Loading...
HomeMy WebLinkAboutSHORT FORM - 08-00031 - 556 Cook St - R7 InvestmentShort Form Entire House Belnap Rexburg, ID 83440 Project Infl, For: Brett Belnap Job: Lot 1 Block 10 Date: Oct 16, 2006 By: 0800031 556 Cook St -R7 Investment ROOM NAME Area (ft2) Design• • Htg AVF (cfm) Clg AVF (cfm) Room1 Htg Clg Infiltration 32 53 Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TO (°F) 76 14 Fireplaces 1751 0 Daily range - H 78 656 213 Inside humidity (%) 10 50 234 2919 715 Moisture difference (gr/Ib) 33 -31 313 3651 936 HEATING EQUIPMENT 44 COOLING EQUIPMENT 506 Make 388 53 Make Room11 195 Trade 162 22 Trade Room12 78 Model 35 5 Cond Room13 176 2427 174 23 Coil 4 14 Efficiency 80 AFUE Efficiency 0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 326 cfm Actual air flow 326 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area (ft2) Htg load (Btph) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Room1 224 3295 1130 32 53 Room2 9,8 2144 657 21 31 Room3 454 4289 1739 41 81 Room4 156 1751 461 17 22 Room5 78 656 213 6 10 Room6 234 2919 715 28 33 Room7 313 3651 936 35 44 Room10 506 5567 388 53 18 Room11 195 2305 162 22 8 Room12 78 541 35 5 2 Room13 176 2427 174 23 8 4 14 oom 632 4529 355 43 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ti wrightsoft Right -Suite Residential 6.0.22 RSR40897 2008 -Jen -0710:01:00 olm CAMy Documents\Wrightsoft HVAC\TemplateWarious Houses\Brelt Belnepmp Calc =MJ8 orientation Pagel Entire House 3144 34074 6964 326 326 Other equip loads 4780 880 Equip. @ 0.94 RSM 7374 Latent cooling 0 TOTALS 31 44 38853 7374 326 326 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right -Suite Residential 6.0.22 RSR40897 2008 -Jan -0710:01:00 ACM CAMy Documents\WdghtsoM HVAM-remplateWadous HousestBrett Belnap.0p Calc= MJ8 Orientation Page 2 Project Summary Entire House Belnap .:..r Project Information For: Brett Belnap Notes: Design Information Weather: Idaho Falls, ID, US Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TO 76 OF Heating Summary 0.28 0.15 Structure 29950 Btuh Ducts 4124 cfm Central vent (68 cfm) 4780 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 38853 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh 0 OF 326 cfm 0.010 cfm/Btuh 0.00 in H2O Job: Lot 1 Block 10 Date: Oct 16, 2006 By: Summer Design Conditions Outside db Heating Cooling Area (ft') 3144 3144 Volume (ft') 20416 20416 Air changes/hour 0.28 0.15 Equiv. AVF (cfm) 95 51 Heating Equipment Summary Make Equipment sensible load 7374 Trade Model Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh 0 OF 326 cfm 0.010 cfm/Btuh 0.00 in H2O Job: Lot 1 Block 10 Date: Oct 16, 2006 By: Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range H Btuh Relative humidity 50 % Moisture difference -31 gr/Ib Sensible Cooling Equipment Load Sizing Structure 4092 Btuh Ducts 2872 Btuh Central vent (68 cfm) 880 Btuh Blower 0 Btuh Use manufacturer's data n Btuh Rate/swing multiplier 0.94 ton Equipment sensible load 7374 Btuh Latent Cooling Equipment Load Sizing Structure -918 Btuh Ducts -94 Btuh Central vent (68 cfm) -1224 Btuh Equipment latent load 0 Btuh Equipment total load 7374 Btuh Req. total capacity at 0.70 SHR 0.9 ton Cooling Equipment Summary Make Trade Cond Coil Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 0 EER 0 Btuh 0 Btuh 0 Btuh 326 cfm 0.047 cfm/Btuh 0.00 in H2O 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. �+-• Wf1g11llt50f-C Right -Suite Residential 6.0.22 RBR40897 2008 -Jan -0710:01:00 14M C:\My Documents\Wrightsoft HVAC\Template\Various Houses\Brett Belnap.rrp Calc = MA Orientation Page 1 Main Floor Job #: Lot 1 Block 10 Performed for: Brett Belnap Belnap Rexburg, ID 83440 Scale: 1 : 102 Page 1 Right -Suite Residential 6.0.22 RSR40897 2008 -Jan -07 10:01:06 CAMy Documents\Wrightsoft HVA... Basement Job M Lot 1 Block 10 Performed for: Brett Belnap Belnap Rexburg, ID 83440 Scale: 1 : 102 Page 2 Right -Suite Residential 6.0.22 RSR40897 2008 -Jan -07 10:01:06 Documents\Wrightsoft