Loading...
HomeMy WebLinkAboutRESCHECK - 20-00659 - 991 Pine Brook Ln - New SFRREScheck Software Version 4.6.5 Compliance Certificate Project Snyder - Cooper Energy Code:2015 IECC Location:Idaho Falls, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:4,697 ft2 Glazing Area 15% Climate Zone:6 (7918 HDD) Permit Date: Construction Site:Owner/Agent: Sprinter Heating & Hydronics Designer/Contractor: Mechanical Compliance Solutions Gene Miller 4181 Aschli lane Idaho Falls, ID 83406 208-881-3243 1sgmiller@cableone.net Permit Number: Compliance: Passes using UA trade-off 0.2% Better Than Code Maximum UA:460 Your UA:459 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.873 21.0 0.0 0.057 43 Door 1: Solid 53 0.140 7 Window 1: 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr 70 0.320 22 Wall 2: Wood Frame, 16" o.c.745 21.0 0.0 0.057 42 Window 1: 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr 12 0.310 4 Wall 3: Wood Frame, 16" o.c.873 21.0 0.0 0.057 32 Window 1: 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr 305 0.310 95 Wall 4: Wood Frame, 16" o.c.745 21.0 0.0 0.057 37 Door 1: Solid 42 0.140 6 Window 1: 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr 46 0.310 14 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' 508 19.0 0.0 0.044 22 Basement Wall 2: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' 468 19.0 0.0 0.044 21 Project Title: Snyder - Cooper Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Snyder - Cooper.rck Page 1 of 2 09/03/20Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Basement Wall 3: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' 508 19.0 0.0 0.044 21 Window 1: 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr 32 0.310 10 Basement Wall 4: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' 468 19.0 0.0 0.044 19 Window 1: 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr 32 0.310 10 Ceiling 1: Flat Ceiling or Scissor Truss 2,087 50.0 0.0 0.026 54 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: Snyder - Cooper INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: Snyder - Cooper Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Snyder - Cooper.rck Page 2 of 2 09/03/20Report date: