Horizontal Reinforcement
Walls: 8"
Vertical Reinforcement #4 @ 16"O.C.
Footings: 8"x16"
Reinforecement 2 Continuous #4
1/2
11 7/8" I-Joist
R-21 INSULATION
RIM JOIST
BATT
INSULATION
(in crawlspace)
2 X 6 EXTERIOR WALL
SIDING
SHEATHING
WALLBOARD
3/4" T&G SUBFLOOR
VERTICAL STEEL
REINFORCING REBAR
AS REQUIRED
COMPACTED
SOIL REINFORCING STEEL AS
REQUIRED
2x6 TREATED PLATECAST-IN-PLACE
ANCHOR BOLT
SILL SEAL
CONCRETE
FOUNDATION WALL
8X16 CONCRETE FOOTING
Concrete Stem Wall w/11 7/8" I-Joist
SILL SEALER
WALL STRUCTURE
INSULATION
(crawlspace only)
2x FLOOR JOISTS or TRUSS
CONCRETE
STEMWALL
FINISH SIDING
& SHEATHING
CAST-IN-PLACE
ANCHOR BOLT
FINISH FLOOR
TREATED MUDSILL
2x RIM JOIST
#8 J Bolt 48" OC
with 3"x3" Square Washers
4" CONCRETE SLAB
REINFORCING WIRE FABRIC
Concrete Slab at Garage Foundation
SHEATHING/SIDING
1" EXPANSION JOINT
2x TREATED MUDSILL
CAST-IN-PLACE ANCHOR BOLT
2x WOOD FRAMING MEMBER
SILL SEALER
CONCRETE FOUNDATION
CONCRETE FOOTING
4" GRAVEL
34'55'
89'
2 0 '-9 "
2 9 '-3 "
5 0 '
8 '
18'25'14'
57'
8'
4'-6"19'-6"
24'
7 '
1 5 '
1 0 '
3 2 '
5 8 '
8 '-4 "
1 7 '-8 "
1 '-4 3 /4 "
7 '-8 "
8 '
1 3 '-0 3 /4 "
9 '-1 1 1 /4 "
1 3 '-4 "
1 7 '-4 "
23'-4"9'-4"47'7'-4"
9 '-4 "
7 '-4 "
17'-8 1/4"4'-0 1/2"20'-11 1/4"14'-4"
GARAGE
F o u n d a t i o n
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
FOUNDATION
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
C O N T R A C T O R :
REV. DATE:
P R O J E C T D E S C R I P T I O N :
7
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
D R A W N B Y :
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •
UP
4 : 1 2
4 : 1 2
8 : 1 2
8 : 1 2
8 : 128 : 12 8 : 1 2
8 : 12 8 : 12
4 : 12
4 : 1 2
4 : 1 2
18" Typ. Overhang
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
C O N T R A C T O R :
REV. DATE:
P R O J E C T D E S C R I P T I O N :
8
R o o f P l a n
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
ROOF PLAN
D R A W N B Y :
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •
UP
sthd14rj
Concrete Strap
Blocks at
Drywall
Joint for 7" o.c.
Screws
or Nails
2x4 Interior Wall
@16" o.c.
2x6 Exterior Wall
@ 16" o.c. with
7/16" Waferboard
Overlapped
Double
PlateDrywall and Waferboard
Not shown for Clarity
BRACE WALL PANEL DETAIL
4 8 "
4'x8'
Shear Paneling
on Both sides
or
8'x8'
Shear Paneling
on Single Side
4 8 "Nailing or Screws
7" o.c. Max,
Horz and Vert
(2) Anchor Bolts per Panel
to be Placed at Panel
Quarter Point
The Panel shall be Supported Directly
on a Foundation or on Floor Framing Supported
Directly on a Foundation which is Continuous
Across the Entire Length of Braced Wall
Tie-Down Device Fastened to
The Foundation Capable of
Providing an Uplift Capacity
of at Least 1,800 lbs
Block all Wood Structural
Panel Sheathing Edges
Sheathing One Face with 3/8" min
Thickness Wood Structural Panel Nailed
with 8d Common or Galvanized Box
Nails @ 6" o.c. Edge and 12" o.c.
Intermediate
1 0 ' 0 " M a x
ALTERNATE BRACE WALL
PANEL DETAIL
Brace Wall Panel
Holddown 1800LBF
sthd14rj
Concrete Strap
s t h d 1 4 r j
C o n c r e t e S t r a p
s t h d 1 4 r j
C o n c r e t e S t r a p
sthd14rj
Concrete Strap
sthd14rj
Concrete Strap
sthd14rj
Concrete Strap
sthd14rj
Concrete Strap
sthd14rj
Concrete Strap
sthd14rj
Concrete Strap
M i c h a e l & C h a r l e n e E v a n s
M a i n : 2 0 7 0 S q .F t .
U p p e r : 1 0 7 0 S q .F t .
T o t a l : 3 1 4 0 S q .F t .
P A G E D E S C R I P T I O N :
Sheet Size:Scale
24x36:1/4" = 1'
11x17:1/8" = 1'
SHEET:To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made
on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all
dimensions and enclosed drawing. Idaho Home Design is not liable for errors once construction has begun. While every effort has
been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of
the job must check all dimensions and other details prior to construction and be solely responsible thereafter.
C O N T R A C T O R :
REV. DATE:
BRACE WALL DETAIL
P R O J E C T D E S C R I P T I O N :
9
HOMEOWNER & CONTRACTOR:
TO VERIFY ALL DIMENSIONS,
STRUCTURAL DETAILS, AND
BUILDING CODES, AND GRADE
REQUIREMENTS.
THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND
PROPERTY OF IDAHO HOME DESIGN, DEVELOPED FOR THE EXCLUSIVE
USE OF IDAHO HOME DESIGN. USE OF THESE DRAWINGS AND CONCEPTS
CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF IDAHO
HOME DESIGN IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR
DAMAGES IN THE AMOUNT OF $10,000 PER VIOLATION
DO NOT BID, PERMIT, OR BUILD FOR
ANY CONTRACTOR OTHER THAN
MICHAEL AND CHARLENE EVANS OR
IDAHO HOME DESIGN
FAILURE TO ABIDE BY THIS WILL
RESULT IN VIOLATION AS STATED.
8/4/2020
D R A W N B Y :
Homeowner Initials_______ Date________
Homeowner Initials_______ Date________
I d a h o H o m e D e s i g n
T a n y a C r o m w e l l
2 0 8 -5 8 9 -9 5 5 8
B r a c e W a l l D e t a i l
CONTRACTOR MUST CHECK ALL OF PLAN FOR ACCURACY. LIST
MAY VARY FROM ACTUAL PLAN. FOR ESTIMATION PURPOSES
ONLY. DO NOT ORDER FROM LIST. CHECK WITH CLIENT OR
CONTRACTOR FOR FINAL SPECIFICATIONS
2 0 8 -5 8 9 -9 5 5 8
T u r n i n g A m e r i c a n
D r e a m s I n t o R e a l i t i e s
•H o u s e P l a n s •R e n d e r i n g s •I n t e r i o r D e s i g n •S p a c e P l a n n i n g •C u s t o m I n t e r i o r s •P r o j e c t M a n a g e m e n t •