Loading...
HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 08-00031 - 556 Cook St - R7 InvestmentREScheck Software Version 4.1.2 Compliance Certificate Project Title: Cook St. R7 Investments Report Date: 01/22/08 Data flename: Untitled.rck Energy Code: 2000 IECC Location: Rexburg, Idaho Construction Type: Single Family Glazing Area Percentage: 17% Heating Degree Days: 8693 Construction Site: Owner/Agent: 556 Cook St. 1832 13.0 0.0 Rexburg, ID 83440 Wall height: 8.0' Permit # 08 00031 Permit Date: 1/22/08 Compliance: 11.9% Better Than Code Maximum UA: 394 Your UA: 347 Designer/Contractor: Ceiling 1: Flat Ceiling or Scissor Truss 1534 0.0 38.0 38 Wall 1: Wood Frame, 16" o.c. 1832 21.0 0.0 82 Window 1: Vinyl Frame:Double Pane with Low -E 308 0.310 95 Door 1: Solid 80 0.300 24 Basement Wall 2: Solid Concrete or Masonry 1832 13.0 0.0 108 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Furnace 1: Forced Hot Air87 AFUE Compliance Statement., The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 4.1.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: Cook St. R7 Investments Page 1 of 4 Data filename: Untitled.rck Report date: 01/22/08 ArlREScheck Software Version 4.1.2 Inspection Checklist Date: 01/22/08 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-21.0 cavity Insulation Comments: Basement Walls: ❑ Basement Wall 2: Solid Concrete or Masonry, 8.0' ht / 7.0' bg / 8.0' insul, R-13.0 cavity insulation Comments: Windows: ❑ Window 1: Vinyl Frame:Double Pane with Low -E, U -factor: 0.310 For windows without labeled U -factors, describe features: #Panes — Frame Type Thermal Break? —Yes No Comments: Doors: ❑ Door 1: Solid, U -tactor: 0.300 Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 87 AFUE or higher Make and Model Number: Air Leakage: O Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. n Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation. Vapor Retarder: LJ Installed on the warm -in -winter side of all non -vented framed ceilings, walls, and Floors. Materials Identification: Materials and equipment are installed in accordance with the manufacturer's installation Instructions. Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Insulation R -values, glazing U -factors, and heating equipment efficiency are clearly marked on the building plans or specifications. Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the Insulation. Duct Insulation: Ducts in unconditioned spaces are insulated to R-5. Ducts outside the building are insulated to R-8.0. Duct Construction: All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastio-plus-embedded-fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181B. Project Title: Cook St. R7 Investments Page 2 of 4 Data filename: Untitled.rck Report date: 01/22/08 Exceptions: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). F-1 The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: O Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: Cook St. R7 Investments Data filename: Untitled.rck Page 3 of 4 Report date: 01/22/08 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Fluid Temp. Insulation Thickness In Inches by Pipe Sizes Ranna!°FI 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" Temperature (°F) 120-200 0.5 1.0 1.0 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Fluid Temp. Insulation Thickness In Inches by Pipe Sizes Ranna!°FI 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Project Title: Cook St. R7 Investments Data filename: Untitled.rck Page 4 of 4 Report date: 01/22/08